XRSB-40U [BEL]

ISOLATED DC/DC CONVERTERS; 隔离式DC / DC转换器
XRSB-40U
型号: XRSB-40U
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

ISOLATED DC/DC CONVERTERS
隔离式DC / DC转换器

转换器
文件: 总13页 (文件大小:367K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
xRSB-40U Series  
RoHS Compliant  
Rev.A  
Isolated  
Input Under Voltage Lockout  
Output Over Voltage Shutdown  
OCP/SCP  
Fixed Frequency  
High Efficiency  
High Power Density  
Low Cost  
Over Temperature Protection  
Wide Input Voltage  
Output Voltage Trim  
Positive/Negative Remote Sense  
Basic Insulation  
Through Hole and SMT(Option)  
Input Over Voltage Protection  
Remote On/Off Logic (Option)  
Description  
The xRSB-40U series are isolated dc/dc converters that operate from a nominal 24 Vdc or 48 Vdc source. These  
units will provide up to 40 W of output power from an 18 Vdc - 75 Vdc wide input range. These units are designed  
to be highly efficient and low cost. Features include remote on/off, over current protection and under voltage  
lockout. These converters are provided in an industry standard sixteenth brick package.  
Part Selection  
Output  
Input Voltage  
Max. Output  
Current  
Max. Output  
Power  
Typical  
Efficiency  
Model Number  
Active Low  
Model Number  
Active High  
Voltage  
1.2 Vdc  
1.5 Vdc  
1.8 Vdc  
2.5 Vdc  
3.3 Vdc  
5.0 Vdc  
12 Vdc  
18 Vdc - 75 Vdc  
18 Vdc - 75 Vdc  
18 Vdc - 75 Vdc  
18 Vdc - 75 Vdc  
18 Vdc - 75 Vdc  
18 Vdc - 75 Vdc  
18 Vdc - 75 Vdc  
18 A  
16 A  
14 A  
12 A  
10 A  
8 A  
22 W  
24 W  
25 W  
30 W  
33 W  
40 W  
42 W  
82%  
84%  
85%  
86%  
87.5%  
87%  
85%  
xRSB-40UV2L  
xRSB-40UV5L  
xRSB-40UV8L  
xRSB-40U02L  
xRSB-40U03L  
xRSB-40U05L  
xRSB-40U12L  
xRSB-40UV20  
xRSB-40UV50  
xRSB-40UV80  
xRSB-40U025  
xRSB-40U033  
xRSB-40U050  
xRSB-40U120  
3.5 A  
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging. Replace”x” with “S” to  
indicate SMT package, or “0” to indicate through hole package.  
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.  
Absolute Maximum Ratings  
Parameter  
Input Voltage (continuous)  
Remote On/Off  
Min  
-0.3 V  
-0.3 V  
-
Typ  
Max  
80 V  
Notes  
-
-
-
-
-
18 V  
I/O Isolation Voltage  
Ambient Temperature  
Storage Temperature  
1500 V  
-40 °C  
-55 °C  
85 °C  
125 °C  
Input Specifications  
Parameter  
Min  
Typ  
Max  
Notes  
Input Voltage  
18 V  
48 V  
75 V  
Input Current (full load)  
Vo=1.2 V - 1.8 V  
Vo=2.5 V - 3.3 V  
Vo=5.0 V - 12 V  
-
-
-
-
-
-
2.5 A  
3.0 A  
3.5 A  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
Input Specifications (continued)  
Parameter  
Min  
Typ  
Max  
Notes  
Input Current (no load)  
-
60 mA  
120 mA  
Remote Off Input Current  
-
-
1 mA  
3 mA  
Tested with simulated source impedance of  
15 uH, 5 Hz to 20 MHz; use a 100 uF/100 V  
electrolytic capacitor with ESR=1 ohm max  
at 200 kHz at the input.  
Input Reflected Ripple Current (pk-pk)  
20 mA  
50 mA  
Input Reflected Ripple Current (rms)  
-
3 mA  
7 mA  
I2t Inrush Current Transient  
Turn On Voltage Threshold  
Turn Off Voltage Threshold  
-
0.01 A2s 0.02 A2s  
16.6 V  
16.2 V  
17.2 V  
16.8 V  
17.8 V  
17.4 V  
Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.  
Output Specifications  
Parameter  
Min  
Typ  
Max  
Notes  
Output Voltage Set Point  
Vo=1.2 V  
Vo=1.5 V  
Vo=1.8 V  
Vo=2.5 V  
Vo=3.3 V  
Vo=5.0 V  
Vo=12 V  
1.182 V  
1.478 V  
1.773 V  
2.463 V  
3.250 V  
4.925 V  
11.750 V  
1.2 V  
1.5 V  
1.8 V  
2.5 V  
3.3 V  
5.0 V  
12 V  
1.218 V  
1.523 V  
1.827 V  
2.538 V  
3.350 V  
5.075 V  
12.250 V  
Test conditions:  
Vin=48 V; Io=50%  
load  
Line Regulation  
Load Regulation  
±0.5 mV  
±1.0 mV  
±3.0 mV  
±4.0 mV  
±6.0 mV  
±3 mV  
±4 mV  
±8 mV  
±9 mV  
±15 mV  
Vo=1.2 V - 1.8 V  
Vo=2.5 V  
-
-
-
-
-
Vo=3.3 V  
Vo=5.0 V  
Vo=12 V  
±3 mV  
±4 mV  
±9 mV  
±5 mV  
±9 mV  
±18 mV  
Vo=1.2 - 2.5 V  
Vo=3.3 - 5.0 V  
Vo=12 V  
-
-
-
Regulation Over Temperature(-40 °C to +85 °C)  
Vo=1.2 V  
±4 mV  
±6 mV  
±9 mV  
±15 mV  
±20 mV  
±9 mV  
±14 mV  
±16 mV  
±30 mV  
±35 mV  
-
-
-
-
-
Vo=1.5 - 1.8 V  
Vo=2.5 - 3.3 V  
Vo=5.0 V  
Vo=12 V  
Output Current  
-
-
-
-
-
-
-
-
Vo=1.2 V  
Vo=1.5 V  
Vo=1.8 V  
Vo=2.5 V  
Vo=3.3 V  
Vo=5.0 V  
Vo=12 V  
0 A  
0 A  
0 A  
0 A  
0 A  
0 A  
0 A  
18 A  
16 A  
14 A  
12 A  
10 A  
8 A  
3.5 A  
Short Circuit Surge Transient  
-
0.5 A2s  
1 A2s  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
Output Specifications (continued)  
Parameter  
Min  
Typ  
Max  
Notes  
Current Limit Threshold  
Vo=1.2 V  
Vo=1.5 V  
Vo=1.8 V  
Vo=2.5 V  
Vo=3.3 V  
Vo=5.0 V  
Vo=12 V  
21 A  
19 A  
17 A  
14 A  
11 A  
8.8 A  
4.2 A  
25 A  
22 A  
20 A  
17 A  
14 A  
10 A  
5 A  
29 A  
26 A  
23 A  
20 A  
16 A  
12.5 A  
6 A  
Ripple and Noise (rms)  
Ripple and Noise (pk-pk)  
Vo=1.2 V - 1.8 V  
Vo=2.5 V  
-
-
-
-
-
6 mV  
10 mV  
12 mV  
25 mV  
30 mV  
12 mV  
20 mV  
25 mV  
50 mV  
55 mV  
Vo=3.3 V  
Vo=5.0 V  
Vo=12 V  
Tested at 0-20 MHz  
BW, with a 1 uF  
ceramic capacitor and  
a 10 uF Tantalum  
capacitor at the  
output.  
Vo=1.2 V - 1.8 V  
Vo=2.5 V  
-
-
-
-
-
40 mV  
45 mV  
55 mV  
70 mV  
90 mV  
70 mV  
80 mV  
90 mV  
120 mV  
180 mV  
Vo=3.3 V  
Vo=5.0 V  
Vo=12 V  
Turn on Time  
-
-
25 mS  
0%  
50 mS  
5%  
Overshoot at Turn on  
Output Capacitance  
-
-
-
-
-
-
-
-
Vo=1.2 V  
Vo=1.5 V  
Vo=1.8 V  
Vo=2.5 V  
Vo=3.3 V  
Vo=5.0 V  
Vo=12 V  
470 uF  
470 uF  
470 uF  
470 uF  
330 uF  
150 uF  
10 uF  
15000 uF  
10000 uF  
10000 uF  
5600 uF  
4700 uF  
2200 uF  
220 uF  
Recommend to use  
AVX TPS series  
Tantalum capacitor as  
min capacitor.  
Transient Response  
Overshoot  
Settling Time  
Overshoot  
Settling Time  
Overshoot  
Settling Time  
Overshoot  
Settling Time  
Overshoot  
Settling Time  
Overshoot  
Settling Time  
Overshoot  
Settling Time  
Overshoot  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
60 mV  
80 uS  
60 mV  
80 uS  
60 mV  
80 uS  
60 mV  
80 uS  
180 mV  
80 uS  
180 mV  
80 uS  
250 mV  
100 uS  
250 mV  
100 uS  
400 mV  
150 uS  
400 mV  
150 uS  
110 mV  
150 uS  
110 mV  
150 uS  
110 mV  
150 uS  
110 mV  
150 uS  
250 mV  
150 uS  
250 mV  
150 uS  
350 mV  
200 uS  
350 mV  
200 uS  
650 mV  
300 uS  
650 mV  
300 uS  
25% ~ 50%  
Max Load  
Vo=1.2 V  
Vo=1.5 -1.8 V  
Vo=2.5 -3.3 V  
Vo=5.0 V  
50% ~ 25%  
Max Load  
25% ~ 50%  
Max Load  
50% ~ 25%  
Max Load  
Test conditions: di/dt  
= 0.1 A/uS, Vin=48 V,  
with a 1 uF ceramic  
capacioor and a Min  
Capacitance of  
25% ~ 50%  
Max Load  
50% ~ 25%  
Max Load  
Tantalum capacitor at  
the output  
25% ~ 50%  
Max Load  
50% ~ 25%  
Max Load  
Settling Time  
Overshoot  
Settling Time  
Overshoot  
25% ~ 50%  
Max Load  
Vo=12 V  
50% ~ 25%  
Max Load  
Settling Time  
Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
General Specifications  
Parameter  
Min  
Typ  
Max  
Notes  
Efficiency  
Vo=1.2 V  
Vo=1.5 V  
Vo=1.8 V  
Vo=2.5 V  
Vo=3.3 V  
Vo=5.0 V  
Vo=12 V  
78%  
79%  
81%  
83%  
85%  
85%  
83%  
82%  
84%  
85%  
86%  
87.5%  
87%  
85%  
-
-
-
-
-
-
Vin=48 V, full load  
Switching Frequency  
Vo=1.2 V -12 V  
Vo=1.8 V  
450 kHz  
500 kHz  
500 kHz  
550 kHz  
550 kHz  
600 kHz  
Isolation Capacitance  
-
-
3900 pF  
-
-
Over Temperature Protection  
Output Voltage Trim Range  
125 °C  
90% Vo  
-
-
110% Vo  
160% Vo  
Test conditions: Vin=48 V, full load and  
short the feedback optocoupler.  
Calculated Per Bell Core SR-332 (IO =  
Nominal; Ta = 25 °C)  
Over Voltage Protection  
MTBF  
130% Vo  
TBD  
1.3 x 0.9 x 0.446  
33.0 x 22.9 x 11.34  
SRSB-40Uxxx  
Dimensions  
Inches (L × W × H)  
Millimeters (L × W × H)  
1.3 x 0.9 x 0.460  
33.0 x 22.9 x 11.39  
0RSB-40Uxxx  
Weight  
-
14 g  
-
Note: All specifications are typical at 25 °C unless otherwise stated.  
Control Specifications  
Parameter  
Min  
Typ  
Max  
Notes  
Remote On/Off  
Signal Low (Unit On)  
Signal High (Unit Off)  
Signal Low (Unit Off)  
Signal High (Unit On)  
Current Sink  
-0.3 V  
2.4 V  
-0.3 V  
2.4 V  
0 mA  
-
-
-
-
-
0.8 V  
18 V  
0.8 V  
18 V  
1 mA  
Active Low  
When Remote On/Off pin is  
open, for active low option, unit  
is off; for active high option, unit  
is on  
Active High  
-
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
Output Trim Equations  
Equations for calculating the trim resistor are shown below (Unit: k). The Trim Down resistor should be  
connected between the Trim pin and Ground pin. The Trim Up resistor should be connected between the Trim pin  
and the Vout. Only one of the resistors should be used for any given application.  
1) Trim Equations for Vo=1.2 V  
Vo  
511  
Rtrimdown  
=
10.22  
Module  
Trim  
GND  
delta  
Rtrimdown  
(100 + delta)Vo 5.11313  
0.6125delta  
Rtrimup  
=
10.22  
Note:  
(
)
Vo _ req Vo  
Vo  
[ ]  
×100 %  
delta =  
Vo  
Rtrimup  
Module  
Trim  
GND  
Vo_req=Desired (trimmed) output voltage [V]  
2) Trim Equations for Vo=1.5 V - 12 V  
511  
Vo=1.202 V  
Rtrimdown  
=
10.22  
delta  
(100 + delta)Vo511626  
1.225delta  
Rtrimup  
=
10.22  
Note:  
(
Vo _ req Vo  
)
delta =  
×100  
%
[ ]  
Vo  
Vo_req=Desired (trimmed) output voltage [V]  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
Efficiency Data  
90%  
85%  
80%  
90%  
85%  
80%  
75%  
18V  
24V  
48V  
75V  
18V  
75%  
24V  
70%  
48V  
75V  
70%  
65%  
60%  
55%  
50%  
65%  
60%  
55%  
50%  
1.00  
2.50  
5.00  
7.50  
10.00  
1.80  
4.50  
9.00  
13.50  
18.00  
OUTPUT CURRENT (A)  
OUTPUT CURRENT (A)  
xRSB-40UV2x  
xRSB-40U03x  
90%  
85%  
80%  
75%  
70%  
65%  
60%  
55%  
50%  
90%  
85%  
80%  
75%  
70%  
65%  
60%  
55%  
50%  
18V  
24V  
48V  
75V  
18V  
24V  
48V  
75V  
0.80  
2.00  
4.00  
6.00  
8.00  
0.35  
0.88  
1.75  
2.63  
3.50  
OUTPUT CURRENT (A)  
OUTPUT CURRENT (A)  
xRSB-40U05x  
xRSB-40U12x  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
Thermal Derating Curves  
Vin=48 Vdc  
xRSB-40UV2x  
xRSB-40U03x  
xRSB-40U05x  
xRSB-40U12x  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
Thermal Derating Curves (continued)  
Vin=24 Vdc  
xRSB-40UV2x  
xRSB-40U03x  
xRSB-40U05x  
xRSB-40U12x  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
Ripple and Noise Waveforms  
48 Vdc input, 1.2 Vdc output  
48 Vdc input, 3.3 Vdc output  
48 Vdc input, 5.0 Vdc output  
48 Vdc input, 12 Vdc output  
Note: Ripple and noise at full load, with a 1 uF ceramic capacioor and a Min Capacitance of Tantalum capacitor at  
the output, Ta=25 deg C.  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
Transient Response Waveforms  
Vout=1.2 V 50% to 25% Load Transients  
Vout=3.3 V 50% to 25% Load Transients  
Vout=5.0 V 50% to 25% Load Transients  
Vout=1.2 V 25% to 50% Load Transients  
Vout=3.3 V 25% to 50% Load Transients  
Vout=5.0 V 25% to 50% Load Transients  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
Transient Response Waveforms (continued)  
Vout=12 V 50% to 25% Load Transients  
Vout=12 V 25% to 50% Load Transients  
Note: Transient Response at Vin=48 V, di/dt=0.1 A/uS, with a 1 uF ceramic capacioor and a Min Capacitance of  
Tantalum capacitor at the output, Ta=25 deg C.  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
SMT Package (SRSB-40Uxxx)  
Pin Connections  
Pin  
Function  
1
2
3
4
5
6
7
8
Vin (+)  
Remote On/Off  
Vin (-)  
Vout (-)  
Remote Sense (-)  
Trim  
Remote Sense (+)  
Vout (+)  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick  
Through Hole Package (0RSB-40Uxxx)  
Pin Connections  
Pin  
Function  
1
Vin (+)  
2
Remote On/Off  
Vin (-)  
3
4
Vout (-)  
5
Remote Sense (-)  
Trim  
6
7
Remote Sense (+)  
Vout (+)  
8
RoHS Compliance  
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and  
other hazardous substances from electronic products.  
©2007 Bel Fuse Inc. Specifications subject to change without notice. 012907  
CORPORATE  
FAR EAST  
EUROPE  
Bel Fuse Inc.  
Bel Fuse Ltd.  
Bel Fuse Europe Ltd.  
206 Van Vorst Street  
Jersey City, NJ 07302  
Tel 201-432-0463  
Fax 201-432-9542  
www.belfuse.com  
8F/ 8 Luk Hop Street  
San Po Kong  
Kowloon, Hong Kong  
Tel 852-2328-5515  
Fax 852-2352-3706  
www.belfuse.com  
Preston Technology Management Centre  
Marsh Lane, Suite G7, Preston  
Lancashire, PR1 8UD, U.K.  
Tel 44-1772-556601  
Fax 44-1772-888366  
www.belfuse.com  

相关型号:

XRSB-40U025

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL

XRSB-40U02L

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL

XRSB-40U033

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL

XRSB-40U03L

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL

XRSB-40U050

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL

XRSB-40U05L

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL

XRSB-40U120

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL

XRSB-40U12L

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL

XRSB-40UV20

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL

XRSB-40UV2L

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL

XRSB-40UV50

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL

XRSB-40UV5L

ISOLATED DC/DC CONVERTERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BEL