TPS_TXD2000 [CANDD]

AC/DC POWER SUPPLY; AC / DC电源
TPS_TXD2000
型号: TPS_TXD2000
厂家: C&D TECHNOLOGIES    C&D TECHNOLOGIES
描述:

AC/DC POWER SUPPLY
AC / DC电源

文件: 总4页 (文件大小:174K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Product Data Sheet  
2000 WATT  
AC/DC POWER SUPPLY  
TXD2000  
DESCRIPTION  
TheTXD2000 Series is a flexible, modular, 2000 Watt  
design offering two high current outputs in a 5 x 8 x 12  
package. Output voltages from 2.5 VDC through 48  
VDC are standard.With Power Factor Correction, EMI  
compliance to FCC and CISPR22, CE Mark and  
immunity to EN61000-4, theTXD2000 Series is ready  
for global deployment. Standard features include  
Remote Sense Compensation, Output Voltage  
Adjustment, Active Current Sharing, Remote Inhibit,  
Power Fa, DC OK Signal and Thermal  
Shal ORing diode is offered on  
voltage of 12 VDC or above.  
ement Model  
FEATURES  
zWide Range Input
High Range Input oa
z Harmonic Correction
or Replac  
y f  
or  
t
c
t F  
ntac  
o
C
z Active Current Sharin
z No Load Operation  
z Optional ORing Diode  
z 70-80% Efficiencies  
z FCC / CISPR 22 Class A EMI Filtering  
z Self-Cooled 5”x 8”x 12” Chassis  
z EN61000-4 Immunity  
AGENCY APPROVALS  
Internet: http://www.cdpowerelectronics.com  
Power Electronics Division, United States  
3400 E Britannia Drive,Tucson, Arizona 85706  
Phone: 800.547.2537 Fax: 520.770.9369  
Power Electronics Division, Europe  
C&D Technologies (Power Electronics) Ltd.  
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland  
Tel: +353.61.474.133  
Fax:+353.61.474.141  
Page 1  
TXD2000 2/2000 REV A  
Input Specifications  
Parameters  
Operating Range  
1000W  
Conditions  
Min  
Typ  
Max  
Units  
47-63Hz  
90  
264  
264  
80  
VAC  
VAC  
Apk  
Apk  
%
2000W  
47-63Hz  
180  
Inrush Current  
120VAC, 250C, cold start  
240VAC, 250C, cold start  
Nominal line, full load  
Full load  
160  
80  
Efficiency  
70  
20  
75  
Holdup  
msec  
Power Factor (1)  
Full load  
0.99  
Notes: (1) Harmonic currents meet EN61000-3-2  
Output Voltage Modules and Maximum Rated Load  
Output  
Voltage Code  
Output Voltage  
Output Current  
Output Power  
Voltage  
(Maximum Continuous) (Maximum Continuous)  
A
B
C
D
E
F
G
H
J
5.0  
12.0  
15.0  
18.0  
24.0  
28.0  
36.0  
48.0  
20.0  
3.3  
200A  
83A  
67A  
55A  
42A  
36A  
28A  
21A  
40A  
1000W  
1000W  
1000W  
1000W  
1000W  
1000
K
L
2.5  
ement Model  
or Replac  
y f  
or  
t
c
a
Output Specificatio
t F  
ntac  
o
C
Parameter  
Output Power  
90-264VAC  
180-264VAC  
C
Min  
Typ  
+5  
Max  
Units  
All and line conditions  
1000  
2000  
Watts  
Watts  
%
Limited by output module selection  
Voltage Adjustment Range Relative to nominal output voltage  
Output Regulation  
Minimum Load  
PARD  
Line, load or cross  
+0.2  
%
0
Amps  
Measured at output terminals, 20MHz  
00 to 500C  
50 mv or 1% pk-pk  
%/0C  
Temperature Coefficient  
+0.2  
Environmental Specifications  
Parameter  
Conditions  
Min  
Typ  
Max  
Units  
Ambient Temperature  
(Operating)  
Output de-rated linearly to 50% of  
rated capacity between 500C and 700C  
0
-50  
+70  
0C  
0C  
Ambient Temperature  
Altitude (Operating)  
Altitude (Non-operating)  
Shock  
Non-operating  
+85  
-200  
-200  
+10,000  
+50,000  
Feet  
Feet  
Per MIL-STD-810D, Method 516.3, Procedure II, in each axis, including NTSA drop test  
Per MIL-STD-810D, Method 514.3, Procedure II, in each axis, including NTSA drop test  
The TXD2000 is provided with internal cooling fans.  
Vibration  
Cooling  
Page 2  
TXD2000 2/2000 REV A  
Product Features  
Features  
Characteristic  
Remote Sense  
Active Current Sharing  
ORing Diode  
500mV compensation  
Single Wire; 5% current share if outputs are over 25% of rated load  
Optional (not available on modules below 12V)  
125% of nominal (+7.5%)  
OVP  
Thermal Shutdown  
DC OK Signal  
Power Fail Warning  
Remote Inhibit  
Automatic Restart  
Logic “1” when output is within +3% of nominal  
Transition to Logic “0” at least 5msec before loss of output regulation  
Logic “0” applied will inhibit output (referenced to –Sense terminal)  
Product Compliances  
Approval  
UL and cUL  
VDE  
Characteristic  
UL1950, 3rd Edition (1)  
EN60950  
FCC  
Class A requirements for conducted emissions  
Class A requirements for conducted emissions  
Electrostatic Discharge, Level 4  
Electrical Fast Transients, Level 3  
Input Surge Immunity, Level 3  
Harmonic Currents, Class A  
Low Voltage Directive  
CISPR 22  
EN61000-4-2  
EN61000-4-4  
EN61000-4-5  
EN61000-3-2  
CE Mark  
Notes: (1) UL1950, 3rd Edition incorporates the requirements of CSA 95
Ordering Information  
ement Model  
Model Designation  
F
L
L
H
BASE MODEL  
or Replac  
y f  
or  
t
c
Chassis: “8” = 5” x 8” x 12”; “
Output Voltage Module A: (see
a
t F  
ntac  
o
C
Output Voltage Module B: (see c
Standard Fan: “F”:  
Remote Inhibit - TTL Logic Level “0” turns the power supply OFF:  
Power Fail Warning - TTL Logic Level “0” indicates AC is LOST:  
ORing Diode - “D” indicates an ORing Diode is installed in each module; “N” = None:  
DC OK - TTL Logic Level “1” indicates DC is OK:  
OUTPUT VOLTAGES  
A = 5V  
G = 36V  
H = 48V  
J = 20V  
K = 3.3V  
L = 2.5V  
B = 12V  
C = 15V  
D = 18V  
E = 24V  
F = 28V  
The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes  
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice.  
No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&DTECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES  
product for use in life support devices/systems or in aircraft control applications.  
Page 3  
TXD2000 2/2000 REV A  
ement Model  
or Replac  
y f  
or  
t
c
a
t F  
ntac  
o
C

相关型号:

TPT-13-6003

Temperature Compensated Amplifier 6 GHz - 13 GHz
TELEDYNE

TPT-13-6004

Temperature Compensated Amplifier 6 GHz - 13 GHz
TELEDYNE

TPT-13-6005

Temperature Compensated Amplifier 6 GHz - 13 GHz
TELEDYNE

TPT-13-6006

Temperature Compensated Amplifier 6 GHz - 13 GHz
TELEDYNE

TPT-13-6014

Temperature Compensated Power Amplifier 6 GHz - 13 GHz
TELEDYNE

TPT-13-6015

Temperature Compensated Power Amplifier 6 GHz - 13 GHz
TELEDYNE

TPT-13-6016

Temperature Compensated Power Amplifier 6 GHz - 13 GHz
TELEDYNE

TPT-13-6026

Temperature Compensated Power Amplifier 6 GHz - 13 GHz
TELEDYNE

TPT-13-6036

Temperature Compensated Power Amplifier 6 GHz - 13 GHz
TELEDYNE

TPT-18-6004

Temperature Compensated Amplifier 6 GHz - 18 GHz
TELEDYNE

TPT-18-6005

Temperature Compensated Amplifier 6 GHz - 18 GHz
TELEDYNE

TPT-18-6006

Temperature Compensated Amplifier 6 GHz - 18 GHz
TELEDYNE