CLL130W [CLAIREX]

Photo-IC Sensors Digital Output; 光传感器IC数字输出
CLL130W
型号: CLL130W
厂家: CLAIREX TECHNOLOGIES, INC    CLAIREX TECHNOLOGIES, INC
描述:

Photo-IC Sensors Digital Output
光传感器IC数字输出

传感器
文件: 总4页 (文件大小:195K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
Clairex  
CLL Series  
Technologies, Inc.  
Photo-IC Sensors  
Digital Output  
March, 2003  
1. OUTPUT  
3. GROUND  
0.500(12.7) min.  
2. VCC  
4. ADJUST  
4
0.157 (3.99)  
0.137 (3.48)  
TO-72  
0.048 (1.22)  
0.028 (0.71)  
3
0.187 (4.75)  
CLL130  
CLL131  
CLL133  
2
0.179 (4.55)  
0.046 (1.17)  
1
0.036 (0.91)  
0.030 (0.76) max.  
0.230 (5.84)  
0.209 (5.31)  
0.060 (1.52) max  
45°  
1. OUTPUT  
2. VCC  
3. GROUND  
4. ADJUST  
0.500(12.7) min.  
0.210 (5.33)  
0.190 (4.83)  
TO-72  
4
0.048 (1.22)  
0.028 (0.71)  
3
CLL130W  
CLL131W  
CLL133W  
0.187 (4.75)  
0.179 (4.55)  
2
0.046 (1.17)  
0.036 (0.91)  
1
0.030 (0.76) max.  
0.230 (5.84)  
0.209 (5.31)  
0.010 (0.25) max  
0.500(12.7) min.  
45°  
1. OUTPUT  
2. VCC  
3. GROUND  
0.210 (5.33)  
0.190 (4.83)  
features  
4
Output stages:  
TO-18  
0.048 (1.22)  
3
0.028 (0.71)  
a. Buffer or inverter  
0.187 (4.75)  
0.179 (4.55)  
b. Open collector or internal  
10Kpull-up  
2
CLL134  
CLL135  
CLL136  
CLL137  
0.046 (1.17)  
0.036 (0.91)  
1
Supply voltage 4.5V to 18V  
7:1 user sensitivity adjustment  
on CLL130-CLL133 and  
CLL130W-CLL133W series  
Acceptance angle:  
a. ± 15° high dome lens can  
b. ± 35° flat window lens can  
Operates to 125°C  
RoHS compliant  
0.030 (0.76) max.  
0.230 (5.84)  
0.209 (5.31)  
0.060 (1.52) max  
0.500(12.7) min.  
45°  
1. OUTPUT  
3. GROUND  
2. VCC  
0.210 (5.33)  
0.190 (4.83)  
4
2
TO-18  
0.048 (1.22)  
0.028 (0.71)  
3
description  
0.187 (4.75)  
0.179 (4.55)  
The CLL series are monolithic  
integrated circuits incorporating a  
photodiode, linear amplifier, Schmitt  
trigger for hysteresis and pulse  
shaping, and digital output with either  
10Kpull-up or open collector. The  
series includes TO-72 four leaded  
packages (with user adjustable gain)  
and TO-18 three leaded packages in  
both high dome and flat window  
configurations. Alternate pin-outs  
are available. Contact Clairex.  
CLL134W  
CLL135W  
CLL136W  
CLL137W  
0.046 (1.17)  
0.036 (0.91)  
1
0.030 (0.76) max.  
0.230 (5.84)  
0.209 (5.31)  
0.010 (0.25) max  
45°  
ALL DIMENSIONS ARE IN INCHES (MILLIMETERS)  
Revised 3/16/06  
Page 1 of 4  
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.  
Clairex Technologies, Inc.  
Phone: 972-265-4900  
1301 East Plano Parkway  
Fax: 972-265-4949  
Plano, Texas 75074-8524  
www.clairex.com  
®
Clairex  
CLL Series  
Technologies, Inc.  
Photo-IC Sensors  
Digital Output  
Schematics  
VREG  
VCC  
VCC  
VREG  
ADJ  
VOUT  
VOUT  
LA  
LA  
GND  
GND  
CLL133/CLL133W  
CLL135/CLL135W  
Open collector – inverter with Adjust  
Open collector - inverter  
VREG  
VREG  
VCC  
VCC  
ADJ  
10kΩ  
VOUT  
VOUT  
LA  
LA  
GND  
GND  
CLL134/CLL134W  
CLL131/CLL131W  
Open collector - buffer  
10kpull-up – inverter with Adjust  
VREG  
VCC  
VCC  
VREG  
10kΩ  
ADJ  
10kΩ  
VOUT  
VOUT  
LA  
LA  
GND  
GND  
CLL137/CLL137W  
CLL130/CLL130W  
10kpull-up – inverter  
10kpull-up – buffer with Adjust  
VREG  
VCC  
10kΩ  
VOUT  
LA  
GND  
CLL136/CLL136W  
10kpull-up – buffer  
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.  
Page 2 of 4  
Clairex Technologies, Inc.  
Phone: 972-265-4900  
1301 East Plano Parkway  
Fax: 972-265-4949  
Plano, Texas 75074-8524  
www.clairex.com  
®
Clairex  
CLL Series  
Technologies, Inc.  
Photo-IC Sensors  
Digital Output  
Absolute maximum ratings (TA = 25°C unless otherwise stated)  
storage temperature........................................................................................................ -65°C to +150°C  
operating temperature..................................................................................................... -65°C to +125°C  
lead soldering temperature(1)............................................................................................................260°C  
VCC supply voltage...................................................................................................................4.5V to 18V  
V
ADJ (CLL130-CLL133 and CLL130W-CLL133W only)......................................................................... 3V  
VOUT (10kpull-up series)(2) ................................................................................................................ 18V  
VOUT (open collector series)(2).............................................................................................................. 30V  
ISINK(3) ................................................................................................................................................ 25mA  
continuous power dissipation(4) ..................................................................................................... 250mW  
NOTES:  
1. 1/16” from the case for 5 seconds maximum.  
2. This rating applies when the output is in the OFF state only.  
3. This rating applies when the output is in the ON state only.  
4. Derate linearly 2.0mW/°C from 25°C free air to TA = 125°C.  
5. CLL130-CLL133 and CLL130W-CLL133W photo-IC sensors are tested with the ADJ lead open.  
6. Light source is an AlGaAs IRED with peak wavelength at 850nm.  
DEFINITIONS:  
Ee (+) is the minimum irradiance required to cause the output to change state.  
Buffer: Output is HIGH when input irradiance is >Ee (+).  
Inverter: Output is LOW when input irradiance is >Ee (+).  
electrical characteristics (TA = 25°C unless otherwise noted)  
parameter  
symbol min  
typ  
max  
units  
test conditions  
Operating supply voltage  
VCC  
4.5  
0.005  
-
-
18  
0.05  
V
mW/cm2  
4.5V VCC 18V, ADJ open,  
Positive going threshold  
irradiance(6)  
Ee (+)  
All non-suffix W parts.  
0.025  
1.1  
-
-
0.25 mW/cm2 All suffix W parts.  
EeT (+)  
EeT (-)  
Hysteresis ratio  
1.8  
12  
operate point/release point  
4.5V VCC 18V, Ee = 0  
Supply current  
ICC  
-
-
mA  
or 0.5mW, ADJ open  
-
-
30  
70  
-
-
deg.  
deg.  
All non-suffix W parts  
All suffix W parts  
Total acceptance angle  
ΘP  
Gain threshold can be adjusted on the CLL130-CLL133 and CLL130W-CLL133W series by  
placing a resistor between the ADJ and GND leads in accordance with the following table.  
Decreasing the resistance causes the output to switch at a higher threshold level.  
ADJ Resistor  
Normalized Threshold  
open  
1.00  
2.00  
2.75  
3.75  
5.00  
7.25  
10k  
4.7k  
2.2k  
1k  
Connected to GND  
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.  
Page 3 of 4  
Clairex Technologies, Inc.  
Phone: 972-265-4900  
1301 East Plano Parkway  
Fax: 972-265-4949  
Plano, Texas 75074-8524  
www.clairex.com  
®
Clairex  
CLL Series  
Technologies, Inc.  
Photo-IC Sensors  
Digital Output  
electrical characteristics (TA = 25°C unless otherwise noted)  
parameter  
symbol  
min  
typ  
max  
units  
test conditions  
CLL130/CLL130W and CLL136/CLL136W (buffer, 10kpull-up)  
V
CC = 5.0V,  
High state output voltage  
VOH  
4.5  
-
-
V
Ee (+) 0.5mW/cm2  
Low state output voltage  
Output rise and fall time  
VOL  
tr, tf  
-
-
-
75  
0.4  
-
V
ns  
VCC = 5.0V, Ee (+) = 0  
V
CC = 5.0V, Ee = 0 or  
0.5mW/cm2, f = 10kHz,  
Propagation delay  
tPHL, tPLH  
-
5
-
µs  
D.C. = 50%, RL = 330Ω  
CLL131/CLL131W and CLL137/CLL137W (inverter, 10kpull-up)  
High state output voltage  
Low state output voltage  
Output rise and fall time  
Propagation delay  
VOH  
4.5  
-
-
0.4  
-
V
V
VCC = 5.0V, Ee (+) = 0  
VCC = 5.0V,  
VOL  
-
-
-
-
Ee (+) 0.5mW/cm2  
V
CC = 5.0V, Ee = 0 or  
tr, tf  
75  
5
ns  
µs  
0.5mW/cm2, f = 10kHz,  
tPHL, tPLH  
-
D.C. = 50%, RL = 330Ω  
CLL134/CLL134W (buffer, open collector)  
High state output current  
VCC = 5.0V, VOH = 30V  
Ee (+) 0.5mW/cm2  
VCC = 5.0V, Ee (+) = 0  
RL = 330Ω  
VCC = 5.0V, Ee = 0 or  
0.5mW/cm2, f = 10kHz,  
D.C. = 50%, RL = 330Ω  
IOH  
-
-
100  
µA  
Low state output voltage  
Output rise and fall time  
VOL  
tr, tf  
-
-
-
-
0.4  
V
75  
5
-
-
ns  
µs  
Propagation delay  
tPHL, tPLH  
CLL133/CLL133W and CLL135/CLL135W (inverter, open collector)  
VCC = 5.0V, VOH = 30V  
Ee (+) = 0  
High state output current  
IOH  
-
-
100  
µA  
V
CC = 5.0V, RL = 330Ω  
Low state output voltage  
Output rise and fall time  
VOL  
tr, tf  
-
-
-
0.4  
-
V
Ee (+) 0.5mW/cm2  
VCC = 5.0V, Ee = 0 or  
0.5mW/cm2, f = 10kHz,  
D.C. = 50%, RL = 330Ω  
75  
ns  
Propagation delay  
tPHL, tPLH  
-
5
-
µs  
NOTE: Due to the high sensitivity of the CLL series, when used in high speed switching  
applications, Clairex recommends installing a 0.1µF capacitor between VCC and GND.  
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.  
Page 4 of 4  
Clairex Technologies, Inc.  
Phone: 972-265-4900  
1301 East Plano Parkway  
Fax: 972-265-4949  
Plano, Texas 75074-8524  
www.clairex.com  

相关型号:

CLL131

Photo-IC Sensors Digital Output
CLAIREX

CLL131W

Photo-IC Sensors Digital Output
CLAIREX

CLL133

Photo-IC Sensors Digital Output
CLAIREX

CLL133W

Photo-IC Sensors Digital Output
CLAIREX

CLL134

Photo-IC Sensors Digital Output
CLAIREX

CLL134W

Photo-IC Sensors Digital Output
CLAIREX

CLL135

Photo-IC Sensors Digital Output
CLAIREX

CLL135W

Photo-IC Sensors Digital Output
CLAIREX

CLL136

Photo-IC Sensors Digital Output
CLAIREX

CLL136W

Photo-IC Sensors Digital Output
CLAIREX

CLL137

Photo-IC Sensors Digital Output
CLAIREX

CLL137W

Photo-IC Sensors Digital Output
CLAIREX