ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
Member of the
Family
Features
•
RoHS lead free and lead-solder-exempt products are
available
•
•
•
•
•
Wide input voltage range: 3V–14V
High continuous output current: 7A
Wide programmable output voltage range: 0.5V–5.5V
Active digital current share
Single-wire serial communication bus for frequency
synchronization, programming, and monitoring
•
•
Optimal voltage positioning with programmable slope
of the VI line
Applications
•
Low voltage, high density systems with
Intermediate Bus Architectures (IBA)
Overcurrent, overvoltage, undervoltage, and
overtemperature protection with programmable
thresholds and types
•
Point-of-load regulators for high performance DSP,
FPGA, ASIC, and microprocessor applications
•
•
•
Programmable fixed switching frequency 0.5-1.0MHz
Programmable turn-on and turn-off delays
•
•
Desktops, servers, and portable computing
Broadband, networking, optical, and
communications systems
Programmable turn-on and turn-off voltage slew rates
with tracking protection
•
Active memory bus terminators
•
•
•
•
•
•
Programmable feedback loop compensation
Power Good signal with programmable limits
Programmable fault management
Benefits
•
•
•
Integrates digital power conversion with intelligent
power management
Start up into the load pre-biased up to 100%
Full rated current sink
Eliminates the need for external power
management components
Real time voltage, current, and temperature
measurements, monitoring, and reporting
Completely programmable via industry-standard
I2C communication bus
•
•
•
Small footprint SMT package: 12.5x22.2mm
Extremely low profile of 6.5mm
•
•
One part that covers all applications
Reduces board space, system cost and
complexity, and time to market
Compatible with conventional pick-and-place
equipment
•
•
Wide operating temperature range
UL 60950-1/CSA 22.2 No. 60950-1-07 Second
Edition, IEC 60950-1: 2005, and EN 60950-1:2006
Description
Power-One’s point-of-load converters are recommended for use with regulated bus converters in an Intermediate
Bus Architecture (IBA). The ZY7007 is an intelligent, fully programmable step-down point-of-load DC-DC module
integrating digital power conversion and intelligent power management. When used with ZM7300 Series Digital
Power Managers, the ZY7007 completely eliminates the need for external components for sequencing, tracking,
protection, monitoring, and reporting. All parameters of the ZY7007 are programmable via the industry-standard
I2C communication bus and can be changed by a user at any time during product development and service.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 1 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
Reference Documents:
•
•
•
•
ZM7300 Digital Power Manager Data Sheet
ZM7300 PrgManual - Digital Power Manager Programming Manual
Power-One I2C GEN II Graphical User Interface
ZM00056-KIT USB to I2C Adapter Kit. User Manual
1. Ordering Information
ZY
70
07
x
y
–
zz
Output voltage setpoint
accuracy:
L – 1.2% or 20mV,
whichever is greater.
H1 – 1.0% or 10mV,
whichever is greater
RoHS compliance:
No suffix - RoHS
compliant with Pb
solder exemption2
G - RoHS compliant
for all six substances
Packaging Option3:
T1 - 500pcs T&R
T2 – 100pcs T&R
T3 – 50pcs T&R
Q1 – 1pc sample for
evaluation only
Product
family:
Z-One
Series:
Intelligent
POL
Output
Current:
7A
Dash
Module
Converter
______________________________________
1
Contact factory for availability.
2
The solder exemption refers to all the restricted materials except lead in solder. These materials are Cadmium (Cd), Hexavalent chromium
(Cr6+), Mercury (Hg), Polybrominated biphenyls (PBB), Polybrominated diphenylethers (PBDE), and Lead (Pb) used anywhere except in
solder.
3
Packaging option is used only for ordering and not included in the part number printed on the POL converter label.
4
The evaluation board is available in only one configuration: ZM7300-KIT-HKS.
Example: ZY7007HG-T2: A 100-piece reel of RoHS compliant POL converters with the output voltage setpoint of
1.0% or 10mV, whichever is greater. Each POL converter is labeled ZY7007HG.
2. Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-
term reliability, and cause permanent damage to the converter.
Parameter
Operating Temperature
Input Voltage
Conditions/Description
Controller case temperature
250ms Transient
Min
Max
105
15
Units
°C
-40
VDC
ADC
Output Current
(See Output Current De-rating Curves)
-7
7
3. Environmental and Mechanical Specifications
Parameter
Ambient Temperature Range
Storage Temperature (Ts)
Weight
Conditions/Description
Min
Nom
Max
85
Units
-40
-55
°C
°C
125
8
grams
MHrs
MTBF
Calculated Per Telcordia Technologies SR-332
6.24
ZY7007
ZY7007G
220
260
°C
°C
Peak Reflow Temperature
245
Lead Plating
ZY7007 and ZY7007G
ZY7007 and ZY7007G
100% Matte Tin
3
Moisture Sensitivity Level
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 2 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
4. Electrical Specifications
Specifications apply at the input voltage from 3V to 14V, output load from 0 to 7A, ambient temperature from -40°C to 85°C,
100µF output capacitance, and default performance parameters settings unless otherwise noted.
4.1 Input Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
VDC
At VIN<4.75V, VLDO pin needs to be
connected to an external voltage source
higher than 4.75V
Input voltage (VIN)
3
14
Input Current (at no load)
50
mADC
VIN≥4.75V, VLDO pin connected to VIN
Undervoltage Lockout (VLDO
connected to VIN)
Ramping Up
Ramping Down
4.2
3.75
VDC
VDC
Undervoltage Lockout (VLDO
connected to VAUX=5V)
Ramping Up
Ramping Down
3.0
2.5
VDC
VDC
External Low Voltage Supply
VLDO Input Current
Connect to VLDO pin when VIN<4.75V
4.75
14
VDC
Current drawn from the external low
voltage supply at VLDO=5V
50
mADC
4.2 Output Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
Programmable1
0.5
5.5
VDC
VDC
Output Voltage Range (VOUT
)
Default (no programming)
0.5
VIN=12V, IOUT=0.5*IOUT MAX
FSW=500kHz, room temperature
,
Output Voltage Setpoint Accuracy
(See Ordering Information)
Output Current (IOUT
Line Regulation
)
VIN MIN to VIN MAX
-72
7
ADC
VIN MIN to VIN MAX
0 to IOUT MAX
±0.3
±0.3
%VOUT
%VOUT
Load Regulation
Dynamic Regulation
Peak Deviation
Settling Time
Slew rate 2.5A/µs, 50 - 100% load step
COUT=220µF, FSW=1MHz
mV
µs
50
50
to 10% of peak deviation
VIN=5.0V, VOUT=0.5V, FSW=500kHz
VIN=5.0V, VOUT=2.5V, FSW=500kHz
VIN=13.2V, VOUT=0.5V, FSW=500kHz
VIN=13.2V, VOUT=2.5V, FSW=500kHz
VIN=13.2V, VOUT=5.0V, FSW=500kHz
VIN=13.2V, VOUT=5.0V, FSW=1MHz
15
15
20
25
40
20
mV
mV
mV
mV
mV
mV
Output Voltage Peak-to-Peak
Ripple and Noise
BW=20MHz
Full Load
Temperature Coefficient
Switching Frequency
VIN=12V, IOUT=0.5*IOUT MAX
20
ppm/°C
Default
500
kHz
kHz
%
%
Programmable, 250kHz steps
Default
Programmable, 1.56% steps
500
0
1,000
95
90.5
Duty Cycle Limit
1
ZY7007 is a step-down converter, thus the output voltage is always lower than the input voltage as show in Figure 1.
At the negative output current (bus terminator mode) efficiency of the ZY7007 degrades resulting in increased internal power dissipation.
2
Therefore maximum allowable negative current under specific conditions is 20% lower than the current determined from the derating curves
shown in paragraph 5.5.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 3 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
VOUT [V]
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
Minimum Load 0.25A
3.0
3.3
6.25
5.5
VIN [V]
2.0
4.0
8.0
6.0
10.0
12.0
14.0
Figure 1. Output Voltage as a Function of Input Voltage and Output Current
4.3 Protection Specifications
Parameter
Conditions/Description
Output Overcurrent Protection
Min
Nom
Max
Units
Default
Programmable
Non-Latching, 130ms period
Latching/Non-Latching
Type
Default
Programmable in 11 steps
180
180
%IOUT
%IOUT
Threshold
60
Threshold Accuracy
-25
25
%IOCP.SET
Output Overvoltage Protection
Default
Programmable
Non-Latching, 130ms period
Latching/Non-Latching
Type
Default
Programmable in 10% steps
130
%VO.SET
%VO.SET
Threshold
1101
-2
130
2
Threshold Accuracy
Measured at VO.SET=2.5V
%VOVP.SET
From instant when threshold is exceeded until
the turn-off command is generated
Delay
6
μs
___________________
1
Minimum OVP threshold is 1.0V
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 4 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
Output Undervoltage Protection
Default
Programmable
Non-Latching, 130ms period
Latching/Non-Latching
Type
Default
Programmable in 5% steps
75
%VO.SET
%VO.SET
Threshold
Threshold Accuracy
Delay
75
-2
85
2
Measured at VO.SET=2.5V
%VUVP.SET
From instant when threshold is exceeded until
the turn-off command is generated
6
μs
Over Temperature Protection
Default
Programmable
Non-Latching, 130ms period
Latching/Non-Latching
Type
Turn Off Threshold
Turn On Threshold
Threshold Accuracy
Delay
Temperature is increasing
130
120
5
°C
°C
°C
μs
Temperature is decreasing after the module was
shut down by OTP
-5
From instant when threshold is exceeded until
the turn-off command is generated
6
Tracking Protection (when Enabled)
Default
Programmable
Disabled
Type
Latching/Non-Latching, 130ms period
Threshold
Enabled during output voltage ramping up
mVDC
±250
Threshold Accuracy
-50
50
mVDC
From instant when threshold is exceeded until
the turn-off command is generated
Delay
6
μs
Over Temperature Warning
Threshold
Threshold Accuracy
Hysteresis
Always enabled, reported in Status register
120
°C
°C
°C
-5
5
3
6
From instant when threshold is exceeded until
the warning signal is generated
Delay
μs
Power Good Signal (PGOOD pin)
VOUT is inside the PG window
VOUT is outside the PG window
High
Low
Logic
N/A
Default
Programmable in 5% steps
90
%VO.SET
%VO.SET
Lower Threshold
Upper Threshold
Delay
90
-2
95
2
110
6
%VO.SET
μs
From instant when threshold is exceeded until
status of PG signal changes
Threshold Accuracy
Measured at VO.SET=2.5V
%VO.SET
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 5 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
4.4 Feature Specifications
Parameter
Conditions/Description
Current Share
Min
Nom
Max
Units
Type
Active, Single Line
Maximum Number of Modules
Connected in Parallel
IOUT MIN=0
4
Current Share Accuracy
IOUT MIN≥20%*IOUT NOM
±20
%IOUT
Interleave
Default
0
Degree
degree
Interleave (Phase Shift)
0
348.75
Programmable in 11.25° steps
Sequencing
Default
Programmable in 1ms steps
0
ms
ms
Turn ON Delay
Turn OFF Delay
0
0
255
Default
Programmable in 1ms steps
0
ms
ms
63
Tracking
Default
Programmable in 7 steps
0.1
V/ms
V/ms
Turn ON Slew Rate
Turn OFF Slew Rate
0.1
8.331
Default
Programmable in 7 steps
-0.1
V/ms
V/ms
-0.1
-8.331
Optimal Voltage Positioning
Default
Programmable in 7 steps
0
mV/A
mV/A
Load Regulation
0
13
Feedback Loop Compensation
Zero1 (Effects phase lead and
increases gain in mid-band)
Programmable
0.05
0.05
0.05
1
50
50
kHz
kHz
kHz
kHz
kHz
Zero 2 (Effects phase lead and
increases gain in mid-band)
Programmable
Programmable
Programmable
Pole 1 (Integrator Pole, effects
loop gain)
50
Pole 2 (Effects phase lag and
limits gain in mid-band)
1000
1000
Pole 3 (High frequency low- pass
filter to limit PWM noise)
Programmable
Monitoring
1
-2%VOUT
– 1 LSB
2%VOUT
+ 1 LSB
Voltage Monitoring Accuracy
Current Monitoring Accuracy
1 LSB=22mV
mV
20%*IOUT NOM < IOUT < IOUT NOM
-20
-5
+20
+5
%IOUT
Temperature Monitoring Accuracy Junction temperature of POL controller
°C
Remote Voltage Sense (+VS and –VS pins)
Between +VS and VOUT
Voltage Drop Compensation
Voltage Drop Compensation
300
100
mV
mV
Between -VS and PGND
___________________
1
Achieving fast slew rates under specific line and load conditions may require feedback loop adjustment
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 6 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
4.5 Signal Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
VDD
Internal supply voltage
3.15
3.3
3.45
V
SYNC/DATA Line (SD pin)
ViL_sd
ViH_sd
LOW level input voltage
HIGH level input voltage
-0.5
0.3 x VDD
VDD + 0.5
V
V
0.75 x
VDD
0.25 x
VDD
0.45 x
VDD
Vhyst_sd
Hysteresis of input Schmitt trigger
V
VoL
Tr_sd
LOW level sink current @ 0.5V
Maximum allowed rise time 10/90%VDD
Added node capacitance
14
60
300
10
mA
ns
Cnode_sd
Ipu_sd
5
pF
Pull-up current source at Vsd=0V
Clock frequency of external SD line
0.3
1.0
525
mA
kHz
Freq_sd
475
% of clock
cycle
% of clock
cycle
Tsynq
T0
Sync pulse duration
22
72
28
78
Data=0 pulse duration
Inputs: ADDR0…ADDR4, EN, IM
ViL_x
ViH_x
LOW level input voltage
HIGH level input voltage
-0.5
0.3 x VDD
VDD+0.5
0.3 x VDD
V
V
V
0.7 x VDD
0.1 x VDD
Vhyst_x
Hysteresis of input Schmitt trigger
External pull down resistance
ADDRX forced low
RdnL_ADDR
10
kOhm
Power Good and OK Inputs/Outputs
Iup_PG
Iup_OK
ViL_x
Pull-up current source input forced low PG
Pull-up current source input forced low OK
LOW level input voltage
25
175
110
725
μA
μA
V
-0.5
0.3 x VDD
VDD+0.5
0.3 x VDD
20
ViH_x
Vhyst_x
IoL
HIGH level input voltage
0.7 x VDD
0.1 x VDD
4
V
Hysteresis of input Schmitt trigger
LOW level sink current at 0.5V
V
mA
Current Share Bus (CS pin)
Pull-up current source at VCS = 0V
Iup_CS
ViL_CS
0.84
-0.5
3.1
mA
V
LOW level input voltage
HIGH level input voltage
0.3 x VDD
0.75 x
VDD
ViH_CS
VDD+0.5
V
V
0.25 x
VDD
0.45 x
VDD
Vhyst_CS
Hysteresis of input Schmitt trigger
IoL
LOW level sink current at 0.5V
14
60
mA
ns
Tr_CS
Maximum allowed rise time 10/90% VDD
100
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 7 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
5. Typical Performance Characteristics
5.1 Efficiency Curves
94
92
90
88
86
84
82
80
78
95
90
85
80
75
70
65
60
Vo=1.2V
Vo=3.3V
Vo=2.5V
Vo=5.0V
76
74
Vo=0.5V
Vo=1.2V
4
Vo=2.5V
6
55
0
1
2
3
4
5
6
7
0
1
2
3
5
7
Output Current, A
Output Current, A
Figure 4. Efficiency vs. Load. Vin=9.6V, Fsw=500kHz
Figure 2. Efficiency vs. Load. Vin=3.3V, Fsw=500kHz
92
90
88
86
84
82
80
78
76
74
95
90
85
80
75
70
65
60
Vo=1.2V
Vo=3.3V
Vo=2.5V
Vo=5.0V
72
70
Vo=0.5V
Vo=2.5V
Vo=1.2V
Vo=3.3V
0
1
2
3
4
5
6
7
Output Current, A
0
1
2
3
4
5
6
7
Output Current, A
Figure 5. Efficiency vs. Load. Vin=12V, Fsw=500kHz
Figure 3. Efficiency vs. Load. Vin=5V, Fsw=500kHz
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 8 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
95
90
85
80
75
70
65
60
55
5.2 Turn-On Characteristics
Vin=5V
Vin=3.3V
Vin=12V
Vin=9.6V
0.5
1.5
2.5
3.5
4.5
5.5
Output Voltage, V
Figure 8. Tracking Turn-On. Rising Slew Rate is Programmed
Figure 6. Efficiency vs. Output Voltage, Iout=7A, Fsw=500kHz
at 0.5V/ms.
Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 – V3
90
85
80
75
70
65
60
55
Vo=0.5V
Vo=1.2V
Vo=2.5V
50
3
4
5
6
7
8
9
10 11 12 13 14
Figure 9. Turn-On with Different Rising Slew Rates.
Rising Slew Rates are Programmed as follows: V1-
1V/ms, V2-0.5V/ms, V3-0.2V/ms.
Input Voltage, V
Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 – V3
Figure 7. Efficiency vs. Input Voltage. Iout=7A, Fsw=500kHz
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 9 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
5.3 Turn-Off Characteristics
Figure 10. Sequenced Turn-On. Rising Slew Rate is
Programmed at 1V/ms. V2 Delay is 2ms, V3 delay
is 4ms. Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 – V3
Figure 12. Tracking Turn-Off. Falling Slew Rate is
Programmed at 0.5V/ms.
Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 – V3
Figure 11. Turn On into Prebiased Load. V3 is Prebiased by
V2 via a Diode.
Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 – V3
Figure 13. Turn-Off with Tracking and Sequencing. Falling
Slew Rate is Programmed at 0.5V/ms.
Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 – V3
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 10 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
5.4 Transient Response
The pictures below show the deviation of the output
voltage in response to the 50-100-50% step load at
2.5A/μs. In all tests the POL converters were
switching at 1MHz and had 10 x 22μF ceramic
capacitors connected across the output pins.
Bandwidth of the feedback loop was programmed for
faster transient response.
Figure 16. Vin=5V, Vout=2.5V, BW~40kHz
Figure 14. Vin=12V, Vout=5V, BW~50kHz
Figure 17. Vin=5V, Vout=1V, BW~40kHz
Figure 15. Vin=12V, Vout=1V, BW~40kHz
Figure 18. Vin=3.3V, Vout=1V, BW~40kHz
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 11 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
5.5 Thermal De-rating Curves
Figure 19. Thermal Derating Curves. Vin=12V, Vout=5.0V, Fsw=500kHz
7
6.5
6
5.5
5
4.5
4
3.5
3
0LFM
100LFM
55
200LFM
400LFM
600LFM
45
65
Ambient Temperature, Degree C
75
85
Figure 20. Thermal Derating Curves. Vin=14V, Vout=5.0V, Fsw=500kHz
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 12 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
7
6.5
6
5.5
5
4.5
4
3.5
3
0LFM
100LFM
200LFM
65
400LFM
75
600LFM
45
55
85
Ambient Temperature, Degree 'C
Figure 21. Thermal Derating Curves. Vin=12V, Vout=5.0V, Fsw=1MHz
7
6.5
6
5.5
5
4.5
4
3.5
3
0LFM
100LFM
55
200LFM
65
400LFM
600LFM
45
75
85
Ambient Temperature, Degree 'C
Figure 22. Thermal Derating Curves. Vin=14V, Vout=5.0V, Fsw=1MHz
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 13 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
6. Typical Application
Intermediate Voltage Bus
SD
I2C
OK_C
OK_B
OK_A
DPM
CS
ZY7007
ZY7007
ZY7007
ZY7007
ADDR
ADDR
ADDR
ADDR
V1
V2
V3
Figure 23. Block Diagram of Typical Multiple Output Application with Digital Power Manager and I2C Interface
The block diagram of a typical application of ZY7007 point-of-load converters (POL) is shown in Figure 23. The
system includes multiple POLs and a ZM7300 series Digital Power Manager (DPM). All POLs are connected to the
DPM and to each other via a single-wire SD (sync/data) line. The line provides synchronization of all POLs to the
master clock generated by the DPM and simultaneously performs bidirectional data transfer between POLs and
the DPM. Each POL has a unique 5-bit address programmed by grounding respective address pins. To enable the
current share, CS pins of POLs connected in parallel are linked together.
There are three groups of POLs in the application, groups A, B, and group C. A group is defined as a number of
POLs interconnected via OK pins. Grouping of POLs enables users to program, control, and monitor multiple
POLs simultaneously and execute advanced fault management schemes.
The complete schematic of the application is shown in Figure 24.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 14 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
Figure 24. Complete Schematic of the Application Shown in Figure 23. Intermediate Bus Voltage is from 4.75V to 13.2V.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 15 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
7. Pin Assignments and Descriptions
Pin
Name
Pin
Pin
Buffer
Type
Pin Description
Notes
Number Type
Connect to an external voltage source higher than
4.75V, if VIN<4.75V. Connect to VIN, if VIN≥4.75V
VLDO
1
P
Low Voltage Dropout
NC
2
3
4
5
6
7
8
9
Not Used
Leave floating
NC
Not Used
Leave floating
NC
Not Used
Leave floating
ADDR0
ADDR1
ADDR2
ADDR3
ADDR4
I
I
I
I
I
PU
PU
PU
PU
PU
POL Address Bit 0
POL Address Bit 1
POL Address Bit 2
POL Address Bit 3
POL Address Bit 4
Tie to PGND for 0 or leave floating for 1
Tie to PGND for 0 or leave floating for 1
Tie to PGND for 0 or leave floating for 1
Tie to PGND for 0 or leave floating for 1
Tie to PGND for 0 or leave floating for 1
Connect to CS pins of other Z-POLs connected in
parallel
CS
10
I/O
PU
Current Share
TRIM
PGOOD
SD
11
12
13
Not Used
Power Good
Sync/Data Line
Leave floating
I/O
I/O
PU
PU
Connect to SD pin of DPM
Connect to OK pin of other Z-POLs and/or DPM.
Leave floating, if not used
OK
14
I/O
PU
Fault/Status Condition
EN
VREF
IM
15
16
Connect to PGND
Not Used
Connect to PGND
Leave floating
Leave floating
Leave floating
17
Not Used
NC
18
Not Used
VOUT
+VS
PGND
-VS
19-23
24
P
I
Output Voltage
Positive Voltage Sense
Power Ground
Negative Voltage Sense
Input Voltage
PU
PU
Connect to the positive point close to the load
Connect to the negative point close to the load
25-30
31
P
I
VIN
32-36
P
Legend: I=input, O=output, I/O=input/output, P=power, A=analog, PU=internal pull-up
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 16 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
ZY7007 converters can be programmed using the
Graphical User Interface or directly via the I2C bus by
using high and low level commands as described in
the ”ZM7300 Programming Manual”.
8. Programmable Features
Performance parameters of ZY7007 POL converters
can be programmed via the industry standard I2C
communication
bus
without
replacing
any
components or rewiring PCB traces. Each parameter
has a default value stored in the volatile memory
registers detailed in Table 1. The setup registers 00h
through 14h are programmed at the system power-
up. When the user programs new performance
parameters, the values in the registers are
overwritten. Upon removal of the input voltage, the
default values are restored.
ZY7007 parameters can be reprogrammed at any
time during the system operation and service except
for the digital filter coefficients, the switching
frequency and the duty cycle limit, that can only be
changed when the POL is turned off.
8.1 Output Voltage
The output voltage can be programmed in the POL
Output Configure window shown in the Figure 25 or
directly via the I2C bus by writing into the VOS
register shown in Figure 26.
Table 1. ZY7007 Memory Registers
Register
Content
Address
PC1
PC2
PC3
DON
DOF
TC
Protection Configuration 1
Protection Configuration 2
Protection Configuration 3
Turn-On Delay
00h
01h
02h
05h
06h
03h
04h
Turn-Off Delay
Tracking Configuration
Interleave Configuration and
Frequency Selection
INT
RUN
ST
VOS
CLS
DCL
B1
RUN Register
Status Register
15h
16h
07h
08h
09h
0Ah
Output Voltage Setpoint
Current Limit Setpoint
Duty Cycle Limit
Dig Controller Denominator z-1
Coefficient
B2
Dig Controller Denominator z-2
Coefficient
0Bh
0Ch
0Dh
0Eh
0Fh
10h
11h
12h
13h
14h
B3
Dig Controller Denominator z-3
Coefficient
Figure 25. Output Configuration Window
C0L
C0H
C1L
C1H
C2L
C2H
C3L
C3H
Dig Controller Numerator z0
Coefficient, Low Byte
Dig Controller Numerator z0
Coefficient, High Byte
Dig Controller Numerator z-1
Coefficient, Low Byte
Dig Controller Numerator z-1
Coefficient, High Byte
Dig Controller Numerator z-2
Coefficient, Low Byte
Dig Controller Numerator z-2
Coefficient, High Byte
Dig Controller Numerator z-3
Coefficient, High Byte
Dig Controller Numerator z-3
Coefficient, Low Byte
Output Voltage Monitoring
Output Current Monitoring
Temperature Monitoring
R/W-0
VOS7
Bit 7
R/W-0
VOS6
R/W-0
VOS5
R/W-0
VOS4
R/W-0
VOS3
R/W-0
VOS2
R/W-0
VOS1
R/W-0
VOS0
Bit 0
Bit 7:0 VOS[7:0], Output voltage setting
00h: corresponds to 0.5000V
01h: corresponds to 0.5125V
…
R
W
U
= Readable bit
= Writable bit
= Unimplemented bit,
read as ‘0’
77h: corresponds to 1.9875V
78h: corresponds to 2.0000V
79h: corresponds to 2.025V
…
- n = Value at POR reset
F9h: corresponds to 5.225V
FAh: corresponds to 5.250V
FBh: corresponds to 5.300V
…
FFh: corresponds to 5.500V
Figure 26. Output Voltage Setpoint Register VOS
VOM
IOM
TMP
17h
18h
19h
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 17 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
VOUT
8.1.1
Output Voltage Setpoint
Upper Regulation
The output voltage programming range is from 0.5V
to 5.5V. Within this range, there are 256 predefined
voltage set points. To improve resolution of the
output voltage settings, the voltage range is divided
into three sub-ranges as shown in Table 2.
Limit
Operating
Point
VI Curve Without
Load Regulation
VI Curve With
Load Regulation
Headroom without
Load Regulation
Headroom with
Lower Regulation
Limit
Table 2. Output Voltage Adjustment Resolution
Load Regulation
Heavy
Load
Light
Load
VOUT MIN, V
0.500
VOUT MAX, V
2.000
5.25
Resolution, mV
IOUT
12.5
25
Figure 27. Optimal Voltage Positioning Concept
2.025
Increased headroom allows tolerating larger voltage
deviations. For example, the step load change from
light to heavy load will cause the output voltage to
drop. If the optimal voltage positioning is utilized, the
output voltage will stay within the regulation window.
Otherwise, the output voltage will drop below the
lower regulation limit. To compensate for the voltage
drop external output capacitance will need to be
added, thus increasing cost and complexity of the
system.
5.3
5.5
50
8.1.2
Output Voltage Margining
If the output voltage needs to be varied by a certain
percentage, the margining function can be utilized.
The margining can be programmed in the POL
Configuration window or directly via the I2C bus
using high level commands as described in the
”ZM7300 Digital Power Manager Programming
Manual”.
The effect of optimal voltage positioning is shown in
Figure 28 and Figure 29. In this case, switching
output load causes large peak-to-peak deviation of
the output voltage. By programming load regulation,
the peak to peak deviation is dramatically reduced.
In order to properly margin POLs that are connected
in parallel, the POLs must be members of one of the
Parallel Buses. Refer to the DPM Configure Devices
window shown in Figure 53.
8.1.3
Optimal Voltage Positioning
Optimal voltage positioning increases the voltage
regulation window by properly positioning the output
voltage setpoint. Positioning is determined by the
load regulation that can be programmed in the POL
Configure Output window shown in Figure 25 or
directly via the I2C bus by writing into the CLS
register shown in Figure 36.
Figure 27 illustrates optimal voltage positioning
concept. If no load regulation is programmed, the
headroom (voltage differential between the output
voltage setpoint and
a
regulation limit) is
approximately half of the voltage regulation window.
When load regulation is programmed, the output
voltage will decrease as the output current
increases, so the VI characteristic will have a
negative slope. Therefore, by properly selecting the
operating point, it is possible to increase the
headroom as shown in the picture.
Figure 28. Transient Response without Optimal Voltage
Positioning
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 18 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
R/W-0
DON7
Bit 7
R/W-0
DON6
R/W-0
DON5
R/W-0
DON4
R/W-0
DON3
R/W-0
DON2
R/W-0
DON1
R/W-0
DON0
Bit 0
Bit 7:0 DON[7:0]: Turn-on delay time
00h: corresponds to 0ms delay after turn-on command has occurred
…
FFh: corresponds to 255ms delay after turn-on command has occurred
Figure 31. Turn-On Delay Register DON
8.2.2
Turn-Off Delay
U
U
R/W-0
DOF5
R/W-0
DOF4
R/W-0
DOF3
R/W-0
DOF2
R/W-0
DOF1
R/W-0
DOF0
Bit 0
---
---
Bit 7
Bit 7:6 Unimplemented, read as ‘0’
Bit 5:0 DOF[5:0]: Turn-off delay time
Figure 29. Transient Response with Optimal Voltage
Positioning
00h: corresponds to 0ms delay after turn-off command has occurred
…
3Fh: corresponds to 63ms delay after turn-off command has occurred
Figure 32. Turn-Off Delay Register DOF
8.2 Sequencing and Tracking
Turn-on delay, turn-off delay, and rising and falling
output voltage slew rates can be programmed in the
POL Configure Sequencing window shown in Figure
30 or directly via the I2C bus by writing into the DON,
DOF, and TC registers, respectively. The registers
are shown in Figure 31, Figure 32, and Figure 34.
Turn-off delay is defined as an interval from the
application of the Turn-Off command until the output
voltage reaches zero (if the falling slew rate is
programmed) or until both high side and low side
switches are turned off (if the slew rate is not
programmed). Therefore, for the slew rate controlled
turn-off the ramp-down time is included in the turn-off
delay as shown in Figure 33.
User programmed turn-off delay, TDF
Turn-Off
Command
Calculated
Ramp-down time, TF
delay TD
Internal
ramp-down
command
Falling slew
rate dVF/dT
VOUT
Time
Figure 33. Relationship between Turn-Off Delay and Falling
Slew Rate
Figure 30. POL Configure Sequencing Window
As it can be seen from the figure, the internally
calculated delay TD is determined by the equation
below.
8.2.1
Turn-On Delay
Turn-on delay is defined as an interval from the
application of the Turn-On command until the output
voltage starts ramping up.
VOUT
TD = TDF
−
,
dVF
dT
For proper operation TD shall be greater than zero.
The appropriate value of the turn-off delay needs to
be programmed to satisfy the condition.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 19 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
If the falling slew rate control is not utilized, the turn-
off delay only determines an interval from the
application of the Turn-Off command until both high
side and low side switches are turned off. In this
case, the output voltage ramp-down process is
determined by load parameters.
U
---
R/W-0
R2
R/W-0
R1
R/W-0
R0
R/W-1
SC
R/W-0
F2
R/W-0
F1
R/W-0
F0
Bit 7
Bit 0
Bit 7
Unimplemented , read as ‘0’
R[2:0]
R
W
U
= Readable bit
= Writable bit
= Unimplemented bit,
read as ‘0’
Bit 6:4
: Value of Vo rising slope
0: corresponds to 0.1V/ms (default)
1: corresponds to 0.2V/ms
2: corresponds to 0.5V/ms
3: corresponds to 1.0V/ms
4: corresponds to 2.0V/ms
5: corresponds to 5.0V/ms
6: corresponds to 8.3V/ms
7: corresponds to 8.3V/ms
- n = Value at POR reset
8.2.3
Rising and Falling Slew Rates
The output voltage tracking is accomplished by
programming the rising and falling slew rates of the
output voltage. To achieve programmed slew rates,
the output voltage is being changed in 12.5mV steps
where duration of each step determines the slew
rate. For example, ramping up a 1.0V output with a
slew rate of 0.5V/ms will require 80 steps duration of
25μs each.
SC
Bit 3
, Slew rate control at turn-off
0: Slew rate control is disabled
1: Slew rate control is enabled
F[2:0]
Bit 2:0
: Value of Vo falling slope
0: corresponds to -0.1V/ms (default)
1: corresponds to -0.2V/ms
2: corresponds to -0.5V/ms
3: corresponds to -1.0V/ms
4: corresponds to -2.0V/ms
5: corresponds to -5.0V/ms
6: corresponds to –8.3V/ms
7: corresponds to –8.3V/ms
Duration of each voltage step is calculated by
dividing the master clock frequency generated by the
DPM. Since all POLs in the system are synchronized
to the master clock, the matching of voltage slew
rates of different outputs is very accurate as it can be
seen in Figure 8 and Figure 12.
Figure 34. Tracking Configuration Register TC
8.3 Fault and Error Protection
ZY7007 Series converters have a comprehensive set
of programmable fault and error protection
provisions. The set includes the output over- and
undervoltage protection, overcurrent protection,
overtemperature protection, tracking protection,
overtemperature warning, and Power Good signal.
Status of protection logic is stored in the ST register
shown in Figure 35.
During the turn on process, a POL not only delivers
current required by the load (ILOAD), but also charges
the load capacitance. The charging current can be
determined from the equation below:
dVR
ICHG = CLOAD
×
dt
Where, CLOAD is load capacitance, dVR/dt is rising
voltage slew rate, and ICHG is charging current.
R-1
OC
R-1
TP
R-0
PG
R-1
TR
R-1
OT
R-1
UV
R-1
OV
R-1
PV
Bit 7
Bit 0
When selecting the rising slew rate, a user needs to
ensure that
TP
Bit 7
: Temperature Warning
R
W
U
= Readable bit
= Writable bit
PG
TR
OT
OC
UV
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Note:
: Power Good Warning
: Tracking Fault
= Unimplemented bit,
read as ‘0’
- n = Value at POR reset
ILOAD + ICHG < IOCP
: Overtemperature Fault
: Overcurrent Fault
Where IOCP is the overcurrent protection threshold of
the ZY7007. If the condition is not met, then the
overcurrent protection will be triggered during the
turn-on process. To avoid this, dVR/dt and the
overcurrent protection threshold should be
programmed to meet the condition above.
: Undervoltage Fault
OV: Overvoltage Error
PV
: Phase Voltage Error
- An activated warning/fault/error is encoded as ‘0’
Figure 35. Protection Status Register ST
Thresholds of overcurrent, over- and undervoltage
protection responses, and Power Good limits can be
programmed in the POL Configure Output window or
directly via the I2C bus by writing into the CLS and
PC2 registers shown in Figure 36 and Figure 37.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 20 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
R/W-0
LR2
R/W-0
LR1
R/W-0
LR0
R/W-1
TCE
R/W-1
CLS3
R/W-0
CLS2
R/W-1
CLS1
R/W-1
CLS0
Bit 0
Bit 7
Bit 7:5 LR[2:0], Load regulation configuration
000: 0 V/A/Ohm
R
W
U
= Readable bit
= Writable bit
= Unimplemented bit,
read as ‘0’
001: 0.39 V/A/Ohm
010: 0.78 V/A/Ohm
011: 1.18 V/A/Ohm
100: 1.57 V/A/Ohm
- n = Value at POR reset
101: 1.96 V/A/Ohm
110: 2.35 V/A/Ohm
111: 2.75 V/A/Ohm
Bit 4
TCE, Temperature compensation enable
0: disabled
1: enabled
Bit 3:0 CLS[3:0], Current limit setting
0h: corresponds to 37%
1h: corresponds to 47%
…
Bh: corresponds to 140%
Values higher than Bh are translated to Bh (140%)
Figure 38. POL Configure Fault Window
Figure 36. Current Limit Setpoint Register CLS
R/W-0
TRE
R/W-1
PVE
R/W-0
TRP
R/W-0
OTP
R/W-0
OCP
R/W-0
UVP
R/W-1
OVP
R/W-1
PVP
U
---
U
U
R/W-0
PGLL
R/W-1
R/W-0
R/W-0
R/W-0
Bit 7
Bit 0
---
---
OVPL1 OVPL0 UVPL1 UVPL0
Bit 0
Bit 7
TRE: Tracking fault enable
1 = enabled
0 = disabled
Bit 7
R
W
U
= Readable bit
= Writable bit
= Unimplemented bit,
read as ‘0’
- n = Value at POR reset
Bit 7:5 Unimplemented, read as ‘0’
Bit 4
R
W
U
= Readable bit
= Writable bit
= Unimplemented bit,
read as ‘0’
PVE
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
: Phase voltage error enable
PGLL: Set Power Good Low Level
1 = 95% of Vo
1 = enabled
0 = disabled
0 = 90% of Vo (Default)
TRP
: Tracking fault protection
- n = Value at POR reset
Bit 3:2 OVPL[1:0]: Set Over Voltage Protection
Level
1 = latching
0 = non latching
00 = 110% of Vo
01 = 120% of Vo
10 = 130% of Vo (Default)
11 = 130% of Vo
OTP
: Overtemperature protection configuration
1 = latching
0 = non latching
Bit 1:0 UVPL[1:0]: Set Under Voltage Protection Level
00 = 75% of Vo (Default)
OCP
: Overcurrent protection configuration
1 = latching
0 = non latching
01 = 80% of Vo
10 = 85% of Vo
UVP
: Undervoltage protection configuration
1 = latching
0 = non latching
Figure 37. Protection Configuration Register PC2
OVP
: Overvoltage protection configuration
1 = latching
0 = non latching
Note that the overvoltage and undervoltage
protection thresholds and Power Good limits are
defined as percentages of the output voltage.
Therefore, the absolute levels of the thresholds
change when the output voltage setpoint is changed
either by output voltage adjustment or by margining.
PVP
: Phase Voltage Protection
1 = latching
0 = non latching
Figure 39. Protection Configuration Register PC1
If the non-latching protection is selected, a POL will
attempt to restart every 130ms until the condition
that triggered the protection is removed. When
restarting, the output voltages follow tracking and
sequencing settings.
In addition, a user can change protection between
latching and non-latching, or disable certain
protection responses entirely. These settings are
programmed in the POL Configure Fault window
shown in Figure 38 or directly via the I2C by writing
into the PC1 register shown in Figure 39.
If the latching type is selected, a POL will turn off and
stay off. The POL can be turned on after 130ms, if
the condition that caused the fault is removed and
the respective bit in the ST register was cleared, or
the Turn On command was recycled, or the input
voltage was recycled.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 21 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
All protection functions can be classified into three
groups based on their effect on system operation:
warnings, faults, and errors.
8.3.2
Faults
This group includes overcurrent, overtemperature,
undervoltage, and tracking protection settings.
Triggering any protection in this group will turn off the
POL.
8.3.1
Warnings
This group includes Overtemperature Warning and
Power Good Signal. The warnings do not turn off
POLs but rather generate signals that can be
transmitted to a host controller via the I2C bus.
8.3.2.1
Overcurrent Protection
Overcurrent protection is active whenever the output
voltage of the POL exceeds the prebias voltage (if
any). When the output current reaches the OC
threshold, the output voltage will start decreasing. As
soon as the output voltage decreases below the
undervoltage protection threshold, the OC fault
signal is generated, the POL turns off and the OC bit
in the register ST is changed to 0. Both high side and
low side switches of the POL are turned off instantly
(fast turn-off).
8.3.1.1
Overtemperature Warning
The Overtemperature Warning is generated when
temperature of the controller exceeds 120°C. The
Overtemperature Warning changes the PT bit of the
status register ST to 0 and sends the signal to the
DPM. Reporting is enabled in the DPM Configuration
Fault management window or directly via the I2C by
writing into the PC3 register shown in Figure 41.
When the temperature falls below 117°C, the PT bit
is cleared and the Overtemperature Warning is
removed.
The temperature compensation is added to keep the
OC
temperatures above room temperature. Note that the
temperature compensation can be disabled in the
POL Configure Output window or directly via the I2C
by writing into the CLS register. However, it is
threshold
approximately
constant
at
8.3.1.2
Power Good
recommended
compensation enabled.
to
keep
the
temperature
Power Good is an open collector output that is pulled
low, if the output voltage is outside of the Power
Good window. The window is formed by the Power
Good High threshold that is equal to 110% of the
output voltage and the Power Good Low threshold
that can be programmed at 90 or 95% of the output
voltage.
8.3.2.2
Undervoltage Protection
The undervoltage protection is only active during
steady state operation of the POL to prevent
nuisance tripping. If the output voltage decreases
below the UV threshold and there is no OC fault, the
UV fault signal is generated, the POL turns off, and
the UV bit in the register ST is changed to 0. The
output voltage is ramped down according to
sequencing and tracking settings (regular turn-off).
The Power Good protection is only enabled after the
output voltage reaches its steady state level. The PG
pin is pulled low during transitions of the output
voltage from one level to other as shown in Figure
40.
The Power Good Warning pulls the Power Good pin
low and changes the PG bit of the status register ST
to 0. It sends the signal to the DPM, if the reporting is
enabled. When the output voltage returns within the
Power Good window, the PG pin is pulled high, the
PG bit is cleared and the Power Good Warning is
removed. The Power Good pin can also be pulled
low by an external circuit to initiate the Power Good
Warning.
8.3.2.3
Overtemperature Protection
Overtemperature protection is active whenever the
POL is powered up. If temperature of the controller
exceeds 130°C, the OT fault is generated, POL turns
off, and the OT bit in the register ST is changed to 0.
The output voltage is ramped down according to
sequencing and tracking settings (regular turn-off).
If non-latching OTP is programmed, the POL will
restart as soon as the temperature of the controller
decreases below the Overtemperature Warning
threshold of 120°C.
Note: To retrieve status information, Status Monitoring in the GUI
DPM Configure Devices window should be enabled (refer to
Digital Power Manager Data Sheet). The DPM will retrieve
the status information from each POL on a continuous
basis.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 22 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
8.3.2.4
Tracking Protection
value of the difference exceeds 250mV, the tracking
fault signal is generated, the POL turns off, and the
TR bit in the register ST is changed to 0. Both high
side and low side switches of the POL are turned off
instantly (fast turn-off).
Tracking protection is active only when the output
voltage is ramping up. The purpose of the protection
is to ensure that the voltage differential between
multiple rails being tracked does not exceed 250mV.
This protection eliminates the need for external
clamping diodes between different voltage rails
which are frequently recommended by ASIC
manufacturers.
The tracking protection can be disabled, if it
contradicts requirements of a particular system (for
example turning into high capacitive load where
rising slew rate is not important). It can be disabled
in the POL Configure Fault window or directly via the
I2C bus by writing into the PC1 register.
When the tracking protection is enabled, the POL
continuously compares actual value of the output
voltage to its programmed value as defined by the
output voltage and its rising slew rate. If absolute
Vo
1
Enable command
OTP
0
continuously enabled
1
0
OCP enabled
1
0
Power Good
Signal
OVP Threshold
OVP Threshold
PG High=110%VOUT
PG High=110%VOUT
OVP Threshold
Output Voltage
Output Voltage
PG High=110%VOUT
Output Voltage
PG Low Threshold
UVP Threshold
PG Low Threshold
UVP Threshold
PG Low Threshold
1.0V
prebiased output
UVP Threshold
Tracking
Thresholds
Time
Figure 40. Protection Enable Conditions
8.3.3
Errors
The OV threshold can be programmed from 110% to
130% of the output voltage setpoint, but not lower
than 1.0V.
The group includes overvoltage protection and the
phase voltage error. The phase voltage error is not
available in ZY7007.
8.3.4
Faults and Errors Propagation
8.3.3.1
Overvoltage Protection
The feature adds flexibility to the fault management
scheme by giving users control over propagation of
fault signals within and outside of the system. The
propagation means that a fault in one POL can be
programmed to turn off other POLs and devices in
the system, even if they are not directly affected by
the fault.
The overvoltage protection is active whenever the
output voltage of the POL exceeds the pre-bias
voltage (if any). If the output voltage exceeds the
overvoltage protection threshold, the overvoltage
error signal is generated, the POL turns off, and the
OV bit in the register ST is changed to 0. The high
side switch is turned off instantly, and simultaneously
the low side switch is turned on to ensure reliable
protection of sensitive loads. The low side switch
provides low impedance path to quickly dissipate
energy stored in the output filter and achieve
effective voltage limitation.
8.3.4.1
Grouping of POLs
Z-Series POLs can be arranged in several groups to
simplify fault management. A group of POLs is
defined as a number of POLs with interconnected
OK pins. A group can include from 1 to 32 POLs. If
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 23 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
fault propagation within a group is desired, the
propagation bit needs to be checked in the DPM
Configure Faults window. The parameters can also
be programmed directly via the I2C bus by writing
into the PC3 register shown in Figure 41.
When propagation is enabled, the faulty POL pulls its
OK pin low. A low OK line initiates turn-off of other
POLs in the group.
R/W-0
PTM
Bit 7
R/W-0
PGM
R/W-1
TRP
R/W-1
OTP
R/W-1
OCP
R/W-1
UVP
R/W-1
OVP
R/W-1
PVP
Bit 0
PTM
1 = enabled
0 = disabled
Bit 7
: Temperature warning Message
R
W
U
= Readable bit
= Writable bit
= Unimplemented bit,
read as ‘0’
Figure 42. DPM Configure Faults Window
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
PGM: Power good message
1 = enabled
0 = disabled
- n = Value at POR reset
In this case low OK line will signal DPM to pull other
OK lines low to initiate shutdown of other POLs as
programmed in the Group Fault Propagation window.
If an error is propagated, the DPM can also generate
commands to turn off a front end (a DC-DC
converter generating the intermediate bus voltage)
and trigger an optional crowbar protection to
accelerate removal of the IBV voltage.
TRP
: Tracking fault propagation
1 = enabled
0 = disabled
OTP
1 = enabled
0 = disabled
: Overtemperature fault propagation
OCP
1 = enabled
0 = disabled
: Overcurrent fault propagation
UVP
1 = enabled
0 = disabled
: Undervoltage fault propagation
8.3.4.2
Propagation Process
Propagation of a fault (OCP, UVP, OTP, and TRP)
initiates regular turn-off of other POLs. The faulty
POL in this case performs either the regular or the
fast turn-off depending on a specific fault as
described in section 8.3.2.
OVP
1 = enabled
0 = disabled
: Overvoltage error propagation
PVP: Phase voltage error propagation
1 = enabled
0 = disabled
Figure 41. Protection Configuration Register PC3
Propagation of an error initiates fast turn-off of other
POLs. The faulty POL performs the fast turn-off and
turns on its low side switch.
In addition, the OK lines can be connected to the
DPM to facilitate propagation of faults and errors
between groups. One DPM can control up to 4
independent groups. To enable fault propagation
between groups, the respective bit needs to be
checked in the DPM Configure Faults window, Group
Fault Propagation sub window shown in Figure 42.
Example of the fault propagation is shown in Figure
43 - Figure 44. In this three-output system (refer to
the block diagram in Figure 23), the POL powering
the output V3 (Ch 1 in the picture) encounters the
undervoltage fault after the turn-on. When the fault
propagation is not enabled, the POL turns off and
generates the UV fault signal. Because the UV fault
triggers the regular turn off, the POL meets its turn-
off delay and falling slew rate settings during the
turn-ff process as shown in Figure 43. Since the UV
fault is programmed to be non-latching, the POL will
attempt to restart every 130ms, repeating the
process described above until the condition causing
the undervoltage is removed.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 24 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
If the fault propagation between groups is enabled,
the POL powering the output V3 pulls its OK line low
and the DPM propagates the signal to the POL
powering the output V1 that belongs to other group.
The POL powering the output V1 (Ch3 in the picture)
executes the regular turn-off. Since both V1 and V3
have the same delay and slew rate settings they will
continue to turn off and on synchronously every
130ms as shown in Figure 44 until the condition
causing the undervoltage is removed. The POL
powering the output V2 continues to ramp up until it
reaches its steady state level.
130ms is the interval from the instant of time when
the output voltage ramps down to zero until the
output voltage starts to ramp up again. Therefore,
the 130ms hiccup interval is guaranteed regardless
of the turn-off delay setting.
Figure 44. Turn-On into UVP on V3. The UV Fault Is
Programmed To Be Non-Latching and Propagate
From Group C to Group A. Ch1 – V3 (Group C),
Ch2 – V2, Ch3 – V1 (Group A)
Summary of protection support, their parameters and
features are shown in Table 3
Figure 43. Turn-On into UVP on V3. The UV Fault Is
Programmed To Be Non-Latching. Ch1 – V3 (Group
C), Ch2 – V2, Ch3 – V1 (Group A)
Table 3. Summary of Protection Parameters and Features
Code
Name
Type
When Active
Turn
Low Side
Propagation
Disable
Off
Switch
PT
Pretemperature
Warning
Warning
Whenever VIN is applied
No
N/A
Readable by
DPM
No
PG
TR
OT
OC
UV
OV
Power Good
Tracking
Overtemperature
Overcurrent
Undervoltage
Overvoltage
Warning
Fault
Fault
Fault
Fault
During steady state
During ramp up
Whenever VIN is applied
When VOUT exceeds prebias
During steady state
No
Fast
Regular
Fast
Regular
Fast
N/A
Off
Off
Off
Off
On
Readable DPM
Regular turn off
Regular turn off
Regular turn off
Regular turn off
Fast turn off
No
Yes
No
No
No
No
Error
When VOUT exceeds prebias
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 25 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
8.4 PWM Parameters
R/W-0
FRQ2
Bit 7
R/W-0
FRQ1
R/W-0
FRQ0
R/W-01) R/W-01) R/W-01) R/W-01) R/W-01)
INT4
INT3
INT2
INT1
INT0
Bit 0
Z-Series POLs utilize the digital PWM controller. The
controller enables users to program most of the
PWM performance parameters, such as switching
frequency, interleave, duty cycle, and feedback loop
compensation.
Bit 7:5 FRQ[2:0]: PWM Frequency Selection
000: 500kHz
R
W
U
= Readable bit
= Writable bit
= Unimplemented bit,
read as ‘0’
001: 750kHz
010: 1000lHz
011: 1250kHz
100: 1250kHz
- n = Value at POR reset
101: 1500kHz
110: 1750kHz
111: 2000kHz
8.4.1
Switching Frequency
The switching frequency can be programmed in the
POL Controller Configure Compensation window
shown in Figure 45 or directly via the I2C bus by
writing into the INT register shown in Figure 46. Note
that the content of the register can be changed only
when the POL is turned off.
INT[4:0]
Bit 4:0
: Interleave position
00h: Ton starts with 0.0° Phase lag to SD Line
01h: Ton starts wi th 11.25° Phase lag to SD Line
02h: Ton starts with 22.50° Phase lag to SD Line
…
1Fh: Ton starts with 348.75° Phase lag to SD Line
1) Initial value depends on the state of the Interleave Mode (
IM=Open: At POR reset the 5 corresponding ADDRESS bits are loaded
IM=Low: At POR reset a 0 is loaded
) Input:
IM
Switching for all POLs connected to the SD line are
synchronized to the master clock generated by the
DPM. Each POL is equipped with a PLL and a
frequency divider so they can operate at multiples
(including fractional) of the master clock frequency
as programmed by a user. The converters can
operate at 500 kHz, 750 kHz, and 1 MHz. Although
synchronized, switching frequencies of different
POLs are independent of each other. It is
permissible to mix POLs operating at different
frequencies in one system. This allows optimizing
efficiency and transient response of each POL in the
system individually. (Note: POLs assigned to the
same power output bus are forced to use the same
switching frequency)
Figure 46. Interleave Configuration Register INT
8.4.2
Interleave
Interleave is defined as a phase delay between the
synchronizing slope of the master clock on the SD
pin and PWM signal of a POL. The interleave can be
programmed in the POL Controller Configure
Compensation window or directly via the I2C bus by
writing into the INT register.
Every POL generates switching noise. If no
interleave is programmed, all POLs in the system
switch simultaneously and noise reflected to the
input source from all POLs is added together as
shown in Figure 47.
Figure 45. PWM Controller Window
Figure 47. Input Voltage Noise, No Interleave
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 26 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
Figure 48 shows the input voltage noise of the three-
output system with programmed interleave. Instead
of all three POLs switching at the same time as in
the previous example, the POLs V1, V2, and V3
switch at 67.5°, 180°, and 303.75°, respectively.
Noise is spread evenly across the switching cycle
resulting in more than 1.5 times reduction. To
achieve similar noise reduction without the interleave
will require the addition of an external LC filter.
Figure 50. Output Voltage Noise, Full Load, 180° Interleave
The ZY7007 interleave feature is similar to that of
multiphase converters, however, unlike in the case of
multiphase converters, interleave does not have to
be equal to 360/N, where N is the number of POLs in
a system. ZY7007 interleave is independent of the
number of POLs in
a
system and is fully
programmable in 11.25° steps. It allows maximum
output noise reduction by intelligently spreading
switching energy.
Figure 48. Input Voltage Noise with Interleave
Note: Due to noise sensitivity issues that may occur in limited
cases, it is recommended to avoid phase lag settings of
112.5 and 123.75 degrees, otherwise false PG and/or OV
indications may occur. The GUI prohibits such settings.
Similar noise reduction can be achieved on the
output of POLs connected in parallel. Figure 49 and
Figure 50 show the output noise of two ZY7007s
connected in parallel without and with 180°
interleave, respectively. Resulting noise reduction is
more than 2 times and is equivalent to doubling
switching frequency or adding extra capacitance on
the output of the POLs.
8.4.3
Duty Cycle Limit
The ZY7007 is a step-down converter therefore VOUT
is always less than VIN. The relationship between the
two parameters is characterized by the duty cycle
and can be estimated from the following equation:
VOUT
DC =
,
VIN.MIN
Where, DC is the duty cycle, VOUT is the required
maximum output voltage (including margining),
VIN.MIN is the minimum input voltage.
It is good practice to limit the maximum duty cycle of
the controller's PWM to a somewhat higher value
compared to the steady-state duty cycle as
expressed by the above equation. This will further
protect the output from excessive voltages. The duty
cycle limit can be programmed in the POL Controller
Configure Compensation window or directly via the
Figure 49. Output Voltage Noise, Full Load, No Interleave
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 27 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
I2C bus by writing into the DCL register shown in
Figure 51.
8.4.5
Feedback Loop Compensation
Feedback loop compensation can be programmed in
the POL Controller Configure Compensation window
by setting frequency of poles and zeros of the
transfer function.
R/W-1
DCL5
Bit 7
R/W-1
DCL4
R/W-1
DCL3
R/W-0
DCL2
R/W-1
DCL1
R/W-0
DCL0
R/W-0
HI
R/W-0
LO
Bit 0
The transfer function of the POL converter is shown
in Figure 52. It is a third order function with two zeros
and three poles. Pole 1 is the integrator pole, Pole 2
is used in conjunction with Zero 1 and Zero 2 to
adjust the phase lead and limit the gain increase in
mid band. Pole 3 is used as a high frequency low-
pass filter to limit PWM noise.
R
W
U
= Readable bit
= Writable bit
= Unimplemented bit,
read as ‘0’
Bit 7:2 DCL[5:0], Duty Cycle Limitation
00h: 0
01h: 1/64
…
- n = Value at POR reset
3Fh: 63/64
Bit 1: HI, ADC high saturation feed-forward
0: disabled
1: enabled
Bit 0: LO, ADC low saturation feed-forward
0: disabled
1: enabled
Magnitude[dB]
Figure 51. Duty Cycle Limit Register
50
40
30
20
10
Z1 P1 Z2 P2
P3
P1: Pole 1
P2: Pole 3
P3: Pole 3
Z1: Zero 1
Z2: Zero 2
8.4.4
ADC Saturation Feedforward
To speed up the PWM response in case of heavy
dynamic loads, the duty cycle can be forced either to
0 or the duty cycle limit depending on the polarity of
the transient. This function is equivalent to having
two comparators defining a window around the
output voltage setpoint. When an error signal is
inside the window, it will produce gradual duty cycle
change proportional to the error signal. If the error
signal goes outside the window (usually due to large
output current steps), the duty cycle will change to its
limit in one switching cycle. In most cases this will
significantly improve transient response of the
controller, reducing amount of required external
capacitance.
Freq
[kHz]
0.1
0.1
1
1
10
10
100
1000
1000
Phase
[°]
+45
Freq
[kHz]
0
-45
100
-90
-135
-180
Figure 52. Transfer Function of PWM
Under certain circumstances, usually when the
maximum duty cycle limit significantly exceeds its
nominal value, the ADC saturation can lead to the
overcompensation of the output error. The
phenomenon manifests itself as low frequency
oscillations on the output of the POL. It can usually
be reduced or eliminated by disabling the ADC
saturation or limiting the maximum duty cycle to 120-
140% of the calculated value. It is not recommended
to use ADC saturation for output voltages higher
than 2.0V.
Positions of poles and zeroes are determined by
coefficients of the digital filter. The filter is
characterized by four numerator coefficients (C0, C1,
C2, C3) and three denominator coefficients (B1, B2,
B3). The coefficients are automatically calculated
when desired frequency of poles and zeros is
entered in the GUI POL Controller Configuration
Compensation window. The coefficients are stored in
the C0H, C0L, C1H, C1L, C2H, C2L, C3H, C3L, B1,
B2, and B3 registers.
Note: The GUI automatically transforms zero and pole
frequencies into the digital filter coefficients. Using the GUI
to determine filter coefficients is strongly recommended .
The ADC saturation feedforward can be
programmed in the POL Configure Controller
Compensation window or directly via the I2C bus by
writing into the DCL register.
Programming feedback loop compensation allows
optimizing POL performance for various application
conditions. For example, increase in bandwidth can
significantly improve dynamic response.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 28 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
8.6 Performance Parameters Monitoring
The POL converters can monitor their own
performance parameters such as output voltage,
output current, and temperature.
8.5 Current Share
The POL converters are equipped with the digital
current share function. To activate the current share,
interconnect the CS pins of the POLs connected in
parallel. The digital signal transmitted over the CS
line sets output currents of all POLs to the same
level.
The output voltage is measured at the output sense
pins, output current is measured using the ESR of
the output inductor and temperature is measured by
the thermal sensor built into the controller IC. Output
current readings are adjusted based on temperature
readings to compensate for the change of ESR of
the inductor with temperature.
When POLs are connected in parallel, they must be
included in the same parallel bus in the DPM
Configure Devices window shown in Figure 53. In
this case, the GUI automatically copies parameters
of one POL onto all POLs connected to the parallel
bus. It makes it impossible to configure different
performance parameters for POLs connected in
parallel except for interleave and load regulation
settings that are independent. The interleave allows
to reduce and move the output noise of the
converters connected in parallel to higher
frequencies as shown in Figure 49 and Figure 50.
The load regulation allows controlling the current
share loop gain in case of small signal oscillations. It
is recommended to always add a small amount of
load regulation to one of the converters connected in
parallel to reduce loop gain and therefore improve
stability.
An 8-Bit Analog to Digital Converter (ADC) converts
the output voltage, output current, and temperature
into a digital signal to be transmitted via the serial
interface. The ADC allows a minimum sampling
frequency of 1 kHz for all three values.
Monitored parameters are stored in registers (VOM,
IOM, and TMON) that are continuously updated and
not double buffered. If the Group Monitoring
Retrieval enable bits for Parametric (P-Monitor) and
Status (S-Monitor) in the DPM Configure Devices
window shown in Figure 53 are checked, those
registers are copied into the ring buffer located in the
DPM. Contents of the ring buffer can be displayed in
the DPM Monitor Window shown in Figure 54 or it
2C bus using high and
can be read directly via the I
low level commands as described in the ”ZM7300
Digital Power Manager Programming Manual”.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 29 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
Figure 53 DPM Configure Devices Window
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 30 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
Figure 54. DPM Monitoring Window
EN60950, although specific applications may have
other or additional requirements.
9. Safety
The ZY7007 POL converters do not provide
isolation from input to output. The input devices
powering ZY7007 must provide relevant isolation
requirements according to all IEC60950 based
standards. Nevertheless, if the system using the
converter needs to receive safety agency approval,
certain rules must be followed in the design of the
system. In particular, all of the creepage and
clearance requirements of the end-use safety
requirements must be observed. These requirements
are included in UL60950 - CSA60950-00 and
The ZY7007 POL converters have no internal fuse. If
required, the external fuse needs to be provided to
protect the converter from catastrophic failure. Refer
to the “Input Fuse Selection for DC/DC converters”
application note on www.power-one.com for proper
selection of the input fuse. Both input traces and the
chassis ground trace (if applicable) must be capable
of conducting a current of 1.5 times the value of the
fuse without opening. The fuse must not be placed in
the grounded input line.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 31 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
Abnormal and component failure tests were
Voltage), according to all IEC60950 based
standards, the input to the POL needs to be supplied
by an isolated secondary source providing a SELV
also.
conducted with the POL input protected by a fast-
acting 65 V, 15 A, fuse. If a fuse rated greater than
15 A is used, additional testing may be required.
In order for the output of the ZY7007 POL converter
to be considered as SELV (Safety Extra Low
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 32 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
10. Mechanical Drawings
All Dimensions are in mm
Tolerances:
0.5-10
±0.1
10-100 ±0.2
Pin Coplanarity: 0.1 max
12.5 ±0.30
SMT PICKUP POINT
18
19
0.4
22.2 ±0.30
17.7
1
36
Pin 1
2.6
5.2
Figure 55. Top (Left) and Bottom Views
6.5
±0.30
2.1
8.7
12
Figure 56. Side View
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 33 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
12.80 (Ao)
Y
12.8
SMT PICKUP
POINT
X
X
Pin 1 indicating
Y
Section
Y , Y
Chamfer.
DIRECTION OF FEED
4
1.5
24
Section
X , X
Figure 57. Tape and Reel
22.20
2.00
19
36
0.60
(x 36)
12.50
Top View
10.40
1
18
Pin 1
1.00
2.60
Figure 58. Recommended PCB Pad Sizes
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com
Page 34 of 35
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input • 0.5V to 5.5V Output
Figure 59. Recommended PCB Layout for Multilayer PCBs
Notes:
1. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
2. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
I2C is a trademark of Philips Corporation.
ZD-00245 Rev. 2.8, 5-May-2011
www.power-one.com