Features  
Applications  
Telecommunications  
Industrial electronics  
Avionics  
Fast acting  
Balanced  
Stable breakdown throughout life  
Designed to operate with TBU® devices  
RoHS compliant* versions available  
2020 T Series - 3-Pole Fast Gas Discharge Tube  
Characteristics  
Characteristic  
Model No.  
2020-23T  
2020-15T  
2020-42T  
Minimum DC Sparkover (100 V/s)  
Throughout Service Life  
60 V  
180 V  
360 V  
Maximum Impulse Sparkover (5k V 1.2/50 µs)  
Throughout Service Life  
500 V  
650 V  
850 V  
Impulse Transverse Delay...................1000 V/µs ............................................................................... < 75 ns  
9
Insulation Resistance (IR)...................50 V / 100 V............................................................................ > 10  
Glow Voltage ......................................10 mA..................................................................................... ~ 70 V  
Arc Voltage .........................................>1 A........................................................................................ ~ 10 V  
Glow-Arc Transition Current............................................................................................................... < 0.5 A  
Capacitance .......................................1 MHz..................................................................................... < 1 pF  
DC Holdover Voltage (Network Applied per ITU-T K.12)  
Ω
2020-15T.......................................52 V ........................................................................................ < 150 ms  
2020-23T.......................................80 V ........................................................................................ < 150 ms  
2020-42T.......................................135 V ...................................................................................... < 150 ms  
1
Service Life .......................................8/20 µs, 5 kA .......................................................................... 1 operation  
2
2
10/1000 µs, 1 kV, 100 A.......................................................... 100 operations  
2/10 µs, 5 kV, 1000 A.............................................................. 10 operations  
10/700 µs, 6 kV, 150 A............................................................ 50 operations  
8/20 µs, 500 A, 1.2/50 µs, 500 V............................................ 150 operations  
600 V, 5 Arms, 0.2 sec............................................................ 10 operations  
2
2
3
600 Vrms, 0.5 A - 60 A ........................................................... Fail-Short activates  
230 Vrms, 0.5 A-25 A ............................................................. Fail-Short activates  
3
Operating and Storage Temperature.................................................................................................. -40 to +90 °C  
Climatic Category (IEC 60068-1) ....................................................................................................... 40 / 90 / 21  
Notes:  
1 Applied per conductor to center pin.  
2 Surge polarity should be reversed between consecutive surges (+,-,+,-)  
3 Applies only to GDT with optional Fail-Short. GDT operates and will survive with Fail-Short activation.  
• At delivery AQL 0.65 Level II, DIN ISO 2859.  
Applications  
Port Protection  
CanBus  
RS232  
RS422  
RS485  
RS485  
SDI  
VDSL  
GDT Device P/N  
2020-23T  
2020-23T  
2020-23T  
2020-23T  
2020-42T  
2020-23T  
2020-15T  
TBU® Device P/N  
TBU-CA065-100-WH  
TBU-CA065-200-WH  
TBU-CA065-200-WH  
TBU-CA065-200-WH  
TBU-CA085-200-WH  
TBU-CA065-100-WH  
TBU-CA050-500-WH  
“TBU” is a registered trademark of Bourns, Inc. in the U.S., Taiwan and European Community.  
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications.  
2020 T Series - 3-Pole Fast Gas Discharge Tube  
Product Dimensions (additional lead form configurations available upon request)  
2020-xxT-A  
2020-xxT-C4  
FAIL-SHORT  
CONFIGURATION  
2020-xxT-C2F SHOWN  
1.6  
7.8  
0.6  
8.1  
9.0  
7.5  
9.6  
1.0 DIA.  
11.7  
6.1  
6.1  
2020-xxT-A1  
7.9  
2020-xxT-C8  
11.2 REF.  
DIMENSIONS: MILLIMETERS  
UNITS WITH LEADS ARE BASED ON THE  
2020-xxT-A1 BODY.  
7.5  
1.0 DIA.  
How to Order  
0.7 - 1.0  
2020 - xxT - x x F LF  
1.0 DIA.  
2020-xxT-C2  
Model Number  
Designator  
13.0  
MAX.  
Voltage  
2020-xxT-C  
1.0 mm dia. lead wire  
15 = 60 V  
23 = 180 V  
42 = 360 V  
30  
LONG  
2 PLCS.  
15.4  
Leads  
A = None/Cassette Applications  
Cn = 1 mm Dia. Leads/Through-hole  
Lead Shape  
(See Product Dimension Drawings)  
1.0 DIA.  
4.4  
4.5  
Fail-Short Option  
4.4  
Blank = Standard Product  
F = With Fail-Short Mechanism  
1.0 DIA.  
RoHS Compliant Option  
Blank =Standard Product  
LF = RoHS Compliant Product  
7.5  
2020-xxT-C3  
Model 2020-xxT ships in standard bulk pack,  
100 pcs./tray.  
7.5  
1.0 DIA.  
4.75  
4.4  
4.75  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications.  
2020 T Series - 3-Pole Fast Gas Discharge Tube  
Switch-Grade Fail-Short Device Shorting Curve 2020-xxT-XF  
30.0  
20.0  
10.0  
5.0  
1.0  
0.5  
0.1  
1
10  
100  
1000  
Seconds  
ELTGS = Each Line to Ground Simultaneously  
NOTE: When using a GDT fail-short device, it is imperative that all components associated and  
connected to the GDT with failsafe be tested in their respective completely integrated environment  
(finished product) to assure desired operation.  
REV. C 04/11  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications.  

相关型号:

2020-15T-C2FFLF

Surge Protection Circuit, ROHS COMPLIANT PACKAGE-3
BOURNS

2020-15T-C2FLF

Fast Acting 3-Electrode Miniature GDT
BOURNS

2020-15T-C2LF

Surge Protection Circuit, ROHS COMPLIANT PACKAGE-3
BOURNS

2020-15T-C3

Fast Acting 3-Electrode Miniature GDT
BOURNS

2020-15T-C3F

Fast Acting 3-Electrode Miniature GDT
BOURNS

2020-15T-C3FLF

Fast Acting 3-Electrode Miniature GDT
BOURNS

2020-15T-C3LF

Fast Acting 3-Electrode Miniature GDT
BOURNS

2020-15T-C4

Fast Acting 3-Electrode Miniature GDT
BOURNS

2020-15T-C4F

Fast Acting 3-Electrode Miniature GDT
BOURNS

2020-15T-C4FLF

Surge Protection Circuit, ROHS COMPLIANT PACKAGE-3
BOURNS

2020-15T-C4LF

Surge Protection Circuit, ROHS COMPLIANT PACKAGE-3
BOURNS

2020-15T-C8F

Surge Protection Circuit, PACKAGE-3
BOURNS