UA18CAD22NPTI [CARLOGAVAZZI]

Ultrasonic Diffuse, Digital Output Types UA18CAD......TI;
UA18CAD22NPTI
型号: UA18CAD22NPTI
厂家: Carlo Gavazzi    Carlo Gavazzi
描述:

Ultrasonic Diffuse, Digital Output Types UA18CAD......TI

文件: 总4页 (文件大小:474K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ultrasonic  
Diffuse, Digital Output  
Types UA18CAD......TI  
• Cylindrical M18 PBT housing  
• Sensing distance: 50-2200 mm  
• Power supply: 15 to 30 VDC  
• Outputs: Two multi function switching outputs.  
PNP or NPN  
• Setup: Normal switching or adjustable hysteresis  
• Repeatability 0.5%  
• Beam angle. ±±7 or ±87  
• Protection: Short-circuit, reverse polarity and  
overvoltage  
• Protection degree IP 6±  
• 2 m cable or M12 plug  
Product Description  
Ordering Key  
UA18CAD04NPM1TI  
A self-contained multi func-  
tion diffuse ultrasonic sensor  
with a sensing range of 50  
to 2200 mm in three ranges.  
2 switching outputs - easely  
set up for two different out-  
put modes and adjusted by  
teach-in - makes it ideal for  
level control tasks in a wide  
variety of vessels. A sturdy  
one-piece polyester housing Ultrasonic sensor  
provides the perfect pack- Housing style  
aging for the sophisticated Housing size  
microprocessor controlled Housing material  
and digitally filtered sensor Housing length  
electronics. Excellent EMC Detection principle  
performance and preci- Sensing distance  
sion are typical features of Output type  
this sensor on true distance Output configuration  
measurement.  
Connection  
Teach-in  
Type Selection  
Housing  
diameter  
Connec-  
tion  
Rated operating  
dist. (Sn)  
Digital output  
NPN/PNP  
Ordering no.  
M18  
M18  
M18  
M18  
M18  
M18  
M18  
M18  
M18  
M18  
M18  
M18  
Plug M12  
Cable  
Plug M12  
Cable  
Plug M12  
Cable  
Plug M12  
Cable  
Plug M12  
Cable  
Plug M12  
Cable  
50-400 mm  
50-400 mm  
50-400 mm  
50-400 mm  
100-900 mm  
100-900 mm  
100-900 mm  
100-900 mm  
200-2200 mm  
200-2200 mm  
200-2200 mm  
200-2200 mm  
2 x NPN  
2 x NPN  
2 x PNP  
2 x PNP  
2 x NPN  
2 x NPN  
2 x PNP  
2 x PNP  
2 x NPN  
2 x NPN  
2 x PNP  
2 x PNP  
UA 18 CAD 04 NP M1 TI  
UA 18 CAD 04 NP TI  
UA 18 CAD 04 PP M1 TI  
UA 18 CAD 04 PP TI  
UA 18 CAD 09 NP M1 TI  
UA 18 CAD 09 NP TI  
UA 18 CAD 09 PP M1 TI  
UA 18 CAD 09 PP TI  
UA 18 CAD 22 NP M1 TI  
UA 18 CAD 22 NP TI  
UA 18 CAD 22 PP M1 TI  
UA 18 CAD 22 PP TI  
Specifications  
Rated operating distance (Sn) Reference target: 1 mm  
metal rolled finish.  
Repeatability  
Beam angle  
UA18CAD04...  
UA18CAD09...  
UA18CAD22...  
0.5%  
CAD04: 100 x 100 mm  
CAD09 and CAD22:  
8ꢀ  
7ꢀ  
7ꢀ  
200 x 200 mm  
UA18CAD04  
UA18CAD09  
UA18CAD22  
50 - 400 mm  
100 - 900 mm  
200 - 2200 mm  
Adjustment  
Push-button  
P1 (farthest setpoint)  
P2 (nearest setpoint)  
Blind zone  
Temperature drift  
Temperature compensation Yes  
≤ 0.1%/ꢀC @ -20ꢀ to +60ꢀ C  
UA18CAD04...  
UA18CAD09...  
UA18CAD22...  
≤ 50 mm  
≤ 100 mm  
≤ 200 mm  
Specifications are subject to change without notice (04.01.2017)  
1
UA18CAD..  
Specifications (cont.)  
Hysteresis (H)  
Rated operational voltage (UB) 15 to 30 VDC  
Min. 1%  
Normal Switching function  
with N.O. output.  
Adjustable hysteresis  
Filling or emptying control  
(ripple included)  
Ripple (Urpp  
)
≤ 5%  
Indication Output ON  
Environment  
Installation category  
Yellow LED  
No-load supply current (Io)  
UA18CAD04...  
UA18CAD09...  
≤ 45 mA @ U max  
≤ 45 mA @ UB max  
≤ 50 mA @ UBB max  
lll (IEC 60664/60664A;  
60947-1)  
3 (IEC 60664/60664A;  
60947-1)  
UA18CAD22...  
Pollution degree  
Output current continuous (Ie)  
Max. load capacity 100 nF  
UL508 specification  
≤ 500 mA  
≤ 100 mA  
Degree of protection  
IP67 (IEC 60529; 60947-1)  
Ambient temperature  
Operating  
Storage  
Output current short-time (I)  
Max. load capacity 100 nF  
UL508 specification  
-20° to +60°C (-4° to +140°F)  
-35° to +70°C (-31° to +158°F)  
≤ 500 mA  
≤ 100 mA  
Vibration  
10 to 55 Hz, 1.0 mm/6g  
(IEC/EN 60068-2-6)  
Minimum operational  
current (Im)  
OFF-state current (Ir)  
Voltage drop (Ud)  
Protection  
≤ 0.5 mA  
Shock  
30 g / 11 mS, 3 directions  
(IEC/EN 60068-2-27)  
≤ 10 μA  
≤ 2.2 VDC @ Ie max.  
Rated insulation voltage  
Housing  
Material body  
< 500 VAC (rms)  
Short-circuit, overvoltage  
and reverse polarity  
PBT  
Carrier frequency  
UA18CAD04...  
UA18CAD09...  
UA18CAD22...  
Material front  
Epoxy-glass resin  
Grilamid  
Grilamid  
POM  
400 kHz  
300 kHz  
200 kHz  
Material back, plug  
Material back, cable  
Material push-button  
Sealing around push-button  
Material sealing front  
UA18CAD04...  
TPE  
Operating frequency (f)  
UA18CAD04...  
UA18CAD09...  
≤ 10 Hz  
≤ 4 Hz  
≤ 1 Hz  
TPE  
TPE  
PBT  
UA18CAD09...  
UA18CAD22...  
UA18CAD22...  
Response time OFF-ON (tON  
UA18CAD04...  
UA18CAD09...  
UA18CAD22...  
)
Connection  
Cable  
≤ 50 mS  
≤ 125 mS  
≤ 500 mS  
PVC, grey, 2 m,  
4 x 0.32 mm2, Ø = 4.7  
mm  
Plug  
Response time ON-OFF (tOFF  
UA18CAD04...  
UA18CAD09...  
UA18CAD22...  
)
M12, 4-pin (CON. 14-series)  
≤ 1 Nm  
≤ 50 mS  
≤ 125 mS  
≤ 500 mS  
Tightening torque  
Weight  
Cable version  
Plug version  
98 g  
35 g  
Power ON delay  
≤ 900 mS  
Output function, open  
collector  
By sensor type  
CE-marking  
Approvals  
Yes  
NPN or PNP  
cULus (UL508)  
Output switching function  
Two open collector transis-  
tor outputs to be config-  
ured as:.  
2
Specifications are subject to change without notice (04.01.2017)  
UA18CAD..  
Wiring Diagram  
Detection Range  
X
Target  
Y
Sensor  
BN1  
WH2  
BK4  
Distance (Inches)  
7,9 11,8  
0
3,9  
15,7  
19,7  
100,0  
80,0  
60,0  
3,9  
3,1  
PNP:  
Target 100 x 100 mm  
2,4  
BU3  
40,0  
20,0  
1,6  
0,8  
Target Ø 25 mm  
Digital  
0,0  
0,0  
-20,0  
-40,0  
-60,0  
-80,0  
-100,0  
-0,8  
-1,6  
-2,4  
-3,1  
-3,9  
BN1  
NPN:  
BK4  
WH2  
BU3  
0
100  
200  
300  
400  
500  
Distance (mm)  
UA 18 CAD 04 ...  
X
Target  
Y
Sensor  
Distance (Inches)  
Dimensions  
0,0  
7,9  
15,7  
23,6  
31,5  
39,4  
7,9  
200,0  
150,0  
100,0  
50,0  
5,9  
8.3  
Target 200 x 200 mm  
Target Ø 25 mm  
Teach  
3
3,9  
12.4  
3
2,0  
0,0  
0,0  
-2,0  
-3,9  
-5,9  
-7,9  
-50,0  
-100,0  
-150,0  
-200,0  
LED indication  
1÷2.5  
63.5  
17.6  
83.6÷85.1  
0
200  
400  
600  
800  
1.000  
Cable  
Distance (mm)  
UA 18 CAD 09 ...  
8.3  
Teach  
X
LED indication  
3
12.6  
Target  
Y
Sensor  
Distance (Feet)  
0,0  
1,2  
2,4  
3,6  
4,8  
6,0  
7,2  
250,0  
200,0  
150,0  
100,0  
50,0  
9,8  
7,9  
5,9  
3,9  
Target 200 x 200 mm  
1÷2.5  
57.5  
17.6  
Target Ø 25 mm  
2,0  
77.7÷79.2  
14  
0,0  
0,0  
PLUG  
-50,0  
-100,0  
-150,0  
-200,0  
-250,0  
-2,0  
-3,9  
-5,9  
-7,9  
-9,8  
0
400  
800  
1.200  
1.600  
2.000  
2.400  
Distance (mm)  
UA 18 CAD 22 ...  
Specifications are subject to change without notice (04.01.2017)  
3
Programming setup  
General set up of sensing point P1 (longest distance) and P2 (shortest distance) independently of the sensor type  
or function.  
1) Mount the sensor in the selected application.  
2) Place a target in front of the sensor at the maximum required distance (P1), then press shortly on the teach-button.  
The yellow LED switches Off and then On again after a maximum of 2 seconds. Now, the distance (P1) is saved in  
the sensor, and the target can be moved. I)  
3) Place the target at the minimum distance requested (P2), then press shortly on the teach-button. The yellow LED  
turns Off and then flashes 5 times. Now, the distance (P2) is saved in the sensor and the target can be moved. II)  
I) P1 can be set to maximum exceeding the family specification for the sensor by removing the target in front of  
the sensor. Push and hold the teach-button for more than one second and the sensing distance is set at a unique  
distance for this sensor only.  
II) The second switch point can be set to minimum by setting the target within the blind zone close to the sensor  
head or by covering the sensor head with your hand while teaching P2.  
Sensors with 2 digital outputs: UA..CAD..PP/NP types, Normal sensing function or Adjustable Hysteresis  
1) The factory settings are normal sensing function.  
2) Push and hold the teach-button for 8 seconds (12 for UC18CAD22..) until the yellow LED flashes fast, then release  
the teach-button and the LED will flash 5 times to acknowledge the change in function.  
Now, the sensor is in adjustable hysteresis mode.  
3) To switch back to normal function, repeat step 2.  
Installation Hints  
To avoid interference from inductive voltage/ Relief of cable strain  
current peaks, separate the prox. switch  
Protection of the sensing face  
Switch mounted on mobile carrier  
power cables from any other power cables,  
e.g. motor, contactor or solenoid cables  
Incorrect  
Correct  
The cable should not be pulled  
Any repetitive flexing of the  
cable should be avoided  
A proximity switch should not serve as  
mechanical stop  
Delivery Contents  
• Ultrasonic sensor: UA18CAD....  
• Installation instruction  
• Mounting:  
2 x M18 Nuts  
2 x rubber washers  
Packaging: Carton box 35 x 107 x 173 mm  
4
Specifications are subject to change without notice (04.01.2017)  

相关型号:

UA18CAD22PGM1TI

Ultrasonic Diffuse, Analogue and Digital Output Types UA18CAD......TI
CARLOGAVAZZI

UA18CAD22PGTI

Ultrasonic Diffuse, Analogue and Digital Output Types UA18CAD......TI
CARLOGAVAZZI

UA18CAD22PKM1TI

Ultrasonic Diffuse, Analogue and Digital Output Types UA18CAD......TI
CARLOGAVAZZI

UA18CAD22PKTI

Ultrasonic Diffuse, Analogue and Digital Output Types UA18CAD......TI
CARLOGAVAZZI

UA18CAD22PPM1TI

Ultrasonic Diffuse, Digital Output Types UA18CAD......TI
CARLOGAVAZZI

UA18CAD22PPTI

Ultrasonic Diffuse, Digital Output Types UA18CAD......TI
CARLOGAVAZZI

UA18CSD03AGM1TI

Ultrasonic Diffuse, Analogue Output
CARLOGAVAZZI

UA18CSD03AGTI

Ultrasonic Diffuse, Analogue Output
CARLOGAVAZZI

UA18CSD03AKM1TI

Ultrasonic Diffuse, Analogue Output
CARLOGAVAZZI

UA18CSD03AKTI

Ultrasonic Diffuse, Analogue Output
CARLOGAVAZZI

UA18CSD03NPM1TI

Ultrasonic Diffuse, Digital Output
CARLOGAVAZZI

UA18CSD03NPTI

Ultrasonic Diffuse, Digital Output
CARLOGAVAZZI