2420-36-N [BOURNS]

Surge Protection Circuit, MODULE-5;
2420-36-N
型号: 2420-36-N
厂家: BOURNS ELECTRONIC SOLUTIONS    BOURNS ELECTRONIC SOLUTIONS
描述:

Surge Protection Circuit, MODULE-5

文件: 总2页 (文件大小:197K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Meets test requirements of Telcordia  
GR 974, GR1361, SBC SR 5165 and  
RUS PE-80  
Features  
Superior protection at a low price  
Balanced TRIGARD®  
Telcordia Analysis report DA-1547  
Patented Switch-Grade Fail-Short Device  
Quick response and high energy handling  
Low capacitance (<2.5 pF) - ideal for high-  
speed networks in high exposure  
environments  
U
C
®
L
US LISTED  
per UL 497 (File: 53117)  
Solid brass, gold-plated pins  
Test point access option  
Sealed option for harsh environments  
2420 Series - 5-Pin Gas Discharge Tube (GDT) Protector  
The Bourns® 3-type 2420 overvoltage protection modules utilize Bourns’ proprietary high-efficiency gas discharge tube with our  
patented Switch-Grade Fail-Short mechanism to provide robust and reliable surge and thermal overload protection at a very  
competitive price. The 2420 Series is based on Bourns’ three-terminal common chamber GDT. This design provides greatly  
improved and balanced turn-on characteristics for overvoltage protection. The GDT is UL approved for use without a back-up  
device. Air back-up devices can become contaminated; the circuitry of the 2420 eliminates this possibility. Our unique Switch-  
Grade Fail-Short device provides more reliable thermal overload protection compared to commonly used solder pellet or insulation  
burn-through designs.  
Bourns® 2420 Series 5-Pin protectors can be used universally for broadband voice and data circuits including ADSL, ADSL2+,VDSL,  
VDSL2 and high-speed Ethernet. The 2420 Series is an economical, reliable and low capacitance choice for overvoltage protection  
of copper pair circuits.  
Characteristics  
Test Methods per UL 497, CSA C22.2, Telcordia GR 974, 1361 and SBC SR 5165.  
DC Breakdown ............................................................................................................................................... 280-420 V  
AC Breakdown @ 60 Hz ................................................................................................................................. 280-420 V  
Impulse Breakdown  
100 V/µs .................................................................................................................................................... 625 V  
1000 V/µs .................................................................................................................................................. 875 V  
Insulation Resistance @ 100 Vdc ................................................................................................................... >1 GΩ  
Insertion Loss @ 100 MHz.............................................................................................................................. Exceeds Category 5  
Return Loss @ 100 MHz................................................................................................................................. Exceeds Category 5  
Capacitance Tip to Ring @ 1 MHz ................................................................................................................. <1.25 pF typical  
Capacitance Tip or Ring to Ground @ 1 MHz................................................................................................ <2.50 pF typical  
Impulse Reset 1  
52 V, 260 mA ............................................................................................................................................. <10 ms  
135 V, 200 mA ........................................................................................................................................... <10 ms  
150 V, 200 mA ........................................................................................................................................... <150 ms  
Impulse Life Characteristics (Tip and Ring to Ground Simultaneously)  
10 A, 10/1000 µs ....................................................................................................................................... >3000 operations  
100 A, 10/1000 µs ..................................................................................................................................... >300 operations  
300 A, 10/1000 µs ..................................................................................................................................... >100 operations  
500 A, 10/1000 µs ..................................................................................................................................... >400 operations2  
2,000 A, 10/250 µs .................................................................................................................................... >25 operations  
5,000 A, 20/100 µs .................................................................................................................................... >2 operations  
20,000 A, 8/20 µs ...................................................................................................................................... >1 operation  
AC Life Characteristics (Tip and Ring to Ground Simultaneously)  
0.5 A rms continuous ................................................................................................................................ >30 seconds  
1 A rms, 1 second, 600 ft. cable ............................................................................................................... >60 operations  
1 A rms, 1 second, 1 mile cable................................................................................................................ >60 operations  
10 A rms, 1 second ................................................................................................................................... >5 operations  
65 A rms, 11 cycles................................................................................................................................... >1 operation2  
120 A rms, 0.1 second .............................................................................................................................. 1 operation  
High Current Capability and Thermal Operation (Tip and Ring to Ground).................................................... >30 A rms, 15 min.  
Storage and Operating Temperature.............................................................................................................. -55 to +85 °C  
Telcordia analyzed for controlled (non-sealed) and uncontrolled, high-exposure (sealed) environments per GR 974 and SBC SR 5165.  
Telcordia Technical Analysis Report DA-1547.  
Notes:  
1
Network applied  
Per RUS PE-80  
2
Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications  
2420 Series - 5-Pin Gas Discharge Tube (GDT) Protector  
How To Order  
Schematic  
2420 - X XX - X - XX  
O.P.  
TIP  
EQUIPMENT  
TIP  
Model Number Designator  
Module Length  
3 = Standard: 52.37 mm (2.06 in.) 7 = Special Short: 41.19 mm (1.62 in.)  
GND  
Housing Color/Circuit Type  
1 = Black/Standard  
3 = Red/Special  
6 = Blue/Standard  
9 = Orange/Standard Service (non-Bridgelifter)  
10 = Yellow/Standard  
Pin Plating  
O.P.  
RING  
EQUIPMENT  
RING  
G = Gold Plated  
N = Tin Plated  
Special Options  
S = Sealed Case  
T = Test Points*  
ST = Sealed Case and Test Points*  
*T and ST options are not available on 2420-7x short module.  
Examples: 3B1E = 2420-31-G (black, no test points)  
3B3E = 2420-33-G (red, no test points)  
3C1E = 2420-31-G-T (black, with test points)  
3C3E = 2420-33-G-T (red, with test points)  
Product Dimensions  
2420-3 MODULE  
42.17  
(1.66)  
12.8  
(0.50)  
29.9  
(1.18)  
5.7  
(0.223)  
2.3  
(.092)  
2.2  
(.085)  
DIA.  
5 PLCS.  
DIA.  
2 PLCS.  
19.0  
(0.75)  
5.6  
(0.220)  
11.2  
(0.440)  
11.2  
(0.44)  
5.1  
(0.20)  
6.1  
(0.240)  
3.6  
(0.14)  
10.2  
(0.40)  
2420-7 MODULE  
30.99  
(1.22)  
MM  
(INCHES)  
DIMENSIONS:  
24.9  
(0.98)  
Asia-Pacific:  
Tel: +886-2 2562-4117  
Fax: +886-2 2562-4116  
6.15  
(0.24)  
Europe:  
Tel: +41-41 768 5555  
Fax: +41-41 768 5510  
The Americas:  
Tel: +1-951 781-5500  
Fax: +1-951 781-5700  
5.1  
(0.20)  
www.bourns.com  
10.2  
(0.40)  
REV. M 02/11  
“MSP” and “TRIGARD” are registered trademarks of Bourns, Inc.  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications  

相关型号:

2420-36-N-S

Surge Protection Circuit, MODULE-5
BOURNS

2420-36-N-ST

5-Pin Gas Discharge Tube (GDT) Protector
BOURNS

2420-36-N-T

5-Pin Gas Discharge Tube (GDT) Protector
BOURNS

2420-37-G-S

5-Pin Gas Discharge Tube (GDT) Protector
BOURNS

2420-37-G-ST

5-Pin Gas Discharge Tube (GDT) Protector
BOURNS

2420-37-G-T

5-Pin Gas Discharge Tube (GDT) Protector
BOURNS

2420-37-N-S

5-Pin Gas Discharge Tube (GDT) Protector
BOURNS

2420-37-N-ST

5-Pin Gas Discharge Tube (GDT) Protector
BOURNS

2420-37-N-T

5-Pin Gas Discharge Tube (GDT) Protector
BOURNS

2420-39-G

Surge Protection Circuit, MODULE-5
BOURNS

2420-39-G-S

Surge Protection Circuit, MODULE-5
BOURNS

2420-39-G-ST

Surge Protection Circuit, MODULE-5
BOURNS