MF-RX050/72 [BOURNS]
PTC Resettable Fuses;型号: | MF-RX050/72 |
厂家: | BOURNS ELECTRONIC SOLUTIONS |
描述: | PTC Resettable Fuses |
文件: | 总5页 (文件大小:459K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Features
Applications
■ 72 V rated
Almost anywhere there is a low voltage power
supply, up to 72 V and a load to be protected,
including:
■ Radial leaded devices
R
X
1
0
10
S
■ Cured, flame retardant epoxy polymer
insulating material meets UL 94 V-0
requirements
4
18
■ Security and fire alarm systems
■ Loudspeakers
■ RoHS compliant* and halogen free**
■ Agency recognition:
■ Power transformers
MF-RX/72 Series - PTC Resettable Fuses
Electrical Characteristics
1 Hour (R )
1
Tripped
Power
Initial
Max. Time
To Trip
I
I
Post-Trip
hold
trip
Resistance
Resistance
Dissipation
V max.
I max.
Amps
Model
Volts
Amperes
at 23 °C
Ohms
Ohms
Amperes Seconds
Watts
at 23 °C
at 23 °C
at 23 °C
at 23 °C
at 23 °C
Hold
Trip
0.40
0.50
0.60
0.80
1.00
1.30
1.50
1.80
2.20
2.70
3.20
3.70
5.00
6.00
7.50
Min.
Max.
2.84
1.95
1.36
0.86
0.77
0.48
0.40
0.31
0.25
0.19
0.14
0.12
0.08
0.06
0.05
Max.
4.40
3.00
2.10
1.29
1.17
0.72
0.60
0.47
0.38
0.30
0.22
0.19
0.13
0.10
0.08
Typ.
0.40
0.45
0.50
0.55
0.75
0.90
0.90
1.00
1.50
1.70
1.90
2.10
2.50
2.80
3.20
MF-RX020/72
MF-RX025/72
MF-RX030/72
MF-RX040/72
MF-RX050/72
MF-RX065/72
MF-RX075/72
MF-RX090/72
MF-RX110/72
MF-RX135/72
MF-RX160/72
MF-RX185/72
MF-RX250/72
MF-RX300/72
MF-RX375/72
72
72
72
72
72
72
72
72
72
72
72
72
72
72
72
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
0.20
0.25
0.30
0.40
0.50
0.65
0.75
0.90
1.10
1.35
1.60
1.85
2.50
3.00
3.75
1.50
1.00
0.76
0.52
0.41
0.27
0.18
0.14
0.15
0.12
0.09
0.08
0.05
0.04
0.03
1.0
1.25
1.5
2.2
2.5
3.0
2.0
3.9
2.5
4.0
3.25
3.75
4.5
5.3
6.3
7.2
5.5
8.2
6.75
8.0
9.6
11.4
12.6
15.6
19.8
24.0
9.25
12.5
15.0
18.75
Environmental Characteristics
Operating/Storage Temperature........................... -40 °C to +85 °C
Maximum Device Surface Temperature
in Tripped State .................................................. 125 °C
Passive Aging....................................................... +85 °C, 1000 hours............................................... 5 ꢀ typical resistance change
Humidity Aging...................................................... +85 °C, 85 ꢀ R.H. 1000 hours ............................. 5 ꢀ typical resistance change
Thermal Shock ..................................................... +85 °C to -55 °C, 10 times.................................... 10 ꢀ typical resistance change
Solvent Resistance............................................... MIL-STD-202, Method 215 ................................... No change
Vibration ............................................................... MIL-STD-883C, Method 2007.1,........................... No change
Condition A
Test Procedures And Requirements For Model MF-RX/72 Series
Test
Test Conditions
Accept/Reject Criteria
Visual/Mech.......................................................... Verify dimensions and materials........................... Per MF physical description
Resistance............................................................ In still air @ 23 °C................................................. Rmin ≤ R ≤ Rmax
Time to Trip........................................................... 5 times Ihold, Vmax, 23 °C ................................... T ≤ max. time to trip (seconds)
Hold Current......................................................... 30 min. at Ihold ..................................................... No trip
Trip Cycle Life....................................................... Vmax, Imax, 100 cycles........................................ No arcing or burning
Trip Endurance..................................................... Vmax, 48 hours..................................................... No arcing or burning
UL File Number .................................................... E174545
http://www.ul.com/ Follow link to Certifications, then UL File No., enter E174545
TÜV Certificate Number ....................................... R 02057213
http://www.tuvdotcom.com/ Follow link to “other certificates”, enter File No. 2057213
* RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
** Bourns follows the prevailing definition of “halogen free” in the industry. Bourns considers a product to be “halogen free” if (a) the Bromine (Br) content is 900 ppm or less;
(b) the Chlorine (Cl) content is 900 ppm or less; and (c) the total Bromine (Br) and Chlorine (Cl) content is 1500 ppm or less.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Additional Features
■ Resettable circuit protection
■ Bulk packaging, tape and reel and Ammo-Pak available on most models
MF-RX/72 Series - PTC Resettable Fuses
Product Dimensions
A
B
C
D
E
Physical Characteristics
Model
Max.
Max.
Nom.
5.1
Tol.
Min.
7.6
Max.
3.1
Style
1
Lead Dia.
0.51
Material
7.4
12.7
0.7
MF-RX020/72
MF-RX025/72
MF-RX030/72
MF-RX040/72
MF-RX050/72
MF-RX065/72
MF-RX075/72
MF-RX090/72
MF-RX110/72
MF-RX135/72
MF-RX160/72
MF-RX185/72
MF-RX250/72
MF-RX300/72
MF-RX375/72
Sn/CuFe
Sn/CuFe
Sn/CuFe
Sn/CuFe
Sn/Cu
(0.291)
7.4
(0.5)
(0.201)
5.1
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.020)
0.51
12.7
1
1
1
1
1
1
1
2
2
2
2
2
2
2
(0.291)
7.4
(0.5)
(0.201)
5.1
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.020)
0.51
13.4
(0.291)
7.4
(0.528)
13.7
(0.201)
5.1
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.020)
0.51
(0.291)
7.9
(0.539)
13.7
(0.201)
5.1
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.020)
0.51
(0.311
9.7
(0.539)
15.2
(0.201)
5.1
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.020)
0.51
Sn/Cu
(0.382)
10.4
(0.598)
16.0
(0.201)
5.1
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.020)
0.51
Sn/Cu
(0.409)
11.7
(0.630)
16.70
(0.657)
16.84
(0.662)
18.26
(0.718)
19.94
(0.785)
21.18
(0.833)
23.84
(0.938)
26.67
(1.050)
29.51
(1.161)
(0.201)
5.1
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.020)
0.51
Sn/Cu
(0.461)
10.84
(0.427)
12.26
(0.483)
13.94
(0.549)
15.18
(0.598)
17.84
(0.702)
20.67
(0.814)
23.51
(0.926)
(0.201)
5.1
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.020)
0.81
Sn/Cu
(0.201)
5.1
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.032)
0.81
Sn/Cu
(0.201)
5.1
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.032)
0.81
Sn/Cu
(0.201)
5.1
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.032)
0.81
Sn/Cu
(0.201)
10.2
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.032)
0.81
Sn/Cu
(0.402)
10.2
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.032)
0.81
Sn/Cu
(0.402)
10.2
(0.028)
0.7
(0.30)
7.6
(0.122)
3.1
(0.032)
0.81
Sn/Cu
(0.402)
(0.028)
(0.30)
(0.122)
(0.032)
Packaging options:
MM
(INCHES)
DIMENSIONS:
BULK:
500 pcs. per bag.
TAPE & REEL: MF-RX020/72-2 ~ MF-RX090/72-2 = 3000 pcs. per reel; MF-RX110/72-2 ~ MF-RX160/72-2 = 1500 pcs. per reel;
MF-RX185/72-2 - MF-RX375/72-2 = 1000 pcs. per reel.
AMMO-PACK: MF-RX020/72-AP ~ MF-RX090/72-AP = 2000 pcs. per pack; MF-RX110/72-AP ~ MF-RX160/72-AP = 1000 pcs. per pack;
MF-RX185/72-AP - MF-RX375/72-AP = 500 pcs. per pack.
How to Order
Typical Part Marking
Style 1
Style 2
Represents total content. Layout may vary.
MF - RX 110/72 - 2
A
E
A
E
®
Multifuse
MANUFACTURER'S
TRADEMARK
PART
Product Designator
Series
IDENTIFICATION
RX110
4180S
RX = Radial Leaded Component
LOT NO.
(S = CHINA)
DATE CODE
(FIRST DIGIT =
Hold Current, Ihold
B
B
020-375 (0.20 Amps - 3.75 Amps)
Maximum Voltage, Vmax
LAST DIGIT OF YEAR;
NEXT THREE DIGITS =
DAY OF YEAR)
72 (72 Volts)
Packaging Options
- 0 = Bulk Packaging
- 2 = Tape and Reel*
- AP = Ammo-Pak*
D
*Packaged per EIA 486-B
D
C
C
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
MF-RX/72 Series - PTC Resettable Fuses
Typical Time to Trip at 23 ˚C
1000
100
10
100
10
1
1
0.1
0.1
0.01
0.001
0.01
0.001
1
10
100
0.1
1
10
100
Fault Current (Amps)
Fault Current (Amps)
The Time to Trip curves represent typical performance of a device in a simulated application environment. Actual performance in specific customer applications
may differ from these values due to the influence of other variables.
Thermal Derating Chart - I
(Amps)
hold
Ambient Operating Temperature
Model
-40 °C
-20 °C
0.27
0.34
0.41
0.54
0.68
0.88
1.02
1.22
1.50
1.84
2.18
2.52
3.40
4.08
5.10
0 °C
0.24
0.30
0.36
0.48
0.60
0.77
0.89
1.07
1.31
1.61
1.90
2.20
2.98
3.57
4.46
23 °C
0.20
0.25
0.30
0.40
0.50
0.65
0.75
0.90
1.10
1.35
1.60
1.85
2.50
3.00
3.75
40 °C
0.16
0.20
0.24
0.32
0.41
0.53
0.61
0.73
0.89
1.09
1.30
1.50
2.03
2.43
3.04
50 °C
0.14
0.18
0.22
0.29
0.36
0.47
0.54
0.65
0.79
0.97
1.15
1.33
1.80
2.16
2.70
60 °C
0.13
0.16
0.19
0.25
0.32
0.41
0.47
0.57
0.69
0.85
1.01
1.17
1.58
1.89
2.36
70 °C
0.11
0.14
0.16
0.22
0.27
0.35
0.41
0.49
0.59
0.73
0.86
1.00
1.35
1.62
2.03
85 °C
0.08
0.10
0.12
0.16
0.20
0.26
0.30
0.36
0.44
0.54
0.64
0.74
1.00
1.20
1.50
MF-RX020/72
MF-RX025/72
MF-RX030/72
MF-RX040/72
MF-RX050/72
MF-RX065/72
MF-RX075/72
MF-RX090/72
MF-RX110/72
MF-RX135/72
MF-RX160/72
MF-RX185/72
MF-RX250/72
MF-RX300/72
MF-RX375/72
0.31
0.39
0.47
0.62
0.78
1.01
1.16
1.40
1.71
2.09
2.48
2.87
3.88
4.65
5.81
MF-RX/72 SERIES, REV. K, 10/15
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
MF-R, MF-R/90, MF-R/600, MF-RX, & MF-RX/72 Series
Tape and Reel Specifications
Devices taped using EIA468–B/IEC286-2 standards. See table below and Figures 1 and 2 for details.
IEC
EIA
Dimensions
Dimension Description
Carrier tape width
Mark
Mark
Dimensions
18
Tolerance
-0.5/+1.0
W
W
(.709)
11
(-0.02/+.039)
Hold down tape width
W
4
min.
W
0
(.433)
Hold down tape
No protrusion
3
Top distance between tape edges
Sprocket hole position
W
W
W
W
max.
2
1
0
6
5
0
(.118)
9
-0.5/+0.75
(-0.02/+0.03)
0.2
(.354)
4
Sprocket hole diameter
D
D
(.157)
18.5
( .0078)
3.0
Abscissa to plane (straight lead)
Abscissa to plane (kinked lead)
Abscissa to top (straight lead)
Abscissa to top (kinked lead)
Overall width w/lead protrusion (straight lead)
Overall width w/lead protrusion (kinked lead)
Overall width w/o lead protrusion (straight lead)
Overall width w/o lead protrusion (kinked lead)
Lead protrusion
H
H
(.728)
16
( .118)
0.5
H
H
H
H
H
H
C
C
C
C
0
1
1
0
1
1
1
1
2
2
1
(.63)
38.0
( .02)
max.
max.
max.
max.
max.
max.
max.
max.
(1.496)
32.2
(1.268)
55.0
(2.165)
43.2
(1.7)
54.0
(2.126)
42.5
(1.673)
1.0
I
L
1
(.039)
11
Protrusion of cutout
L
L
(.433)
Protrusion beyond hold-down tape
Sprocket hole pitch
I
I
Not specified
2
2
12.7
0.3
( .012)
1
P
P
0
0
(0.5)
Pitch tolerance
20 consecutive
( .039)
Device pitch: MF-R005–MF-R160, MF-R/90,
MF-RX110/72–MF-RX185/72
12.7
(0.5)
0.3
( .012)
Device pitch: MF-R185–MF-R400, MF-RX110–MF-RX375
MF-R/600, MF-RX250/72–MF-RX375/72
25.4
(1.0)
0.6
( .024)
0.9
Tape thickness
t
t
max.
max.
(.035)
Tape thickness with splice: MF-R010–MF-R160,
MF-RX110/72–MF-RX185/72
t
t
1.5
1
(.059)
Tape thickness with splice: MF-R250–MF-R1100,
2.3
1
max.
MF-RX110–MF-RX375, MF-R/90, MF-RX250/72-MF-RX375/72
(.091)
0.3
( .012)
1.0
Splice sprocket hole alignment
Body lateral deviation
0
0
0
Δ
Δ
Δ
h
h
( .039)
1.3
Body tape plane deviation
Δ
p
p
( .051)
MM
(INCHES)
DIMENSIONS:
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
MF-R, MF-R/90, MF-R/600, MF-RX, & MF-RX/72 Series
Tape and Reel Specifications
IEC
EIA
Dimensions
Dimension Description
Lead spacing: MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72
Mark
Mark
Dimensions
5.08
Tolerance
0.2
F
F
(0.2)
( 0.008)
56.0
Reel width
w
d
W
max.
2
(2.205)
370.0
(14.57)
4.75
Reel diameter
a
h
c
n
n
max.
3.25
( .128)
12.0
Space between flanges less device
Arbor hole diameter
W
f
1
(.187)
26.0
(1.024)
80
( .472)
Core diameter: MF-R, MF-RX, MF-R/90
Core diameter: MF-R/600
h
h
max.
max.
nom.
max.
max.
(3.15)
91
(3.58)
62
355
345
Box: MF-R, MF-RX, MF-R/90
(2.44) (14.0) (13.6)
64
372
362
Box: MF-R/600
(2.52) (14.6) (14.25)
3
Consecutive missing places: MF-R, MF-RX, MF-R/90
Consecutive missing places: MF-R/600
Empty places per reel: MF-R, MF-RX, MF-R/90
Empty places per reel: MF-R/600
none
Not specified
0.1 %
Taped Component Dimensions -
Figure 1
p
h
h
p
Reference plane
P1
H1
H1
F
H
H0
A
B
L
W1
W0
W
I2
P0
D0
I1
User direction of feed
Cross section A - B
Reel Dimensions - Figure 2
t
Reel
Upper side
Tape
h
f
User
direction
of
d
feed
Lower side
MM
(INCHES)
DIMENSIONS:
h
w
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
相关型号: