FTS125-CTV-010.0 [CONNOR-WINFIELD]
GPS Disciplined Oscillators;型号: | FTS125-CTV-010.0 |
厂家: | CONNOR-WINFIELD CORPORATION |
描述: | GPS Disciplined Oscillators 全球定位系统 |
文件: | 总10页 (文件大小:875K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
125 Series
Available at Digi-Key
www.digikey.com
FTS125-CTV-010.0 MHz
GPS Disciplined Oscillators
General Description
The FTS125-CTV-010.0 MHz Frequency and Time
2111 Comprehensive Drive
Aurora, Illinois 60505
Phone: 630-851-4722
Fax: 630-851-5040
Standard module is a TCXO GPS driven, mixed-signal
phase lock loop, providing a 1 PPS CMOS output from
a Connor-Winfield GPS timing receiver and generating
a 10 MHz CMOS and a 10 MHz SINE output from an
intrinsically low jitter voltage controlled crystal oscillator.
The FTS125 can lock to a 10 MHz reference derived
www.conwin.com
from the on-board GPS receiver or an external 10 MHz
reference or to an external 1 PPS reference. Alarms
are provided to indicate Loss-of-Lock, Holdover, and
Antenna Fault. The on-board GPS receiver requires an
outdoor mounted GPS antenna for the best stability and
consistent performance.
D
A
T
A
The mode control inputs are used to manually
switch between references and/or holdover. The user
application should monitor the alarm outputs and manually switch modes as needed.
Serial I/O lines provide access to the NMEA messages from the GPS receiver
(referenced in the Connor-Winfield’s Wi125 User Manual. Contact Connor-Winfield Sales
for a copy). The serial I/O lines can be used to access GPS timestamp information, or to
verify that the receiver has recovered from an alarm condition. The reset is used to reset
the GPS receiver (if needed).
S
H
E
E
T
Features
•ꢀPhaseꢀlockedꢀ10ꢀMHzꢀoutput
•ꢀ1ꢀPPSꢀoutput
•ꢀ3ꢀselectableꢀreferences:ꢀGPS,ꢀExternalꢀ10ꢀMHzꢀorꢀExternalꢀ1ꢀPPS
•ꢀHoldover
•ꢀThreeꢀalarmꢀoutputs.ꢀ(Loss-of-Lock,ꢀHoldoverꢀandꢀAntennaꢀFault)
•ꢀSerialꢀinputꢀandꢀoutputꢀportsꢀ(GPSꢀreceiver)
•ꢀMasterꢀresetꢀ
•ꢀ+3.3ꢀVoltꢀpowerꢀsupplyꢀ
•ꢀCommercialꢀTempꢀ(0-70°ꢀC)
•ꢀMeetsꢀITU-TꢀG.811ꢀWanderꢀGenerationꢀMask
•ꢀMeetsꢀETSI-PRCꢀWanderꢀGenerationꢀMaskꢀ(withꢀOCXOꢀreference)
•ꢀMCXꢀGPSꢀAntennaꢀConnection
•ꢀFixedꢀPositionꢀUnit
•ꢀPackage:ꢀ32-pinꢀThrough-Hole
•ꢀPhysicalꢀDimensions:ꢀ4.15”ꢀxꢀ3.3”ꢀxꢀ0.718”ꢀ(105.41mmꢀxꢀ83.82mmꢀxꢀ18.22mm)
Bulletin
SG185
Revision
02
Date
03 Jan 12
Issued By
ENG
Functional Block Diagram
Figure 1
OCXO
or
TCXO
FTS125 Module
REFERENCE
SERIAL OUTPUT (A, B, C)
HOLDOVER STATUS
LOCK STATUS
MCX
Connector
Wi125
ANTENNNA FAULT STATUS
1 PPS CMOS OUTPUT
BOOT SEL
(GPS Receiver)
SERIAL IN
(A, B, C)
33Ω
1 PPS
GPS REF
10 MHz REF
1 PPS REF
LOW JITTER
VCXO
or
DPFD
ANALOG
FILTER
CPLD
RESET
OCVCXO
SYNC 1 CONTROL
SYNC 2 CONTROL
DISABLE
1 / N
10 MHz CMOS
OUTPUT
DRIVER
33Ω
DRIVER
&
TRANSLATION
10 MHz SINE
OUTPUT
JTAG
(Programming Only)
FTS125-CTV Data Sheet #: SG185
Page 2
Rev: 02
Date: 01/03/12
© Copyright 2012 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice
Typical Application
Figure 2
FTS125-CTV Data Sheet #: SG185 Page 3
Rev: 02
Date: 01/03/12
© Copyright 2012 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice
Pin Description
Table 1
Pin #
Pin Name
TXCꢀ
Description
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
1ꢀ
2ꢀ
3ꢀ
4ꢀ
5ꢀ
6ꢀ
7ꢀ
RS-232ꢀcommunicationꢀtransmitꢀsignalꢀforꢀUART2ꢀ(Optional)
RS-232ꢀcommunicationꢀtransmitꢀsignalꢀforꢀUART1ꢀ(Optional)
RS-232ꢀcommunicationꢀtransmitꢀsignalꢀforꢀUART0ꢀ(Optional)
ꢀ
TXBꢀ
TXAꢀ
GNDꢀ
RXCꢀ
RS-232ꢀcommunicationꢀreceiveꢀsignalꢀforꢀUART2ꢀ(Optional)
RS-232ꢀcommunicationꢀreceiveꢀsignalꢀforꢀUART1ꢀ(Optional)
RS-232ꢀcommunicationꢀreceiveꢀsignalꢀforꢀUART0ꢀ(Optional)
RXBꢀ
RXAꢀ
ꢀ
ꢀ
8ꢀ
ꢀ
*Bootselꢀ
ꢀ
NormallyꢀHIGHꢀ-ꢀOnlyꢀpulledꢀlowꢀforꢀRS-232ꢀre-programmingꢀofꢀGPSꢀsoftware.ꢀꢀ
Defaultꢀstateꢀisꢀpulledꢀhighꢀinternally.
ꢀ
9ꢀ
10ꢀMHzꢀRefꢀInputꢀ
ExternalꢀLVCMOSꢀ10ꢀMHzꢀreferenceꢀ(Optional).ꢀDefaultꢀstateꢀisꢀpulledꢀhighꢀinternally.
ꢀ
ꢀ
10ꢀ
ꢀ
*Resetꢀ
ꢀ
HardwareꢀResetꢀforꢀtheꢀGPSꢀtimingꢀcircuitry.ꢀPullꢀlowꢀtoꢀreset.ꢀDefaultꢀstateꢀisꢀpulledꢀꢀ
highꢀinternally.
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
11ꢀ
12ꢀ
13ꢀ
14ꢀ
15ꢀ
16ꢀ
17ꢀ
18ꢀ
GNDꢀ
1ꢀPPSꢀRefꢀInputꢀ
GNDꢀ
ꢀ
ExternalꢀLVCMOSꢀ1ꢀPPSꢀreferenceꢀ(Optional).ꢀDefaultꢀstateꢀisꢀpulledꢀhighꢀinternally.
ꢀ
AntennaꢀSupplyꢀVoltageꢀ
GNDꢀ
AntennaꢀSupplyꢀVoltage.ꢀLimitꢀcontinuousꢀcurrentꢀtoꢀ45mAꢀMax.
ꢀ
VCC1ꢀ
SupplyꢀvoltageꢀforꢀGPSꢀtimingꢀcircuitry.
VCC2ꢀ
Supplyꢀvoltageꢀforꢀnoiseꢀclean-upꢀandꢀinterfacingꢀcircuitry.ꢀꢀ
ꢀ
GNDꢀ
ꢀ
ꢀ
19ꢀ
ꢀ
SYNC1ꢀControlꢀ
ꢀ
Lockꢀmodeꢀcontrolꢀsignalꢀ1.ꢀSeeꢀTableꢀ4ꢀforꢀfunctionalꢀdescription.ꢀꢀ
Defaultꢀstateꢀisꢀpulledꢀhighꢀinternally.
ꢀ
ꢀ
20ꢀ
ꢀ
SYNC2ꢀControlꢀ
ꢀ
Lockꢀmodeꢀcontrolꢀsignalꢀ2.ꢀSeeꢀTableꢀ4ꢀforꢀfunctionalꢀdescription.ꢀꢀ
Defaultꢀstateꢀisꢀpulledꢀhighꢀinternally.
ꢀ
ꢀ
21ꢀ
ꢀ
*Disableꢀ
ꢀ
Open/Highꢀ=ꢀenabledꢀoutputs.ꢀPullꢀlowꢀtoꢀdisableꢀtheꢀ10ꢀMHzꢀCMOSꢀandꢀSINEꢀoutputs.ꢀꢀ
Defaultꢀstateꢀisꢀpulledꢀhighꢀinternally.
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
22ꢀ
23ꢀ
24ꢀ
25ꢀ
26ꢀ
27ꢀ
28ꢀ
29ꢀ
30ꢀ
31ꢀ
32ꢀ
Unusedꢀ
HoldoverꢀStatusꢀ
LockꢀStatusꢀ
ꢀ
Highꢀ=ꢀUnitꢀisꢀinꢀHoldover
Highꢀ=ꢀUnitꢀisꢀlockedꢀtoꢀselectedꢀreference.
AntennaꢀFaultꢀStatusꢀ
1ꢀPPSꢀCMOSꢀOutputꢀ
GNDꢀ
Highꢀ=ꢀAꢀfaultꢀhasꢀbeenꢀdetectedꢀonꢀPinꢀ14ꢀ(AntennaꢀSupplyꢀVoltage)
1ꢀPPSꢀCMOSꢀoutputꢀprovidedꢀbyꢀtheꢀWi125
ꢀ
10ꢀMHzꢀCMOSꢀOutputꢀ
Unusedꢀ
10ꢀMHzꢀlowꢀjitterꢀCMOSꢀoutput
ꢀ
Unusedꢀ
ꢀ
GNDꢀ
ꢀ
10ꢀMHzꢀSINEꢀOutputꢀ
10ꢀMHzꢀACꢀcoupledꢀlowꢀjitterꢀSINEꢀoutput
FTS125-CTV Data Sheet #: SG185
Page 4
Rev: 02
Date: 01/03/12
© Copyright 2012 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice
Absolute Maximum Rating
Table 2
Symbol
Parameter
PowerꢀSupplyꢀVoltageꢀ
InputꢀVoltageꢀ
Minimum
-0.3ꢀ
Maximum
3.7ꢀ
Units
Voltsꢀ
Voltsꢀ
Voltsꢀ
°Cꢀ
Notes
VCC
ꢀ
1
1
1
1
VINꢀ
-0.3ꢀ
4.6ꢀ
VPREAMP
ꢀ
AntennaꢀSupplyꢀVoltageꢀ
StorageꢀTemperatureꢀ
2.7ꢀ
13.2ꢀ
80ꢀ
TSꢀ
-30ꢀ
Operating Specifications
Table 3
Symbol
VCC1ꢀ
ICC1ꢀ
Parameter
SupplyꢀVoltageꢀ1ꢀ
Minimum
Nominal
3.3ꢀ
.200ꢀ
3.3ꢀ
.038ꢀ
ꢀ
Maximum
Units
Vꢀ
Notes
ꢀ
3.135ꢀ
3.465ꢀ
SupplyꢀCurrentꢀ1ꢀwithꢀTCXOꢀ ꢀ
SupplyꢀVoltageꢀ2ꢀ
SupplyꢀCurrentꢀ2ꢀwithꢀVCXO/TCVCXOꢀ
ꢀ
.300ꢀ
Aꢀ
VCC2ꢀ
ICC2ꢀ
ꢀ
3.135ꢀ
3.465ꢀ
Vꢀ
2
ꢀ
0ꢀ
30ꢀ
ꢀ
.060ꢀ
A
TOꢀ
TemperatureꢀRangeꢀ
ꢀ
ꢀ
ꢀ
70ꢀ
°C
tJTOL
tAQ_GPSꢀ
tAQ_EXT
ꢀ
InputꢀJitterꢀToleranceꢀ
GPSꢀInputꢀAcquisitionꢀTimeꢀ
ꢀ
ꢀ
nsꢀ
secꢀ
secꢀ
120ꢀ
90ꢀ
ꢀ
ꢀ
3
3
ꢀ
ExternalꢀInputꢀAcquisitionꢀTimeꢀ
ꢀ
Oscillator Performance
VCXO (CTV))
50ꢀppm
PLL Option:
FCAP Capture/Pull-inꢀRangeꢀ
JitterꢀFilterꢀBandwidthꢀ
DutyꢀCycleꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
FBWꢀ
DCꢀ
6ꢀHzꢀTyp.
ꢀ
45/55%
RMSꢀ
ꢀ
ꢀ
RMSꢀPhaseꢀNoiseꢀ
10ꢀHzꢀ-ꢀ2ꢀMHzꢀꢀ
12ꢀkHzꢀ-ꢀ2ꢀMHzꢀ
ꢀ
ꢀ
ꢀ
ꢀ
20ꢀpsꢀTyp.ꢀ
0.5ꢀpsꢀTyp.
Holdover/Wander Generation Performance
4
5
Reference Option:
TSTA TemperatureꢀStabilityꢀ
Int TCXO (CTV)
0.5ꢀppmꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
VSTAꢀ
AYEARLYꢀ
ꢀ
VccꢀStabilityꢀ
YearlyꢀAgingꢀ
ꢀ
ꢀ
0.1ꢀppmꢀ
2ꢀppm
WanderꢀGenerationꢀSpecificationꢀ
ITU-TꢀG.811
NOTES:
1. Stresses beyond those listed under “Absolute Maximum Rating” may cause permanent damage to the module.These are stress ratings only and functional operation of the device at these or any other
conditions beyond those indicated under “Operating Specifications” is not implied. Exposure to absolute maximum rated conditions for extended periods may affect device reliability.
2. Requires external regulation and supply decoupling.
3. Cold Power-up.
4. Holdover will be re-calculated with each successful lock.Yearly aging represents 1 continuous year in Holdover.
5. Relative to 25°C.
FTS125-CTV Data Sheet #: SG185 Page 5
Rev: 02
Date: 01/03/12
© Copyright 2012 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice
Mode Control Table
Table 4
SYNC 1 SYNC 2
Operating Mode
ꢀ
ꢀ
ꢀ
ꢀ
0ꢀ
0ꢀ
1ꢀ
1ꢀ
0ꢀ
1ꢀ
0ꢀ
1ꢀ
ForceꢀHoldover
LockꢀtoꢀExternalꢀ10ꢀMHzꢀreference*
LockꢀtoꢀExternalꢀ1ꢀPPSꢀreference
(Default)ꢀLockꢀtoꢀGPSꢀSignal
* Note: Holdover is not supported in this mode; loss of the 10MHz reference will rail the
PLL output until the reference returns or another mode is selected.
Input And Output Characteristics
Table 5
LVCMOS Inputs and Outputs
Symbol
VIHꢀ
Parameter
Minimum
Maximum
Units
V
V
Notes
HighꢀLevelꢀInputꢀVoltageꢀ
LowꢀLevelꢀInputꢀVoltageꢀ
HighꢀLevelꢀOutputꢀVoltageꢀ
LowꢀLevelꢀOutputꢀVoltageꢀ
OutputꢀCapacitanceꢀ
1.7ꢀ
4.0ꢀ
0.8ꢀ
ꢀ
VILꢀ
-0.5ꢀ
VOH
ꢀ
2.4ꢀ
V
VOLꢀ
COꢀ
ꢀ
0.4ꢀ
10ꢀ
V
ꢀ
pF
10 MHz Sine Output
Symbol
Parameter
Loadꢀ
Typical
50ꢀ
Units
ohms
dBmꢀ
%
Notes
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
OutputꢀPowerꢀ
TotalꢀHarmonicꢀDistortionꢀ
9ꢀ
ꢀ
2.2ꢀ
GPS Receiver Specifications
Table 6
Parameter
Specifications
Notes
Acquisition/TrackingꢀSensitivityꢀ
-155dBm/-156dBm
AcquisitionꢀTime:
ꢀ
HotꢀStartꢀw/ꢀNetworkꢀAssistꢀꢀ Outdoor:ꢀ<2ꢀsecꢀꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Indoor:ꢀ(-148dBm)ꢀ<5ꢀsecꢀ
ꢀ
ꢀ
ꢀ
ꢀ
StandꢀAloneꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Cold:ꢀ<45ꢀsecꢀꢀ
Warm:ꢀ<38ꢀsecꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Hot:ꢀ<5ꢀsecꢀ
ꢀ
Re-acquisition:ꢀ<1secꢀ(90%ꢀconfidence)
SupportedꢀProtocolsꢀ
ꢀ
NetworkꢀAssist,ꢀNMEAꢀ0183
Reset Generation (I/O pin 10 - RESET)
The power-on-reset for the FTS125 is generated on-board. If it is desired to extend the power-on-reset signal or provide a manual
reset of the GPS receiver, pull this signal low.
FTS125-CTV Data Sheet #: SG185
Page 6
Rev: 02
Date: 01/03/12
© Copyright 2012 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice
Antenna Requirements
Table 7
Parameter
Notes
TheꢀFTS125ꢀantennaꢀconnectorꢀisꢀanꢀMCXꢀ(female)
TheꢀantennaꢀsupplyꢀvoltageꢀprovidedꢀtoꢀPinꢀ14ꢀmustꢀbeꢀwithinꢀtheꢀrangeꢀofꢀ2.7ꢀtoꢀ13.2Vꢀ(AMR);ꢀꢀ
theꢀantennaꢀmustꢀbeꢀableꢀtoꢀoperateꢀatꢀthisꢀvoltage
Theꢀantenna’sꢀcontinuousꢀcurrentꢀdrawꢀmustꢀbeꢀ<=45mA
Theꢀantennaꢀmustꢀhaveꢀaꢀfullꢀskyꢀviewꢀforꢀoptimalꢀreceiverꢀperformance
Anꢀactiveꢀantennaꢀwithꢀaꢀminimumꢀ10dBꢀgainꢀ(includingꢀcableꢀloss)ꢀshouldꢀbeꢀused
Standard 125 Series models are designed for fixed position operation only. Contact Connor-Winfield Sales for mobile application model offerings
Phase Noise
Figure 3
Phase Noise:
Oꢀ ffsetꢀFrequencyꢀ(Hz))ꢀ
CTVꢀ(dBc/Hz)
-70
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
10ꢀ
100ꢀ
1kꢀ
-105
-135
10kꢀ
100kꢀ
1Mꢀ
-145
-152
-158
FTS125-CTV Data Sheet #: SG185 Page 7
Rev: 02
Date: 01/03/12
© Copyright 2012 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice
Allan Variance – CTV
Figure 4
Wander Generation Plot – CTV versus G.811 Wander Generation Mask
Figure 5
100,000
10,000
1,000
100
10
1
0.01
0.10
1.00
10.00
100.00
1,000.00
10,000.00
100,000.00
1,000,000.00
Observation Interval (sec)
FTS125-CTV Data Sheet #: SG185
Page 8
Rev: 02
Date: 01/03/12
© Copyright 2012 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice
Soldering and Cleaning Recommendations
Hand solder, leaded wave solder, and lead-free wave solder processes are recommended for attaching the FTS125 after reflow
processes are complete. Since the FTS125 does not have hermetic enclosure, hand cleaning the leads is recommended and the
module should not be completely immersed.
Package Dimensions
Figure 6
Recommended Footprint Dimensions
Figure 7
0.038"
Hole
Thru All
x32
0.065"
Pad
x32
FTS125
Dimensions
and
Keepout Area
Top View
FTS125-CTV Data Sheet #: SG185 Page 9
Rev: 02
Date: 01/03/12
© Copyright 2012 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice
Available at Digi-Key
www.digikey.com
2111 Comprehensive Drive
Aurora, Illinois 60505
Phone: 630-851-4722
Fax: 630-851-5040
www.conwin.com
Ordering Information
Ex: FTS125-COO-010.0MHz
FTS125
C
O
O
-010.0M
Temp Range
Cꢀ=ꢀ0-70°Cꢀꢀꢀ
Wi125 Reference
Tꢀ=ꢀTCXOꢀ
PLL Oscillator
Vꢀ=ꢀVCXO
Output Frequency
ꢀꢀ
* CTO Option is not available
Revision Date
Note
00ꢀ
01ꢀ
02ꢀ
10/28/10ꢀ
FTS125-CTVꢀforꢀPublicꢀRelease
05/27/11ꢀ
01/03/12ꢀ
BlockꢀDiagramꢀupdatedꢀwithꢀWi125ꢀReceiverꢀ&ꢀSolderingꢀRecommendations
AddedꢀPackageꢀ&ꢀDimensionꢀInformationꢀtoꢀFeatures
相关型号:
FTS15P0G1
D Subminiature Connector, 15 Contact(s), Male, Solder Terminal, Plug, ROHS COMPLIANT
MOLEX
FTS15P0G2
D Subminiature Connector, 15 Contact(s), Male, Solder Terminal, Plug, ROHS COMPLIANT
MOLEX
FTS15P0RG1
D Subminiature Connector, 15 Contact(s), Male, Solder Terminal, Plug, ROHS COMPLIANT
MOLEX
FTS15P0SG1
D Subminiature Connector, 15 Contact(s), Male, Solder Terminal, Plug, ROHS COMPLIANT
MOLEX
FTS15P0SG2
D Subminiature Connector, 15 Contact(s), Male, Solder Terminal, Plug, ROHS COMPLIANT
MOLEX
FTS15P0SG3
D Subminiature Connector, 15 Contact(s), Male, Solder Terminal, Plug, ROHS COMPLIANT
MOLEX
FTS15P14G1
D Subminiature Connector, 15 Contact(s), Male, Solder Terminal, Plug, ROHS COMPLIANT
MOLEX
FTS15P14G2
D Subminiature Connector, 15 Contact(s), Male, Solder Terminal, Plug, ROHS COMPLIANT
MOLEX
FTS15P14G3
D Subminiature Connector, 15 Contact(s), Male, Solder Terminal, Plug, ROHS COMPLIANT
MOLEX
©2020 ICPDF网 联系我们和版权申明