CA30CAF16NA [CARLOGAVAZZI]
Proximity Sensors Capacitive Thermoplastic Polyester Housing;型号: | CA30CAF16NA |
厂家: | Carlo Gavazzi |
描述: | Proximity Sensors Capacitive Thermoplastic Polyester Housing |
文件: | 总5页 (文件大小:698K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Proximity Sensors Capacitive
Thermoplastic Polyester Housing
Types CA30CAN/CAF.....
• 4TH Generation TRIPLESHIELDTM
• Adjustable sensing distance: 2 - 20 mm flush or 4-30
mm non-flush
• Protection: short-circuit, transients and reverse polarity
• Dust and humidity compensation
• Dust or temperature alarm output
• Rated operational voltage: 10-40 VDC
• Output: DC 200 mA, NPN or PNP
• Standard Output: NO and NC
• LED indications for power-supply, output and stability
• IP67, IP68, IP69K, Nema 1, 2, 4, 4X, 5, 6, 6P, 12
• Cable and M12 connector versions available
Product Description
Ordering Key
CA30CAN25NAM1
Capacitive proximity switch
Housing diameter (mm)
Housing material
The CA30CA.. capacitive the green and yellow LEDs.
proximity switches feature an The sensing distance is
improved 4TH generation TRI- increased by 20 – 25 %
Housing length
PLESHIELDTM
technology. allowing room for additional
Furthermore, these sensors stable detection.
Detection principle
Rated operating dist. (mm)
Output type
feature increased immunity The dust alarm function
to electromagnetic interfer- gives an early warning that
ence (EMI), especially to fre- the sensing surroundings
quency drives. Not only does have to be cleaned.
4TH generation TRIPLESH- The temperature alarm func-
IELDTM feature an increased tion raises an alarm if the
EMI, but it also increases sensing surface goes beyond
the immunity to humidity and 60 degree Celsius.
Output configuration
Connection type
dust. The implementation of The sensor housing is featur-
stability indication eases the ing IP69K as well as approval
setup procedure, as both by ECOLAB for cleaning and
Stable ON and Stable OFF disinfection agents.
positions are indicated by
Type Selection
Housing Sensor
diameter type
Output Output Connection Rated operating
Ordering no.
Standard
Ordering no.
Dust alarm
Ordering no.
Temperature alarm
type
function
distance (Sn)
M 30
M 30
M 30
M 30
M 30
M 30
M 30
M 30
M 30
M 30
M 30
M 30
M 30
Flush
Flush
Flush
Flush
Flush
Flush
Flush
Non-Flush NPN
Non-Flush NPN
Non-Flush PNP
Non-Flush PNP
Non-Flush PNP
Non-Flush PNP
NPN
NPN
PNP
PNP
PNP
PNP
PNP
NO+NC Cable
NO+NC M12 Plug
NO+NC Cable
0 - 16 mm
0 - 16 mm
0 - 16 mm
0 - 16 mm
0 - 16 mm
0 - 16 mm
0 - 16 mm
0 - 25 mm
0 - 25 mm
0 - 25 mm
0 - 25 mm
0 - 25 mm
0 - 25 mm
CA30CAF16NA
CA30CAF16NAM1
CA30CAF16PA
NO+NC M12 Plug
CA30CAF16PAM1
NO
NC
NC
Cable
Cable
M12 Plug
CA30CAF16PODU1) CA30CAF16POTA1)
CA30CAF16PCDU1) CA30CAF16PCTA1)
CA30CAF16PCM1DU2)
NO+NC Cable
NO+NC M12 Plug
NO+NC Cable
CA30CAN25NA
CA30CAN25NAM1
CA30CAN25PA
NO+NC M12 Plug
CA30CAN25PAM1
NO
NC
Cable
Cable
CA30CAN25PODU3) CA30CAN25POTA3)
CA30CAN25PCDU3) CA30CAN25PCTA3)
1) Replaced by CA30CAF16BPA2IO
2) Replaced by CA30CAF16BPM1IO
3) Replaced by CA30CAN25BPA2IO
Specifications EN 60947-5-2
Rated operating distance (Sn)
Non-flush mounted sensor
Flush mounted sensor
0 - 16 mm (factory setting
16 mm - non-flush mounted)
(ref. target 48x48 mm ST37,
1 mm thick, grounded)
0 - 25 mm (factory setting
25 mm),
(ref. target 75x75 mm ST37,
1 mm thick, grounded)
Specifications are subject to change without notice (10.12.2020)
1
CA30CAN/CAF.....
Specifications (cont.) EN 60947-5-2
Sensitivity control
Electrical adjustment
Mechanical adjustment
Adjustable distance
Flush types
Adjustable by potentiometer
11 turns
16 turns
Connection
Cable
PVC,
Ø5.2 x 2 m, 4 x 0.34 mm2
Oil proof, grey
M12 x 1 - 4 pin
2 to 20 mm
4 to 30 mm
Plug (M1)
Non-flush types
Temperature alarm output
Response time examples
TA = 25°C
60ºC 5ºC
Effective operating dist. (Sr)
Usable operating dist. (Su)
Repeat accuracy (R)
Hysteresis (H)
Rated operational volt. (UB)
Ripple
Output function
Output switching function
Rated operational current (Ie) ≤ 200 mA (continuous)
Capacitive load
No-load supply current (Io)
Voltage drop (Ud)
Minimum operational
current (Im)
OFF state current (Ir)
Protection
0.9 x Sn ≤ Sr ≤ 1.1 x Sn
16 sec @ TEXC = 800°C
390 sec @ TEXC = 80°C
0.85 x Sr ≤ Su ≤ 1.15 x Sr
≤ 5%
TM
TRIPLESHIELD
3 - 20%
Exceeding the norms for
capacitive sensors
Electrostatic discharge
(EN61000-4-2)
10 to 40 VDC (ripple incl.)
≤ 10%
NPN or PNP
N.O. and N.C.
Contact discharge
Air discharge
> 40 kV
> 40 kV
Electrical fast transients/burst
(EN 61000-4-4)
100 nF
4kV
≤ 12 mA
Surge
≤ 2.0 VDC @ 200 mA DC
(EN 61000-4-5)
Power-supply
Sensor output
> 2kV (with 500 Ω)
> 2kV (with 500 Ω)
≥ 0.5 mA
≤ 100 μA
Wire conducted disturbances
(EN 61000-4-6)
> 20 Vrms
Short-circuit, reverse
polarity, transients
Power-frequency magnetic
fields (EN 61000-4-8)
Continuous
Frequency of operating
cycles (f)
Response time OFF-ON (ton)
Response time ON-OFF (toff)
Power ON delay (tv)
Indication
Target detected
Power and detection stability LED, green
> 60 A/m, 75.9 µ tesla
> 600 A/m, 759 µ tesla
50 Hz
Short-time
≤ 10 ms
≤ 10 ms
≤ 200 ms
Radiated RF electromagnetic
fields (EN 61000-4-3)
> 20 V/m
Shock (IEC 60068-2-32)
30 G / 11ms, 3 pos, 3 neg
per axis
LED, yellow
Rough handling shocks
(IEC 60068-2-31)
twice from 1 m
100 times from 0.5 m
Environment
Installation category
Degree of pollution
Degree of protection
III (IEC 60664, 60664A;
60947-1)
Vibration (IEC 60068-2-6)
10 to 150 Hz, 1 mm / 15 G
Housing material
Body
3 (IEC 60664, 60664A;
60947-1)
IP 67, IP 68/60 min., IP69K*
(IEC 60529; 60943-1)
1, 2, 4, 4X, 5, 6, 6P, 12
-30 to +85°C ( -22 to +185°F)
PBT, grey,
30% glass reinforced
PA12, black
PA12, black
Nylon
Cable gland
Fingernuts
Trimmershaft
NEMA type
Operating temperature
Max. temperature on sensing face 120°C (248°F)
Storage temperature
Weight
Cable version
Plug version
190 g
106 g
-40 to +85°C (-40 to +185°F)
Rated insulation voltage
1 kVAC (rms)
IEC protection class III
Approvals
CE-marking
MTTFd
cULus (UL508), ECOLAB
Yes
Tightening torque
≤ 7.5 Nm
829 years @ 40°C (+104°F)
90°
60°
* The IP69K test according to DIN 40050-9 for high-pressure, high-temperature wash-down applications.
The sensor must not only be dust tight (IP6X), but also able to withstand high-pressure and steam cleaning.
The sensor is exposed to high-pressure water from a spray nozzle that is fed with 80°C water at 8’000–
10’000 KPa (80–100bar) and a flow rate of 14–6L/min. The nozzle is held 100 –150 mm from the sensor at
angles of 0°, 30°, 60° and 90° for 30s each. The test device sits on a turntable that rotates with a speed of 5
times per minute. The sensor must not suffer any damaging effects from the high pressure water in appear-
ance and function.
30°
0°
2
Specifications are subject to change without notice (10.12.2020)
CA30CAN/CAF.....
Adjustment Guide
The environments in which ard feature in all TRIPLESH- demanding areas and tem- Note:
capacitive
installed can often be unsta-
sensors
are IELD™ capacitive sensors, perature stability to ensure The sensors are factory set
a
user-friendly sensitivity high immunity to electromag- (default) to nominal sensing
ble as regards temperature, adjustment instead of a fixed netic interference (EMI) and a range Sn.
humidity, object distance sensing range. Likewise, minimum need for adjusting
and industrial (noise) inter- these sensors provide an sensitivity if the temperature
ference. This is why Carlo extended sensing range to varies.
Gavazzi offers, as a stand- accommodate mechanically
Wiring Diagram
NPN
PNP Dust- or Temperature alarm on NC
BN
BN
BK
WH
BK
10 - 40 VDC
200 mA
10 - 40 VDC
200 mA
WH (DU/TA)
BU
BU
PNP
PNP Dust- or Temperature alarm on NO
BN
BN
BK
BK
10 - 40 VDC
200 mA
10 - 40 VDC
200 mA
WH
WH (DU/TA)
BU
BU
Detection Diagram
Sensor
Flush
Non-flush
Y
X
Target
Distance (inch)
Distance (inch)
-0,59
25
-0,39
-0,20
0
0,20
0,39
0,59
0,79
0,98
1,18
-0,59
25
-0,39
-0,20
0
0,20
0,39
0,59
0,79
0,98
1,18
0,98
0,79
0,98
0,79
20
15
10
5
20
15
10
5
0,59
0,59
0,39
0,39
0,20
0,20
0
0,00
0
0,00
-5
-0,20
-0,39
-0,59
-0,79
-0,98
-5
-0,20
-0,39
-0,59
-0,79
-0,98
-10
-15
-20
-25
-10
-15
-20
-25
-15
-10
-5
0
5
10
15
20
25
30
-15
-10
-5
0
5
10
15
20
25
30
Distance (mm)
Distance (mm)
Specifications are subject to change without notice (10.12.2020)
3
CA30CAN/CAF.....
Detection Stability Indication
Target influence
Stable ON
Output ON
Output OFF
Stable OFF
Time
Green LED ON
Yellow LED ON
Output NO
Output NC
>1 sec.
>1 sec.
>1 sec.
>1 sec.
>1 sec.
>1 sec.
>2 sec.
>2 sec.
Dust alarm NO
Dust alarm NC
Dimensions
CA30CAF....
CA30CAF....M1
81
61
74
61
LED
LED
M12 x 1.0
M30 x 1.5 x 59.5
M30 x 1.5 x 59.5
CA30CAN....
CA30CAN....M1
81
61
74
61
LED
LED
14,5
M12 x 1.0
14,5
M30 x 1.5 x 45.5
M30 x 1.5 x 45.5
Cable
Plug
Back of sensor
Colour code
2
Sensitivity
adjustment
Green LED
1 Brown
2 White
3 Blue
Yellow LED
DIST.
3
1
OUTPUT
STABLE
4 Black
4
4
Specifications are subject to change without notice (10.12.2020)
CA30CAN/CAF.....
Installation Hints
Capacitive sensors have a
unique ability to detect al-
most any material in liquid or
solid form. Capacitive sen-
sors are able to detect me-
tallic as well as non-metallic
objects. However, their tradi-
tional use is for non-metallic
materials such as:
• Chemical Industry
Cleansers, fertilizers, liq-
uid soaps, corrosives and
petrochemicals.
• Packaging Industry
Package inspection for lev-
el or contents, dry goods,
fruits and vegetables, dairy
products.
The nominal sensing distan-
ce for a capacitive sensor
is referred to a grounded
metal plate (ST37). For addi-
tional information regarding
dielectric ratings of materi-
als please refer to Technical
Information.
• Wood Industry
Saw dust, paper products,
door and window frames.
Materials are detected due to
their dielectric constant. The
bigger the size of an object,
the higher the density of ma-
terial, the better or easier it is
to detect the object.
• Ceramics & Glass
Industry
Raw materials, clay or
finished products, bottles.
• Plastics Industry
Resins, regrinds or mould-
ed products.
To avoid interference from inductive voltage/
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
Not correct
Correct
The cable should not be pulled
Any repetitive flexing of the
cable should be avoided
A proximity switch should not serve as
mechanical stop
Delivery Contents
Accessories
• Connector type CONB14NF-... -series.
• Mounting Brackets AMB30-S.. (straight),
AMB30-A.. (angled)
• Capacitive switch: CA30CAN/CAF.......
• User manual
• 2 x M30 fingernuts
• Screwdriver
• Packaging: Cardboard box
Specifications are subject to change without notice (10.12.2020)
5
相关型号:
©2020 ICPDF网 联系我们和版权申明