IA18CLN08UCM1 [CARLOGAVAZZI]
Proximity Sensors Inductive Thermoplastic Polyester Housing;型号: | IA18CLN08UCM1 |
厂家: | Carlo Gavazzi |
描述: | Proximity Sensors Inductive Thermoplastic Polyester Housing |
文件: | 总3页 (文件大小:87K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Proximity Sensors Inductive
Thermoplastic Polyester Housing
Types IA, M12, M18 and M30, NAMUR
• Euronorm thermoplastic polyester housing,
cylindrical
• Short or long versions
• Diameter: M12, M18, M30
• Sensing distance: 2 to 15 mm
• Output: NAMUR EN 50 227
• Protection: Reverse polarity
• LED-indication
• 2 m cable or M12 plug
Product Description
Proximity switch in M12, M18 EN 60 947-5-2. For metal ver- Type
and M30 polyester housings. sions refer to type IA 12 E...
Made in accordance with Amplifier relay SD...... is avail- Housing type
euronorms EN 50 227 and able.
Ordering Key
IA 12 CSF 02 UC M1
Housing size
Sensing function
Sensing distance
Output type
Plug
Type Selection
Housing
diameter
Body
style
Connection
Rated operating
distance (Sn)
Ordering no.
NAMUR
M12
M12
M12
M12
M12
M12
M12
M12
Short
Short
Long
Long
Short
Short
Long
Long
Cable
Plug
Cable
Plug
Cable
Plug
Cable
Plug
2 mm 1)
2 mm 1)
2 mm 1)
2 mm 1)
4 mm 2)
4 mm 2)
4 mm 2)
4 mm 2)
IA 12 CSF 02 UC
IA 12 CSF 02 UC M1
IA 12 CLF 02 UC
IA 12 CLF 02 UC M1
IA 12 CSN 04 UC
IA 12 CSN 04 UC M1
IA 12 CLN 04 UC
IA 12 CLN 04 UC M1
M18
M18
M18
M18
M18
M18
M18
M18
Short
Short
Long
Long
Short
Short
Long
Long
Cable
Plug
Cable
Plug
Cable
Plug
Cable
Plug
5 mm 1)
5 mm 1)
5 mm 1)
5 mm 1)
8 mm2)
8 mm2)
8 mm2)
8 mm2)
IA 18 CSF 05 UC
IA 18 CSF 05 UC M1
IA 18 CLF 05 UC
IA 18 CLF 05 UC M1
IA 18 CSN 08 UC
IA 18 CSN 08 UC M1
IA 18 CLN 08 UC
IA 18 CLN 08 UC M1
M30
M30
M30
M30
M30
M30
M30
M30
Short
Short
Long
Long
Short
Short
Long
Long
Cable
Plug
Cable
Plug
Cable
Plug
Cable
Plug
10 mm 1)
10 mm 1)
10 mm 1)
10 mm 1)
15 mm 2)
15 mm 2)
15 mm 2)
15 mm 2)
IA 30 CSF 10 UC
IA 30 CSF 10 UC M1
IA 30 CLF 10 UC
IA 30 CLF 10 UC M1
IA 30 CSN 15 UC
IA 30 CSN 15 UC M1
IA 30 CLN 15 UC
IA 30 CLN 15 UC M1
1) For flush mounting in metal
2) For non-flush mounting in metal
Specifications are subject to change without notice (20.05.05)
1
IA 12, IA 18 and IA 30, NAMUR
Specifications
Rated operational volt. (Ue)
8.2 VDC
7 to 9 VDC
(6 to 35 VDC, all specifica-
tions not observed in
extended supply range)
Hysteresis (H)
(UB)
(Differential travel)
1 to 15% of sensing distance
0.9 x Sn ≤ Sr ≤ 1.1 x Sn
0.9 x Sr ≤ Su ≤ 1.1 x Sr
Effective operating dist. (Sr)
Usable operating dist. (S)
Ambient temperature
Operating
Self-inductance
Self-capacitance
≤ 500 µH
≤ 120 nF
-25° to +70°C (-13° to +158°F)
-30° to +80°C (-22° to +176°F)
Storage
No-load supply current (Io)
Activated: ≤1 mA
Not activated: ≥ 2.2 mA
Max. 9.35 mA
Degree of protection
Housing material
Body
Back
IP 67 (Nema 1, 3, 4, 6, 13)
Grey thermoplastic polyester
Black polyester
Protection
Transient voltage
EMC
Reverse polarity
≤ 1 kV/0.5 J
Approved according to
EN 50 080, EN 50 081
Connection
Cable
2 m, 2 x 0.5 mm2,
grey PVC, oil proof
M12 x 1
Plug
Power ON delay
Frequency of operating
cycles (f)
< 10 ms
Cables for plug (-1)
CONH1A serie
Weight (cable excluded)
IA 12xx
10 g
IA12xxF02 1.400 Hz
IA12xxN04 1.200 Hz
IA 18xxF05 18 g
IA 18xxN08 20 g
IA 30xxF10 50 g
IA 30xxN15 70 g
IA18xxF05
IA18xxN08 200 Hz
IA30xxF10 300 Hz
500 Hz
IA30xxN15 100 Hz
LED, yellow
Tightening torque
IA 12
IA 18
IA 30
1.8 Nm
2.6 Nm
7.5 Nm
Indication not activated
Assured operating dist. (Sa)
Repeat accuracy (R)
0 ≤ Sa ≤ 0.81 Sn
≤ 5%
Approvals
CE-marking
UL
Yes
Dimensions
Type
A
B
C
D
E
F
SW
Ø mm mm mm mm mm mm
IA 12 CSF 02 UC
M12 x 1 x 30
M12 x 1 x 50
M12 x 1 x 30
M12 x 1 x 50
M12 x 1 x 30
M12 x 1 x 50
M12 x 1 x 30
M12 x 1 x 50
10.7
10.7
10.7
10.7
10.7
10.7
10.7
10.7
30
50
30
50
34
54
34
54
11
11
5.0
5.0
8
8
8
8
8
8
8
8
17
17
17
17
17
17
17
17
IA 12 CLF 02 UC
IA 12 CSF 02 UC M1
IA 12 CLF 02 UC M1
IA 12 CSN 04 UC
IA 12 CLN 04 UC
IA 12 CSN 04 UC M1
IA 12 CLN 04 UC M1
12.6 11.9
12.6 11.9
11
11
12.6 11.9
12.6 11.9
5.0
5.0
IA 18 CSF 05 UC
M18 x 1 x 30
M18 x 1 x 50
M18 x 1 x 30
M18 x 1 x 50
M18 x 1 x 30
M18 x 1 x 50
M18 x 1 x 30
M18 x 1 x 50
16.7
16.7
16.7
16.7
16.7
16.7
16.7
16.7
30
50
30
50
38
58
38
58
11.6 15.4
11.6 15.4
13.1 11.9
13.1 11.9
11.6 15.4
11.6 15.4
13.1 11.9
13.1 11.9
8
8
8
8
8
8
8
8
24
24
24
24
24
24
24
24
IA 18 CLF 05 UC
IA 18 CSF 05 UC M1
IA 18 CLF 05 UC M1
IA 18 CSN 08 UC
IA 18 CLN 08 UC
IA 18 CSN 08 UC M1
IA 18 CLN 08 UC M1
IA 30 CSF 10 UC
M30 x 1.5 x 30
M30 x 1.5 x 50
M30 x 1.5 x 30
M30 x 1.5 x 50
M30 x 1.5 x 30
M30 x 1.5 x 50
M30 x 1.5 x 30
M30 x 1.5 x 50
28
28
28
28
28
28
28
28
30
50
30
50
42
62
42
62
13.6 15.4
13.6 15.4
13.6 11.9
13.6 11.9
13.6 15.4
13.6 15.4
13.6 11.9
13.6 11.9
10 36
10 36
10 36
10 36
10 36
10 36
10 36
10 36
IA 30 CLF 10 UC
IA 30 CSF 10 UC M1
IA 30 CLF 10 UC M1
IA 30 CSN 15 UC
IA 30 CLN 15 UC
IA 30 CSN 15 UC M1
IA 30 CLN 15 UC M1
2
Specifications are subject to change without notice (20.05.05)
IA 12, IA 18 and IA 30, NAMUR
Dimensions (cont.)
E
C
D
C
D
E
M12 x 1
F
F
LED
SW
A
A
LED
SW
Cable
Plug
Installation Hints
To avoid interference from inductive voltage/
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
Incorrect
Correct
The cable should not be pulled
Any repetitive flexing of the
cable should be avoided
A proximity switch should not serve as
mechanical stop
Wiring Diagram
NAMUR, Amplifier Relays
> SD 110/210.
> SD 170/270.
Refer to Technical information.
+
BN
1 K
R
8.2 V
BU
-
Specifications are subject to change without notice (20.05.05)