Proximity Inductive Sensors
Extended Range, Nickel-Plated Brass Housing
Types ICB, M30
• Sensing distance: 15 to 22 mm
• Flush or non-flush types
• Short or long body versions
• Rated operational voltage (Ub): 10 - 36 VDC
• Output: DC 200 mA, NPN or PNP
• Normally open or Normally closed
• LED indication for output ON, short-circuit and
overload
• Protection: reverse polarity, short circuit, transients
• Cable or M12 plug versions
• According to IEC 60947-5-2
• Laser engraved on front cap, permanently legible
• CSA certified for Hazardous Locations
Product Description
A family of inductive prox- Output is open collector Type
imity switches in industri- NPN or PNP transistors.
al standard nickel-plated
brass housings. They are
able to handle applications
where high sensing range is
requested.
Ordering Key
ICB30S30F15NOM1
Housing style
Housing material
Housing size
Housing length
Thread length
Detection principle
Sensing distance
Output type
Output configuration
Connection
Type Selection
Connec-
tion
Body
style
Rated
Ordering no.
NPN,
Normally open
Ordering no.
Ordering no.
NPN,
Normally closed
Ordering no.
PNP,
Normally closed
operating
distance Sn
PNP,
Normally open
Cable
Cable
Plug
Short
Short
Short
Short
Long
Long
Long
Long
15 mm 1)
22 mm 2)
15 mm 1)
22 mm 2)
15 mm 1)
22 mm 2)
15 mm 1)
22 mm 2)
ICB30S30F15NO
ICB30S30F15PO
ICB30S30F15NC
ICB30S30F15PC
ICB30S30N22NO
ICB30S30F15NOM1
ICB30S30N22NOM1
ICB30L50F15NO
ICB30S30N22PO
ICB30S30F15POM1
ICB30S30N22POM1
ICB30L50F15PO
ICB30S30N22NC
ICB30S30F15NCM1
ICB30S30N22NCM1
ICB30L50F15NC
ICB30S30N22PC
ICB30S30F15PCM1
ICB30S30N22PCM1
ICB30L50F15PC
Plug
Cable
Cable
Plug
ICB30L50N22NO
ICB30L50F15NOM1
ICB30L50N22NOM1
ICB30L50N22PO
ICB30L50F15POM1
ICB30L50N22POM1
ICB30L50N22NC
ICB30L50F15NCM1
ICB30L50N22NCM1
ICB30L50N22PC
ICB30L50F15PCM1
ICB30L50N22PCM1
Plug
1) For flush mounting in metal
2) For non-flush mounting in metal
Specifications
Rated operational voltage (Ub) 10 to 36 VDC (ripple incl.)
Indication for output ON
NO version
NC version
Activated LED, yellow
Target present
Target not present
Ripple
≤ 10%
Output current (Ie)
≤ 200 mA @ 50°C
(≤ 150 mA @ 50-70°C)
Indication for short circuit/
overload
Assured operating
sensing distance (Sa)
Effective operating
distance (Sr)
Usable operating distance (Su) 0.85 x Sr ≤ Su ≤ 1.1 x Sr
Repeat accuracy (R)
Differential travel (H)
(Hysteresis)
LED blinking (f = 2 Hz)
0 ≤ Sa ≤ 0.81 x Sn
OFF-state current (Ir)
No load supply current (Io)
Voltage drop (Ud)
Protection
≤ 50 μA
≤ 15 mA
Max. 2.5 VDC @ 200 mA
Reverse polarity,
short-circuit, transients
0.9 x Sn ≤ Sr ≤ 1.1 x Sn
Voltage transient
Power ON delay (tv)
Operating frequency (f)
1 kV/0.5 J
300 ms
≤ 5%
≤ 1000 Hz
1 to 20% of sensing dist.
Specifications are subject to change without notice (16.01.2017)
1
ICB, M30
Specifications (cont.)
Ambient temperature
Operating
Cable
Approvals (cont.)
cCSAus
As Process Control
Equipment for Hazardous
-25° to +70°C (-13° to +158°F)
Plug
Storage
-40° to +70°C (-40° to +158°F) Note: The terminal connector Locations.
-40° to +80°C (-40° to +176°F) (version ...M1) was not
- Class I, Division 2,
Groups A, B, C and D.
- T5 up to 150 mA, T4A for a
evaluated. The suitability of
Shock and vibration
Housing material
Body
IEC 60947-5-2/7.4
the terminal connector should
be determined in the end-use load current > 150 mA and
Nickel-plated brass
Grey thermoplastic polyester
application.
up to 200 mA, Enclosure
Type 4.
Front cap
Connection
Cable
Ambient temperature
Ta: -25° to +60°C.
Ø5.2 x 2 m, 3 x 0.34 mm2,
grey PVC, oil proof
M12 x 1
CCC is not required for
products with a maximum
operating voltage of ≤ 36 V
Plug
Degree of protection
IP 67
Weight (cable/nuts included)
ICB30 S
ICB30 L
EMC protection
IEC 61000-4-2 (ESD)
According to IEC 60947-5-2
8 KV air discharge,
4 KV contact discharge
Max. 185 g
Max. 195 g
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-6
IEC 61000-4-8
12 V/m
4 kV
10 V
Dimensions
Tightening torque
Approvals
See diagrams below
25 Nm
cULus
(UL508)
30 A/m
MTTFd
850 years @ 50°C (122°F)
Dimensions (mm)
71
59
LED
LED
30
10,6
12
30
10,6
Short body, flush version, cable
Short body, non-flush version, cable
67
55
1
2
4
3
1
2
4
3
LED (4 x 90°)
LED (4 x 90°)
12
30
9,8
30
9,8
Short body, flush version, plug
Short body, non-flush version, plug
79
91
LED
LED
10,6
10,6
50
12
50
Long body, flush version, cable
Long body, non-flush version, cable
2
Specifications are subject to change without notice (16.01.2017)
ICB, M30
Dimensions (mm) (cont.)
87
75
1
2
4
3
1
2
4
3
LED (4 x 90°)
LED (4 x 90°)
12
50
9,8
50
9,8
Long body, flush version, plug
Long body, non-flush version, plug
Installation
Flush sensor, when installed in damping material, must be
according to Picture 1A.
Non-flush sensor, when installed in damping material, must
be according to Picture 1B.
Picture 1A
Picture 1B
Free zone or
non-damping
material
Free zone or
non-damping
material
≥ 4 x d
≥ 3 x Sn
≥ 3 x Sn
d
d
Sn : nominal sensing distance
d : sensor diameter (30 mm)
Sn : nominal sensing distance
d : sensor diameter (30 mm)
Flush sensors, when installed together in damping material,
must be according to Picture 2A.
Non-flush sensors, when installed together in damping
material, must be according to Picture 2B.
Picture 2A
Picture 2B
d
d
d
d
4 x d
d
d : sensor diameter (30 mm)
d : sensor diameter (30 mm)
For sensors installed opposite each other, a minimum space
of 6 x Sn (the nominal sensing distance) must be observed
(See Picture 3).
Picture 3
≥ 6 x Sn
Sn : nominal sensing distance
Specifications are subject to change without notice (16.01.2017)
3
ICB, M30
Wiring Diagram
+
+
-
+
-
1 BN
+
-
1 BN
2 BK
3 BU
1 BN
2 BK
1 BN
4 BK
4 BK
3 BU
3 BU
3 BU
-
NPN - Normally open
NPN - Normally closed
PNP - Normally open
PNP - Normally closed
Reduction Factors
Accessories for Plug Versions
The rated operating distance The most important reduc-
is reduced by the use of tion factors for inductive
metals and alloys other than proximity sensors are shown
PVC
PUR
3-wire angled connector,
2 m cable
CONB13NF-A2 CONB13NF-A2P
CONB13NF-A5 CONB13NF-A5P
CONB13NF-A10 CONB13NF-A10P
CONB13NF-A15 CONB13NF-A15P
CONB13NF-S2 CONB13NF-S2P
CONB13NF-S5 CONB13NF-S5P
CONB13NF-S10 CONB13NF-S10P
CONB13NF-S15 CONB13NF-S15P
Fe360.
in Picture 4.
3-wire angled connector,
5 m cable
Picture 4
Fe360 : Steel
CrNi : Chrome-nickel
CuZn : Brass
Al : Aluminium
Cu : Copper
3-wire angled connector,
10 m cable
3-wire angled connector,
15 m cable
Sr : Effective operating distance
3-wire straight connector,
2 m cable
3-wire straight connector,
5 m cable
3-wire straight connector,
10 m cable
3-wire straight connector,
15 m cable
For any additional information
or different options,
please refer to the
“General Accessories -
Connector Cables -Type CONB1...”
datasheets.
Delivery Contents
• Inductive proximity switch ICB.
• 2 nuts NPB
• Packaging: plastic bag
4
Specifications are subject to change without notice (16.01.2017)
相关型号:
ICB30L50F15PCM1
Proximity Inductive Sensors Extended Range, Nickel-Plated Brass Housing
CARLOGAVAZZI
ICB30L50F15POM1
Proximity Inductive Sensors Extended Range, Nickel-Plated Brass Housing
CARLOGAVAZZI
©2020 ICPDF网 联系我们和版权申明