ZY7115H-T3-G [BEL]

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-25;
ZY7115H-T3-G
型号: ZY7115H-T3-G
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-25

文件: 总33页 (文件大小:1170K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
Member of the  
Family  
Features  
RoHS lead free and lead-solder-exempt products are  
available  
Wide input voltage range: 3V13.2V  
High continuous output current: 15A  
Wide programmable output voltage range: 0.5V5.5V  
Active digital current share  
Single-wire serial communication bus for frequency  
synchronization, programming, and monitoring  
Optimal voltage positioning with programmable slope  
of the VI line  
Overcurrent, overvoltage, undervoltage, and  
overtemperature protections with programmable  
thresholds and types  
Applications  
Programmable fixed switching frequency 0.5-1.0MHz  
Programmable turn-on and turn-off delays  
Low voltage, high density systems with  
Intermediate Bus Architectures (IBA)  
Programmable turn-on and turn-off voltage slew rates  
with tracking protection  
Point-of-load regulators for high performance DSP,  
FPGA, ASIC, and microprocessor applications  
Programmable feedback loop compensation  
Power Good signal with programmable limits  
Programmable fault management  
Desktops, servers, and portable computing  
Broadband, networking, optical, and  
communications systems  
Active memory bus terminators  
Start up into the load pre-biased up to 100%  
Full rated current sink  
Benefits  
Real time voltage, current, and temperature  
measurements, monitoring, and reporting  
Integrates digital power conversion with intelligent  
power management  
Small footprint SMT package: 8x32mm  
Low profile of 14mm  
Eliminates the need for external power  
management components  
Compatible with conventional pick-and-place  
equipment  
Completely programmable via industry-standard  
I2C communication bus  
Wide operating temperature range  
One part that covers all applications  
UL 60950-1/CSA 22.2 No. 60950-1-07 Second  
Edition, IEC 60950-1: 2005, and EN 60950-1:2006  
Reduces board space, system cost and  
complexity, and time to market  
Description  
Power-One‟s point-of-load converters are recommended for use with regulated bus converters in an Intermediate  
Bus Architecture (IBA). The ZY7115 is an intelligent, fully programmable step-down point-of-load DC-DC module  
integrating digital power conversion and intelligent power management. When used with ZM7300 Series Digital  
Power Managers, the ZY7115 completely eliminates the need for external components for sequencing, tracking,  
protection, monitoring, and reporting. All parameters of the ZY7115 are programmable via the industry-standard  
I2C communication bus and can be changed by a user at any time during product development and service.  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 1 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
Reference Documents:  
ZM7300 Digital Power Manager Data Sheet  
ZM7300 Digital Power Manager Programming Manual  
Power-One I2C Graphical User Interface  
ZM00056-KIT USB to I2C Adapter Kit User Manual  
1. Ordering Information  
ZY  
71  
15  
x
y
zz  
Output voltage setpoint  
accuracy:  
L 1.2% or 20mV,  
whichever is greater.  
H1 1.0% or 10mV,  
whichever is greater  
RoHS compliance:  
No suffix - RoHS  
compliant with Pb  
solder exemption2  
G - RoHS compliant  
for all six substances  
Packaging Option3:  
T1 500pcs T&R  
T2 100pcs T&R  
T3 50pcs T&R  
Q1 1pc sample for  
evaluation only  
Product  
family:  
Z-One  
Series:  
Intelligent  
POL  
Output  
Current:  
15A  
Dash  
Module  
Converter  
______________________________________  
1
Contact factory for availability.  
2
The solder exemption refers to all the restricted materials except lead in solder. These materials are Cadmium (Cd), Hexavalent chromium  
(Cr6+), Mercury (Hg), Polybrominated biphenyls (PBB), Polybrominated diphenylethers (PBDE), and Lead (Pb) used anywhere except in  
solder.  
3
Packaging option is used only for ordering and not included in the part number printed on the POL converter label.  
4
The evaluation board is available in only one configuration: ZM7300-KIT-HKS.  
Example: ZY7115HG-T2: A 100-piece reel of RoHS compliant POL converters with the output voltage setpoint of  
1.0% or 10mV, whichever is greater. Each POL converter is labeled ZY7115HG.  
2. Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-  
term reliability, and cause permanent damage to the converter.  
Parameter  
Operating Temperature  
Input Voltage  
Conditions/Description  
Controller case temperature  
250ms Transient  
Min  
Max  
105  
15  
Units  
C  
-40  
VDC  
ADC  
Output Current  
(See Output Current Derating Curves)  
-15  
15  
3. Environmental and Mechanical Specifications  
Parameter  
Ambient Temperature Range  
Storage Temperature (Ts)  
Weight  
Conditions/Description  
Min  
Nom  
Max  
85  
Units  
-40  
-55  
C  
C  
125  
15  
grams  
MHrs  
MTBF  
Calculated Per Telcordia Technologies SR-332  
4.82  
ZY7115  
ZY7115G  
220  
260  
C  
C  
Peak Reflow Temperature  
245  
Lead Plating  
ZY7115 and ZY7115G  
ZY7115 and ZY7115G  
100% Matte Tin  
3
Moisture Sensitivity Level  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 2 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
4. Electrical Specifications  
Specifications apply at the input voltage from 3V to 13.2V, output load from 0 to 15A, ambient temperature from -40°C to 85°C,  
100F output capacitance, and default performance parameters settings unless otherwise noted.  
4.1 Input Specifications  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
VDC  
At VIN<4.75V, VLDO pin needs to be  
connected to an external voltage source  
higher than 4.75V  
Input voltage (VIN)  
3
13.2  
Input Current (at no load)  
50  
mADC  
VIN4.75V, VLDO pin connected to VIN  
Undervoltage Lockout (VLDO  
connected to VIN)  
Ramping Up  
Ramping Down  
4.2  
3.75  
VDC  
VDC  
Undervoltage Lockout (VLDO  
connected to VAUX=5V)  
Ramping Up  
Ramping Down  
3.0  
2.5  
VDC  
VDC  
External Low Voltage Supply  
VLDO Input Current  
Connect to VLDO pin when VIN<4.75V  
4.75  
13.2  
VDC  
Current drawn from the external low  
voltage supply at VLDO=5V  
50  
mADC  
4.2 Output Specifications  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Programmable1  
0.5  
5.5  
VDC  
VDC  
Output Voltage Range (VOUT  
)
Default (no programming)  
0.5  
VIN=12V, IOUT=0.5*IOUT MAX  
FSW=500kHz, room temperature  
,
Output Voltage Setpoint Accuracy  
(See Ordering Information)  
Output Current (IOUT  
Line Regulation  
)
VIN MIN to VIN MAX  
-152  
15  
ADC  
VIN MIN to VIN MAX  
0 to IOUT MAX  
±0.3  
±0.2  
%VOUT  
%VOUT  
Load Regulation  
Dynamic Regulation  
Peak Deviation  
Settling Time  
Slew rate 2.5A/s, 50 - 100% load step  
COUT=300F, FSW=1MHz  
mV  
s  
100  
50  
to 10% of peak deviation  
mV  
mV  
mV  
mV  
mV  
mV  
VIN=5.0V, VOUT=0.5V, FSW=500kHz  
VIN=13.2V, VOUT=0.5V, FSW=500kHz  
VIN=5.0V, VOUT=2.5V, FSW=500kHz  
VIN=13.2V, VOUT=2.5V, FSW=500kHz  
VIN=13.2V, VOUT=5.0V, FSW=500kHz  
10  
15  
10  
25  
35  
Output Voltage Peak-to-Peak  
Ripple and Noise  
BW=20MHz  
Full Load  
Temperature Coefficient  
Switching Frequency  
VIN=12V, IOUT=0.5*IOUT MAX  
20  
ppm/°C  
Default  
500  
kHz  
kHz  
%
%
Programmable, 250kHz steps  
Default  
Programmable, 1.56% steps  
500  
0
1,000  
95  
90.5  
Duty Cycle Limit  
1
ZY7115 is a step-down converter, thus the output voltage is always lower than the input voltage as show in Figure 1.  
At the negative output current (bus terminator mode) efficiency of the ZY7115 degrades resulting in increased internal power dissipation.  
2
Therefore maximum allowable negative current under specific conditions is 20% lower than the current determined from the derating curves  
shown in paragraph 5.5.  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 3 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
VOUT  
[V]  
5.5  
5.0  
4.5  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
Min Load 0.2A  
2.0  
4.0  
3.0 3.15  
6.0  
8.0  
10.0  
12.0  
14.0  
VIN [V]  
5.5  
13.2  
6.25  
Figure 1. Output Voltage as a Function of Input Voltage and Output Current  
4.3 Protection Specifications  
Parameter  
Conditions/Description  
Output Overcurrent Protection  
Min  
Nom  
Max  
Units  
Default  
Programmable  
Non-Latching, 130ms period  
Latching/Non-Latching  
Type  
Default  
Programmable in 11 steps  
170  
170  
%IOUT  
%IOUT  
Threshold  
60  
Threshold Accuracy  
-25  
25  
%IOCP.SET  
Output Overvoltage Protection  
Default  
Programmable  
Non-Latching, 130ms period  
Latching/Non-Latching  
Type  
Default  
Programmable in 10% steps  
130  
%VO.SET  
%VO.SET  
Threshold  
1101  
-2  
130  
2
Threshold Accuracy  
Measured at VO.SET=2.5V  
%VOVP.SET  
From instant when threshold is exceeded until  
the turn-off command is generated  
Delay  
6
μs  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 4 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
Output Undervoltage Protection  
Default  
Programmable  
Non-Latching, 130ms period  
Latching/Non-Latching  
Type  
Default  
Programmable in 5% steps  
75  
%VO.SET  
%VO.SET  
Threshold  
Threshold Accuracy  
Delay  
75  
-2  
85  
2
Measured at VO.SET=2.5V  
%VUVP.SET  
From instant when threshold is exceeded until  
the turn-off command is generated  
6
μs  
Overtemperature Protection  
Default  
Programmable  
Non-Latching, 130ms period  
Latching/Non-Latching  
Type  
Turn Off Threshold  
Turn On Threshold  
Threshold Accuracy  
Delay  
Temperature is increasing  
130  
120  
5
C  
C  
C  
μs  
Temperature is decreasing after the module was  
shut down by OTP  
-5  
From instant when threshold is exceeded until  
the turn-off command is generated  
6
Tracking Protection (when Enabled)  
Default  
Programmable  
Disabled  
Type  
Latching/Non-Latching, 130ms period  
Threshold  
Enabled during output voltage ramping up  
mVDC  
250  
Threshold Accuracy  
-50  
50  
mVDC  
From instant when threshold is exceeded until  
the turn-off command is generated  
Delay  
6
μs  
Overtemperature Warning  
Threshold  
Threshold Accuracy  
Hysteresis  
Always enabled, reported in Status register  
120  
C  
C  
C  
-5  
5
3
6
From instant when threshold is exceeded until  
the warning signal is generated  
Delay  
μs  
Power Good Signal (PGOOD pin)  
VOUT is inside the PG window  
VOUT is outside the PG window  
High  
Low  
Logic  
N/A  
Default  
Programmable in 5% steps  
90  
%VO.SET  
%VO.SET  
Lower Threshold  
Upper Threshold  
Delay  
90  
-2  
95  
2
110  
6
%VO.SET  
μs  
From instant when threshold is exceeded until  
status of PG signal changes  
Threshold Accuracy  
Measured at VO.SET=2.5V  
%VO.SET  
___________________  
1
Minimum OVP threshold is 1.0V  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 5 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
4.4 Feature Specifications  
Parameter  
Conditions/Description  
Current Share  
Min  
Nom  
Max  
Units  
Type  
Active, Single Line  
10  
Maximum Number of Modules  
Connected in Parallel  
IOUT MIN≥20%*IOUT NOM  
Maximum Number of Modules  
Connected in Parallel  
IOUT MIN=0  
4
Current Share Accuracy  
Interleave (Phase Shift)  
IOUT MIN≥20%*IOUT NOM  
±20  
%IOUT  
Interleave  
Default  
0
Degree  
degree  
0
348.75  
Programmable in 11.25steps  
Sequencing  
Default  
Programmable in 1ms steps  
Default  
Programmable in 1ms steps  
0
ms  
ms  
ms  
ms  
Turn ON Delay  
Turn OFF Delay  
0
0
255  
0
63  
Tracking  
Default  
Programmable in 7 steps  
Default  
Programmable in 7 steps  
0.1  
V/ms  
V/ms  
V/ms  
V/ms  
Turn ON Slew Rate  
Turn OFF Slew Rate  
0.1  
8.331  
-0.1  
-0.1  
-8.331  
Optimal Voltage Positioning  
Default  
Programmable in 7 steps  
0
mV/A  
mV/A  
Load Regulation  
0
6.27  
Feedback Loop Compensation  
Zero1 (Effects phase lead and  
increases gain in mid-band)  
Zero 2 (Effects phase lead and  
increases gain in mid-band)  
Pole 1 (Integrator Pole, effects  
loop gain)  
Pole 2 (Effects phase lag and  
limits gain in mid-band)  
Pole 3 (High frequency low- pass  
filter to limit PWM noise)  
Programmable  
0.05  
0.05  
0.05  
1
50  
50  
kHz  
kHz  
kHz  
kHz  
kHz  
Programmable  
Programmable  
Programmable  
50  
1000  
1000  
Programmable  
Monitoring  
1
-2%VOUT  
1 LSB  
2%VOUT  
+ 1 LSB  
Voltage Monitoring Accuracy  
Current Monitoring Accuracy  
1 LSB=22mV  
mV  
20%*IOUT NOM < IOUT < IOUT NOM  
-20  
-5  
+20  
+5  
%IOUT  
Temperature Monitoring Accuracy Junction temperature of POL controller  
C  
Remote Voltage Sense (+VS and VS pins)  
Between +VS and VOUT  
Voltage Drop Compensation  
Voltage Drop Compensation  
300  
100  
mV  
mV  
Between -VS and PGND  
___________________  
1
Achieving fast slew rates under specific line and load conditions may require feedback loop adjustment  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 6 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
4.5 Signal Specifications  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
VDD  
Internal supply voltage  
3.15  
3.3  
3.45  
V
SYNC/DATA Line (SD pin)  
ViL_sd  
ViH_sd  
LOW level input voltage  
HIGH level input voltage  
-0.5  
0.3 x VDD  
VDD + 0.5  
V
V
0.75 x  
VDD  
0.25 x  
VDD  
0.45 x  
VDD  
Vhyst_sd  
Hysteresis of input Schmitt trigger  
V
VoL  
Tr_sd  
LOW level sink current @ 0.5V  
Maximum allowed rise time 10/90%VDD  
Added node capacitance  
14  
60  
300  
10  
mA  
ns  
Cnode_sd  
Ipu_sd  
5
pF  
Pull-up current source at Vsd=0V  
Clock frequency of external SD line  
0.3  
1.0  
525  
mA  
kHz  
Freq_sd  
475  
% of clock  
cycle  
% of clock  
cycle  
Tsynq  
T0  
Sync pulse duration  
22  
72  
28  
78  
Data=0 pulse duration  
Inputs: ADDR0…ADDR4, EN, IM  
ViL_x  
ViH_x  
LOW level input voltage  
HIGH level input voltage  
-0.5  
0.3 x VDD  
VDD+0.5  
0.3 x VDD  
V
V
V
0.7 x VDD  
0.1 x VDD  
Vhyst_x  
Hysteresis of input Schmitt trigger  
External pull down resistance  
ADDRX forced low  
RdnL_ADDR  
10  
kOhm  
Power Good and OK Inputs/Outputs  
Iup_PG  
Iup_OK  
ViL_x  
Pull-up current source input forced low PG  
Pull-up current source input forced low OK  
LOW level input voltage  
25  
175  
110  
725  
μA  
μA  
V
-0.5  
0.3 x VDD  
VDD+0.5  
0.3 x VDD  
20  
ViH_x  
Vhyst_x  
IoL  
HIGH level input voltage  
0.7 x VDD  
0.1 x VDD  
4
V
Hysteresis of input Schmitt trigger  
LOW level sink current at 0.5V  
V
mA  
Current Share Bus (CS pin)  
Pull-up current source at VCS = 0V  
Iup_CS  
ViL_CS  
0.84  
-0.5  
3.1  
mA  
V
LOW level input voltage  
HIGH level input voltage  
0.3 x VDD  
0.75 x  
VDD  
ViH_CS  
VDD+0.5  
V
V
0.25 x  
VDD  
0.45 x  
VDD  
Vhyst_CS  
Hysteresis of input Schmitt trigger  
IoL  
LOW level sink current at 0.5V  
14  
60  
mA  
ns  
Tr_CS  
Maximum allowed rise time 10/90% VDD  
100  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 7 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
5. Typical Performance Characteristics  
95  
90  
85  
80  
75  
70  
65  
60  
5.1 Efficiency Curves  
95  
90  
85  
80  
75  
Vout=0.5V  
Vout=3.3V  
Vout=1.2V  
Vout=5.0V  
Vout=2.5V  
55  
50  
Vout=0.5V  
Vout=1.2V  
Vout=2.5V  
0
1.5  
3
4.5  
6
7.5  
9
10.5 12 13.5 15  
Output Current, A  
70  
0
1.5  
3
4.5  
6
7.5  
9
10.5 12 13.5 15  
Output Current, A  
Figure 4. Efficiency vs. Load. Vin=12V, Fsw=500kHz  
Figure 2. Efficiency vs. Load. Vin=3.3V, Fsw=500kHz  
95  
100  
90  
85  
80  
75  
70  
65  
95  
90  
85  
80  
75  
70  
Vin=3.3V  
Vin=5V  
Vin=12V  
4.5  
Vout=0.5V  
Vout=2.5V  
Vout=1.2V  
Vout=3.3V  
0.5  
1
1.5  
2
2.5  
3
3.5  
4
5
5.5  
Output Voltage, V  
0
1.5  
3
4.5  
6
7.5  
9
10.5 12 13.5 15  
Output Current, A  
Figure 5. Efficiency vs. Output Voltage, Iout=15A,  
Fsw=500kHz  
Figure 3. Efficiency vs. Load. Vin=5V, Fsw=500kHz  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 8 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
90  
88  
86  
84  
82  
80  
78  
95  
90  
85  
80  
75  
70  
65  
Vout=0.5V  
Vout=2.5V  
Vout=1.2V  
Vout=3.3V  
500kHz  
4.5  
750kHz  
9
1MHz  
76  
3
4
5
6
7
8
9
10  
11  
12  
0
1.5  
3
6
7.5  
10.5 12 13.5 15  
Input Voltage, V  
Output Current, A  
Figure 6. Efficiency vs. Input Voltage. Iout=15A, Fsw=500kHz  
Figure 8. Efficiency vs. Load. Vin=5V, Vout=1.2V  
95  
94  
93  
92  
91  
90  
89  
95  
93  
91  
89  
87  
85  
83  
500kHz  
750kHz  
1MHz  
500kHz  
4.5  
750kHz  
9
1MHz  
88  
0
1.5  
3
6
7.5  
10.5 12 13.5 15  
0
1.5  
3
4.5  
6
7.5  
9
10.5 12 13.5 15  
Output Current, A  
Output Current, A  
Figure 7. Efficiency vs. Load. Vin=3.3V, Vout=2.5V  
Figure 9. Efficiency vs. Load. Vin=12V, Vout=5V  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 9 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
94  
92  
90  
88  
86  
84  
82  
80  
3.3Vin/2.5Vout  
5Vin/1.2Vout  
750  
12Vin/5Vout  
1000  
500  
Switching Frequency, kHz  
Figure 12. Turn-On with Different Rising Slew Rates.  
Rising Slew Rates are Programmed as follows: V1-  
1V/ms, V2-0.5V/ms, V3-0.2V/ms.  
Figure 10. Efficiency vs. Switching Frequency. Iout=15A  
Vin=12V, Ch1 V1, Ch2 V2, Ch3 V3  
5.2 Turn-On Characteristics  
Figure 13. Sequenced Turn-On. Rising Slew Rate is  
Programmed at 1V/ms. V2 Delay is 2ms, V3 delay  
is 4ms. Vin=12V, Ch1 V1, Ch2 V2, Ch3 V3  
Figure 11. Tracking Turn-On. Rising Slew Rate is  
Programmed at 0.5V/ms.  
Vin=12V, Ch1 V1, Ch2 V2, Ch3 V3  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 10 of 33  
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
5.3 Turn-Off Characteristics  
Figure 14. Turn On with Sequencing and Tracking. Rising  
Slew Rate Programmed at 0.2V/ms, V1 and V3  
delays are programmed at 20ms.  
Vin=12V, Ch1 V1, Ch2 V2, Ch3 V3  
Figure 16. Tracking Turn-Off. Falling Slew Rate is  
Programmed at 0.5V/ms.  
Vin=12V, Ch1 V1, Ch2 V2, Ch3 V3  
Figure 15. Turn On into Prebiased Load. V3 is Prebiased by  
V2 via a Diode.  
Vin=12V, Ch1 V1, Ch2 V2, Ch3 V3  
Figure 17. Turn-Off with Tracking and Sequencing. Falling  
Slew Rate is Programmed at 0.5V/ms.  
Vin=12V, Ch1 V1, Ch2 V2, Ch3 V3  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 11 of 33  
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
5.4 Transient Response  
The pictures below show the deviation of the output  
voltage in response to the 50-100-50% step load at  
2.5A/μs. In all tests the POL converters were  
operating at 1MHz and had 6x47μF ceramic  
capacitors connected across the output pins.  
Bandwidth of the feedback loop was programmed for  
faster transient response.  
Figure 20. Vin=5V, Vout=1V. Bandwidth is 40kHz  
Figure 18. Vin=12V, Vout=1V. Bandwidth is 40kHz  
Figure 21. Vin=5V, Vout=2.5V. Bandwidth is 40kHz  
Figure 19. Vin=12V, Vout=5V. Bandwidth is 40kHz  
Figure 22. Vin=3V, Vout=1V. Bandwidth is 30kHz  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 12 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
5.5 Thermal Derating Curves  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
NC  
50  
100 LFM  
200 LFM  
400 LFM  
600 LFM  
80  
45  
55  
60  
65  
70  
75  
85  
Temperature, 'C  
Figure 23. Thermal Derating Curves. Vin=13.2V, Vout=2.5V, Fsw=500kHz  
15  
14  
13  
12  
11  
10  
9
8
7
6
0 LFM  
50  
100 LFM  
200 LFM  
400 LFM  
600 LFM  
80  
5
45  
55  
60  
65  
70  
75  
85  
Temperature, 'C  
Figure 24. Thermal Derating Curves. Vin=13.2V, Vout=5V, Fsw=500kHz  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 13 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
15  
14  
13  
12  
11  
10  
9
8
7
6
0 LFM  
50  
100 LFM  
200 LFM  
400 LFM  
600 LFM  
80  
5
45  
55  
60  
65  
70  
75  
85  
Temperature, 'C  
Figure 25. Thermal Derating Curves. Vin=13.2V, Vout=5V, Fsw=1,000kHz  
6. Typical Application  
Intermediate Voltage Bus  
SD  
I2C  
OK_C  
DPM  
OK_B  
OK_A  
CS  
ZY7115  
ZY7115  
ZY7115  
ZY7115  
ADDR  
ADDR  
ADDR  
ADDR  
V1  
V2  
V3  
Figure 26. Block Diagram of Typical Multiple Output Application with Digital Power Manager and I2C Interface  
The block diagram of a typical application of ZY7115 point-of-load converters (POL) is shown in Figure 26. The  
system includes multiple POLs and a ZM7300 series Digital Power Manager (DPM). All POLs are connected to the  
DPM and to each other via a single-wire SD (sync/data) line. The line provides synchronization of all POLs to the  
master clock generated by the DPM and simultaneously performs bidirectional data transfer between POLs and  
the DPM. Each POL has a unique 5-bit address programmed by grounding respective address pins. To enable the  
current share, CS pins of POLs connected in parallel are linked together.  
There are three groups of POLs in the application, groups A, B, and group C. A group is defined as a number of  
POLs interconnected via OK pins. Grouping of POLs enables users to program, control, and monitor multiple  
POLs simultaneously and execute advanced fault management schemes.  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 14 of 33  
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
The complete schematic of the application is shown in Figure 27.  
Figure 27. Complete Schematic of the Application Shown in Figure 26. Intermediate Bus Voltage is from 4.75V to 13.2V.  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 15 of 33  
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
7. Pin Assignments and Description  
Pin  
Name  
Pin  
Pin  
Buffer  
Type  
Pin Description  
Notes  
Number Type  
Connect to an external voltage source higher than  
4.75V, if VIN<4.75V. Connect to VIN, if VIN≥4.75V  
VLDO  
1
P
Low Voltage Dropout  
IM  
NC  
2
3
Not Used  
Not Used  
Leave floating  
Leave floating  
Leave floating  
Leave floating  
Leave floating  
Leave floating  
Leave floating  
Leave floating  
Connect to PGND  
NC  
4
Not Used  
NC  
5
Not Used  
NC  
6
Not Used  
NC  
7
Not Used  
NC  
8
Not Used  
VREF  
EN  
9
Not Used  
10  
Connect to PGND  
Connect to OK pin of other Z-POL and/or DPM.  
Leave floating, if not used  
OK  
11  
I/O  
PU  
Fault/Status Condition  
SD  
12  
13  
14  
I/O  
I/O  
PU  
PU  
Sync/Data Line  
Power Good  
Not Used  
Connect to SD pin of DPM  
PGOOD  
TRIM  
Leave floating  
Connect to CS pin of other Z-POLs connected in  
parallel  
CS  
15  
I/O  
PU  
Current Share  
ADDR4  
ADDR3  
ADDR2  
ADDR1  
ADDR0  
-VS  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
I
I
PU  
PU  
PU  
PU  
PU  
PU  
PU  
POL Address Bit 4  
POL Address Bit 3  
POL Address Bit 2  
POL Address Bit 1  
POL Address Bit 0  
Negative Voltage Sense  
Positive Voltage Sense  
Output Voltage  
Tie to PGND for 0 or leave floating for 1  
Tie to PGND for 0 or leave floating for 1  
Tie to PGND for 0 or leave floating for 1  
Tie to PGND for 0 or leave floating for 1  
Tie to PGND for 0 or leave floating for 1  
Connect to the negative point close to the load  
Connect to the positive point close to the load  
I
I
I
I
+VS  
I
VOUT  
PGND  
VIN  
P
P
P
Power Ground  
Input Voltage  
Legend: I=input, O=output, I/O=input/output, P=power, A=analog, PU=internal pull-up  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 16 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
ZY7115 converters can be programmed using the  
Graphical User Interface or directly via the I2C bus by  
using high and low level commands as described in  
the "ZM7300 Digital Power Manager Programming  
Manual”.  
8. Programmable Features  
Performance parameters of ZY7115 POL converters  
can be programmed via the industry standard I2C  
communication  
bus  
without  
replacing  
any  
components or rewiring PCB traces. Each parameter  
has a default value stored in the volatile memory  
registers detailed in Table 1. The setup registers 00h  
through 14h are programmed at the system power-  
up. When the user programs new performance  
parameters, the values in the registers are  
overwritten. Upon removal of the input voltage, the  
default values are restored.  
ZY7115 parameters can be reprogrammed at any  
time during the system operation and service except  
for the digital filter coefficients, the switching  
frequency and the duty cycle limit, that can only be  
changed when the POL is turned off.  
8.1 Output Voltage  
The output voltage can be programmed in the POL  
Configure Output window shown in the Figure 28 or  
directly via the I2C bus by writing into the VOS  
register shown in Figure 29.  
Table 1. ZY7115 Memory Registers  
Register  
Content  
Address  
PC1  
PC2  
PC3  
DON  
DOF  
TC  
Protection Configuration 1  
Protection Configuration 2  
Protection Configuration 3  
Turn-On Delay  
00h  
01h  
02h  
05h  
06h  
03h  
04h  
Turn-Off Delay  
Tracking Configuration  
Interleave Configuration and  
Frequency Selection  
INT  
RUN  
ST  
VOS  
CLS  
DCL  
B1  
RUN Register  
Status Register  
15h  
16h  
07h  
08h  
09h  
0Ah  
Output Voltage Setpoint  
Current Limit Setpoint  
Duty Cycle Limit  
Dig Controller Denominator z-1  
Coefficient  
B2  
Dig Controller Denominator z-2  
Coefficient  
0Bh  
0Ch  
0Dh  
0Eh  
0Fh  
10h  
11h  
12h  
13h  
14h  
B3  
Dig Controller Denominator z-3  
Coefficient  
C0L  
C0H  
C1L  
C1H  
C2L  
C2H  
C3L  
C3H  
Dig Controller Numerator z0  
Coefficient, Low Byte  
Dig Controller Numerator z0  
Coefficient, High Byte  
Dig Controller Numerator z-1  
Coefficient, Low Byte  
Dig Controller Numerator z-1  
Coefficient, High Byte  
Dig Controller Numerator z-2  
Coefficient, Low Byte  
Dig Controller Numerator z-2  
Coefficient, High Byte  
Dig Controller Numerator z-3  
Coefficient, High Byte  
Dig Controller Numerator z-3  
Coefficient, Low Byte  
Output Voltage Monitoring  
Output Current Monitoring  
Temperature Monitoring  
Figure 28. POL Configure Output Window  
R/W-0  
VOS7  
Bit 7  
R/W-0  
VOS6  
R/W-0  
VOS5  
R/W-0  
VOS4  
R/W-0  
VOS3  
R/W-0  
VOS2  
R/W-0  
VOS1  
R/W-0  
VOS0  
Bit 0  
Bit 7:0 VOS[7:0], Output voltage setting  
00h: corresponds to 0.5000V  
01h: corresponds to 0.5125V  
R
W
U
= Readable bit  
= Writable bit  
= Unimplemented bit,  
read as „0‟  
77h: corresponds to 1.9875V  
78h: corresponds to 2.0000V  
79h: corresponds to 2.025V  
- n = Value at POR reset  
F9h: corresponds to 5.225V  
FAh: corresponds to 5.250V  
FBh: corresponds to 5.300V  
FFh: corresponds to 5.500V  
VOM  
IOM  
TMP  
17h  
18h  
19h  
Figure 29. Output Voltage Setpoint Register VOS  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 17 of 33  
 
 
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
8.1.1  
Output Voltage Setpoint  
VOUT  
The output voltage programming range is from 0.5V  
to 5.5V. Within this range, there are 256 predefined  
voltage setpoints. To improve resolution of the output  
voltage settings, the voltage range is divided into  
three sub-ranges as shown in Table 2.  
Upper Regulation  
Limit  
Operating  
Point  
VI Curve Without  
Load Regulation  
VI Curve With  
Load Regulation  
Headroom without  
Load Regulation  
Headroom with  
Lower Regulation  
Limit  
Table 2. Output Voltage Adjustment Resolution  
VOUT MIN, V  
0.500  
VOUT MAX, V  
2.000  
5.25  
Resolution, mV  
Load Regulation  
Heavy  
Load  
Light  
Load  
IOUT  
12.5  
25  
2.025  
Figure 30. Concept of Optimal Voltage Positioning  
5.3  
5.5  
50  
Increased headroom allows tolerating larger voltage  
deviations. For example, the step load change from  
light to heavy load will cause the output voltage to  
drop. If the optimal voltage positioning is utilized, the  
output voltage will stay within the regulation window.  
Otherwise, the output voltage will drop below the  
lower regulation limit. To compensate for the voltage  
drop external output capacitance will need to be  
added, thus increasing cost and complexity of the  
system.  
8.1.2  
Output Voltage Margining  
If the output voltage needs to be varied by a certain  
percentage, the margining function can be utilized.  
The margining can be programmed in the POL  
Configure Output window or directly via the I2C bus  
using high level commands as described in the  
„”DPM Programming Manual”.  
In order to properly margin POLs that are connected  
in parallel, the POLs must be members of one of the  
Parallel Buses. Refer to the DPM Configure Devices  
window shown in Figure 56.  
The effect of optimal voltage positioning is shown in  
Figure 31 and Figure 32. In this case, switching  
output load causes large peak-to-peak deviation of  
the output voltage. By programming load regulation,  
the peak to peak deviation is dramatically reduced.  
8.1.3  
Optimal Voltage Positioning  
Optimal voltage positioning increases the voltage  
regulation window by properly positioning the output  
voltage setpoint. Positioning is determined by the  
load regulation that can be programmed in the POL  
Configure Output window shown in Figure 28 or  
directly via the I2C bus by writing into the CLS  
register shown in Figure 39.  
Figure 30 illustrates optimal voltage positioning  
concept. If no load regulation is programmed, the  
headroom (voltage differential between the output  
voltage setpoint and  
a
regulation limit) is  
approximately half of the voltage regulation window.  
When load regulation is programmed, the output  
voltage will decrease as the output current  
increases, so the VI characteristic will have a  
negative slope. Therefore, by properly selecting the  
operating point, it is possible to increase the  
headroom as shown in the picture.  
Figure 31. Transient Response without Optimal Voltage  
Positioning  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 18 of 33  
 
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
R/W-0  
DON7  
Bit 7  
R/W-0  
DON6  
R/W-0  
DON5  
R/W-0  
DON4  
R/W-0  
DON3  
R/W-0  
DON2  
R/W-0  
DON1  
R/W-0  
DON0  
Bit 0  
Bit 7:0 DON[7:0]: Turn-on delay time  
00h: corresponds to 0ms delay after turn-on command has occurred  
FFh: corresponds to 255ms delay after turn-on command has occurred  
Figure 34. Turn-On Delay Register DON  
8.2.2  
Turn-Off Delay  
U
U
R/W-0  
DOF5  
R/W-0  
DOF4  
R/W-0  
DOF3  
R/W-0  
DOF2  
R/W-0  
DOF1  
R/W-0  
DOF0  
Bit 0  
---  
---  
Bit 7  
Bit 7:6 Unimplemented, read as „0‟  
Bit 5:0 DOF[5:0]: Turn-off delay time  
Figure 32. Transient Response with Optimal Voltage  
Positioning  
00h: corresponds to 0ms delay after turn-off command has occurred  
3Fh: corresponds to 63ms delay after turn-off command has occurred  
Figure 35. Turn-Off Delay Register DOF  
8.2 Sequencing and Tracking  
Turn-on delay, turn-off delay, and rising and falling  
output voltage slew rates can be programmed in the  
POL Configure Sequencing window shown in Figure  
33 or directly via the I2C bus by writing into the DON,  
DOF, and TC registers, respectively. The registers  
are shown in Figure 34, Figure 35, and Figure 37.  
Turn-off delay is defined as an interval from the  
application of the Turn-Off command until the output  
voltage reaches zero (if the falling slew rate is  
programmed) or until both high side and low side  
switches are turned off (if the slew rate is not  
programmed). Therefore, for the slew rate controlled  
turn-off the ramp-down time is included in the turn-off  
delay as shown in Figure 36.  
User programmed turn-off delay, TDF  
Turn-Off  
Command  
Calculated  
Ramp-down time, TF  
delay TD  
Internal  
Ramp-down time, T  
ramp-down  
command  
Falling slew  
rate dVF/dT  
VOUT  
Time  
Figure 36. Relationship between Turn-Off Delay and Falling  
Slew Rate  
As it can be seen from the figure, the internally  
calculated delay TD is determined by the equation  
Figure 33. POL Configure Sequencing Window  
below.  
VOUT  
8.2.1  
Turn-On Delay  
TD TDF  
,
dVF  
Turn-on delay is defined as an interval from the  
application of the Turn-On command until the output  
voltage starts ramping up.  
dT  
For proper operation TD shall be greater than zero.  
The appropriate value of the turn-off delay needs to  
be programmed to satisfy the condition.  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 19 of 33  
 
 
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
If the falling slew rate control is not utilized, the turn-  
off delay only determines an interval from the  
application of the Turn-Off command until both high  
side and low side switches are turned off. In this  
case, the output voltage ramp-down process is  
determined by load parameters.  
U
---  
R/W-0  
R2  
R/W-0  
R1  
R/W-0  
R0  
R/W-1  
SC  
R/W-0  
F2  
R/W-0  
F1  
R/W-0  
F0  
Bit 7  
Bit 0  
Bit 7  
Unimplemented , read as „0‟  
R[2:0]  
R
W
U
= Readable bit  
= Writable bit  
= Unimplemented bit,  
Bit 6:4  
: Value of Vo rising slope  
0: corresponds to 0.1V/ms (default)  
1: corresponds to 0.2V/ms  
2: corresponds to 0.5V/ms  
3: corresponds to 1.0V/ms  
4: corresponds to 2.0V/ms  
5: corresponds to 5.0V/ms  
6: corresponds to 8.3V/ms  
7: corresponds to 8.3V/ms  
read as „0‟  
- n = Value at POR reset  
8.2.3  
Rising and Falling Slew Rates  
The output voltage tracking is accomplished by  
programming the rising and falling slew rates of the  
output voltage. To achieve programmed slew rates,  
the output voltage is being changed in 12.5mV steps  
where duration of each step determines the slew  
rate. For example, ramping up a 1.0V output with a  
slew rate of 0.5V/ms will require 80 steps duration of  
25μs each.  
SC  
Bit 3  
, Slew rate control at turn-off  
0: Slew rate control is disabled  
1: Slew rate control is enabled  
F[2:0]  
Bit 2:0  
: Value of Vo falling slope  
0: corresponds to -0.1V/ms (default)  
1: corresponds to -0.2V/ms  
2: corresponds to -0.5V/ms  
3: corresponds to -1.0V/ms  
4: corresponds to -2.0V/ms  
5: corresponds to -5.0V/ms  
6: corresponds to 8.3V/ms  
7: corresponds to 8.3V/ms  
Duration of each voltage step is calculated by  
dividing the master clock frequency generated by the  
DPM. Since all POLs in the system are synchronized  
to the master clock, the matching of voltage slew  
rates of different outputs is very accurate as it can be  
seen in Figure 11 and Figure 16.  
Figure 37. Tracking Configuration Register TC  
8.3 Protections  
ZY7115 Series converters have a comprehensive set  
of programmable protections. The set includes the  
output over- and undervoltage protections,  
overcurrent protection, overtemperature protection,  
tracking protection, overtemperature warning, and  
Power Good signal. Status of protections is stored in  
the ST register shown in Figure 38.  
During the turn on process, a POL not only delivers  
current required by the load (ILOAD), but also charges  
the load capacitance. The charging current can be  
determined from the equation below:  
dVR  
ICHG CLOAD  
dt  
R-1  
TP  
R-0  
PG  
R-1  
TR  
R-1  
OT  
R-1  
OC  
R-1  
UV  
R-1  
OV  
R-1  
PV  
Where, CLOAD is load capacitance, dVR/dt is rising  
voltage slew rate, and ICHG is charging current.  
Bit 7  
Bit 0  
When selecting the rising slew rate, a user needs to  
ensure that  
TP  
Bit 7  
: Temperature Warning  
R
W
U
= Readable bit  
= Writable bit  
= Unimplemented bit,  
PG  
TR  
OT  
OC  
UV  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Note:  
: Power Good Warning  
: Tracking Fault  
read as „0‟  
: Overtemperature Fault  
: Overcurrent Fault  
- n = Value at POR reset  
ILOAD ICHG IOCP  
: Undervoltage Fault  
Where IOCP is the overcurrent protection threshold of  
the ZY7115. If the condition is not met, then the  
overcurrent protection will be triggered during the  
turn-on process. To avoid this, dVR/dt and the  
overcurrent protection threshold should be  
programmed to meet the condition above.  
OV: Overvoltage Error  
PV  
: Phase Voltage Error  
- An activated warning/fault/error is encoded as „0‟  
Figure 38. Protection Status Register ST  
Thresholds of overcurrent, over- and undervoltage  
protections, and Power Good limits can be  
programmed in the POL Configure Output window or  
directly via the I2C bus by writing into the CLS and  
PC2 registers shown in Figure 39 and Figure 40.  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 20 of 33  
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
R/W-0  
LR2  
R/W-0  
LR1  
R/W-0  
LR0  
R/W-1  
TCE  
R/W-1  
CLS3  
R/W-0  
CLS2  
R/W-1  
CLS1  
R/W-1  
CLS0  
Bit 0  
Bit 7  
Bit 7:5 LR[2:0], Load regulation configuration  
000: 0 V/A/Ohm  
R
W
U
= Readable bit  
= Writable bit  
= Unimplemented bit,  
read as „0‟  
001: 0.39 V/A/Ohm  
010: 0.78 V/A/Ohm  
011: 1.18 V/A/Ohm  
100: 1.57 V/A/Ohm  
- n = Value at POR reset  
101: 1.96 V/A/Ohm  
110: 2.35 V/A/Ohm  
111: 2.75 V/A/Ohm  
Bit 4  
TCE, Temperature compensation enable  
0: disabled  
1: enabled  
Bit 3:0 CLS[3:0], Current limit setting  
0h: corresponds to 37%  
1h: corresponds to 47%  
Bh: corresponds to 140%  
Values higher than Bh are translated to Bh (140%)  
Figure 41. POL Configure Fault Window  
Figure 39. Current Limit Setpoint Register CLS  
R/W-0  
TRE  
R/W-1  
PVE  
R/W-0  
TRP  
R/W-0  
OTP  
R/W-0  
OCP  
R/W-0  
UVP  
R/W-1  
OVP  
R/W-1  
PVP  
U
---  
U
U
R/W-0  
PGLL  
R/W-1  
R/W-0  
R/W-0  
R/W-0  
---  
---  
OVPL1 OVPL0 UVPL1 UVPL0  
Bit 0  
Bit 7  
Bit 0  
Bit 7  
Bit 7  
TRE: Tracking fault enable  
1 = enabled  
0 = disabled  
R
W
U
= Readable bit  
= Writable bit  
= Unimplemented bit,  
Bit 7:5 Unimplemented, read as „0‟  
R
W
U
= Readable bit  
= Writable bit  
= Unimplemented bit,  
read as „0‟  
Bit 4  
PGLL: Set Power Good Low Level  
1 = 95% of Vo  
read as „0‟  
PVE  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
: Phase voltage error enable  
0 = 90% of Vo (Default)  
- n = Value at POR reset  
1 = enabled  
0 = disabled  
- n = Value at POR reset  
Bit 3:2 OVPL[1:0]: Set Over Voltage Protection  
Level  
TRP  
: Tracking fault protection  
00 = 110% of Vo  
01 = 120% of Vo  
10 = 130% of Vo (Default)  
11 = 130% of Vo  
1 = latching  
0 = non latching  
OTP  
: Overtemperature protection configuration  
1 = latching  
0 = non latching  
Bit 1:0 UVPL[1:0]: Set Under Voltage Protection Level  
00 = 75% of Vo (Default)  
01 = 80% of Vo  
10 = 85% of Vo  
OCP  
: Overcurrent protection configuration  
1 = latching  
0 = non latching  
Figure 40. Protection Configuration Register PC2  
UVP  
: Undervoltage protection configuration  
1 = latching  
0 = non latching  
Note that the overvoltage and undervoltage  
protection thresholds and Power Good limits are  
defined as percentages of the output voltage.  
Therefore, the absolute levels of the thresholds  
change when the output voltage setpoint is changed  
either by output voltage adjustment or by margining.  
OVP  
: Overvoltage protection configuration  
1 = latching  
0 = non latching  
PVP  
: Phase Voltage Protection  
1 = latching  
0 = non latching  
Figure 42. Protection Configuration Register PC1  
In addition, a user can change type of protections  
(latching or non-latching) or disable certain  
protections. These settings are programmed in the  
DPM Configure Fault window shown in Figure 41 or  
directly via the I2C by writing into the PC1 register  
shown in Figure 42.  
If the non-latching protection is selected, a POL will  
attempt to restart every 130ms until the condition  
that triggered the protection is removed. When  
restarting, the output voltages follow tracking and  
sequencing settings.  
If the latching type is selected, a POL will turn off and  
stay off. The POL can be turned on after 130ms, if  
the condition that caused the fault is removed and  
the respective bit in the ST register was cleared, or  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 21 of 33  
 
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
the status information from each POL on a continuous  
basis.  
the Turn On command was recycled, or the input  
voltage was recycled.  
8.3.2  
Faults  
All protections can be classified into three groups  
based on their effect on system operation: warnings,  
faults, and errors.  
This group includes overcurrent, overtemperature,  
undervoltage, and tracking protections. Triggering  
any protection in this group will turn off the POL.  
8.3.1  
Warnings  
8.3.2.1  
Overcurrent Protection  
This group includes Overtemperature Warning and  
Power Good Signal. The warnings do not turn off  
POLs but rather generate signals that can be  
transmitted to a host controller via the I2C bus.  
Overcurrent protection is active whenever the output  
voltage of the POL exceeds the pre-bias voltage (if  
any). When the output current reaches the OC  
threshold, the output voltage will start decreasing. As  
soon as the output voltage decreases below the  
undervoltage protection threshold, the OC fault  
signal is generated, the POL turns off and the OC bit  
in the register ST is changed to 0. Both high side and  
low side switches of the POL are turned off instantly  
(fast turn-off).  
8.3.1.1  
Overtemperature Warning  
The Overtemperature Warning is generated when  
temperature of the controller exceeds 120°C. The  
Overtemperature Warning changes the PT bit of the  
status register ST to 0 and sends the signal to the  
DPM. Reporting is enabled in the DPM Configure  
Faults window or directly via the I2C by writing into  
the PC3 register shown in Figure 44. When the  
temperature falls below 117°C, the PT bit is cleared  
and the Overtemperature Warning is removed.  
The temperature compensation is added to keep the  
OC  
temperatures above room temperature. Note that the  
temperature compensation can be disabled in the  
POL Configure Output window or directly via the I2C  
by writing into the CLS register. However, it is  
threshold  
approximately  
constant  
at  
8.3.1.2  
Power Good  
recommended  
compensation enabled.  
to  
keep  
the  
temperature  
Power Good is an open collector output that is pulled  
low, if the output voltage is outside of the Power  
Good window. The window is formed by the Power  
Good High threshold that is equal to 110% of the  
output voltage and the Power Good Low threshold  
that can be programmed at 90 or 95% of the output  
voltage.  
8.3.2.2  
Undervoltage Protection  
The undervoltage protection is only active during  
steady state operation of the POL to prevent  
nuisance tripping. If the output voltage decreases  
below the UV threshold and there is no OC fault, the  
UV fault signal is generated, the POL turns off, and  
the UV bit in the register ST is changed to 0. The  
output voltage is ramped down according to  
sequencing and tracking settings (regular turn-off).  
The Power Good protection is only enabled after the  
output voltage reaches its steady state level. The PG  
pin is pulled low during transitions of the output  
voltage from one level to other as shown in Figure  
43.  
8.3.2.3  
Overtemperature Protection  
The Power Good Warning pulls the Power Good pin  
low and changes the PG bit of the status register ST  
to 0. It sends the signal to the DPM, if the reporting is  
enabled. When the output voltage returns within the  
Power Good window, the PG pin is pulled high, the  
PG bit is cleared and the Power Good Warning is  
removed. The Power Good pin can also be pulled  
low by an external circuit to initiate the Power Good  
Warning.  
Overtemperature protection is active whenever the  
POL is powered up. If temperature of the controller  
exceeds 130°C, the OT fault is generated, POL turns  
off, and the OT bit in the register ST is changed to 0.  
The output voltage is ramped down according to  
sequencing and tracking settings (regular turn-off).  
If non-latching OTP is programmed, the POL will  
restart as soon as the temperature of the controller  
decreases below the Overtemperature Warning  
threshold of 120°C.  
Note: To retrieve status information, Status Monitoring in the DPM  
Configure Devices window should be enabled (refer to  
Digital Power Manager Data Sheet). The DPM will retrieve  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 22 of 33  
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
8.3.2.4  
Tracking Protection  
value of the difference exceeds 250mV, the tracking  
fault signal is generated, the POL turns off, and the  
TR bit in the register ST is changed to 0. Both high  
side and low side switches of the POL are turned off  
instantly (fast turn-off).  
Tracking protection is active only when the output  
voltage is ramping up. The purpose of the protection  
is to ensure that the voltage differential between  
multiple rails being tracked does not exceed 250mV.  
This protection eliminates the need for external  
clamping diodes between different voltage rails  
which are frequently recommended by ASIC  
manufacturers.  
The tracking protection can be disabled, if it  
contradicts requirements of a particular system (for  
example turning into high capacitive load where  
rising slew rate is not important). It can be disabled  
in the DPM Configure Faults window or directly via  
the I2C bus by writing into the PC1 register.  
When the tracking protection is enabled, the POL  
continuously compares actual value of the output  
voltage to its programmed value as defined by the  
output voltage and its rising slew rate. If absolute  
Vo  
1
Enable command  
OTP  
0
continuously enabled  
1
0
OCP enabled  
1
0
Power Good  
Signal  
OVP Threshold  
OVP Threshold  
PG High=110%VOUT  
PG High=110%VOUT  
OVP Threshold  
Output Voltage  
Output Voltage  
PG High=110%VOUT  
Output Voltage  
PG Low Threshold  
UVP Threshold  
PG Low Threshold  
UVP Threshold  
PG Low Threshold  
1.0V  
prebiased output  
UVP Threshold  
Tracking  
Thresholds  
Time  
Figure 43. Protections Enable Conditions  
8.3.3  
Errors  
The OV threshold can be programmed from 110% to  
130% of the output voltage setpoint, but not lower  
than 1.0V.  
The group includes overvoltage protection and the  
phase voltage error. The phase voltage error is not  
available in ZY7115.  
8.3.4  
Faults and Errors Propagation  
8.3.3.1  
Overvoltage Protection  
The feature adds flexibility to the fault management  
scheme by giving users control over propagation of  
fault signals within and outside of the system. The  
propagation means that a fault in one POL can be  
programmed to turn off other POLs and devices in  
the system, even if they are not directly affected by  
the fault.  
The overvoltage protection is active whenever the  
output voltage of the POL exceeds the pre-bias  
voltage (if any). If the output voltage exceeds the  
overvoltage protection threshold, the overvoltage  
error signal is generated, the POL turns off, and the  
OV bit in the register ST is changed to 0. The high  
side switch is turned off instantly, and simultaneously  
the low side switch is turned on to ensure reliable  
protection of sensitive loads. The low side switch  
provides low impedance path to quickly dissipate  
energy stored in the output filter and achieve  
effective voltage limitation.  
8.3.4.1  
Grouping of POLs  
ZY-Series POLs can be arranged in several groups  
to simplify fault management. A group of POLs is  
defined as a number of POLs with interconnected  
OK pins. A group can include from 1 to 32 POLs. If  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 23 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
fault propagation within a group is desired, the  
propagation bit needs to be checked in the DPM  
Configure Faults Window. The parameters can also  
be programmed directly via the I2C bus by writing  
into the PC3 register shown in Figure 44.  
When propagation is enabled, the faulty POL pulls its  
OK pin low. A low OK line initiates turn-off of other  
POLs in the group.  
R/W-0  
PTM  
Bit 7  
R/W-0  
PGM  
R/W-1  
TRP  
R/W-1  
OTP  
R/W-1  
OCP  
R/W-1  
UVP  
R/W-1  
OVP  
R/W-1  
PVP  
Bit 0  
PTM  
1 = enabled  
0 = disabled  
Bit 7  
: Temperature warning Message  
R
W
U
= Readable bit  
= Writable bit  
= Unimplemented bit,  
Figure 45. DPM Configure Faults Window  
read as „0‟  
- n = Value at POR reset  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
PGM: Power good message  
1 = enabled  
0 = disabled  
In this case low OK line will signal DPM to pull other  
OK lines low to initiate shutdown of other POLs as  
programmed in the DPM Configure Faults window. If  
an error is propagated, the DPM can also generate  
commands to turn off a front end (a DC-DC  
converter generating the intermediate bus voltage)  
and trigger an optional crowbar protection to  
accelerate removal of the IBV voltage.  
TRP  
: Tracking fault propagation  
1 = enabled  
0 = disabled  
OTP  
: Overtemperature fault propagation  
1 = enabled  
0 = disabled  
OCP  
: Overcurrent fault propagation  
1 = enabled  
0 = disabled  
UVP  
: Undervoltage fault propagation  
1 = enabled  
0 = disabled  
8.3.4.2  
Propagation Process  
Propagation of a fault (OCP, UVP, OTP, and TRP)  
initiates regular turn-off of other POLs. The faulty  
POL in this case performs either the regular or the  
fast turn-off depending on a specific fault as  
described in section 8.3.2.  
OVP  
: Overvoltage error propagation  
1 = enabled  
0 = disabled  
PVP: Phase voltage error propagation  
1 = enabled  
0 = disabled  
Figure 44. Protection Configuration Register PC3  
Propagation of an error initiates fast turn-off of other  
POLs. The faulty POL performs the fast turn-off and  
turns on its low side switch.  
In addition, the OK lines can be connected to the  
DPM to facilitate propagation of faults and errors  
between groups. One DPM can control up to 4  
independent groups. To enable fault propagation  
between groups, the respective bit needs to be  
checked in the DPM Configure Faults window, Group  
Fault Propagation sub window shown in Figure 45.  
Example of the fault propagation is shown in Figure  
46 - Figure 47. In this three-output system (refer to  
the block diagram in Figure 26), the POL powering  
the output V3 (Ch 1 in the picture) encounters the  
undervoltage fault after the turn-on. When the fault  
propagation is not enabled, the POL turns off and  
generates the UV fault signal. Because the UV fault  
triggers the regular turn off, the POL meets its turn-  
off delay and falling slew rate settings during the  
turn-ff process as shown in Figure 46. Since the UV  
fault is programmed to be non-latching, the POL will  
attempt to restart every 130ms, repeating the  
process described above until the condition causing  
the undervoltage is removed.  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 24 of 33  
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
If the fault propagation between groups is enabled,  
the POL powering the output V3 pulls its OK line low  
and the DPM propagates the signal to the POL  
powering the output V1 that belongs to other group.  
The POL powering the output V1 (Ch3 in the picture)  
executes the regular turn-off. Since both V1 and V3  
have the same delay and slew rate settings they will  
continue to turn off and on synchronously every  
130ms as shown in Figure 47 until the condition  
causing the undervoltage is removed. The POL  
powering the output V2 continues to ramp up until it  
reaches its steady state level.  
130ms is the interval from the instant of time when  
the output voltage ramps down to zero until the  
output voltage starts to ramp up again. Therefore,  
the 130ms hiccup interval is guaranteed regardless  
of the turn-off delay setting.  
Figure 47. Turn-On into UVP on V3. The UV Fault Is  
Programmed To Be Non-Latching and Propagate  
From Group C to Group A. Ch1 V3 (Group C),  
Ch2 V2, Ch3 V1 (Group A)  
Summary of protections, their parameters and  
features are shown in Table 3  
Figure 46. Turn-On into UVP on V3. The UV Fault Is  
Programmed To Be Non-Latching. Ch1 V3 (Group  
C), Ch2 V2, Ch3 V1 (Group A)  
Table 3. Summary of Protections Parameters and Features  
Code  
PT  
Name  
Type  
When Active  
Turn  
Off  
Low Side  
Switch  
Propagation  
Disable  
No  
Temperature  
Warning  
Power Good  
Warning  
Warning  
Whenever VIN is applied  
During steady state  
No  
N/A  
Readable by  
DPM  
Readable by  
DPM  
PG  
No  
N/A  
No  
TR  
OT  
OC  
UV  
OV  
Tracking  
Overtemperature  
Overcurrent  
Fault  
Fault  
Fault  
Fault  
Error  
During ramp up  
Fast  
Regular  
Fast  
Off  
Off  
Off  
Off  
On  
Regular turn off  
Regular turn off  
Regular turn off  
Regular turn off  
Fast turn off  
Yes  
No  
No  
No  
No  
Whenever VIN is applied  
When VOUT exceeds prebias  
During steady state  
Undervoltage  
Overvoltage  
Regular  
Fast  
When VOUT exceeds prebias  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 25 of 33  
 
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
8.4 PWM Parameters  
R/W-0  
FRQ2  
Bit 7  
R/W-0  
FRQ1  
R/W-0  
FRQ0  
R/W-01) R/W-01) R/W-01) R/W-01) R/W-01)  
INT4  
INT3  
INT2  
INT1  
INT0  
Bit 0  
Z-Series POLs utilize the digital PWM controller. The  
controller enables users to program most of the  
PWM performance parameters, such as switching  
frequency, interleave, duty cycle, and feedback loop  
compensation.  
Bit 7:5 FRQ[2:0]: PWM Frequency Selection  
000: 500kHz  
R
W
U
= Readable bit  
= Writable bit  
= Unimplemented bit,  
001: 750kHz  
010: 1000lHz  
011: 1250kHz  
100: 1250kHz  
read as „0‟  
- n = Value at POR reset  
101: 1500kHz  
110: 1750kHz  
111: 2000kHz  
8.4.1  
Switching Frequency  
The switching frequency can be programmed in the  
POL Controller Compensation window shown in  
Figure 48 or directly via the I2C bus by writing into  
the INT register shown in Figure 49. Note that the  
content of the register can be changed only when the  
POL is turned off.  
INT[4:0]  
Bit 4:0  
: Interleave position  
00h: Ton starts with 0.0° Phase lag to SD Line  
01h: Ton starts wi th 11.25° Phase lag to SD Line  
02h: Ton starts with 22.50° Phase lag to SD Line  
1Fh: Ton starts with 348.75° Phase lag to SD Line  
1) Initial value depends on the state of the Interleave Mode (  
IM=Open: At POR reset the 5 corresponding ADDRESS bits are loaded  
IM=Low: At POR reset a 0 is loaded  
) Input:  
IM  
Switching actions of all POLs connected to the SD  
line are synchronized to the master clock generated  
by the DPM. Each POL is equipped with a PLL and a  
frequency divider so they can operate at multiples  
(including fractional) of the master clock frequency  
as programmed by a user. The POL converters can  
operate at 500 kHz, 750 kHz, and 1 MHz. Although  
synchronized, switching frequencies of different  
POLs are independent of each other. It is  
permissible to mix POLs operating at different  
frequencies in one system. It allows optimizing  
efficiency and transient response of each POL in the  
system individually.  
Figure 49. Interleave Configuration Register INT  
8.4.2  
Interleave  
Interleave is defined as a phase delay between the  
synchronizing slope of the master clock on the SD  
pin and PWM signal of a POL. The interleave can be  
programmed in the POL Configure Controller  
Compensation window or directly via the I2C bus by  
writing into the INT register.  
Every POL generates switching noise. If no  
interleave is programmed, all POLs in the system  
switch simultaneously and noise reflected to the  
input source from all POLs is added together as  
shown in Figure 50.  
Figure 48. POL Configure Controller Compensation Window  
Figure 50. Input Voltage Noise, No Interleave  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 26 of 33  
 
 
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
Figure 51 shows the input voltage noise of the three-  
output system with programmed interleave. Instead  
of all three POLs switching at the same time as in  
the previous example, the POLs V1, V2, and V3  
switch at 67.5°, 180°, and 303.75°, respectively.  
Noise is spread evenly across the switching cycle  
resulting in more than 1.5 times reduction. To  
achieve similar noise reduction without the interleave  
will require the addition of an external LC filter.  
Figure 53. Output Voltage Noise, Full Load, 180Interleave  
The ZY7115 interleave feature is similar to that of  
multiphase converters, however, unlike in the case of  
multiphase converters, interleave does not have to  
be equal to 360/N, where N is the number of POLs in  
a system. ZY7115 interleave is independent of the  
number of POLs in  
a
system and is fully  
programmable in 11.25steps. It allows maximum  
output noise reduction by intelligently spreading  
switching energy.  
Figure 51. Input Voltage Noise with Interleave  
Note: Due to noise sensitivity issues that may occur in limited  
cases, it is recommended to avoid phase lag settings of  
112.5 and 123.75 degrees, otherwise false PG and/or OV  
indications may occur.  
Similar noise reduction can be achieved on the  
output of POLs connected in parallel. Figure 52 and  
Figure 53 show the output noise of two ZY7115s  
connected in parallel without and with 180°  
interleave, respectively. Resulting noise reduction is  
more than 2 times and is equivalent to doubling  
switching frequency or adding extra capacitance on  
the output of the POLs.  
8.4.3  
Duty Cycle Limit  
The ZY7115 is a step-down converter therefore VOUT  
is always less than VIN. The relationship between the  
two parameters is characterized by the duty cycle  
and can be estimated from the following equation:  
VOUT  
DC   
,
VIN.MIN  
Where, DC is the duty cycle, VOUT is the required  
maximum output voltage (including margining),  
VIN.MIN is the minimum input voltage.  
It is good practice to limit the maximum duty cycle of  
the controller's PWM to a somewhat higher value  
compared to the steady-state duty cycle as  
expressed by the above equation. This will further  
protect the output from excessive voltages. The duty  
cycle limit can be programmed in the POL Configure  
Controller Compensation window or directly via the  
Figure 52. Output Voltage Noise, Full Load, No Interleave  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 27 of 33  
 
 
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
I2C bus by writing into the DCL register shown in  
Figure 54.  
8.4.5  
Feedback Loop Compensation  
Feedback loop compensation can be programmed in  
the GUI POL Configure Controller Compensation  
window by setting frequency of poles and zeros of  
the transfer function.  
R/W-1  
DCL5  
Bit 7  
R/W-1  
DCL4  
R/W-1  
DCL3  
R/W-0  
DCL2  
R/W-1  
DCL1  
R/W-0  
DCL0  
R/W-0  
HI  
R/W-0  
LO  
Bit 0  
The transfer function of the POL converter is shown  
in Figure 55. It is a third order function with two zeros  
and three poles. Pole 1 is the integrator pole, Pole 2  
is used in conjunction with Zero 1 and Zero 2 to  
adjust the phase lead and limit the gain increase in  
mid band. Pole 3 is used as a high frequency low-  
pass filter to limit PWM noise.  
R
W
U
= Readable bit  
= Writable bit  
= Unimplemented bit,  
Bit 7:2 DCL[5:0], Duty Cycle Limitation  
00h: 0  
01h: 1/64  
read as „0‟  
- n = Value at POR reset  
3Fh: 63/64  
Bit 1: HI, ADC high saturation feed-forward  
0: disabled  
1: enabled  
Bit 0: LO, ADC low saturation feed-forward  
0: disabled  
1: enabled  
Magnitude[dB]  
Figure 54. Duty Cycle Limit Register  
50  
40  
30  
20  
10  
Z1 P1 Z2 P2  
P3  
P1: Pole 1  
P2: Pole 3  
P3: Pole 3  
Z1: Zero 1  
Z2: Zero 2  
8.4.4  
ADC Saturation Feedforward  
To speed up the PWM response in case of heavy  
dynamic loads, the duty cycle can be forced either to  
0 or the duty cycle limit depending on the polarity of  
the transient. This function is equivalent to having  
two comparators defining a window around the  
output voltage setpoint. When an error signal is  
inside the window, it will produce gradual duty cycle  
change proportional to the error signal. If the error  
signal goes outside the window (usually due to large  
output current steps), the duty cycle will change to its  
limit in one switching cycle. In most cases this will  
significantly improve transient response of the  
controller, reducing amount of required external  
capacitance.  
Freq  
[kHz]  
0.1  
0.1  
1
1
10  
10  
100  
1000  
1000  
Phase  
[°]  
+45  
Freq  
[kHz]  
0
-45  
100  
-90  
-135  
-180  
Figure 55. Transfer Function of PWM  
Under certain circumstances, usually when the  
maximum duty cycle limit significantly exceeds its  
nominal value, the ADC saturation can lead to the  
overcompensation of the output error. The  
phenomenon manifests itself as low frequency  
oscillations on the output of the POL. It can usually  
be reduced or eliminated by disabling the ADC  
saturation or limiting the maximum duty cycle to 120-  
140% of the calculated value. It is not recommended  
to use ADC saturation for output voltages higher  
than 2.0V.  
Positions of poles and zeroes are determined by  
coefficients of the digital filter. The filter is  
characterized by four numerator coefficients (C0, C1,  
C2, C3) and three denominator coefficients (B1, B2,  
B3). The coefficients are automatically calculated  
when desired frequency of poles and zeros is  
entered in the GUI POL Configure Controller  
Compensation window. The coefficients are stored in  
the C0H, C0L, C1H, C1L, C2H, C2L, C3H, C3L, B1,  
B2, and B3 registers.  
Note: The GUI automatically transforms zero and pole  
frequencies into the digital filter coefficients. It is strongly  
recommended to use the GUI to determine the filter  
coefficients.  
The ADC saturation feedforward can be  
programmed in the POL Configure Controller  
Compensation window or directly via the I2C bus by  
writing into the DCL register.  
Programming feedback loop compensation allows  
optimizing POL performance for various application  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 28 of 33  
 
 
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
conditions. For example, increase in bandwidth can  
8.6 Performance Parameters Monitoring  
significantly improve dynamic response.  
The POL converters can monitor their own  
performance parameters such as output voltage,  
output current, and temperature.  
8.5 Current Share  
The POL converters are equipped with the digital  
current share function. To activate the current share,  
interconnect the CS pins of the POLs connected in  
parallel. The digital signal transmitted over the CS  
line sets output currents of all POLs to the same  
level.  
The output voltage is measured at the output sense  
pins, output current is measured using the ESR of  
the output inductor and temperature is measured by  
the thermal sensor built into the controller IC. Output  
current readings are adjusted based on temperature  
readings to compensate for the change of ESR of  
the inductor with temperature.  
When POLs are connected in parallel, they must be  
included in the same parallel bus in the DPM  
Configure Devices window shown in Figure 56. In  
this case, the GUI automatically copies critical  
parameters of one POL onto all POLs connected to  
the parallel bus. It makes it impossible to configure  
different performance parameters for POLs  
connected in parallel except for interleave and load  
regulation settings that are independent. The  
interleave allows to reduce and move the output  
noise of the converters connected in parallel to  
higher frequencies as shown in Figure 52 and Figure  
53. The load regulation allows controlling the current  
share loop gain in case of small signal oscillations. It  
is recommended to always add a small amount of  
load regulation to one of the converters connected in  
parallel to reduce loop gain and therefore improve  
stability.  
An 8-Bit Analog to Digital Converter (ADC) converts  
the output voltage, output current, and temperature  
into a digital signal to be transmitted via the serial  
interface. The ADC allows a minimum sampling  
frequency of 1 kHz for all three values.  
Monitored parameters are stored in registers (VOM,  
IOM, and TMON) that are continuously updated. If  
the Retrieve Monitoring bits in the DPM Configure  
Devices window shown in Figure 56 are checked,  
those registers are being copied into the ring buffer  
located in the DPM. Contents of the ring buffer can  
be displayed in the DPM Monitor Window shown in  
Figure 57 or it can be read directly via the I2C bus  
using high and low level commands as described in  
the "ZM7300 Digital Power Manager Programming  
Manual”.  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 29 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
Figure 56. DPM Configure Devices Window  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 30 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
Figure 57. DPM Monitor Window  
chassis ground trace (if applicable) must be capable  
of conducting a current of 1.5 times the value of the  
fuse without opening. The fuse must not be placed in  
the grounded input line.  
9. Safety  
The ZY7115 POL converters do not provide  
isolation from input to output. The input devices  
powering ZY7115 must provide relevant isolation  
requirements according to all IEC60950 based  
standards. Nevertheless, if the system using the  
converter needs to receive safety agency approval,  
certain rules must be followed in the design of the  
system. In particular, all of the creepage and  
clearance requirements of the end-use safety  
requirements must be observed. These requirements  
are included in UL60950 - CSA60950-00 and  
EN60950, although specific applications may have  
other or additional requirements.  
Abnormal and component failure tests were  
conducted with the POL input protected by a fast-  
acting 65 V, 15 A, fuse. If a fuse rated greater than  
15 A is used, additional testing may be required.  
In order for the output of the ZY7115 POL converter  
to be considered as SELV (Safety Extra Low  
Voltage), according to all IEC60950 based  
standards, the input to the POL needs to be supplied  
by an isolated secondary source providing a SELV  
also.  
The ZY7115 POL converters have no internal fuse. If  
required, the external fuse needs to be provided to  
protect the converter from catastrophic failure. Refer  
to the “Input Fuse Selection for DC/DC converters”  
application note on www.power-one.com for proper  
selection of the input fuse. Both input traces and the  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 31 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
10. Mechanical Drawings  
All Dimensions are in mm  
Tolerances:  
0.5-10  
0.1  
10-100 0.2  
Pin Coplanarity: 0.1 max  
10  
SMT Pickup Tab  
13.4  
14±0.3  
2.5  
0.6  
3.4  
1.27  
0.6  
0.4  
(x20)  
1.27  
(x10)  
0.25  
2.54  
(x10)  
1.5  
4.3  
27.94  
2.03  
Tilt Specification:  
<5° from vertical,  
after assembly  
32±0.3  
9.75  
12  
12  
10.25  
9.1  
3.5  
8.25±0.3  
1.5±0.1  
3.25  
Pin 1  
SMT Pickup  
Center Point  
15.75  
Figure 58. Mechanical Drawing  
Figure 59. Pinout Diagram (Bottom View)  
www.power-one.com  
MDS-0006 Rev. 3.8, 5-May-2011  
Page 32 of 33  
ZY7115 15A DC-DC Intelligent POL Data Sheet  
3V to 13.2V Input 0.5V to 5.5V Output  
8.6  
32  
4
10  
10  
6
1.2  
(x 3)  
Unexposed thermal copper  
area associated with each pad  
must be free from other traces  
6
9
1.8  
(x 22)  
Pin 1  
2
1.27  
1.27  
2.54  
2.03  
(x 10)  
(x 10)  
0.8  
Figure 60. Recommended Pad Sizes  
8.6  
8.6  
8.6  
10  
10  
0.45mm Ø Thermal Via x 16  
0.45mm Ø Thermal Via x 16  
0.45mm Ø Thermal Via x 16  
Recommended via diameter is 0.45mm Barrel wall plating of > 25um Pitch <1.00mm  
Figure 61. Recommended PCB Layout for Multilayer PCBs  
Notes:  
1. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical  
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written  
consent of the respective divisional president of Power-One, Inc.  
2. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on  
the date manufactured. Specifications are subject to change without notice.  
I2C is a trademark of Philips Corporation.  
MDS-0006 Rev. 3.8, 5-May-2011  
www.power-one.com  
Page 33 of 33  

相关型号:

ZY7115HG-T2

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-25
BEL

ZY7115HG-T3

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-25
BEL

ZY7115L-T1

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PACKAGE-25
BEL

ZY7115L-T2-G

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-25
BEL

ZY7115L-T3-G

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-25
BEL

ZY7115LG-T1

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-25
BEL

ZY7115LG-T2

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-25
BEL

ZY7115LG-T3

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-25
BEL

ZY7115N-T1

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

ZY7115N-T2

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

ZY7115N-T3

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

ZY7120

20A DC-DC Intelligent POL Data Sheet 3V to 13.2V Input 0.5V to 5.5V Output
POWER-ONE