Features  
Compact design ideal for limited spaces  
Standards compliance:  
RoHS compliant*  
50 kA max. discharge current rating  
Multi-pole uni-block design  
DIN Rail mountable  
UL 60691 compliant integrated thermal  
disconnect  
Visual fault indicator  
Remote signalling capability  
1250 Series General Duty AC Surge Protective Device  
General Information  
Electrical Diagram  
®
L/N  
. . .  
The Bourns Model 1250 Series is a general duty Surge Protective Device (SPD)  
designed to protect high risk electrical service entrance and branch panels. This SPD is  
intended to be installed at the front end of the installation, in the main switchboard, close  
to sensitive terminals or in installations without LPS (lightning rods).  
C
V : High energy varistor  
Ft : Thermal fuse  
Ft  
C : Remote signaling contact  
t° : Thermal disconnection system  
The Model 1250 Series is a single-pole module that can be configured for both common  
mode and differential mode protection in single and three phase applications up to 480 V.  
V
Electrical Characteristics  
Model No.  
Characteristic  
1250-xS-120  
1250-xS-230  
1250-xS-400  
220/380 V,  
277/480 V,  
347/600 V  
1250-xS-480  
120/240 V,  
120/208 V  
220/380 V,  
347/600 V,  
480 V  
AC Network  
240/415 V  
Connection Mode  
1-Pole, L-N or L-G  
AC System  
IT, TT, TN, Single, Split Phase, Delta, Wye  
Max. Operating Voltage (MCOV)  
TOV Withstand  
150 V  
150 V  
275 V  
275 V  
400 V  
400 V  
550 V  
550 V  
Leakage Current at Uc  
Follow Current  
< 1 mA  
None  
20 kA  
50 kA  
--  
UL Nominal Discharge Current (In)  
15 Impulses 8/20 µs  
Max. Discharge Current (I  
1 Impulse 8/20 µs  
)
max  
Max. Lightning Current (I  
1 Impulse 10/350 µs  
)
imp  
UL Voltage Protection Rating (VPR)  
Protection Level (Up)  
700 V  
0.9 kV  
1000 V  
1.25 kV  
1200 V  
1.8 kV  
1800 V  
2.5 kV  
UL Short-Circuit Current Rating (SCCR)  
100kAIC  
General Characteristics  
Model No.  
Characteristic  
1250-xS-120  
1250-xS-230  
1250-xS-400  
1250-xS-480  
Thermal Disconnector  
Overcurrent Protection  
Connection  
UL 60691  
Time Delay - 125 A Max.  
By Screw Terminals, #6 AWG Max.  
Dimensions  
90 x 18 x 67 mm / (3.543 x 0.709 x 2.638 In.)  
DIN Rail, 35 mm Symmetrical  
250 Vac Max., 2 A  
Mounting  
Remote Signal Indicator  
Enclosure Material  
Thermoplastic UL 94V0  
Environmental Characteristics  
Model No.  
Characteristic  
1250-xS-120  
1250-xS-230  
1250-xS-400  
1250-xS-480  
Operating Temperature  
Operating Altitude  
-50 °C to +85 °C  
13,000 ft. (4,000 m)  
5 to 95 % Non-condensing, up to 100 % External  
IP 20  
Relative Humidity  
Environmental Rating  
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.  
Specifications are subject to change without notice.  
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.  
Users should verify actual device performance in their specific applications.  
Applications  
Electrical service entrance  
Branch panels  
1250 Series General Duty AC Surge Protective Device  
Product Dimensions and Schematics  
1250-1S-xxx  
10.6  
67.0  
18.0  
(.709)  
(.417)  
(2.638)  
L/N  
L/N  
Mi  
Ft  
t°  
AC Surge  
Protector  
SPD1250-xxx  
90.0  
(3.543)  
Uc  
V
In  
Imax  
Up  
C
1250-2S-xxx  
67.0  
(2.638)  
36.0  
(1.417)  
L/N  
L/N  
90.0  
(3.543)  
L
N
Mi  
Mi  
Ft  
Ft  
MM  
(INCHES)  
DIMENSIONS:  
t°  
t°  
AC Surge  
Protector  
SPD1250-xxx SPD1250-xxx  
AC Surge  
Protector  
Uc  
Uc  
V
V
In  
In  
Imax  
Up  
Imax  
Up  
44.0  
(1.732)  
10.6  
(.417)  
C
60.8  
(2.394)  
1250-3S-xxx  
54.0  
(2.126)  
L1  
L2  
L3  
L
L
L
Mi  
Mi  
Mi  
Ft  
Ft  
Ft  
t°  
t°  
t°  
AC Surge  
Protector  
AC Surge  
Protector  
AC Surge  
Protector  
SPD1250-xxx SPD1250-xxx SPD1250-xxx  
Uc  
Uc  
Uc  
V
V
V
In  
In  
In  
Imax  
Up  
Imax  
Up  
Imax  
Up  
C
Specifications are subject to change without notice.  
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.  
Users should verify actual device performance in their specific applications.  
1250 Series General Duty AC Surge Protective Device  
Product Dimensions and Schematics (Continued)  
1250-4S-xxx  
72.0  
(2.835)  
L/N  
L/N  
L/N  
L/N  
L
L
L
N
Mi  
Mi  
Mi  
Mi  
Ft  
Ft  
Ft  
Ft  
t°  
t°  
t°  
t°  
AC Surge  
Protector  
AC Surge  
Protector  
AC Surge  
Protector  
AC Surge  
Protector  
MM  
(INCHES)  
SPD1250-xxx SPD1250-xxx SPD1250-xxx SPD1250-xxx  
DIMENSIONS:  
Uc  
In  
Uc  
Uc  
Uc  
V
V
V
V
In  
In  
In  
Imax  
Up  
Imax  
Up  
Imax  
Up  
Imax  
Up  
C
Standards Compliance  
How To Order  
1250 - x S - xxx  
IEC61643-1 - International ................................ Class I, Class II  
EN 61643-11 - Europe....................................... Class I, Class II  
NF EN 61643-11 - France ................................. Class I, Class II  
UL1449 3rd Edition - USA.................... Type 4, Type 2 Location  
UL1449 3rd Edition - Canada............... Type 4, Type 2 Location  
CSA C22.2 No. 8-M1986............ Class 9091 32, Class 9091 92  
RoHS..............................................RoHS Directive 2002/95/EC  
Jan. 27, 2003 including annex and  
Series  
Configuration  
1 = One Protected Pole  
2 = Two Protected Poles  
3 = Three Protected Poles  
4 = Four Protected Poles  
Remote Signaling Code  
S = Remote Signaling  
RoHS Recast 2011/65/EU June 8, 2011  
Operating Voltage  
120 = 120/240 V, 120/208 V  
230 = 220/380 V, 240/415 V  
400 = 220/380 V, 277/480 V, 347/600 V  
480 = 347/600 V, 480 V  
Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116  
Europe: Tel: +41-41 768 5555 • Fax: +41-41 768 5510  
The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700  
www.bourns.com  
REV. 05/13  
Specifications are subject to change without notice.  
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.  
Users should verify actual device performance in their specific applications.  

相关型号:

1250-1S-230

General Duty AC Surge Protective Device
BOURNS

1250-1S-400

General Duty AC Surge Protective Device
BOURNS

1250-1S-480

General Duty AC Surge Protective Device
BOURNS

1250-2S-120

General Duty AC Surge Protective Device
BOURNS

1250-2S-230

General Duty AC Surge Protective Device
BOURNS

1250-2S-400

General Duty AC Surge Protective Device
BOURNS

1250-2S-480

General Duty AC Surge Protective Device
BOURNS

1250-3S-120

General Duty AC Surge Protective Device
BOURNS

1250-3S-230

General Duty AC Surge Protective Device
BOURNS

1250-3S-400

General Duty AC Surge Protective Device
BOURNS

1250-3S-480

General Duty AC Surge Protective Device
BOURNS

1250-4S-120

General Duty AC Surge Protective Device
BOURNS