• Cylindrical M30 Stainless Steel INOX
AISI 316L housing
• Sensing distance: 350-3500 mm
• Power supply: 12 (15) to 30 VDC
• Outputs: 0-10 VDC or 4-20 mA and one switching
output NPN or PNP.
• Linearity error 1%
• Repeatability 1%
• Beam angle. ±±7
• Protection: Short-circuit, reverse polarity and
overvoltage
• Protection degree IP 6±
• 2 m cable or M12 plug
Product Description
Ordering Key
UA30EAD35NGM1TI
A family of diffuse ultrason-
ic sensors in Stainless steel
housing and with sensing
range from 350-3500 mm
with a resolution as low as
2.0 mm.
forms a windows detection. Ultrasonic sensor
The sensor is the ideal choice Housing style
for distance measurement, Housing size
level measurement, diameter Housing material
measurement or loop control. Housing length
Due to use of microproces- Detection principle
sor control the digital filtering Sensing distance
makes the sensor immune to Output type
most electromagnetic inter- Output configuration
The sensor contains both an
analogue and a digital output.
The output is either 0-10V or
4-20 mA and the digital output
NPN or PNP, NO or NC which
ferences.
Connection
Teach-in
Type Selection
Housing
diameter
Connec-
tion
Rated operating
dist. (Sn)
Analog
Output
Digital output
NPN/PNP
Ordering no.
M30
M30
M30
M30
M30
M30
M30
M30
Plug M12
Cable
Plug M12
Cable
Plug M12
Cable
Plug M12
Cable
350-3500 mm
350-3500 mm
350-3500 mm
350-3500 mm
350-3500 mm
350-3500 mm
350-3500 mm
350-3500 mm
4-20 mA
4-20 mA
0-10 V
NPN
NPN
NPN
NPN
PNP
PNP
PNP
PNP
UA 30 EAD 35 NG M1 TI
UA 30 EAD 35 NG TI
UA 30 EAD 35 NK M1 TI
UA 30 EAD 35 NK TI
UA 30 EAD 35 PG M1 TI
UA 30 EAD 35 PG TI
UA 30 EAD 35 PK M1 TI
UA 30 EAD 35 PK TI
0-10 V
4-20 mA
4-20 mA
0-10 V
0-10 V
Specifications
Rated operating distance (Sn) Reference target: 1 mm
metal rolled finish, size
Rated operational voltage (UB)
NG or PG versions
NK or PK versions
12 to 30 VDC
15 to 30 VDC
(ripple included)
400 x 400 mm.
350 - 3500 mm
Blind zone
≤ 350 mm
Ripple (Urpp
)
≤ 5%
Repeatability
Linearity error
Beam angle
Sensitivity
Push-button
1%
1%
7ꢀ
No-load supply current (Io)
50 mA @ UB max
Output current continuous
digital output (Ie)
Max. load capacity 100 nF
100 mA
Output current short-time
digital output (I)
Max. load capacity 100 nF
P1 (longest setpoint)
P2 (shortest setpoint)
2 mm
100 mA
0.5 mA
10 μA
Resolution
Minimum operational current
digital output (Im)
OFF-state current digital
output (Ir)
Temperature drift
Temperature compensation Yes
Hysteresis (H)
0.1%/ꢀC @ -20ꢀ to +70ꢀ C
Min. 1%
Specifications are subject to change without notice (06.06.2017)
1
UA30EAD..
Specifications (cont.)
Voltage drop digital output (Ud) ≤ 2.2 VDC @ 100 mA
Environment
Installation category
lll (IEC 60664/60664A;
60947-1)
3 (IEC 60664/60664A;
60947-1)
Protection
Digital output
Short-circuit, overvoltage
pulses and reverse polarity
Overvoltage pulses and
reverse polarity
Pollution degree
Supply
Degree of protection
IP67 (IEC 60529; 60947-1
Analogue output
Overvoltage pulses
Ambient temperature
Operating
Storage
-20° to +70°C (-4° to +158°F)
-35° to +70°C (-31° to +158°F)
Analog output
NG.. or PG.. types
NK.. or PK.. types
4 to 20 mA
0 to 10 VDC
Vibration
10 to 55 Hz, 1.0 mm/6G.
(IEC/EN 60068-2-6)
Load
4 to 20 mA
0 to 10 VDC
≤ 500 Ω
≥ 3 kΩ
Shock
30 g / 11 mS, 3 directions
(IEC/EN 60068-2-27)
Carrier frequency
112 kHz
Rated insulation voltage
< 500 VAC (rms)
Operating frequency digital
Housing
output (f)
≤ 2 Hz
Material body
AISI 316L
Epoxy-glass resin
Grilamid
Grilamid
TPE
TPE
TPE
Material front
Response time OFF-ON
Material back, plug
Material back, cable
Material push-button
Sealing around push-button
Material sealing front
digital output (tON
)
≤ 250 mS
≤ 250 mS
Response time ON-OFF
digital output (tOFF
)
Response time analog output ≤ 500 mS
Power ON delay
≤ 500 mS
Connection
Cable
PVC, grey, 2 m,
Output function, open
collector
By sensor type
4 x 0.34 mm2, Ø = 4.7 mm
M12, 4-pin (CON.
Plug
14-series)
NPN or PNP
Output switching function
One open collector transis-
tor and one analogue
Tightening torque
≤ 100 Nm
output to be configured as:
- Windows function with
N.O or N.C. output.
- Analogue output with
positive or negative slope.
Weight
Cable version
Plug version
220 g
150 g
CE-marking
Approvals
Yes
cULus (UL508)
Indication
Output ON
Echo received
Yellow LED
Green LED
Wiring Diagram
Detection Range
X
Target
Y
Distance (feet)
4.9 6.6
Sensor
BN1
WH2
BN1
WH2
0
1.6
3.3
8.2
9.8 11.5
400
300
200
100
0
15.7
11.8
7.9
BK4
BK4
I
PNP:
U
BU3
BU3
3.9
Voltage
Current
0
BN1
BN1
-100
-200
-300
-400
-3.9
-7.9
-11.8
-15.7
I
BK4
BK4
U
NPN:
WH2
WH2
BU3
BU3
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Distance (m)
2
Specifications are subject to change without notice (06.06.2017)
UA30EAD..
Dimensions
Plug
Cable
5
5
Teach
Teach
Teach
Teach
Yellow
Green
Yellow
Green
10.5
10.5
2
77
2
77
93
100
Programming setup
General set up of sensing point P1 (longest distance) and Shortest distance (P2) independent on the sensor type or
function.
1) Mount the sensor in the selected application
2) Place a target in front of the sensor at the maximum required distance (P1), then press shortly on the teach-button,
the Yellow LED switch Off and then On again after maximum 2 seconds. The distance (P1) is now saved in the
sensor, and the target can be moved. I)
3) Place the target at the minimum distance requested (P2), then press shortly on the teach-button, the yellow LED
turn Off then flash 5 times . The distance (P2) is now saved in the sensor and the target can be moved. II)
I) P1 can be set to a maximum exceeding the family specification for the sensor by removing the target in front of
the sensor, push and hold the teach-button more than one second and the sensing distance is set at a unique
distance for this sensor only. Do not use this function for an analogue output.
II) The second switch point can be set to minimum by setting the target within the blind zone close to the sensor
head or by covering the sensor head with your hand while teaching P2.
Sensors with 1 digital output and one analogue output UA..EAD..PG/PK/NG or NK types
1) The factory setting is Normally Open N.O. for the digital output and positive slope for the analogue output.
Digital output
distance
2) To reverse the slope to negative and reverse the N.O. output to Normally Closed N.C. Push the teach-button for 8
second until the yellow LED flash fast release the teach button and the LED will flash 5 times to acknowledge the
change in function.
Digital output
3) To switch back to positive slope or N.O. output, repeat step 2.
Specifications are subject to change without notice (06.06.2017)
3
UA30EAD..
Installation Hints
To avoid interference from inductive voltage/ Relief of cable strain
current peaks, separate the prox. switch
Protection of the sensing face
Switch mounted on mobile carrier
power cables from any other power cables,
e.g. motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled
Any repetitive flexing of the
cable should be avoided
A proximity switch should not serve as
mechanical stop
Delivery Contents
Accessories
• Connector type CONB14NF.. series
• Ultrasonic sensor: UA30EAD....
• Installation instruction
• Mounting: 2 x M30 Nuts
• Packaging: Carton box 35 x 107 x 173 mm
4
Specifications are subject to change without notice (06.06.2017)
相关型号:
©2020 ICPDF网 联系我们和版权申明