SIL842970 [CELDUC]
AC Semiconductor Contactor pitch 22,5mm compact size and DIN rail mounting.; AC半导体接触器间距22,5mm紧凑的尺寸和DIN导轨安装。型号: | SIL842970 |
厂家: | celduc-relais |
描述: | AC Semiconductor Contactor pitch 22,5mm compact size and DIN rail mounting. |
文件: | 总4页 (文件大小:267K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
S/CLP/SIL842970/B/21/04/2004
®
celpac
page 1 / 4GB
AC Semiconductor Contactor
pitch 22,5mm
SIL842970
compact size and DIN rail mounting.
Output : 12-275VAC 25A(*)
Input : 150-240VAC/DC
❏ Ready to use Single-Phase Relay: " Install it & Forget it!"
❏ Zero cross model : 12-275VAC 25A alternistor on
output. I2t value > 312A2s .
❏ Large control range : 150-240VAC-DC .
Green LED visualization on the input.
❏ Very high immunity : Voltage protection on output
and input- 4kV according IEC61000-4-4 & 5
❏ IP20 housing
❏ Low leakage current (<1mA) and low zero cross
voltage ( <10V)
❏ Mounting and dismounting on DIN rail without any
tool or directly mountable on panel.
❏ Designed in conformity with EN60947-4-3
(*) see conditions (thermal curve page 3)
20A
(IEC947-4-3)-UL-cUL
230VAC 50hz
Dimensions :
Protection
L1
SSR
T1
Typical
application:
4kW resistor
A2 A1
Commande
(AC-51 load)
on 230 VAC
charge
Proud to serve you
celduc
All technical caracteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
r e l a i s
S/CLP/SIL842970/B/21/04/2004
®
celpac
page 2 / 4GB
Control characteristics (at 25°C)
Input : Ic = f( Uc)
DC
8
6
4
2
0
Paramètre / Parameter
Control voltage : AC control
Control voltage : DC control
Control current (@ Uc )
Release voltage
Symbol Min
Nom Max Unit
Uc
Uc
150
110
3
230
240
240
7
VAC
VDC
mA
V
Ic
Uc off
1
Input LED
green
0
50
100
150
200
250
Input immunity : EN61000-4-4
Input immunity : EN61000-4-5
2kV
2KV
U c (V)
Output characteristics (at 20°C)
Parameter
Conditions
Symbol
Ue
Uemin-max
Up
Typ.
230
12-275
600
Unit
Load voltage
Operating range
Peak voltage
V rms
V rms
V
Clamping voltage
Zero cross level
Latching voltage
Uclamp
Usync
Ua
430 (@1mA)
V
V
V
10
8
Ie nom
AC-51 nominal current : permanent
AC-53 nominal current
Non repetitive overload current
On state voltage drop (typical value)
Dynamic resistance (typical value)
Output Power dissipation (typical value)
( see Fig. 2 page 3)
Ie AC-51
Ie AC-53
Itsm
25
5
250
0,85
15
A rms
A rms
A
V
mW
W
tp=10ms (Fig. 3)
@ 25°C
Vt
rt
Pd
0,9xIe+0,015xIe2
Thermal resistance between junction to air : calm air ( ventilation in the cabinet)
Off state leakage current
Minimum load current
Turn on time
Turn off time
Operating frequency range
Off state dv/dt
Maximum di/dt non repetitive
I2t (<10ms)
Rthj/a
Ilk
Iemin
ton max
toff max
f
dv/dt
di/dt
I2t
3,8 (3,3)
K/W
mA
mA
ms
ms
Hz
V/µs
A/µs
A2s
@Ue, 50Hz
<1
5
30
30
0,1-440
500
50
312
Uc nom DC ,f=50Hz
Uc nom DC ,f=50Hz
Conducted immunity level
Conducted immunity level
Short circuit protection
IEC 1000-4-4 (burst)
IEC 1000-4-5(schocks)
FERRAZ
4kV criterion A
4kV criterion A
gRC 25A 14x51 165A2s
General characteristics (at 20°C)
Input to output insulation
Ui
4000
VRMS
Output to case insulation
Insulation resistance
Rated impulse voltage
Ui
Ri
Uimp
2500
100 (@500VDC)
VRMS
MW
V
4000
Protection level / CEI529
-
IP20
Pollution degree
-
2
Vibration resistance 10 -55 Hz according to CEI68 :
Shocks resistance according to CEI68 ( on DIN rail / with screws)
Ambient temperature (with no icing or condensation)
Storage temperature (with no icing or condensation)
Ambient humidity
double amplitude
1,5
30/50
-30 /+80
-30/+100
40 to 85
mm
g
°C
°C
%
-
-
HR
Weight
260
g
Conformity
Conformity
EN60947-4-3 (IEC947-4-3)
UL/cUL pending
www.celduc.com
r
e
l
a
i
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : celduc-relais@celduc.com
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
S/CLP/SIL842970/B/21/04/2004
®
celpac
page 3 / 4/GB
Thermal specifications .
Current according ambient temperature :
Ø
The curve "1" gives the limits of the product.
25
20
15
The temperature reached are acceptable for the compo-
nents. These values are in compliance with most of SSRs
manufacturers.
In a cabinet with a minimum of ventilation or a non perma-
nent current, these values are correct.
1
2
Ø
The curve "2" gives the limits of the product accord-
ing to EN60947-4-3 with a maximum rise temperature of
50°C (@40°C) for a permanent working and in air calm
( test during 8 hours).
10
5
Ø
For a non permanent current, you can calcule the av-
erage power = Pd x duty cycle and check the rise tempera-
ture : Tj = Pd x Rthj/a (Pd and Rthj/a are given page 2)).
The junction temperature must not exceed 125°C at the
maximum ambient temperature.The maximum current is
limited to the size of the alternistor = 25A.
0
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
T ambient (°C)
Ø
The thermal constant (Cth) of the product is 7
minutes. That means the rise temperature is only 63% of the
fig 2
stabilized temperature after a running time of
7 minutes.
Fig.3 Surge current : Itsm (Apeak) = f(t) for 25A models with Itsm =250A
Overload current .
1 - No repetitive Itsm is given without voltage
reapplied . This curve is used for the
determination of the protection.
250
1
200
150
2 - Repetitive Itsm is given for inrush current
with initial Tj = 70°C. In normal working , this
curve musn't be exceed. Be carefull, the
repetition of the surge current decrease the
lifetime SSR's .
No repetive surge current without voltage reapplied.
2
100
50
Repetive surge current with voltage reapplied.
0
0,01
0,1
1
10
fig 3
t(s)
Mounting and dismounting on DIN rail without any tool.
Panel Mounting
M5
M4
Mount ing
88±2mm
DIN rail connected to
protection wire (ground) .
Dismount ing
12,7mm
Ø
Warning ! semiconductor relays don't provide any galvanic insulation between the load and the mains. Always use in
conjunction with an adapted circuit breaker with isolation feature or a similar device in order to ensure a reliable isolation in the
event of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration ...).
www.celduc.com
r
e
l
a
i
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : celduc-relais@celduc.com
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
S/CLP/SIL842970/B/21/04/2004
®
celpac
page 4 / 4GB
wires
(mm2)
torques
screwdriver
L
L
Connections .
screwdriver
Ø
For the output terminals, the wire cross sections must
be adapted to the load current and to the overcurrent protection
device characteristics. The relay rated voltage must be adapted
to the mains rated voltage.
control
1 x(0,75-->2,5)
L = 6mm
0,4N.m
(0,6N.m max)
3,5x0,5mm
Ø
celpac use screw clamp connections.
Power
1,2N.m
(1,8N.m max)
Pozidriv2/
0,8x5,5 (1x6)
1x(1,5-->16) 1 x(1,5-->10)
L = 10mm
Mounting
Ø
Warning : only in vertical position. The user should protect heat sensitive materials as
well as persons against any contacts with the heatsink. For non vertical mounting , the load
current must be 50% lower than the rated one . For a good cooling, the SSR needs an air
convection. Less convection air produces an abnormal heating. Keep a distance between
the upper SSR and the lower SSR. In case of no space between two SSR ( zero space
between two SSRs) , please reduce the load current. For further details refer to below :
Ø
Derating current with no space between SSRs
AC-51 nominal currents are given with a space of 22,5mm between each SSR, for a
permanent current during a minimum time of 8 hours in air calm according to IEC60947-4-3.
In case of non permanent currents or in case of SSRs are mounted with no space, you must
check the heatsink temperature never exceed 90°C. When the SSRs are mounted side to
side ( no space between each relay) a derating current of 25% must be take into account.
A forced cooling ( fan inside the cabinet) improves significantly the thermal performances.
vert ical
posit ion
8 0 mm
Typical application : LOADS
SIL product is designed mainly for AC-51 résistive load. AC-53 motor current are
also given . For other loads, check the inrush current at turn ON and possible overvoltages
at turn OFF or consult us :
* AC-55b : Incandescent lamps : Inrush current is generally 10 times In during few 10ms.
So limit the nominal current at about 10A.
* AC-55a : Electric discharge lamp : These loads often have overcurrent at turn ON and
overvoltage at turn OFF, so we advise to use 400VAC SSR on 230VAC mains.
* AC-56a : Transformers loads: Very high inrush current up to 100 times In . We advise to
use random SSR.
1 ~
* AC-56b : Capacitors loads: Very high current at turn ON and overvolatge at turn OFF,
please consult us with 1600V peak SSR with high inrush current.
Fuse
Fusible
Protection :
2
2
To protect the SSR against a short-circuit of the load , use a fuse with a I t value = 1/2 I t
value specified page 2. A test has been made with FERRAZ fuse ( see page 2).
L1
T1
It is possible to protect SSR by MCB ( miniature circuit breaker). In this case, see application
2
2
note ( SSR protection) and use a SSR with high I t value (5000A s minimum)
EMC :
Ø
Immunity :
We give in our data-sheets, the immunity level of our SSRs according to the main
standards for this type of products : EN61000-4-4 &5. You can see the high immunity level
in comparison with the products on the market.
A1
A2
Ø
Emission:
cont rol
SSRs are complex devices which must be interconnected with other equipment
Load
Charge
(loads, cables,etc.) to form a system. Because the other equipment or the interconnections
may not be under the control of celduc, it shall be the responsibility of the system integrator
to ensure that systems containing SSRs comply with the requirements of any rules and
regulations applicable at the system level.The very low zero cross voltage (<10V) improves
the conducted emission level in comparison with most of SSR on the market with zero cross
voltage higher than 25V. Consult celduc laboratory which can make some tests in your
application.
N
www.celduc.com
r
e
l
a
i
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : celduc-relais@celduc.com
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
相关型号:
UL1042
UL1042 - Uk砤d zr體nowa縪nego mieszacza iloczynowegoWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
ZXFV201
QUAD VIDEO AMPLIFIERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX
ZXFV201N14
IC-SM-VIDEO AMPWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX
ZXFV201N14TA
QUAD VIDEO AMPLIFIERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX
ZXFV201N14TC
QUAD VIDEO AMPLIFIERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX
Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
ZXFV302N16
IC-SM-4:1 MUX SWITCHWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
ZXFV4089
VIDEO AMPLIFIER WITH DC RESTORATIONWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX
©2020 ICPDF网 联系我们和版权申明