TRG502V-A-XXE01 [CINCON]

6W SWITCHING ADAPTER;
TRG502V-A-XXE01
型号: TRG502V-A-XXE01
厂家: Cincon    Cincon
描述:

6W SWITCHING ADAPTER

开关
文件: 总2页 (文件大小:231K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
V16  
TRG500V SERIES  
6W SWITCHING  
ADAPTER  
Features  
* Universal Input Range 90~264VAC  
* Meets EN55022 Class B and  
CISPR/FCC Class B  
* Continuous Short Circuit Protection  
* Over Voltage Protection  
* Meet CEC & ErP Level V  
(Output Cable Length 1800mm)  
Ordering information  
TRG5XX -  
X
-
XX  
X
XX  
Model No.  
AC Plug Type DC Plug Type OVP  
DC Cable Length and Type  
01: 720mm  
A: USA 2 Pin  
E: With OVP  
E: Europe 2 Pin  
U: British 3 Pin  
S: Australia 2 Pin  
02: 1220mm  
03: 1800mm  
11: 720mm with Ferrite Core  
12: 1220mm with Ferrite Core  
13: 1800mm with Ferrite Core  
* 20AWG / UL2468  
VOLTAGE  
ACCURACY  
NOTE1  
LINE  
REGULATION  
NOTE3  
LOAD  
REGULATION  
NOTE4  
RIPPLE &  
NOISE  
OUTPUT  
OUTPUT  
%EFF.(Typ.)  
MODEL  
VOLTAGE  
CURRENT  
NOTE5  
NOTE 2  
1%  
TRG501-15V  
TRG501V  
TRG502V  
TRG503V  
TRG506V  
TRG507V  
TRG508V  
TRG510V  
TRG511-1V  
TRG513-1V  
15 V  
12 V  
10 V  
9 V  
400 mA  
500 mA  
600 mA  
650 mA  
650 mA  
650 mA  
650 mA  
650 mA  
1000 mA  
1200 mA  
68%  
68%  
68%  
68%  
67%  
67%  
67%  
67%  
67%  
66%  
±
±
±
3%  
1%  
2%  
1%  
±
±
±
3%  
1%  
2%  
1%  
±
±
±
3%  
1%  
2%  
1%  
±
±
±
3%  
1%  
2%  
8 V  
1%  
±
±
±
3%  
1%  
3%  
7.5 V  
7.0 V  
6.5 V  
6.0 V  
5.0 V  
1%  
±
±
±
3%  
1%  
3%  
1%  
±
±
±
3%  
1%  
3%  
1%  
±
±
±
3%  
1%  
3%  
1%  
±
±
±
3%  
1%  
4%  
1%  
±
±
±
3%  
1%  
4%  
Specifications are subject to change without notice.  
1
V16  
Specifications  
TRG500V Series Derating Curve  
INPUT SPECIFICATIONS:  
100%  
80%  
Voltage …....………........…...................................................... 90~264Vac  
Frequency ………………………………………….……………..... 50 to 60Hz  
Input Current ………………….…………….................................... 0.5A max.  
60%  
20LFM(Natural Convection)  
Inrush Current …………………...... Cold Start @25 50A max. @240Vac  
40%  
Leakage Current …………………………………………….…… 0.25mA max.  
20%  
0%  
OUTPUT SPECIFICATIONS:  
Hold-up Time …………………………………………… 10ms typ. @115Vac  
Short Circuit Protection ………………………… Continuous(Auto Recovery)  
Over Voltage Protection …………………...........................................… Yes  
0
10  
20  
30  
40  
50  
60  
o
Ambient Temperature( C)  
Temperature Coefficient …………………….............................… 0.05%/  
GENERAL SPECIFICATIONS:  
NOTE:  
Isolation ………………………………………… Input to output = 4,242VDC  
1. Voltage accuracy at 60% full load.  
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for  
Ripple & Noise measurement @20MHz BW.  
Operating Temperature ............................... 0 ~ 60 (see derating curve)  
Storage Temperature ……………………………...….......…........ -20 ~ 85  
Humidity …………………...….......……........ 93% RH max. Non condensing  
Cooling …………………………………….………………. Natural Convection  
Switching Frequency ………………………………………… 87KHz Typical  
3. Line regulation is measured from 100Vac to 240Vac full load.  
4. Load regulation is measured from 60% to 100% full load and from 60%  
20% full load (60% +/- 40% full load).  
5. Typical efficiency at 230VAC and full load at 25.  
MTBF …… MIL-HDBK-217F, GB, at 25 /115VAC ………. 200Khrs min.  
Altitude …………………………………………………………………… 2000m  
Dimensions …….….. 2.835x2.047x1.378 inches (72.00x52.00x35.00mm)  
Weight …………………………………………………….. 135g (0.30Pounds)  
6. ”Various TR Series adapters are PSE certified. PSE certification  
alone is not sufficient for importation into Japan. A valid PSE mark  
must contain the name of the importer as shown in the example below.  
If PSE mark is required, the name of the registered importer must be  
SAFETY AND EMC:  
Emission and lmmunity ………… EN55022 Class B, FCC Part 15 Class B  
EN61000-6-3,EN61000-3-2,EN61000-3-3  
supplied to Cincon on order placement. Product labels will not contain  
PSE mark if importer name is not supplied. Consult factory or local  
representative for details”  
EN55024, EN61204-3, EN61000-6-1  
Safety ………………..……………… IEC60950-1, EN60950-1, UL60950-1  
Mechanical Specification  
All Dimensions are in inches(mm)  
Tolerance:Inches:X.XXX±0.02  
Millimeters:X.XX±0.5  
FIG.A  
FIG.E  
0.539[13.70]±0.027[0.70]  
70.866[1800.00]±1.969[50.00]  
70.866[1800.00]±1.969[50.00]  
0.500[12.70]±0.011[0.30]  
1.378[35.00]  
0.688[17.50]±0.019[0.50]  
1.378[35.00]  
FIG.S  
FIG.U  
70.866[1800.00]±1.969[50.00]  
70.866[1800.00]±1.969[50.00]  
1.378[35.00]  
1.378[35.00]  
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified  
2

相关型号:

TRG502V-A-XXE02

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON

TRG502V-A-XXE03

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON

TRG502V-A-XXE11

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON

TRG502V-A-XXE12

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON

TRG502V-A-XXE13

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON

TRG502V-E-XXE01

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON

TRG502V-E-XXE02

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON

TRG502V-E-XXE03

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON

TRG502V-E-XXE11

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON

TRG502V-E-XXE12

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON

TRG502V-E-XXE13

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON

TRG502V-S-XXE01

6W SWITCHING ADAPTER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CINCON