CD34CNFLFPOP2 [CARLOGAVAZZI]
Capacitive sensor, Foreground Suppression;型号: | CD34CNFLFPOP2 |
厂家: | Carlo Gavazzi |
描述: | Capacitive sensor, Foreground Suppression |
文件: | 总9页 (文件大小:875K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CD34CNFLFxxx
Capacitive sensor, Foreground Suppression
Main features
• Compact housing
• Supply voltage: 10 to 30 VDC
• Output: 100 mA, NPN or PNP preset
• Make or break switching function
• LED indication for output and power ON
• Protection: reverse polarity, short circuit and transients
• Cable and pigtail M8 plug versions
• Excellent EMC performance
• IP65, IP66, IP67, IP68 and IP69K for hose-down
applications
• cULus
• Ecolab
Main functions
Description
• Detection of water-based fluids inside a container or tube
without direct contact with the fluids.
The CD34.. capacitive sensor is designed for
detecting water-based (conductive) liquids through
a non-metallic container wall, and it automatically
adapts to various thicknesses of plastic or glass
walls.
• Thesensordetectstheliquidsreliablywhilecompensating
for residue film, moisture or foam build-up from liquids
such as water, milk, body fluids (blood), acid- or alkaline
solutions with conductivity as high as 50 mS/cm inside or
outside the container wall.
• Flexible and fast universal mounting bracket.
• The sensing principle detects only the level of the liquids
while ignoring foam, film or build-up that would cause
standard capacitive sensors to detect faultily.
The universal mounting brackets allow the sensor
to be fixed on various tubes or containers.
Strong, compact housing with IP69K ratings and
ECOLAB approval for wash-down applications.
The sensor will function out of the box in most
applications, and teach-in capabilities are available
for adapting the sensor to more challenging
applications.
03/08/2020 CD34CNFLFxxx ENG
Carlo Gavazzi Industri A/S
1
CD34CNFLFxxx
References
Product selection key
CD34CNFLF
Enter the code option instead of
Code
C
D
34
C
N
Option
Description
Capacitive sensor
Rectangular housing
Length of housing
Plastic housing
Neutral
-
-
-
-
-
-
-
F
L
Flush mounting
Liquid level
F
Foreground suppression
NPN
PNP
N
P
O
N.O.
C
N.C.
P2
T5
2 m PVC Cable
Pigtail PVC
Type selection
Connec-
tion
Output
Code
NPN, N.O.
NPN, N.C.
PNP, N.O.
PNP, N.C.
NPN, N.O.
NPN, N.C.
PNP, N.O.
PNP, N.C.
CD34CNFLFNOP2
CD34CNFLFNCP2
CD34CNFLFPOP2
CD34CNFLFPCP2
CD34CNFLFNOT5
CD34CNFLFNCT5
CD34CNFLFPOT5
CD34CNFLFPCT5
ACD34-MB01
Cable
Pigtail
Mounting bracket
03/08/2020 CD34CNFLFxxx ENG
Carlo Gavazzi Industri A/S
2
CD34CNFLFxxx
Structure
A
B
E
A
E
B
E
D
C
C
Fig. 1 Cable
Fig. 2 Pigtail
Fig. 3 Sensing surface
Element
Component
LED
LED
Function
Green LED: Power ON
Yellow LED: Output
A
B
C
D
E
2 M3
Fixing holes for sensor mounting
Sensing surface
Recessed area for cable strips, max. 5 mm wide
Sensing
Accuracy
Factory settings
Manual teach
Pipes diameter
≤ 20% (-25°C... +80°C)
≤ 20% (-25°C... +60°C)
Min. Ø 8 mm
Temperature drift
Plastic 0.5 - 6 mm (non-conductive plastic wall)
Glass 0.5 - 4 mm (non-conductive glass wall)
Up to 10 mm plastic wall (best case)
Out of the box:
wall thickness
Detection
With manual setup:
wall thickness
Up to 10 mm glass wall (best case)
Water-based liquids such as water, milk, syrup, honey, milkshakes, lubricates, acids,
alkaline fluids, body fluids and other high-conductive liquids (up to 50 mS)
Detection liquids
03/08/2020 CD34CNFLFxxx ENG
Carlo Gavazzi Industri A/S
3
CD34CNFLFxxx
Features
Power Supply
Rated operational voltage (UB)
Ripple (Urpp
10 ... 30 VDC (ripple included)
≤ 10%
)
No load supply current (Io)
Power-ON delay (tv)
≤ 13 mA
< 300 ms
Outputs
Output functions
NPN or PNP by sensor type
Output switching function
Rated operational current (Ie)
OFF-state current(Ir) PNP and NPN
Voltage drop (Ud)
N.O. and N.C by sensor type
≤ 100 mA
50 μA
< 1 .5 V
Protection
Short circuit, reverse polarity and transients
Control of resistive loads and
solid-state loads with optical
isolation
DC-1
Utilization category
DC-13
330 nF
Control of electromagnets
Load capacitance max at (Ue)
Operation diagram
Tv = Power-ON delay
Power supply
Target
ON
Present
Break output
(N.C.)
Make output
(N.O.)
Tv
ON
ON
Tv
Response times
Operating frequency (f)
Response times
≤ 10 Hz
≤ 50 ms
≤ 50 ms
OFF-ON (tON)
ON-OFF (tOFF
)
03/08/2020 CD34CNFLFxxx ENG
Carlo Gavazzi Industri A/S
4
CD34CNFLFxxx
Indication
Normal mode
Green LED
OFF
Yellow LED
OFF
Power
OFF
ON
Output
OFF
OFF
ON
ON
ON
OFF
ON
ON
Output short circuit
Green LED
Yellow LED
Flashes 4Hz
Output
Yellow LED flashes minimum 1 sec.
OFF
Teach by wire
Out of the box (Factory settings):
Typically, the sensor can be used without any additional calibration; it is designed to work with plastic tank
walls of approximately 0,5 to 6 mm in thickness and glass walls of approximately 0,5 to 4 mm in thickness. It
is important that the glass or plastic is nonconductive.
Calibration:
If the factory settings are insufficient, the sensor is teachable to either Full or Empty.
Calibration Full:
The sensor switch point is set below the actual detection value to ensure that slight changes in the application
will not affect the sensing performance.
In most applications, the full calibration on a full tank or tube will be sufficient.
In critical applications with large variations in media type and temperature, it can be an advantage to teach the
Full level with approximately 50 % of the active sensing surface covered.
Full calibration procedure:
•Connect teach wire to V+ for 2 - 7 seconds
•The green LED flashes 1 imp. per sec. and the yellow LED is OFF
•After successful calibration, the yellow LED flashes 3 times (with 1 Hz)
Calibration Empty:
The sensor switch point is set above the actual detection value to ensure that slight changes in the application
will not affect the sensing performance.
In most applications, the Empty calibration on an empty tank or tube will be sufficient.
In critical applications with a high amount of residue film, moisture or foam build-up, an Empty calibration can
be performed with the build-up present.
Empty calibration procedure:
•Connect teach wire to V+ for 7 - 12 seconds
•The green LED flashes 1 imp. per sec. and the yellow LED is ON
•After successful calibration, the yellow LED flashes 3 times (with 1 Hz)
Cancel calibration procedure:
•Keep the teach wire connected to V+ for more than 14 seconds to abort teach procedure. The switch points
will remain unchanged.
•The green LED is off and the yellow LED flashes (4 Hz)
03/08/2020 CD34CNFLFxxx ENG
Carlo Gavazzi Industri A/S
5
CD34CNFLFxxx
Green LED
Flashes 1Hz
Flashes 1Hz
NA
Yellow LED
OFF
Output
Full calibration (2-7 sec)
Empty calibration (7-12 sec)
Succesful "full calibration"
Succesful "empty calibration"
ON
Flashes 3 times 1Hz
Flashes 3 times 1Hz
Flashes 10 times 4Hz
NA
NA
Unsuccesful calibration (cancelled or error) (>12 sec)
Environmental
-25°... +80°C (-13°... +176°F)
-40° ... +85°C (-40° ... +185°F)
Operating
Storage
Ambient temperature
35% ... 100%
35% ... 100%
Operating
Storage
Ambient humidity range
Vibration
Shock
Drop test
Rated insulation voltage (Ui)
Dielectric insulation voltage
Rated impulse withstand voltage
10 ...150 Hz, 1.0 mm/15 g
30 gnn / 11ms, 6 pos, 6 neg per axis
2 x 1 m and 100 x 0.5 m
75 VDC
≥ 1250 VAC rms
1 kV
EN 60068-2-6
EN60068-2-27
EN 60068-2-31
50/60 Hz for 1 min.
1.2/50 µs
ICE60664, ICE60664A,
EN60947-1
Pollution degree
3
Overvoltage category
Degree of protection
NEMA Enclosure Types
III
IEC60664; EN60947-1
IP65, IP66, IP67, IP68 @ 1.3m and 24 h IEC60539; EN60947-1
IP69K
1, 2, 4, 4x, 5, 12
DIN 40050-9
NEMA 250
EMC
± 8 kV @ air discharge or
± 4 kV @ contact discharge
Electrostatic discharge immunity test
IEC 61000-4-2, EN60947-1
Electromagnetic field immunity
Fast transient immunity
Wire-conducted noise
3 V/m
2 kV
3 V
IEC 61000-4-3, EN60947-1
IEC 61000-4-4, EN60947-1
IEC 61000-4-6, EN60947-1
Power frequency magnetic field im-
munity test
30 A/m
IEC 61000-4-8, EN60947-1
03/08/2020 CD34CNFLFxxx ENG
Carlo Gavazzi Industri A/S
6
CD34CNFLFxxx
Mechanics/electronics
Connection
Cable
Pigtail
2 m, 4-wire 4 x 0.14 mm2, Ø = 3.4 mm, PVC
0.3 m, M8, 4-pin, male
Wiring
+
+
-
1BN
2WH
1BN
4BK
ILOAD<100mA
ILOAD<100mA
4BK
2WH
3BU
-
3BU
Fig. 4 PNP NO
Fig. 5 NPN NO
+
+
1BN
1BN
2WH
4BK
ILOAD<100mA
ILOAD<100mA
4BK
2WH
-
-
3BU
3BU
Fig. 6 PNP NC
Fig. 7 NPN NC
NOTE: White wire connected to GND (3BU) wire when not in use
BN
Brown
WH
White
BK
Black
BU
Blue
Housing
Body
PC/PBT
Mounting bracket
Light guides
Pigtail
PC/PBT
Polyamid TR55, Transparent
Black TPU (Thermoplastic polyurethane), Stainless steel AISI 304
Dimensions
8 x 16 x 34 mm
≤ 60 g
≤ 30 g
Cable version
Pigtail version
Weight
Tightening torque, Sensor
Tightening torque, Mounting bracket
Screw size
0.2 Nm
0.2 Nm
M3 (with lowered head)
03/08/2020 CD34CNFLFxxx ENG
Carlo Gavazzi Industri A/S
7
CD34CNFLFxxx
Dimensions (mm)
16
8
10
3
6.6
3.2
Fig. 8 CD34
26
7.6
Fig. 9 Mounting bracket (ACD34-MB01)
03/08/2020 CD34CNFLFxxx ENG
Carlo Gavazzi Industri A/S
8
CD34CNFLFxxx
Compatibility and conformity
Approvals and markings
General reference
MTTFd
Sensor designed according to EN60947-5-2 and EN60947-1
246 years @ 40°C (+104°F)
EN ISO 13849-1, SN 29500
CE-marking
Approvals
(UL508 + C22.2)
Topax 56, Topaz AC1, Topaz
MD3, Topaz CL1, Topactiv OKTO,
P3-hypochloran
Other Approvals
Delivery contents and accessories
Delivery contents
• Capacitive sensor: CD34CNFLF…
• Mounting bracket: ACD34-MB01
• 2 x Foam pads 3 mm (for pipe mounting)
• 2 x Adhesive pads 1 mm (for screwless surface mounting)
• Quick installation guide
Further information
Information
Where to find it
QR
Manual
http://cga.pub/?262c4a
COPYRIGHT ©2020
Content subject to change. Download the PDF: www.gavazziautomation.com
03/08/2020 CD34CNFLFxxx ENG
Carlo Gavazzi Industri A/S
9
相关型号:
©2020 ICPDF网 联系我们和版权申明