SIL867170 [CELDUC]
AC Semiconductor Contactor pitch 22,5mm compact size and DIN rail mounting.; AC半导体接触器间距22,5mm紧凑的尺寸和DIN导轨安装。型号: | SIL867170 |
厂家: | celduc-relais |
描述: | AC Semiconductor Contactor pitch 22,5mm compact size and DIN rail mounting. |
文件: | 总4页 (文件大小:123K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
celpac®
S/CLP/SIL867170/C/21/04/2004
page 1 / 4GB
AC Semiconductor Contactor
pitch 22,5mm
SIL867170
compact size and DIN rail mounting.
Output : 24-510VAC 35A(*)
Input : 3,5-32VDC / I<10mA
❏ Ready to use Single-Phase Relay: " Install it & Forget it!"
❏ Zero cross model : 24-510VAC 75A
back to back thyristors on output -
TMS2 technology -
I2t value > 5000A2s for circuit breakers protection.
❏ Large control range : 3,5-32VDC with an input
current < 10 mA on all the range.
Green LED visualization on the input.
❏ Very high immunity : Voltage protection on output
and input- 4kV according IEC61000-4-4 & 5
❏ IP20 housing
❏ Low leakage current (<1mA) and low zero cross
voltage.
❏ Mounting and dismounting on DIN rail without any
tool or directly mountable on panel.
❏ Designed in conformity with EN60947-4-3 (IEC947-4-3)
and EN60950
-UL-cUL
(*) see conditions (thermal curve page 3)
28A
400VAC 50hz
Dimensions :
Protection
MCB
L1
SSR
T1
Typical
application:
A2 A1
10kW resistor
(AC-51 load)
on 400 VAC
+
-
Commande
Load
Proud to serve you
celduc
All technical caracteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
r e l a i s
S/CLP/SIL867170/C/21/04/2004
celpac®
page 2 / 4GB
Control characteristics (at 25°C)
Input : Ic = f( Uc)
DC
Paramètre / Parameter
Control voltage
Control current (@ Uc )
Release voltage
Symbol Min
Nom Max Unit
12
10
8
Uc
3,5
<10
2
5-12-24 32
V
mA
V
Ic
<10
<10
Uc off
6
Input LED
Reverse voltage
Clamping voltage
green
32
42
4
Urv
Uclamp
V
V
2
Input immunity : EN61000-4-4
Input immunity : EN61000-4-5
2kV
2KV
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32
Uc ( VDC)
Output characteristics (at 20°C)
Parameter
Conditions
Symbol
Ue
Uemin-max
Up
Typ.
400
24-510
1200
Unit
V rms
V rms
V
Load voltage
Operating range
Peak voltage
Clamping voltage
Zero cross level
Latching voltage
Uclamp
Usync
Ua
820 (@1mA)
V
V
V
20
8
Ie nom
AC-51 nominal current : permanent
AC-53 nominal current
Non repetitive overload current
On state voltage drop (typical value)
Dynamic resistance (typical value)
( see Fig. 2 page 3)
Ie AC-51
Ie AC-53
Itsm
35
16
1000
0,75
8
A rms
A rms
A
V
mW
tp=10ms (Fig. 3)
@ 25°C
Vt
rt
Output Power dissipation (typical value)
Pd
0,7xIe+0,08xIe2
W
Thermal resistance between junction to air
Off state leakage current
Minimum load current
Turn on time
Turn off time
Operating frequency range
Off state dv/dt
Rthj/a
Ilk
Iemin
ton max
toff max
f
dv/dt
di/dt
I2t
3,2 (2,5)
K/W
mA
mA
ms
ms
Hz
V/µs
A/µs
A2s
@Ue, 50Hz
<1
5
10
10
0,1-440
500
50
5000
Uc nom DC ,f=50Hz
Uc nom DC ,f=50Hz
Maximum di/dt non repetitive
I2t (<10ms)
Conducted immunity level
Conducted immunity level
Short circuit protection
IEC 1000-4-4 (burst)
IEC 1000-4-5(schocks)
FERRAZ
4kV criterion A
4kV criterion A
gRC 25A/32A/50A/63A 14x51
General characteristics (at 20°C)
Input to output insulation
Output to case insulation
Insulation resistance
Rated impulse voltage
Ui
Ui
Ri
Uimp
4000
4000
100 (@500VDC)
VRMS
VRMS
MW
V
4000
Protection level / CEI529
Pollution degree
-
-
IP20
2
Vibration resistance 10 -55 Hz according to CEI68 :
Shocks resistance according to CEI68 ( on DIN rail / with screws)
Ambient temperature (with no icing or condensation)
Storage temperature (with no icing or condensation)
Ambient humidity
Weight
double amplitude
1,5
30/50
-30 /+80
-30/+100
40 to 85
mm
g
°C
°C
%
-
-
HR
260
g
Conformity
Conformity
EN60947-4-3 (IEC947-4-3)
EN60950 UL/cUL pending
Proud to serve you
celduc
All technical caracteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
r e l a i s
celpac®
S/CLP/SIL867170/C/21/04/2004
page 3 / 4/GB
Thermal specifications .
Current according ambient temperature :
45
40
35
30
25
20
15
10
5
Ø
The curve "1" gives the limits of the product.
The temperature reached are acceptable for the com-
ponents. These values are in compliance with most of
SSRs manufacturers.
In a cabinet with a minimum of ventilation or a non
permanent current, these values are correct.
1
Ø
The curve "2" gives the limits of the product
according to EN60947-4-3 with a maximum rise
temperature of 50°C (@ 40°C) for a permanent work-
ing and in air calm ( test during 8 hours).
2
Ø
For a non permanent current, you can calcule
the average power = Pd x duty cycle and check the
rise temperature : Tj = Pd x Rthj/a (Pd and Rthj/a are
given page 2)). The junction temperature must not
exceed 125°C at the maximum ambient temperature.
The maximum current is limited to the size of the
thyristors = 75A.
0
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Tambient(°C)
Ø
The thermal constant (Cth) of the product is 7
minutes. That means the rise temperature is only 63%
of the stabilized temperature after a running time of
7 minutes.
fig 2
F ig. 3
Surge current : Itsm (Apeak) = f(t)
Overload current .
1 - No repetitive Itsm is given without voltage
1500
reapplied . This curve is used for the
determination of the protection.
1000
1
2 - Repetitive Itsm is given for inrush current
with initial Tj = 70°C. In normal working , this
curve musn't be exceed. Be carefull, the
repetition of the surge current decrease the
lifetime SSR's .
500
0
2
fig 3
0,01
0,1
1
10
t (s)
Mounting and dismounting on DIN rail without any tool.
Panel Mounting
M5
M4
Mount ing
88±2mm
DIN rail connected to
protection wire (ground) .
Dismount ing
12,7mm
Ø
Warning ! semiconductor relays don't provide any galvanic insulation between the load and the mains. Always use in
conjunction with an adapted circuit breaker with isolation feature or a similar device in order to ensure a reliable isolation in the
event of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration ...).
Proud to serve you
celduc
All technical caracteristics are subject to change without previous notice.
r e l a i s
Caractéristiques sujettes à modifications sans préavis.
S/CLP/SIL867170/C/21/04/2004
celpac®
page 4 / 4GB
wires
torques
screwdriver
Connections .
L
L
(mm2)
Ø
For the output terminals, the wire cross sections must
screwdriver
be adapted to the load current and to the overcurrent protection
device characteristics. The relay rated voltage must be adapted
to the mains rated voltage.
control
1 x(0,75-->2,5)
L = 6mm
0,4N.m
(0,6N.m max)
3,5x0,5mm
Ø
celpac use screw clamp connections.
Power
1x(1,5-->16) 1 x(1,5-->10)
L = 10mm
1,2N.m
(1,8N.m max)
Pozidriv2/
0,8x5,5 (1x6)
Mounting
Ø
Warning : only in vertical position. The user should protect heat sensitive materials as
well as persons against any contacts with the heatsink. For non vertical mounting , the load
current must be 50% lower than the rated one . For a good cooling, the SSR needs an air
convection. Less convection air produces an abnormal heating. Keep a distance between
the upper SSR and the lower SSR. In case of no space between two SSR ( zero space
between two SSRs) , please reduce the load current. For further details refer to below :
Ø
Derating current with no space between SSRs
AC-51 nominal currents are given with a space of 22,5mm between each SSR, for a
permanent current during a minimum time of 8 hours in air calm according to IEC60947-4-3.
In case of non permanent currents or in case of SSRs are mounted with no space, you must
check the heatsink temperature never exceed 90°C. When the SSRs are mounted side to
side ( no space between each relay) a derating current of 25% must be take into account.
A forced cooling ( fan inside the cabinet) improves significantly the thermal performances.
vert ical
posit ion
80mm
Typical application : LOADS
SIL product is designed mainly for AC-51 résistive load. AC-53 motor current are
also given . For other loads, check the inrush current at turn ON and possible overvoltages
at turn OFF or consult us :
* AC-55b : Incandescent lamps : Inrush current is generally 10 times In during few 10ms.
So limit the nominal current at about 20A.
* AC-55a : Electric discharge lamp : These loads often have overcurrent at turn ON and
overvoltage at turn OFF, so we advise to use 400VAC SSR on 230VAC mains.
* AC-56a : Transformers loads : Very high inrush current up to 100 times In . We advise to
use random SSR.
1 ~
* AC-56b : Capacitors loads : Very high current at turn ON and overvolatge at turn OFF,
please consult us with 1600V peak SSR with high inrush current.
MCB
Protection :
2
This relay with high I t value can be protected against short-circuit on the load by Miniature
L1
T1
Circuit Breaker. This protection is possible with a limited short-circuit prospective current.
See application note : SSR protection.
EMC :
Ø
Immunity :
We give in our data-sheets, the immunity level of our SSRs according to the main
standards for this type of products : EN61000-4-4 &5. You can see the high immunity level
in comparison with the products on the market.
+
-
A1
A2
cont rol
Ø
Emission:
Load
Charge
SSRs are complex devices which must be interconnected with other equipment
(loads, cables,etc.) to form a system. Because the other equipment or the interconnections
may not be under the control of celduc, it shall be the responsibility of the system integrator
to ensure that systems containing SSRs comply with the requirements of any rules and
regulations applicable at the system level. The very low zero cross voltage (<20V) improves
the conducted emission level in comparison with most of SSR on the market with zero cross
voltage higher than 50V. Consult celduc laboratory which can make some tests in your
application.
N
www.celduc.com
r
e
l
a
i
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : celduc-relais@celduc.com
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
相关型号:
UL1042
UL1042 - Uk砤d zr體nowa縪nego mieszacza iloczynowegoWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
ZXFV201
QUAD VIDEO AMPLIFIERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX
ZXFV201N14
IC-SM-VIDEO AMPWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX
ZXFV201N14TA
QUAD VIDEO AMPLIFIERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX
ZXFV201N14TC
QUAD VIDEO AMPLIFIERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX
Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
ZXFV302N16
IC-SM-4:1 MUX SWITCHWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC
ZXFV4089
VIDEO AMPLIFIER WITH DC RESTORATIONWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX
©2020 ICPDF网 联系我们和版权申明