TRG21A150 [CINCON]
20W SWITCHING ADAPTER;型号: | TRG21A150 |
厂家: | Cincon |
描述: | 20W SWITCHING ADAPTER 开关 |
文件: | 总2页 (文件大小:561K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
V12
TRG21 SERIES
20W SWITCHING ADAPTER
︳
Features
* Universal Input Range 90~264VAC
* Efficiency to 85%
* Continuous Short Circuit Protection
* Over Voltage Protection
* No Load Input Power < 0.3W
* Leakage Current < 0.1mA
rd
* UL60601-1/IEC60601-1/EN60601-1 3 Medical
safety and IEC60950-1/EN60950-1 ITE approved
* AC Inlet IEC320/C8
* Meets 2MOOP
*
Meet CEC and Erp Level V
≦
(Output Cable Length 1800mm 18AWG)
≦
(TRG21A050: Length 1200mm 18AWG)
OUTPUT
RATED
INPUT
VOLTAGE
OUTPUT
OUTPUT
VOLTAGE
ACCURACY
RIPPLE &
NOISE
LOAD
REG.
%
MODEL
Eff.
VOLTAGE CURRENT
POWER
5%
4%
3%
3%
2%
2%
TRG21A050 90~264 VAC
TRG21A090 90~264 VAC
TRG21A120 90~264 VAC
TRG21A150 90~264 VAC
TRG21A180 90~264 VAC
TRG21A240 90~264 VAC
5.0 V
9.0 V
12 V
15 V
18 V
24 V
3.0 A
2.3 A
1.8 A
1.4 A
1.2 A
0.9 A
15.0 W
20.7 W
21.6 W
21.0 W
21.6 W
21.6 W
50 mV
50 mV
2ꢀ
2ꢀ
2ꢀ
2ꢀ
2ꢀ
2ꢀ
75ꢀ
80ꢀ
81ꢀ
83ꢀ
84ꢀ
85ꢀ
90 mV
100 mV
100 mV
100 mV
Specifications are subject to change without notice.
1
V12
Specifications
TRG21 Series De-rating Curve
INPUT SPECIFICATIONS:
100%
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Input Current ……………………………………….……………..... 0.3 to 0.5A
80%
60%
40%
20%
0%
20LFM(NaturalConvection)
℃
Inrush Current …………….…Cold Start@25 ............. 40A max. @230Vac
Leakage Current …………………………………………………… 0.1mA max.
OUTPUT SPECIFICATIONS:
Voltage Accuracy ..........................................…………............... 2.0% max.
Line Regulation (note3) ……………….…………...................…. 1.0% max.
Load Regulation (note4) ………………......……….…….........…...... see table
-20 -10
0
10
20
30
40 50 60
o
Ambient Temperature( C)
Hold-up Time …………………………….…………..…… 8ms typ. @115Vac
SAFETY AND EMISSION:
Short Circuit Protection …………….………………………….…… Continuous
Over Voltage Protection(TVS) …… 115%-140% of nominal output voltage
CE Directive ……………………………….……… 2004/108/EC, 93/42/EEC
Emissions … EN60601-1/EN61204-3/EN55022/CISPR Class B, EN55024
rd
Safety Approvals …….................. UL60601-1, IEC60601-1, EN60601-1 3
GENERAL SPECIFICATIONS:
Isolation ………………………………..………… Input to output = 5,656VDC
IEC60950-1,EN60950-1
Efficiency ……………………………………………………………….. see table
Switching Frequency ………………………………….………….. 100KHz typ.
NOTE:
1. Voltage accuracy is set of 60% rated load.
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Ripple & Noise measuring @20MHz BW.
℃
Operating Temperature ............................... -20 ~ 60 (see derating curve)
℃
Storage Temperature ……………………………...….......……........ -25~85
Cooling ………………………………….………………… Natural Convection
Humidity .................................................... 93% RH max. Non condensing
3. Line regulation is measured from high line to low line with full load.
4. Load regulation is measured from 60% to full load and from 60% to
20% load (60% +/- 40% load).
℃
MTBF ……. MIL-STD-217F, GB, at 25 /115VAC ..……… 400Khrs min.
Dimensions ……….. 3.000x1.780x0.870 inches (76.20x45.20x22.10mm)
Weight …………………………………………………… 140g(0.31Pounds)
Mechanical Specification
All Dimensions are in inches(mm)
Tolerance:Inches:X.XXX±0.02
Millimeters:X.XX±0.5
3.000[76.20]
48.031[1220.00]±1.969[50.00]
DC Plug type: V+ ─●)─ V-
DC Plug :Right Angle(ψ5.5/ψ2.1) L12mm
18AWG / 1220mm
0.008[0.20]
IEC320/C8
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified