EXP-0911/02/S [BULGIN]

EXP Series EXPlora - Hazardous Area; EXP系列探险 - 危险区域
EXP-0911/02/S
型号: EXP-0911/02/S
厂家: ELEKTRON COMPONENTS LTD.    ELEKTRON COMPONENTS LTD.
描述:

EXP Series EXPlora - Hazardous Area
EXP系列探险 - 危险区域

文件: 总5页 (文件大小:3325K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
EXPLORA  
EXP Series EXPlora - Hazardous Area  
IP68  
Terminals  
Sealing Gasket  
O Ring  
Contact Insert  
O Ring  
O Ring  
O Ring  
Locking Ring  
Main Body  
Retaining  
Nut  
Panel Body  
Contact Insert  
Terminals  
Cable Gland  
Gland Cage  
Gland Nut  
ATEX approval for Zone 2 and Zone 22 applications  
Independently tested  
‘Scoop proof’ contacts  
Field termination - screw terminations  
Positive locating keyways - cannot be  
mis-connected  
ATEX Coding:  
II 3 GD  
ATEX Classification:  
Ex nA IIC T6 Gc  
Ex tc IIIC T85˚C Dc  
Sealing caps available to maintain IP68 rating of  
unmated connectors  
ATEX Certificate No:  
Baseefa09ATEX0232X  
Compact design  
IP68 rating tested at 1.054kg/sq cm (15lb/sq in)  
10m depth for 2 weeks  
Easy assembly - no special tools required  
Single or 3 phase applications  
Cost effective solution  
Up to 18A, 600V ac/dc rating  
2, 3, 4, 5, 7 and 10 pole  
Cable acceptance from 7 to 22mm O/D  
Leading earth contact for 3, 4, 5 & 7 pole versions  
Trailing Neutral on 5 pole  
Two cable connector versions for 15mm and 22mm  
(maximum) cable diameters  
Plug or socket connection in each body style  
Water and dustproof to IP68 when mated  
Separate strain relief on large cable version  
www.bulgin.co.uk  
1
EXPLORA  
EXP Series EXPlora - Hazardous Area Connector  
FLEX CABLE CONNECTOR  
Mates with in-line flex or  
panel mounting versions  
Positive, fast acting locking  
ring - can be turned with a  
gloved hand  
Plug or socket versions  
EXP-0 Series13-15mm cable  
dia. acceptance as standard,  
7-13mm with additional  
gland pack  
EXP-0911  
EXP-A Series 20-22mm cable  
dia. acceptance as standard,  
14-20mm with additional  
gland pack  
Strain Relief Clamp  
(EXP-A Series only)  
EXP-A911  
Flex Cable  
Standard Cable  
Large Cable  
Description  
Standard Cable  
Large Cable  
Description  
EXP-0911/02/P  
EXP-0911/03/P  
EXP-0911/04/P  
EXP-0911/05/P  
EXP-0911/07/P  
EXP-0911/10/P  
EXP-A911/02/P  
EXP-A911/03/P  
EXP-A911/04/P  
EXP-A911/05/P  
EXP-A911/07/P  
EXP-A911/10/P  
2 pole Plug  
3 pole Plug  
4 pole Plug  
5 pole Plug  
7 pole Plug  
10 pole Plug  
EXP-0911/02/S  
EXP-0911/03/S  
EXP-0911/04/S  
EXP-0911/05/S  
EXP-0911/07/S  
EXP-0911/10/S  
EXP-A911/02/S  
EXP-A911/03/S  
EXP-A911/04/S  
EXP-A911/05/S  
EXP-A911/07/S  
EXP-A911/10/S  
2 pole Socket  
3 pole Socket  
4 pole Socket  
5 pole Socket  
7 pole Socket  
10 pole Socket  
IN-LINE FLEX CABLE CONNECTOR  
Mates with either EXP-0911  
or EXP-A911 connectors  
Plug or socket versions  
EXP-0 Series13-15mm cable  
dia. acceptance as standard,  
7-13mm with additional  
gland pack  
EXP-A Series 20-22mm cable  
dia. acceptance as standard,  
14-20mm with additional  
gland pack  
Strain Relief Clamp  
(EXP-A Series only)  
EXP-0921  
EXP-A921  
In-Line Flex Cable  
Standard Cable  
Large Cable  
Description  
Standard Cable  
Large Cable  
Description  
EXP-0921/02/P  
EXP-0921/03/P  
EXP-0921/04/P  
EXP-0921/05/P  
EXP-0921/07/P  
EXP-0921/10/P  
EXP-A921/02/P  
EXP-A921/03/P  
EXP-A921/04/P  
EXP-A921/05/P  
EXP-A921/07/P  
EXP-A921/10/P  
2 pole Plug  
3 pole Plug  
4 pole Plug  
5 pole Plug  
7 pole Plug  
10 pole Plug  
EXP-0921/02/S  
EXP-0921/03/S  
EXP-0921/04/S  
EXP-0921/05/S  
EXP-0921/07/S  
EXP-0921/10/S  
EXP-A921/02/S  
EXP-A921/03/S  
EXP-A921/04/S  
EXP-A921/05/S  
EXP-A921/07/S  
EXP-A921/10/S  
2 pole Socket  
3 pole Socket  
4 pole Socket  
5 pole Socket  
7 pole Socket  
10 pole Socket  
www.bulgin.co.uk  
2
EXPLORA  
EXP Series EXPlora - Hazardous Area Connector  
PANEL MOUNTING CONNECTOR  
Mates with EXP-0911 and  
EXP-A911 connectors  
Single hole fixing  
Anti-rotation key  
High grade sealing gasket  
3-7mm panel thickness  
EXP-0931  
Panel Mounting  
EXP-0931/02/P  
EXP-0931/03/P  
EXP-0931/04/P  
EXP-0931/05/P  
EXP-0931/07/P  
EXP-0931/10/P  
2 pole Plug  
3 pole Plug  
4 pole Plug  
5 pole Plug  
7 pole Plug  
10 pole Plug  
EXP-0931/02/S  
EXP-0931/03/S  
EXP-0931/04/S  
EXP-0931/05/S  
EXP-0931/07/S  
EXP-0931/10/S  
2 pole Socket  
3 pole Socket  
4 pole Socket  
5 pole Socket  
7 pole Socket  
10 pole Socket  
FLANGE MOUNTING CONNECTOR  
Mates with EXP-0911 and  
EXP-A911 connectors  
Supplied with high grade  
sealing gasket  
Supplied with sealing  
grommets for panel fixing  
screws (M6 thread  
recommended)  
EXP-0941  
Flange Mounting  
EXP-0941/02/P  
EXP-0941/03/P  
EXP-0941/04/P  
EXP-0941/05/P  
EXP-0941/07/P  
EXP-0941/10/P  
2 pole Plug  
3 pole Plug  
4 pole Plug  
5 pole Plug  
7 pole Plug  
10 pole Plug  
EXP-0941/02/S  
EXP-0941/03/S  
EXP-0941/04/S  
EXP-0941/05/S  
EXP-0941/07/S  
EXP-0941/10/S  
2 pole Socket  
3 pole Socket  
4 pole Socket  
5 pole Socket  
7 pole Socket  
10 pole Socket  
www.bulgin.co.uk  
3
EXPLORA  
EXP Series EXPlora - Hazardous Area Connector  
Sealing Caps  
ACCESSORIES  
Heavy duty sealing caps to  
maintain IP68 rating of  
unmated connectors, with  
stainless steel straps  
EXP-0990  
Heavy duty sealing cap for use with  
EXP-0911/xx/x and EXP-A911/xx/x  
EXP-0991  
EXP-0992  
Heavy duty sealing cap for use with  
EXP-0921/xx/x and EXP-A921/xx/x  
Heavy duty sealing cap for use with  
EXP-0931 and EXP-0941  
Gland Packs  
EXP-0990, EXP-0991, EXP-0992  
EXP-0980  
Pack of 3 additional cable glands for  
EXP-0911 and EXP-0921 to suit cable sizes;  
11-13mm, 9-11 and 7-9mm dia.  
EXP-A980  
Pack of 3 additional cable glands for  
EXP-A911 and EXP-A921 to suit cable sizes;  
18-20mm, 16-18 and 14-16mm dia.  
PART NO SYSTEM  
EXP-09 x x / xx / x / x  
Series Designation  
09 = Standard Cable Accommodation (7-13mm)  
A9 = Large Cable Accommodation (14-22mm)  
Body Styles  
1 = Flex, 2 = Flex In-line,  
3 = Panel, 4 = Flange Panel  
Contact Termination  
1 = Screw Terminal  
Number Contacts  
02 = 2 pole, 03 = 3 pole, 04 = 4 pole,  
05 = 5 pole, 07 = 7 pole, 10 = 10 pole  
Contact Type  
P = Plug, S = Socket  
Cable Acceptance  
EXP-0 version:  
EXP-A version:  
Blank = 13-15mm Yellow cable gland (standard)  
Blank = 20-22mm Yellow cable gland (standard)  
3 = 11-13mm  
2 = 9-11mm  
1 = 7-9mm  
Black cable gland  
White cable gland  
Dark Grey cable gland  
9 = 18-20mm  
8 = 16-18mm  
7 = 14-16mm  
Black cable gland  
White cable gland  
Dark Grey cable gland  
Example:  
EXP-0911/07/P/3 = Flex cable connector with standard cable accommodation body, seven  
pin contacts, with gland to suit 11-13mm cable.  
www.bulgin.co.uk  
4
EXPLORA  
EXP Series EXPlora - Hazardous Area Connector  
SPECIFICATION  
Electrical:  
Mechanical:  
No Poles:  
2, 3, 4, 5  
18A  
7
10  
10A  
Sealing:  
IP68, EN60529:2001 tested @  
1.054kg/sq.cm. (15lb/sq.in.) 10m depth for  
2 weeks  
Current Rating:  
16A  
Voltage Rating:  
600Vac/dc  
430Vac/dc  
250Vac/dc  
Cable Acceptance:  
EXP-0911 - EXP-0921 13 - 15mm O/D standard,  
7-13mm with gland pack  
EXP-A911 - EXP-A921 20 - 22mm O/D standard,  
14 - 20mm with gland pack  
Contact Resistance:  
Insulation Resistance:  
Dielectric strength:  
AC Breakdown voltage:  
Ambient Temperature Range:  
Standards:  
<10m(initial)  
6
>10 M(@ 500V dc)  
2
Contact Accommodation:  
2.5 to 4mm (13 to10AWG) conductor,  
2.2kV ac min  
6kV  
single or multi stranded  
Termination:  
Axial screw terminals  
–20°C to +55°C  
Cable Retention force:  
22mm dia, 150N  
15mm dia, 150N  
7mm dia, 80N  
ATEX Zone 2 and Zone 22  
IEC60079-0:2007  
IEC60079-15:2005  
Gland Nut Torques:  
EXP-0 range  
ATEX Coding:  
II 3 GD  
13-15mm (Yellow - std.)  
11-13mm (black)  
9-11mm (white)  
7-9mm (dark grey)  
EXP-A range  
3.16Nm (28 lb/in)  
3.16Nm (28 lb/in)  
3.16Nm (28 lb/in)  
3.16Nm (28 lb/in)  
ATEX Certificate No:  
ATEX Classification:  
Baseefa09ATEX0232X  
Ex nA IIC T6 Gc  
Ex tc IIIC T85˚C Dc  
20-22mm (Yellow - std.)  
18-20mm (black)  
16-18mm (white)  
14-16mm (dark grey)  
3.16Nm (28 lb/in)  
3.16Nm (28 lb/in)  
3.16Nm (28 lb/in)  
3.16Nm (28 lb/in)  
Materials:  
Body Mouldings:  
Flammability Rating:  
UV Resistance:  
Contacts:  
Polyester  
Tightening Torques:  
Panel mount nut  
Flange & Bulkhead  
fixing screws  
UL94V-0  
2.25 Nm  
0.9 Nm  
To EN50021:1999  
Machined Solid Brass, Nickel plated  
O Rings:  
Nitrile  
Panel Sealing Gasket:  
Silicone Rubber  
Compliant  
Dimensions:  
Overall dimensions of connectors when mated together  
EXP-0911 + EXP-0921  
EXP-A911 + EXP-A921  
230 mm max.  
270 mm max.  
CONTACT LAYOUT  
EXP-0911 + EXP-0931  
EXP-A911 + EXP-A931  
135 mm max. (to panel)  
175 mm max. (to panel)  
EXP-0911 + EXP-0941  
EXP-A911 + EXP-A941  
145 mm max. (to panel, mid point on flange)  
174 mm max. (to panel, mid point on flange)  
2 pole  
5 pole  
3 pole  
7 pole  
4 pole  
10 pole  
www.bulgin.co.uk  
5

相关型号:

EXP-0911/03/P

EXP Series EXPlora - Hazardous Area
BULGIN

EXP-0911/03/S

EXP Series EXPlora - Hazardous Area
BULGIN

EXP-0911/04/P

EXP Series EXPlora - Hazardous Area
BULGIN

EXP-0911/04/S

EXP Series EXPlora - Hazardous Area
BULGIN

EXP-0911/05/P

EXP Series EXPlora - Hazardous Area
BULGIN

EXP-0911/05/S

EXP Series EXPlora - Hazardous Area
BULGIN

EXP-0911/07/P

EXP Series EXPlora - Hazardous Area
BULGIN

EXP-0911/07/S

EXP Series EXPlora - Hazardous Area
BULGIN

EXP-0911/10/P

EXP Series EXPlora - Hazardous Area
BULGIN

EXP-0911/10/S

EXP Series EXPlora - Hazardous Area
BULGIN

EXP-0931/02/P

EXP Series EXPlora - Hazardous Area
BULGIN

EXP-0931/02/S

EXP Series EXPlora - Hazardous Area
BULGIN