ML612PND153MLF [COILCRAFT]
General Purpose Inductor,;型号: | ML612PND153MLF |
厂家: | Coilcraft lnc. |
描述: | General Purpose Inductor, |
文件: | 总3页 (文件大小:352K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
1278COUPLEDINDUCTORS
Return to menu
High Reliability Coupled Inductors ML612PND
The ML612PND series of coupled inductors was designed
for high temperature applications – up to 155°C. The
excellent coupling coefficient (k ≥ 0.98) makes it ideal
for use in SEPIC applications. In SEPIC topologies, the
required inductance for each winding in a coupled induc-
tor is half the value needed for two separate inductors,
allowing selection of a part with lower DCR and higher
current handling.
These inductors provide high inductance, high efficiency,
excellent current handling and 500 V isolation in a very
rugged part. They are well suited for use as VRM induc-
tors in high-current DC-DC and VRM/VRD controllers.
They can also be used as two single inductors connected
in series or parallel, as a common mode choke or as a
1:1 transformer.
D1
+
+
L1
Q1
C1
+
V
V
OUT
L2
C2
Load
IN
–
–
Typical SEPIC schematic
Refer to Application Note, Document 639,
“Selecting Coupled Inductors for SEPIC Applications”
Core material Ferrite
Core and winding loss Go to online calculator
Terminations Matte tin over nickel over phos bronze.
Weight: 3.8 g – 4.6 g
Ambient temperature –55°C to +105°C with Irms current
Maximum part temperature +155°C (ambient + temp rise).
Storage temperature Component: –55C to +155°C.
Tape and reel packaging: –55°C to +80°C
Resistance to soldering heat Max three 40 second reflows at
+260°C, parts cooled to room temperature between cycles
Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C /
85% relative humidity)
inches
mm
Dimensions are in
Winding-to-winding and winding-to-core isolation 500 Vrms
Enhanced crush-resistant packaging 500/13″ reel;
Plastic tape: 24 mm wide, 0.4 mm thick, 16 mm pocket spacing,
8.1 mm pocket depth
Document ML704-1 Revised 05/30/17
This product may not be used in medical or high
Fax 847-639-1508
Email cps@coilcraft.com Specifications subject to change without notice.
www.coilcraft-cps.com Please check our web site for latest information.
risk applications without prior Coilcraft approval.
1102 Silver Lake Road
Cary, IL 60013
Phone 800-981-0363
© Coilcraft, Inc. 2017
1278COUPLEDINDUCTORS
ML612PND Series (1278)
Isat(A)5
Irms(A)
both one
windings6 winding7
Coupling Leakage
coefficient Ltyp
SRF(MHz)4
Inductance2 DCRmax3
10%
20%
30%
Partnumber1
(µH)
(Ohms)
min
typ
typ
(µH)
drop drop drop
ML612PND472MLZ
ML612PND562MLZ
ML612PND682MLZ
ML612PND822MLZ
ML612PND103MLZ
4.7 20%
5.6 20%
6.8 20%
8.2 20%
0.040
0.046
0.048
0.055
0.058
26.0
24.0
18.0
16.0
14.0
33.0
30.0
23.0
20.0
17.0
0.98
0.98
0.98
0.98
0.98
0.22 13.90 15.20 16.36
0.23 13.38 14.86 15.74
0.22 12.10 13.56 14.20
0.34 10.30 11.52 12.20
3.16
2.87
2.81
2.76
2.56
4.47
4.06
3.98
3.90
3.62
10
20%
0.34
8.80 10.00 10.66
ML612PND123MLZ
ML612PND153MLZ
ML612PND183MLZ
ML612PND223MLZ
ML612PND273MLZ
12
15
18
22
27
20%
20%
20%
20%
20%
0.062
0.072
0.080
0.096
0.120
12.0
10.0
9.6
8.8
8.0
15.0
13.0
12.0
11.0
10.0
0.98
0.99
0.99
0.99
0.99
0.36
0.41
0.37
0.41
0.43
8.20
7.40
6.50
6.00
5.80
9.18
8.36
7.38
6.80
6.56
9.74
9.03
7.86
7.26
7.02
2.48
2.30
2.18
1.99
1.78
3.50
3.25
3.08
2.81
2.52
ML612PND333MLZ
ML612PND393MLZ
ML612PND473MLZ
ML612PND563MLZ
ML612PND683MLZ
33
39
47
56
68
20%
20%
20%
20%
20%
0.150
0.161
0.180
0.190
0.210
7.6
6.8
6.0
5.6
5.2
9.5
8.5
7.5
7.0
6.5
0.99
0.99
0.99
0.99
0.99
0.56
0.64
0.70
0.76
0.88
5.50
4.70
3.70
3.60
3.50
6.10
5.26
4.34
4.18
4.04
6.52
5.60
4.60
4.50
4.32
1.59
1.54
1.45
1.41
1.35
2.25
2.18
2.05
2.00
1.90
ML612PND823MLZ
ML612PND104MLZ
ML612PND124KLZ
ML612PND154KLZ
ML612PND184KLZ
82
100
120
150
180
20%
20%
10%
10%
10%
0.280
0.300
0.410
0.460
0.510
4.0
3.6
3.4
3.3
3.2
5.0
4.5
4.3
4.1
4.0
0.99
>0.99
0.99
>0.99
>0.99
0.85
0.90
1.31
1.46
0.93
3.30
2.80
2.60
2.20
2.10
3.72
3.24
2.94
2.54
2.42
4.02
3.46
3.16
2.70
2.58
1.16
1.13
0.96
0.91
0.86
1.65
1.59
1.36
1.29
1.22
ML612PND224KLZ
ML612PND274KLZ
ML612PND334KLZ
ML612PND394KLZ
ML612PND474KLZ
220
270
330
390
470
10%
10%
10%
10%
10%
0.690
0.900
1.02
1.12
1.53
2.7
2.5
2.3
2.2
1.8
3.4
3.1
2.9
2.7
2.2
>0.99
>0.99
0.99
>0.99
>0.99
1.54
1.17
4.14
1.64
0.25
1.90
1.70
1.50
1.40
1.30
2.16
1.94
1.70
1.60
1.50
2.28
2.10
1.84
1.70
1.60
0.74
0.65
0.61
0.58
0.50
1.05
0.92
0.86
0.82
0.70
ML612PND564KLZ
ML612PND684KLZ
ML612PND824KLZ
560
680
820
10%
10%
10%
10%
1.69
2.29
2.55
2.87
1.6
1.4
1.1
1.0
2.0
1.7
1.4
1.3
>0.99
>0.99
>0.99
>0.99
2.68
2.11
2.39
4.28
1.20
1.00
0.900 1.04
1.34
1.08
1.46
1.22
1.18
0.47
0.41
0.39
0.37
0.67
0.58
0.55
0.52
ML612PND105KLZ 1000
0.850 0.948 1.05
1. When ordering, please specify testing code:
Coupled Inductor Core and Winding Loss Calculator
This web-based utility allows you to enter frequency, peak-to-peak
(ripple) current, and Irms current to predict temperature rise and
overall losses, including core loss. Go to online calculator.
ML612PND105KLZ
Testing: Z = Unscreened
H = Group A screening per Coilcraft CP-SA-10001
T = Screening per MIL-STD-981
U = Screening per EEE-INST-002
F = Screening per ESCC 3201
All screening performed to the document’s latest revision
Custom screening also available
2. Inductance shown for each winding, measured at 100 kHz, 0.1 Vrms, 0
Adc on an Agilent/HP 4284A LCR meter or equivalent.When leads are
connected in parallel, inductance is the same value.When leads are
connected in series, inductance is four times the value.
3. DCR is for each winding.When leads are connected in parallel, DCR
is half the value.When leads are connected in series, DCR is twice the
value.
4. SRF measured using an Agilent/HP 4191A or equivalent.When leads
are connected in parallel, SRF is the same value.
5. DC current at 25°C that causes the specified inductance drop from its
value without current. It is the sum of the current flowing in both wind-
ings.
6. Equal current when applied to each winding simultaneously that
causes a 40°C temperature rise from 25°C ambient. See temperature
rise calculation.
7. Maximum current when applied to one winding that causes a 40°C
temperature rise from 25°C ambient. See temperature rise calculation.
8. Electrical specifications at 25°C.
Refer to Doc 639 “Selecting Coupled Inductors for SEPIC Applications.”
Refer to Doc 362 “Soldering Surface Mount Components” before soldering.
Document ML704-2 Revised 05/30/17
This product may not be used in medical or high
Fax 847-639-1508
Email cps@coilcraft.com Specifications subject to change without notice.
www.coilcraft-cps.com Please check our web site for latest information.
risk applications without prior Coilcraft approval.
1102 Silver Lake Road
Cary, IL 60013
Phone 800-981-0363
© Coilcraft, Inc. 2017
1278COUPLEDINDUCTORS
ML612PND Series (1278)
Typical L vs Current
Typical L vs Frequency
10000
10000
1000 µH
470 µH
1000 µH
1000
1000
470 µH
100 µH
100
100 µH
47 µH
100
10
47 µH
10 µH
4.7 µH
10 µH
10
4.7 µH
1
1
0.1
1
10
100
0.01
0.1
1
10
Current (A)
Frequency (MHz)
Document ML704-3 Revised 05/30/17
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Email cps@coilcraft.com Specifications subject to change without notice.
www.coilcraft-cps.com Please check our web site for latest information.
Fax 847-639-1508
1102 Silver Lake Road
Cary, IL 60013
Phone 800-981-0363
© Coilcraft, Inc. 2017
相关型号:
ML612PND154KLC
General Purpose Inductor, 150uH, 10%, 2 Element, Ferrite-Core, SMD, CHIP, 1212-78M
COILCRAFT
ML612PND154KLH
General Purpose Inductor, 150uH, 10%, 2 Element, Ferrite-Core, SMD, CHIP, 1212-78M
COILCRAFT
ML612PND183MLC
General Purpose Inductor, 18uH, 20%, 2 Element, Ferrite-Core, SMD, CHIP, 1212-78M
COILCRAFT
©2020 ICPDF网 联系我们和版权申明