170M5495 [COOPER]

Electric Fuse, 550A, 1300VAC, 100000A (IR), Inline/holder,;
170M5495
型号: 170M5495
厂家: COOPER BUSSMANN, INC.    COOPER BUSSMANN, INC.
描述:

Electric Fuse, 550A, 1300VAC, 100000A (IR), Inline/holder,

电路保护
文件: 总4页 (文件大小:275K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
High Speed Fuses  
Square body flush end contact — 1250V/1300V (IEC/UL):  
50-1400A  
3
2.5  
Arc Voltage  
1250V/1300V (IEC/UL) 50-1400A  
U
L
This curve gives the peak  
Specifications  
Description: Square body flush  
end contact high speed fuses.  
arc voltage, U , which may 1.8  
L
1.4  
appear across the fuse  
during its operation as a  
function of the applied  
working voltage, E , (rms)  
at a power factor of 15%.  
103  
8
Dimensions: See dimensions  
illustrations.  
6
5
g
Ratings:  
Volts:1250Vac (IEC)  
— 1300Vac (UL)  
4
3
Eg  
Power Losses  
400 600  
800 1000 1200 1400  
Watts loss at rated current  
is given in the electrical  
characteristics. The curve  
allows the calculation of  
the power losses at load  
currents lower than the  
rated current. The correc-  
Amps:50-1400A  
IR:100kA RMS Sym.  
1.0  
0.8  
Kp  
Agency Information: CE, Designed and tested to IEC  
60269: Part 4, UL Recognized. Consult Cooper Bussmann for  
UL Recognition/CSA Component Acceptance status.  
0.6  
0.5  
0.4  
0.3  
Electrical Characteristics  
Total Clearing I2t  
tion factor, K , is given as  
p
0.2  
a function of the RMS load  
1.5  
1.25  
1.0  
current, I , in % of the  
2
b
The total clearing I t at rated  
voltage and at power factor  
of 15% are given in the elec-  
trical characteristics. For  
K
Ib  
rated current.  
0.1  
30 40 50 60  
80 90 100%  
70  
Features and Benefits  
• Excellent dc performance  
other voltages, the clearing  
2
0.5  
0.4  
• Low arc voltage and low energy let-through (I t)  
• Low watts loss  
2
I t is found by multiplying by  
correction factor, K, given as  
a function of applied working  
0.3  
• Superior cycling capability  
0.2  
voltage, E , (rms).  
Typical Applications  
• DC common bus  
• DC drives  
• Power converters/rectifiers  
• Reduced voltage starters  
g
Eg  
400 600 800 1000 1200 1400  
Dashed lines (- - - - - -) apply to the  
following amperages:.  
Size  
1*  
1
Amps.  
400A  
500-630A  
630-1000A  
800-1400A  
2
3
Dimensions (mm)  
Type -BKN/-, -GKN/-  
Size Type  
A
B
D
E
F
M8  
M8  
M8  
F** (in)  
G
5
5
8
8
H
5
B
1*  
1*  
1
BKN + GKN/75 74  
BKN/80 80  
BKN + GKN/75 74  
BKN/80 80  
75  
81  
75  
81  
75  
81  
91  
76  
83  
91  
59  
59  
69  
69  
77  
77  
77  
92  
92  
92  
45  
45  
53  
53  
61  
61  
61  
76  
76  
76  
16” - 18 UNC-2B  
Ø17  
Ø17  
Ø20  
Ø20  
5
16” - 18 UNC-2B  
1
2
2
2
3
3
3
M8  
3
BKN + GKN/75 74  
BKN/80 80  
BKN + GKN/90 80  
BKN + GKN/75 74  
BKN/80 81  
M10  
M10  
M10  
M12  
M12  
M12  
8
” - 16 UNC-2B  
10 Ø24  
10 Ø24  
10 Ø24  
10 Ø30  
10 Ø30  
10 Ø30  
3
8
” - 16 UNC-2B  
1
2
” - 13 UNC-2B  
1
BKN + GKN/90 81  
2
” - 13 UNC-2B  
**Valid for fuses type -GKN/-.  
1mm = 0.0394” / 1” = 25.4mm  
D
A
E
F
E
H
G
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp  
159  
High Speed Fuses  
Square body flush end contact — 1250V/1300V (IEC/UL):  
50-1400A  
Catalog Numbers  
Catalog Numbers  
Electrical Characteristics  
I2t (A2 Sec)  
-BKN/75  
-BKN/80  
Type K  
-BKN/90  
Type K  
-GKN/75  
Type K  
-GKN/90  
Type K  
Rated  
Current  
Type K  
Indicator  
for Micro  
170M3388  
170M3389  
170M3390  
170M3391  
170M3392  
170M3393  
170M3394  
170M3395  
170M3396  
170M3397  
Indicator  
for Micro  
170M3438  
170M3439  
170M3440  
170M3441  
170M3442  
170M3443  
170M3444  
170M3445  
170M3446  
170M3447  
170M3448  
170M4438  
170M4439  
170M4440  
170M4441  
170M4442  
170M4443  
170M4444  
Indicator  
for Micro  
Indicator  
for Micro  
170M3488  
170M3489  
170M3490  
170M3491  
170M3492  
170M3493  
170M3494  
170M3495  
170M3496  
170M3497  
Indicator  
for Micro  
RMS-  
Size Amps  
Clearing  
at 1000V  
815  
1300  
2500  
4450  
9000  
16000  
31000  
54500  
115000  
165000  
265000  
11500  
22500  
46000  
Clearing  
at 1250V  
1100  
Watts  
Loss  
15  
20  
25  
30  
35  
40  
45  
55  
60  
65  
70  
45  
50  
60  
65  
70  
75  
80  
85  
95  
100  
65  
70  
75  
80  
85  
90  
95  
100  
110  
115  
120  
125  
135  
85  
Pre-arc  
135  
1*  
50  
63  
80  
215  
420  
750  
1450  
2600  
5150  
9200  
18500  
27000  
53000  
1900  
1750  
3350  
5950  
100  
125  
160  
200  
250  
315  
350  
400  
160  
200  
250  
315  
350  
400  
450  
500  
550  
630  
250  
280  
315  
350  
400  
450  
500  
550  
630  
700  
800  
†900  
†1000  
315  
350  
400  
450  
500  
550  
630  
700  
800  
900  
1000  
1100  
†1250  
11500  
21000  
41000  
73000  
150000  
220000  
335000  
15500  
30000  
61500  
120000  
165000  
235000  
335000  
435000  
590000  
170M4388  
170M4389  
170M4390  
170M4391  
170M4392  
170M4393  
170M4394  
†170M4395 170M4445  
‡170M4396 170M4446  
‡170M4397 †170M4447  
170M5388  
170M5389  
170M5390  
170M5391  
170M5392  
170M5393  
170M5394  
170M5395  
170M4488  
170M4489  
170M4490  
170M4491  
170M4492  
170M4493  
170M4494  
†170M4495  
‡170M4496  
‡170M4497  
170M5588  
170M5589  
170M5590  
170M5591  
170M5592  
170M5593  
170M5594  
170M5595  
1
3800  
7750  
15000  
20000  
29500  
42000  
69500  
95000  
130000  
6500  
90000  
125000  
175000  
250000  
340000  
465000  
660000  
38500  
55500  
77500  
97500  
140000  
205000  
285000  
370000  
575000  
795000  
1200000  
1750000  
2350000  
58000  
170M5438  
170M5439  
170M5440  
170M5441  
170M5442  
170M5443  
170M5444  
170M5445  
2
51500  
74500  
9350  
13000  
16500  
23000  
34000  
48000  
62000  
115000  
160000  
245000  
360000  
480000  
9500  
13500  
19500  
31000  
39000  
55000  
83500  
115000  
205000  
305000  
450000  
575000  
810000  
105000  
135000  
180000  
270000  
380000  
495000  
730000  
1050000  
1550000  
170M5494  
170M5495  
170M5496  
170M5644  
170M5645  
†170M5396 170M5446  
†170M5596 170M5646  
‡170M5597 170M5647  
‡170M5598 170M5648  
170M5649  
‡170M5397 †170M5447 170M5497  
‡170M5398 ‡170M5448 170M5498  
170M5499  
170M5500  
170M5650  
170M6338  
170M6339  
170M6340  
170M6341  
170M6342  
170M6343  
170M6344  
170M6345  
170M6538  
170M6539  
170M6540  
170M6541  
170M6542  
170M6543  
170M6544  
170M6545  
170M6588  
170M6589  
170M6590  
170M6591  
170M6592  
170M6593  
170M6594  
170M6595  
3
77500  
110000  
160000  
245000  
310000  
435000  
665000  
940000  
1300000  
1900000  
2750000  
3600000  
81500  
90  
95  
120000  
185000  
235000  
325000  
495000  
705000  
995000  
1500000  
2150000  
2800000  
3950000  
6000000  
100  
105  
110  
115  
120  
125  
130  
135  
140  
145  
150  
170M6494  
170M6495  
¥170M6496 †170M6596 ¥170M6646  
170M6644  
170M6645  
†170M6346 170M6546  
‡170M6347 †170M6547 ¥170M6497 ‡170M6597 ¥170M6647  
‡170M6348 †170M6548 ¥170M6498 ‡170M6598 ¥170M6648  
‡170M6349 ‡170M6549 ¥170M6499 ‡170M6599 ¥170M6649  
170M6500  
170M6501  
170M6650  
170M6651  
†1400 1250000  
†Rated voltage (IEC) 1100V.  
‡Rated voltage (IEC) 1000V.  
¥Rated voltage (IEC) 1250V.  
• Watts loss provided at rated current.  
• Microswitch indicator ordered separately. See accessories on pages 179-180.  
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp  
160  
High Speed Fuses  
Square body flush end contact — 1250V/1300V (IEC/UL):  
50-1400A  
Size 1* — 50-400A:1250V  
Time-Current Curve  
Size 1 — 160-630A: 1250V  
Time-Current Curve  
104  
103  
102  
A
A
101  
100  
10–1  
10–2  
10–3  
1x10–4  
1x102  
103  
104  
105  
Prospective Current In Amperes RMS  
Peak Let-Through Curve  
Peak Let-Through Curve  
105  
105  
B
B
630A  
500A  
550A  
400A  
350A  
315A  
250A  
200A  
450A  
350A  
400A  
315A  
250A  
200A  
160A  
160A  
125A  
104  
104  
100A  
80A  
63A  
50A  
103  
103  
A
A
2x102  
2x102  
1x102  
103  
104  
105  
106  
1x102  
103  
104  
105  
106  
Prospective Short-Circuit Current Symmetrical RMS  
Prospective Short-Circuit Current Symmetrical RMS  
630A fuse is derated to 1100V (IEC).  
Data Sheet: 17056630  
Data Sheet: 17056632  
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp  
161  
High Speed Fuses  
Square body flush end contact — 1250V/1300V (IEC/UL):  
50-1400A  
Size 2 — 250-1000A: 1250V  
Time-Current Curve  
Size 3 — 315-1400A: 1250V  
Time-Current Curve  
104  
103  
102  
A
A
101  
100  
10–1  
10–2  
10–3  
1x10–4  
1x102  
103  
104  
105  
Prospective Current In Amperes RMS  
Peak Let-Through Curve  
Peak Let-Through Curve  
1400A  
105  
1250A  
1000A  
800A  
1100A  
900A  
105  
B
1000A  
800A  
630A  
B
900A  
700A  
700A  
550A  
450A  
630A  
500A  
400A  
315A  
550A  
450A  
350A  
280A  
500A  
400A  
315A  
250A  
350A  
104  
104  
103  
103  
A
A
2x102  
1x102  
103  
104  
105  
106  
2x102  
1x102  
103  
104  
105  
106  
Prospective Short-Circuit Current Symmetrical RMS  
Prospective Short-Circuit Current Symmetrical RMS  
900-1000A fuses are derated to 1100V (IEC).  
1250-1400A fuses are derated to 1100V (IEC).  
Data Sheet: 17056634  
Data Sheet: 17056636  
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp  
162  

相关型号:

ETC

170M5497

Electric Fuse, 700A, 1300VAC, 100000A (IR), Inline/holder,
COOPER
ETC
ETC
ETC

170M5508

Square Body – Flush End Contact
ETC

170M5509

Square Body – Flush End Contact
ETC

170M5510

Square Body – Flush End Contact
ETC

170M5511

Square Body – Flush End Contact
ETC

170M5512

Square Body – Flush End Contact
ETC

170M5513

Square Body – Flush End Contact
ETC

170M5514

Square Body – Flush End Contact
ETC