VRNE-60ED20 [BEL]
6 VDC â 13.8 VDC Input 0.6 VDC â 2.0 VDC /30 A Output;型号: | VRNE-60ED20 |
厂家: | BEL FUSE INC. |
描述: | 6 VDC â 13.8 VDC Input 0.6 VDC â 2.0 VDC /30 A Output |
文件: | 总11页 (文件大小:639K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
The VRNE-60ED10/20 has dual non-isolated step down DC/DC
converters providing up to 40A/ 5A (VDD/ VTT) of output current and
designed to be compatible with the Intel VRM12 requirements.
Standard features include remote on/off, over current protection,
remote sense, Power Good and VR_ Hot signal. These products may
be used almost anywhere low-voltage silicon is being employed and a
nominal 12V source is available. Typical applications include file
servers, work stations and other computing applications.
6 VDC – 13.8 VDC Input
0.6 VDC – 2.0 VDC /30 A Output
Dual Output
Thermal Warning
High Efficiency
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Remote ON/OFF
High Power Density
2-Wire Remote Sense
Wide Input Range (6.0-13.8V)
OCP/SCP
Output Current Monitor
SVID
Input under-voltage protection
VR12.0 Compliant
Output Overvoltage Protection
Class II, Category 2, Non-Isolated DC/DC Converter
(refer to IPC-9592A)
Networking
Computers and Peripherals
Telecommunications
•
•
•
2
VRNE-60ED10/20 Series
OUTPUT
VOLTAGE
MAX. OUTPUT
CURRENT
MAX. OUTPUT
POWER
TYPICAL
EFFICIENCY
MODEL NUMBER
ACTIVE HIGH
VRNE-60ED10
INPUT VOLTAGE
1.5 VDC – 0.75 VDC
6.0 VDC - 13.8 VDC
40 A/5 A
60 W + 3.75 W
85%
VRNE-60ED20
NOTE: 1.Add “G” suffix at the end of the model numbers listed above to indicate “Tray Packaging”.
V
R
NE
-
60
E
Dx
0
x
Mounting
type
Output
power
Enable pin
location
D1-pin23
RoHS status
Series name
Input range
Logic status
Package
enable,
pin24-NIL
D2- pin24
enable,
Vertical
mount
6.0 -13.8V
RoHS 6
VRNE series
60W
Active high
G -Tray
pin23-NIL
PARAMETER
DESCRIPTION
MIN
TYP
MAX
15
UNITS
Continuous non-operating Input Voltage
Input Transient Voltage
Remote On/Off
-0.3
-
-
-
-
-
-
V
V
100mS maximum
22
-0.3
0
5.3
70
V
Ambient Temperature
C
C
Storage Temperature
-40
125
NOTE: Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may permanently damage the device.
PARAMETER
DESCRIPTION
MIN
TYP
12
-
MAX
13.8
13.5
UNIT
6
-
V
A
Operating Input Voltage
Input Current (full load)
Vin=6V
160
200
250
mA
Input Current (no load)
Vin=12V
-
40
10
100
20
90
6
mA
mA
mA
Remote Off Input Current
With simulated source impedance of 10 µH, 5 Hz to
20 MHz. Use a 100 µF/100 V electrolytic capacitor
with ESR=1ohm max, at 200 KHz @ 25°C.
-
Input Reflected Ripple Current (rms)
Input Reflected Ripple Current (pk-pk)
-
50
5.6
5.6
5.2
5.4
5.8
5.8
5.4
5.7
No load
V
V
Turn-on Voltage Threshold
Turn-off Voltage Threshold
6
Full load, VDD_set=1.5V, VTT_set=0.75V
No load
5.6
5.8
Full load, VDD_set=1.5V, VTT_set=0.75V
CAUTION: This converter is not internally fused. An input line fuse must be used
NOTE: All specifications are typical at 25 C unless otherwise stated
tech.support@psbel.com
3
VRNE-60ED10/20 Series
PARAMETER
Boot Voltage
DESCRIPTION
MIN
TYP
1.5
MAX
UNIT
VDD
VTT
-
-
-
-
V
V
0.75
Vin=12 V, Io=0 A at 25°C ambient.
per VR12
VID
-
-
Output Voltage Set Point
Load Regulation
-
VDD
VTT
VDD
VTT
VDD
VTT
VDD
VTT
VDD
VTT
VDD
VTT
VDD
VTT
-
-
2
1
2
1
1
9
10
32
2
6
-
8
6
Vin=12 V, Io=0 A to 40 A
Vin=12 V, Io=0 A to 5 A
Io=40 A, Vin=6 V to 13.8 V
Io=5 A, Vin=6 V to 13.8 V
mV
-
8
Line Regulation
mV
mV
mV
mV
-
6
-5
-5
-
13
20
13
40
4
Working ambient temperature range
is from 0°C to 70°C.
Regulation Over Temperature
Output Ripple and Noise (Pk-Pk)
Output Ripple and Noise(RMS)
Vin=12 V, Io=40 A
Vin=12 V, Io=5 A
Vin=12 V, Io=40 A
Vin=12 V, Io= 5 A
Thermal design
-
-
-
7
0
0
0
0
40
5
-
Thermal design
A
Output Current Range
-
60
5
Peak current rating
Peak current rating
-
The output behaves in latch mode
when VDD rail OCP is triggered .2
The output behaves in hiccup mode
when VTT rail OCP is triggered. 3, 4
VDD
VTT
68
5
72
8
76
11
Output DC Current Limit
Rise time 5
A
VDD rail
VTT rail
VDD rail
VTT rail
0.2
0.2
1
-
0.8
0.8
2.2
2.2
ms
ms
-
1.6
1.6
Turn on Time 5
(Enable from remote ON/OFF)
1
VDD rail recommendation:
4 x 470 µF Polymer (ESR=7mR),
24 x 10 µF Ceramic (ESR=3.5mR),
2 x 100 µF Ceramic (ESR=3.5mR).
VTT rail recommendation:
VDD
VTT
-
-
2320
80
-
-
Output Capacitance
µF
8 x 10 µF Ceramic (ESR=3.5mR).
NOTE: 1. All specifications are typical at nominal input, full load at
25°C unless noted.
2. Only power recycle and re-enable can clear the OCP latch.
3. The interval in hiccup mode is about 56mS. The OCP exit
when the output current is lower than the limit.
4. Because Vtt output tracks half of Vdd output, the Vtt output
is also latched if Vdd rail OCP is triggered.
5. The turn on waveform with parameter measurement
locations is shown below.
North America
Asia-Pacific
Europe, Middle East
+1 408 785 5200
+86 755 298 85888
+353 61 225 977
© 2017 Bel Power Solutions & Protection
Rev. C1
4
VRNE-60ED10/20 Series
PARAMETER
DESCRIPTION
MIN
TYP
MAX
UNIT
The efficiency is measured at Vin=12V, IDD=20A, ITT=3A
and Ta=25°C.
-
85
-
%
Efficiency
VDD rail, single phase frequency
VTT rail
280
360
-
330
410
2
380
460
-
Switching Frequency
Address
kHz
-
VRNE-60ED10
VRNE-60ED20
-
4
-
address selection threshold
Weight
J1-27 maximum rating is 10V
0.5
-
1
1.5
-
V
g
23.6
2.49 x 0.26 x 1.29
63.25 x 6.60x 32.76
inch
mm
Dimensions (L × W ×H)
NOTE: All specifications are typical, at 25°C unless otherwise stated.
95.00%
90.00%
85.00%
80.00%
75.00%
70.00%
65.00%
60.00%
6.5V
12V
13.8V
4.00
10.00
20.00
30.00
40.00
OUTPUT CURRENT(A)
tech.support@psbel.com
5
VRNE-60ED10/20 Series
Maximum junction temperature of semiconductors derated to 120 ˚ C
Figure 1. Derating curve under normal input
Figure . Ripple and noise at full load, 12VDC input
1.5VDC/40A output and 0.75Vdc/5A output ,Ta=25 ˚C
NOTE: The first Trace is Vtt. The second Trace is Vdd.
North America
Asia-Pacific
Europe, Middle East
+1 408 785 5200
+86 755 298 85888
+353 61 225 977
© 2017 Bel Power Solutions & Protection
Rev. C1
6
VRNE-60ED10/20 Series
STARTUP TIME
Figure . Startup from on/off
Ch1: Vdd
Ch2: Vtt Ch3: on/off
NOTE: Test Condition: 12Vin, Idd=40A, Itt=5A, 25°C
tech.support@psbel.com
7
VRNE-60ED10/20 Series
This module has remote sense compensation feature. It can minimize the effects of resistance between module's output and load
in system layout and facilitates accurate voltage regulation at load terminals or other selected point.
1. The remote sense lines carries very little current and hence do not require a large cross-sectional area.
2. This module compensates for a maximum drop of 10% of the nominal output voltage.
3. If the unit is already trimmed up, the available remote sense compensation range should be correspondingly reduced. The total
voltage increased by trim and remote sense should not exceed 10% of the nominal output voltage.
4. When using remote sense compensation, all the resistance, parasitic inductance and capacitance of the system are incorporated
within the feedback loop of this module. The can make an effect on the module's compensation, affecting the stability and dyn.
5. Recommend the connection of remote sense compensation as below figure. There are a resistor RS+ (10 Ω) from Vo+ to Sense+
and a resistor RS- (10 Ω)) from Vo- to Sense- inside of this module.
6. If not using remote sense compensation, please connect sense directly to output at module's pin, that is, connect sense+ to Vo+
and sense- to Vo- at module's pin, the shorter the better. See below figure.
North America
Asia-Pacific
Europe, Middle East
+1 408 785 5200
+86 755 298 85888
+353 61 225 977
© 2017 Bel Power Solutions & Protection
Rev. C1
8
VRNE-60ED10/20 Series
1. Each rail has a power good indicator output in this module (J1-21, J1-22), to indicate this rail is ready to supply regulated voltage.
Power good pins use positive logic and are open collector.
2. For the VDD output, the signal is asserted high at the end of turn-on indicating that the output has reached the boot voltage.
3. For the VTT output, the signal is asserted high when the output is within 9% of normal output regulation point after soft start with 6%
hysteresis.
PARAMETER
Pull-up resistor
Pull-up voltage
DESCRIPTION
MIN
0.95
0.8
-
TYP
MAX
1.05
5.5
1
UNIT
kΩ
1
3.3
-
V
µA
mA
Vdd rail, PowerGood=3.3V
Vtt rail, PowerGood=0.8V
Sink current
-
-
23
tech.support@psbel.com
9
VRNE-60ED10/20 Series
VRNE-60ED10/20
NOTE: This module is recommended and compatible with Pb-Free Wave Soldering and must be soldered using a peak solder
temperature of no more than 260 ºC for less than 5 seconds.
North America
Asia-Pacific
Europe, Middle East
+1 408 785 5200
+86 755 298 85888
+353 61 225 977
© 2017 Bel Power Solutions & Protection
Rev. C1
10
VRNE-60ED10/20 Series
PIN
J1-1
J1-2
J1-3
J1-4
J1-5
J1-6
FUNCTION
Vout1-
PIN
FUNCTION
Vout1+
Vin-
PIN
FUNCTION
VDD_SEN-
PIN
J1-25
J1-26
J1-27
J1-28
J2-1
FUNCTION
VR_HOT#
ALERT#
J1-9
J1-17
J1-18
J1-19
J1-20
J1-21
J1-22
Vout1+
Vout1+
Vout1-
J1-10
J1-11
J1-12
J1-13
J1-14
VDD_SEN+
Vin-
VTT_SEN-
VDIO
Vin+
VTT_SEN+
VCLK
Vout1-
Vin+
VRRDY_VDD
support pin
support pin
Vout1+
Vout2-
VRRDY_VTT
J2-2
ENABLE (VRNE-60ED10)
No Pin (VRNE-60ED20)
No Pin (VRNE-60ED10)
ENABLE (VRNE-60ED20)
J1-7
J1-8
Vout1-
Vout1+
J1-15
J1-16
Vout2+
Vout2-
J1-23
J1-24
tech.support@psbel.com
11
VRNE-60ED10/20 Series
DATE
REVISION
CHANGES DETAIL
APPROVAL
J Yan
2012-5-14
2013-5-31
2013-12-18
PA
PB
PC
First release
Add detail information
Outline, VTT ripple, VTT start up, PG
J Yan
J Yan
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
North America
Asia-Pacific
Europe, Middle East
+1 408 785 5200
+86 755 298 85888
+353 61 225 977
© 2017 Bel Power Solutions & Protection
Rev. C1
相关型号:
VRP1-20E1A1
DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, ROHS COMPLIANT PACAKGE-8
BEL
VRP1-20E1A1G
DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, ROHS COMPLIANT PACAKGE-8
BEL
VRP1-20E2ACG
DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL
©2020 ICPDF网 联系我们和版权申明