VKA100LS02 [CANDD]

100 WATT SINGLE OUTPUT HALF BRICK DC/DC CONVERTER; 100瓦单输出半砖DC / DC转换器
VKA100LS02
型号: VKA100LS02
厂家: C&D TECHNOLOGIES    C&D TECHNOLOGIES
描述:

100 WATT SINGLE OUTPUT HALF BRICK DC/DC CONVERTER
100瓦单输出半砖DC / DC转换器

转换器 输出元件
文件: 总4页 (文件大小:463K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Corporate: www.cdtechno.com  
Product: www.cdpowerelectronics.com  
VKA100xS  
100 Watt Single Output Half Brick DC/DC Converter  
Operation to +100°C Baseplate  
Temperature  
18-36V and 33 - 75V Input Range  
High Efficiency: 87% Typical at  
5V  
Primary Remote On/Off, Choice of  
Pos/Neg Logic  
100µS Transient Response 50-  
Adjustable Output Voltage  
Continuout Short-Circuit Protection  
Thermal Shutdown  
100%Load Step  
420 kHz Fixed-Frequency  
Operation  
Remote Sense  
Case Ground Pin  
The VKA100xS Series DC/DC  
converters present an economical  
and practical solution for distrib-  
uted power system architectures  
which require high power density  
and efficiency while maintaining  
system modularity and  
upgradeability. With the ability to and grounding configurations.  
operate over a wide input voltage  
range of 18 to 36 and 33 to 75  
volts, these modules are ideal for  
100% load steps in 100µSeconds  
use in battery backup applications to within 1% nominal Vout.  
common in todays' telecommuni- The patented fixed frequency  
cation and electronic data process- architecture combined with sur-  
ing applications. The output is  
fully isolated from the input,  
allowing for a variety of polarity  
face mount technology results in a  
compact, efficient and reliable  
solution to DC/DC conversion  
requirements. Safety Per UL1950,  
EN 60950 and CSA 22.2 #234  
The VKA100xS's proprietary  
control circuitry responds to 50-  
PRODUCT SELECTION CHART  
MODEL  
INPUT  
VOLTAGE  
VOUT  
(VDC)  
2.0V  
IOUT  
(A)  
EFFICIENCY  
MIN  
75  
73  
75  
80  
80  
85  
87  
88  
89  
76  
74  
77  
81  
81  
86  
88  
89  
89  
TYP  
76  
74  
76  
81  
81  
86  
88  
89  
90  
77  
75  
78  
82  
82  
87  
89  
90  
90  
VKA100LS02  
VKA100LS02F  
VKA100LS2V5F  
VKA100LS03  
VKA100LS03F  
VKA100LS05  
VKA100LS12  
VKA100LS15  
VKA100LS24  
VKA100MS02  
VKA100MS02F  
VKA100MS2V5F  
VKA100MS03  
VKA100MS03F  
VKA100MS05  
VKA100MS12  
VKA100MS15  
VKA100MS24  
20.0  
2.0V  
2.5V  
30.0  
30.0  
20.0  
30.0  
20.0  
8.3  
3.3V  
3.3V  
24VDC  
(18-36)  
5.0V  
12.0V  
15.0V  
24.0V  
2.0V  
6.7  
4.2  
20.0  
30.0  
30.0  
20.0  
30.0  
20.0  
8.3  
2.0V  
2.5V  
3.3V  
3.3V  
48VDC  
(33-75)  
5.0V  
12.0V  
15.0V  
24.0V  
6.7  
4.2  
SPECIFICATIONS, ALL MODELS  
Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified.  
PARAMETER  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
INPUT  
Voltage Range  
VKA100LS  
VKA100MS  
18  
33  
24  
48  
36  
75  
VDC  
VDC  
Maximum Input Current  
VKA100LS  
VIN = 16VDC  
VIN = 27VDC  
Peak - Peak  
DC to 1KHz  
7.4  
4.4  
A
A
mA  
dB  
mA  
VKA100MS  
Reflected Ripple Current  
Input Ripple Rejection  
No Load Input Current LS/MS  
Power Dissipation LS/MS  
No Load  
Standby, Primary On/Off  
Disabled LS/MS  
Inrush Charge  
20  
60  
50/100  
50  
3.6/4.8  
W
W
0.18/0.4  
VIN = VINmax.  
VKA100LS  
VKA100MS  
0.520  
0.360  
mC  
mC  
Quiescent Operating Current  
Primary On/Off Disabled  
8
12  
mA  
PARAMETER  
Rated Power  
Set point Accuracy  
Line Regulation  
Load Regulation  
Output Temperature Drift  
Output Ripple, p-p  
Output Current Limit Inception  
Output Short-Circuit Current (2)  
Output Overvoltage Limit  
Transient Response  
Peak Deviation  
CONDITIONS  
MIN  
0
TYP  
MAX  
100  
1
0.05  
0.05  
UNITS  
W
%
%
High Line to Low Line  
No Load to Rated Load  
0.02  
0.02  
.02  
%
%/°C  
VOUT, Nom  
lOUT, Nom  
lOUT, Nom  
V
DC to 20MHz BW  
test  
1%  
130%  
110%  
135%  
125%  
50 to 100% Load Step  
di/dt = 0.1A/µSec  
2%  
VOUT, Nom  
Settling Time  
VOUT, 1% of Nominal Output  
100  
µSec  
PARAMETER  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
ISOLATION  
Input to Output  
Peak Test for 2 Seconds  
1500  
1500  
500  
10  
VDC  
VDC  
VDC  
MΩ  
Input to Baseplate  
Output to Baseplate  
Resistance  
Capacitance  
Leakage Current  
GENERAL  
2000  
180  
pF  
µA, rms  
VISO = 240VAC, 60Hz  
Efficiency, Line, Load, Temp. (3)  
Switching Frequency  
Remote Sense Compensation  
Output Voltage Adjust Range  
Remote On/Off Control Inputs  
Primary  
400  
420  
440  
0.5  
KHz  
V
VOUT, Nom  
12 V & higher(4)  
-50% / +25%  
Open Collector/Drain  
Sink Current-Logic Low  
Vlow  
1.0  
0.4  
mA  
V
Vhigh0  
Turn-on Time  
Open Collector  
12.5  
Within 1% of Rated Output  
10.0  
mSec  
g (oz.)  
Weight  
85 (3.0)  
TEMPERATURE  
Operation/Specification  
Storage  
Shutdown Temperature  
Thermal Impedance, case-ambient  
Lead Solder Temperature  
Case Temperature  
Case Temperature  
Case Temperature  
-40  
-55  
+100  
+25  
+25  
+100  
+125  
+115  
°C  
°C  
°C  
°C/W  
°C  
7.1  
10 Seconds max  
+300  
NOTES: (1) See Typical Performance Curves, page 3  
(2) Continuous Mode  
(3) See graphs for Efficiency vs. Output Load, VIN, TCASE  
(4) 3.3V Models Limited in Trim Down Range  
(5) Consult Factory for Details  
Product: www.cdpowerelectronics.com  
2
VKA100xs Rev C 3/2001  
VKA100 xSzz -  
Device Family  
Indicates 100 Watt Regulated Unit  
Model Number  
Selected from Table of Electrical Characteristics  
Where:  
x = Input Voltage (L = 24VDC; M = 48VDC)  
zz = Output Voltage (03=3.3V, 05=5V, etc.)  
Lead Length  
0.200" - No Number  
0.145" - (6)  
0.110" - (8)  
Remote On-Off Logic:  
Positive - No Number  
Negative - (1)  
Product: www.cdpowerelectronics.com  
3
VKA100xs Rev C 3/2001  
MECHANICAL  
NOTES:  
All dimensions are in inches (millimeters).  
PIN PLACEMENT TOLERANCE: 0.005"  
MECHANICAL TOLERANCE: 0.015"  
Marked with: specific modeL ordered, date code, job code.  
0.530 MAX  
[13.46]  
0.20 [5.1]  
.040 [1.02] DIA.  
7 PLACES  
MATERIAL: Units are encapsulated in a low thermal  
resistancemoldingcompoundwhichhasexcellentchemical  
resistance and electrical properties in high humidity  
environmentsandoverawideoperatingtemperaturerange.  
The encapsulant and outer shell of the unit have UL94V-0  
ratings. Lead material is solder plated to allow ease of  
solderability.  
.081 [2.06] DIA.  
2 PLACES  
0.20 [5.1]  
0.50 [12.7]  
.400 [10.16]  
0.40 [10.16]  
2.000  
[50.80]  
0.700  
[17.78]  
1.000  
[25.40]  
1.000  
[25.40]  
2.40  
[61.0]  
MAX  
1.400  
1.400  
[35.56]  
[35.56]  
MOUNTING INSERTS M3 X 0.5 THRU, 4 PLACES  
MAX. TORQUE, 8 IN/LBS  
1.900  
0.19 [4.8]  
[48.26]  
2.28  
[57.91]  
MAX  
OUTPUT ADJUST VOLTAGE  
OVP NOTE  
Special attention should be given to the peak voltage  
deviation during a dynamic load step when trimming  
the output above the original set point to avoid  
tripping the overvoltage protection circuit. Should an  
OVP condition occur, the converter will go into a  
latch condition and must be externally reset before it  
will return to normal operation.  
This feature allows the user to accurately adjust the  
module's output voltage set point to a specified level.  
This is achieved by connecting a resistor or potentiometer  
from the TRIM terminal to either the +Vout terminal (for  
increased Vout) or the -Vout terminal (for decreased  
Vout). The formulae below describe the trim resistor  
value to obtain a Vout change of %. VO is output  
voltage prior to adjustment (3.3V, 5V, 12V, 15V, or 24V).  
Vo(100 + %)  
1.225%  
(100 + 2%)  
%  
_
Radj - up =  
k  
(
)
100  
%  
Radj - down =  
(
- 2  
)
kΩ  
C&D Technologies (Power Electronics) Ltd.  
Shannon, Co. Clare, Ireland  
Tel: +353.61.474.133 Fax:+353.61.474.141  
Power Electronics Division, United States  
3400 E Britannia Drive, Tucson, Arizona 85706  
Tel: 800.547.2537 Fax: 520.770.9369  
C&D Technologies, (NCL)  
Milton Keynes MK14 5BU UK  
Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545  
Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be  
accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or  
completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby  
disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from  
any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and in  
user’s specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications.  
Product: www.cdpowerelectronics.com  
4
VKA100xs Rev C 3/2001  

相关型号:

VKA100LS02-1

Analog IC
ETC

VKA100LS02-6

Analog IC
ETC

VKA100LS02-61

Analog IC
ETC

VKA100LS02-8

Analog IC
ETC

VKA100LS02-81

Analog IC
ETC

VKA100LS02C

100 Watt Adjustable Output DC/DC Converter
MURATA

VKA100LS02F

100 WATT SINGLE OUTPUT HALF BRICK DC/DC CONVERTER
CANDD

VKA100LS02F-1

Analog IC
ETC

VKA100LS02F-6

Analog IC
ETC
ETC

VKA100LS02F-8

Analog IC
ETC
ETC