CA18CAN12PA [CARLOGAVAZZI]

Proximity Sensors Capacitive Thermoplastic Polyester Housing;
CA18CAN12PA
型号: CA18CAN12PA
厂家: Carlo Gavazzi    Carlo Gavazzi
描述:

Proximity Sensors Capacitive Thermoplastic Polyester Housing

文件: 总5页 (文件大小:684K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Proximity Sensors Capacitive  
Thermoplastic Polyester Housing  
Types CA18CAN/CAF.....  
TM  
4TH Generation TRIPLESHIELD  
• Adjustable sensing distance: 2 - 10 mm Flush or  
3-15 mm Non-flush  
• Protection: short-circuit, transients and reverse polarity  
• Dust and humidity compensation  
• Dust or Temperature alarm output  
• Rated operational voltage: 10-40 VDC  
• Output: DC 200 mA, NPN or PNP  
• Standard Output: NO and NC  
• LED indications for Power-supply, Target and Stability  
• IP67, IP68, IP69K, Nema 1, 2, 4, 4X, 5, 6, 6P, 12  
• Cable and M12 connector versions available  
Product Description  
Ordering Key  
CA18CAN12NAM1  
Capacitive proximity switch  
Housing diameter (mm)  
Housing material  
The CA18CA.. capacitive indicated by the green and  
proximity switches feature yellow LEDs.  
an improved 4TH Genera- The sensing distance is  
tion TRIPLESHIELDTM tech- increased by 25 % allowing  
nology. Furthermore, these room for additional stable  
sensors feature increased detection.  
Housing length  
Detection principle  
Rated operating dist. (mm)  
Output type  
immunity to electromagnetic The Dust Alarm function  
interference (EMI), especial- gives an early warning that  
ly to frequency drives. Not the sensing surroundings  
only does 4TH Generation have to be cleaned.  
Output configuration  
Connection type  
TRIPLESHIELDTM  
feature The Temperature alarm func-  
an increased EMI, but it tion raises an alarm if the  
also increases the immuni- sensing surface goes beyond  
ty to humidity and dust. The 60 degree Celcius.  
implementation of stability The sensor housing is featur-  
indication eases the setup ing IP69K as well as approval  
procedure as both Stable ON by ECOLAB for cleaning-  
and Stable OFF positions are and disinfection agents.  
Type Selection  
Housing Sensor  
diameter type  
Output Output Connection Rated operating  
Ordering no.  
Standard  
Ordering no.  
Dust alarm  
Ordering no.  
Temperature alarm  
type  
function  
distance (Sn)  
M 18  
M 18  
M 18  
M 18  
M 18  
M 18  
M 18  
M 18  
M 18  
M 18  
M 18  
M 18  
Flush  
Flush  
Flush  
Flush  
Flush  
Flush  
Non-Flush NPN  
Non-Flush NPN  
Non-Flush PNP  
Non-Flush PNP  
Non-Flush PNP  
Non-Flush PNP  
NPN  
NPN  
PNP  
PNP  
PNP  
PNP  
NO+NC Cable  
NO+NC M12 Plug  
NO+NC Cable  
0 - 8 mm  
0 - 8 mm  
0 - 8 mm  
0 - 8 mm  
0 - 8 mm  
0 - 8 mm  
0 - 12 mm  
0 - 12 mm  
0 - 12 mm  
0 - 12 mm  
0 - 12 mm  
0 - 12 mm  
CA18CAF08NA  
CA18CAF08NAM1  
CA18CAF08PA  
NO+NC M12 Plug  
CA18CAF08PAM1  
NO  
NC  
Cable  
Cable  
CA18CAF08PODU1) CA18CAF08POTA1)  
CA18CAF08PCDU1) CA18CAF08PCTA1)  
NO+NC Cable  
NO+NC M12 Plug  
NO+NC Cable  
CA18CAN12NA  
CA18CAN12NAM1  
CA18CAN12PA  
NO+NC M12 Plug  
CA18CAN12PAM1  
NO  
NC  
Cable  
Cable  
CA18CAN12PODU2) CA18CAN12POTA2)  
CA18CAN12PCDU2) CA18CAN12PCTA2)  
1) Replaced by CA18CAF08BPA2IO  
2) Replaced by CA18CAN12BPA2IO  
Specifications EN 60947-5-2  
Rated operating distance (Sn)  
Non-flush mounted sensor  
Flush mounted sensor  
0 - 8 mm (factory setting  
8 mm - non-flush mounted)  
(ref. target 24x24 mm ST37,  
1 mm thick, grounded)  
0 - 12 mm (factory setting  
12 mm),  
(ref. target 36x36 mm ST37,  
1 mm thick, grounded)  
Specifications are subject to change without notice (10.12.2020)  
1
CA18CAN/CAF.....  
Specifications (cont.) EN 60947-5-2  
Sensitivity control  
Electrical adjustment  
Mechanical adjustment  
Adjustable distance  
Flush types  
Adjustable by potentiometer  
11 turns  
16 turns  
Connection  
Cable  
PVC,  
Ø5.2 x 2 m, 4 x 0.34 mm2  
Oil proof, grey  
M12 x 1 - 4 pin  
2 to 10 mm  
3 to 15 mm  
Plug (M1)  
Non-flush types  
Temperature alarm output  
Response time examples  
TA = 25°C  
60ºC 5ºC  
Effective operating dist. (Sr)  
Usable operating dist. (Su)*  
Repeat accuracy (R)  
Hysteresis (H)  
Rated operational volt. (UB)  
Ripple  
Output function  
Output switching function  
Rated operational current (Ie) ≤ 200 mA (continuous)  
Capacitive load  
No-load supply current (Io)  
Voltage drop (Ud)  
0.9 x Sn ≤ Sr ≤ 1.1 x Sn  
0.85 x Sr ≤ Su ≤ 1.15 x Sr  
14 sec @ TEXC = 800°C  
315 sec @ TEXC = 80°C  
≤ 5%  
TM  
TRIPLESHIELD  
3 - 20%  
Exceeding the norms for  
capacitive sensors  
Electrostatic discharge  
(EN61000-4-2)  
10 to 40 VDC (ripple incl.)  
≤ 10%  
NPN or PNP  
N.O. and N.C.  
Contact discharge  
Air discharge  
> 40 kV  
> 40 kV  
Electrical fast transients/burst  
(EN 61000-4-4)  
100 nF  
4kV  
≤ 12 mA  
Surge  
≤ 2.0 VDC @ 200 mA DC  
(EN 61000-4-5)  
Power-supply  
Sensor output  
> 2kV (with 500 Ω)  
> 2kV (with 500 Ω)  
Minimum operational  
current (Im)  
OFF state current (Ir)  
Protection  
≥ 0.5 mA  
≤ 100 μA  
Wire conducted disturbances  
(EN 61000-4-6)  
> 20 Vrms  
Short-circuit, reverse  
polarity, transients  
Power-frequency magnetic  
fields (EN 61000-4-8)  
Continous  
Frequency of operating  
cycles (f)  
Response time OFF-ON (ton)  
Response time ON-OFF (toff)  
Power ON delay (tv)  
Indication  
Target detected  
Power and detection stability LED, green  
> 60 A/m, 75.9 µ tesla  
> 600 A/m, 759 µ tesla  
50 Hz  
Short-time  
≤ 10 ms  
≤ 10 ms  
≤ 200 ms  
Radiated RF electromagnetic  
fields (EN 61000-4-3)  
> 20 V/m  
Shock (IEC 60068-2-27)  
30 G / 11ms, 3 pos, 3 neg  
per axis  
LED, yellow  
Rough handling shocks  
(IEC 60068-2-31)  
2 times from 1m  
100 times from 0,5m  
Environment  
Installation category  
Degree of pollution  
Degree of protection  
III (IEC 60664, 60664A;  
60947-1)  
Vibration (IEC 60068-2-6)  
10 to 150 Hz, 1 mm / 15 G  
Housing material  
Body  
3 (IEC 60664, 60664A;  
60947-1)  
IP 67, IP 68/60 min., IP69K**  
(IEC 60529; 60943-1)  
1, 2, 4, 4X, 5, 6, 6P, 12  
-30 to +85°C ( -22 to +185°F)  
PBT, grey,  
30% glass reinforced  
PA12, black  
PA12, black  
Nylon  
Cable gland  
Fingernuts  
Trimmershaft  
NEMA type  
Operating temperature  
Max. temperature on sensing face 120°C (248°F)  
Storage temperature  
Weight  
Cable version  
Plug version  
150 g  
75 g  
-40 to +85°C (-40 to +185°F)  
Rated insulation voltage  
1 kVAC (rms)  
IEC protection class III  
Approvals  
CE-marking  
MTTFd  
cULus (UL508), ECOLAB  
Yes  
Tightening torque  
≤ 2.6 Nm  
825 years @ 40°C (+104°F)  
* For Flush type sensor flush mounted in conductive material, the usable operating distance (Su) is 0.80 x Sr ≤ Su ≤ 1.2 x Sr for temperatures  
exceeding 0 - 60 °C ( 32 - 140°F)  
.
90°  
** The IP69K test according to DIN 40050-9 for high-pressure, high-temperature wash-down applications.  
The sensor must not only be dust tight (IP6X), but also able to withstand high-pressure and steam cleaning.  
The sensor is exposed to high pressure water from a spray nozzle that is fed with 80°C water at 8’000–  
10’000 KPa (80–100bar) and a flow rate of 14–6L/min. The nozzle is held 100 –150 mm from the sensor at  
angles of 0°, 30°, 60° and 90° for 30s each. The test device sits on a turntable that rotates with a speed of 5  
times per minute. The sensor must not suffer any damaging effects from the high pressure water in appear-  
ance and function.  
60°  
30°  
0°  
2
Specifications are subject to change without notice (10.12.2020)  
CA18CAN/CAF.....  
Adjustment Guide  
The environments in which all TRIPLESHIELDTM capac- perature stability to ensure Note:  
capacitive  
sensors  
are itive sensors a user-friendly high immunity to electromag- The sensors are factory set  
installed can often be unsta- sensitivity adjustment instead netic interference (EMI) and a (default) to nominal sensing  
ble as regards temperature, of a fixed sensing range. Like- minimum need for adjusting range Sn.Sn.  
humidity, object distance and wise, these sensors provide sensitivity, if the temperature  
industrial (noise) interference. an extended sensing range to varies.  
That is why Carlo Gavazzi accommodate mechanically  
offers as standard features in demanding areas and tem-  
Wiring Diagram  
NPN  
PNP Dust- or Temperature alarm on NC  
BN  
BN  
BK  
WH  
BK  
10 - 40 VDC  
200 mA  
10 - 40 VDC  
200 mA  
WH (DU/TA)  
BU  
BU  
PNP  
PNP Dust- or Temperature alarm on NO  
BN  
BN  
BK  
BK  
10 - 40 VDC  
200 mA  
10 - 40 VDC  
200 mA  
WH  
WH (DU/TA)  
BU  
BU  
Detection Diagram  
Sensor  
Flush  
Non-flush  
Y
X
Target  
Distance (inch)  
Distance (inch)  
-0,31 -0,24 -0,16 -0,08  
25  
0
0,08  
0,16  
0,24  
0,31  
0,39  
0,47  
0,55  
-0,31 -0,24 -0,16 -0,08  
25  
0
0,08  
0,16  
0,24  
0,31  
0,39  
0,47  
0,55  
0,98  
0,79  
0,98  
0,79  
20  
15  
10  
5
20  
15  
10  
5
0,59  
0,59  
0,39  
0,39  
0,20  
0,20  
0
0,00  
0
0,00  
-5  
-0,20  
-0,39  
-0,59  
-0,79  
-0,98  
-5  
-0,20  
-0,39  
-0,59  
-0,79  
-0,98  
-10  
-15  
-20  
-25  
-10  
-15  
-20  
-25  
-8  
-6  
-4  
-2  
0
2
4
6
8
10  
12  
14  
-8  
-6  
-4  
-2  
0
2
4
6
8
10  
12  
14  
Distance (mm)  
Distance (mm)  
Specifications are subject to change without notice (10.12.2020)  
3
CA18CAN/CAF.....  
Detection Stability Indication  
Target influence  
Stable ON  
Output ON  
Output OFF  
Stable OFF  
Time  
Green LED ON  
Yellow LED ON  
Output NO  
Output NC  
>1 sec.  
>1 sec.  
>1 sec.  
>1 sec.  
>1 sec.  
>1 sec.  
>2 sec.  
>2 sec.  
Dust alarm NO  
Dust alarm NC  
Dimensions  
CA18CAF....  
CA18CAF....M1  
86  
85  
70  
70  
LED  
LED  
M18 x 1.0 x 55  
15  
M12 x 1.0  
M18 x 1.0 x 55  
15  
CA18CAN....  
CA18CAN....M1  
86  
85  
70  
70  
LED  
LED  
8
M18 x 1.0 x 47  
15  
M12 x 1.0  
8
M18 x 1.0 x 47  
15  
Cable  
Plug  
The back of the sensor  
Colour code  
2
Sensitivity  
adjustment  
Green LED  
1 Brown  
2 White  
3 Blue  
Yellow LED  
3
1
4 Black  
4
4
Specifications are subject to change without notice (10.12.2020)  
CA18CAN/CAF.....  
Installation Hints  
Capacitive sensors have a  
unique ability to detect al-  
most any material in liquid or  
solid form. Capacitive sen-  
sors are able to detect me-  
tallic as well as non-metallic  
objects. However, their tradi-  
tional use is for non-metallic  
materials such as:  
Chemical Industry  
Cleansers, fertilizers, liq-  
uid soaps, corrosives and  
petrochemicals.  
Packaging Industry  
Package inspection for lev-  
el or contents, dry goods,  
fruits and vegetables, dairy  
products.  
The nominal sensing distan-  
ce for a capacitive sensor  
is referred to a grounded  
metal plate (ST37). For addi-  
tional information regarding  
dielectric ratings of materi-  
als please refer to Technical  
Information.  
Wood Industry  
Saw dust, paper products,  
door and window frames.  
Materials are detected due to  
their dielectric constant. The  
bigger the size of an object,  
the higher the density of ma-  
terial, the better or easier it is  
to detect the object.  
Ceramics & Glass  
Industry  
Raw materials, clay or  
finished products, bottles.  
Plastics Industry  
Resins, regrinds or mould-  
ed products.  
To avoid interference from inductive voltage/  
current peaks, separate the prox. switch pow-  
er cables from any other power cables, e.g.  
motor, contactor or solenoid cables  
Relief of cable strain  
Protection of the sensing face  
Switch mounted on mobile carrier  
Not correct  
Correct  
The cable should not be pulled  
Any repetitive flexing of the  
cable should be avoided  
A proximity switch should not serve as a  
mechanical stop  
Delivery Contents  
Accessories  
Connector type CONB14NF-... -series.  
Mounting Brackets AMB18-S.. (straight),  
AMB18-A.. (angled)  
Capacitive switch: CA18CAN/CAF.......  
• User manual  
• 2 x M18 fingernuts  
• Screwdriver  
• Packaging: Cardboard box  
Specifications are subject to change without notice (10.12.2020)  
5

相关型号:

CA18CAN12PAM1

Proximity Sensors Capacitive Thermoplastic Polyester Housing
CARLOGAVAZZI

CA18CLF08TC

Proximity Sensors Capacitive Thermoplastic Polyester Housing
CARLOGAVAZZI

CA18CLF08TCM6

Proximity Sensors Capacitive Thermoplastic Polyester Housing
CARLOGAVAZZI

CA18CLF08TO

Proximity Sensors Capacitive Thermoplastic Polyester Housing
CARLOGAVAZZI

CA18CLF08TOM6

Proximity Sensors Capacitive Thermoplastic Polyester Housing
CARLOGAVAZZI

CA18CLN12TC

Proximity Sensors Capacitive Thermoplastic Polyester Housing
CARLOGAVAZZI

CA18CLN12TCM6

Proximity Sensors Capacitive Thermoplastic Polyester Housing
CARLOGAVAZZI

CA18CLN12TO

Proximity Sensors Capacitive Thermoplastic Polyester Housing
CARLOGAVAZZI

CA18CLN12TOM6

Proximity Sensors Capacitive Thermoplastic Polyester Housing
CARLOGAVAZZI

CA18EAF08BPA2IO

Capacitive Proximity Sensors with IO-Link communication
CARLOGAVAZZI

CA18EAF08BPM1IO

Capacitive Proximity Sensors with IO-Link communication
CARLOGAVAZZI

CA18EAN12BPA2IO

Capacitive Proximity Sensors with IO-Link communication
CARLOGAVAZZI