ABC-2-12 [COOPER]

Fast-acting, ceramic tube;
ABC-2-12
型号: ABC-2-12
厂家: COOPER BUSSMANN, INC.    COOPER BUSSMANN, INC.
描述:

Fast-acting, ceramic tube

文件: 总3页 (文件大小:232K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Electrical UL/CSA  
Electrical IEC  
Electronics  
Consumer/Aftermarket  
OEM Transportation  
Terminal Blocks  
Systems/Services/Software  
Cooper Bussmann  
ABC-1/4-R  
Homepage  
About Cooper Bussmann  
Contact Us  
Fast-Acting 1/4 X 1-1/4 inch Fuse, Ceramic Tube RoHS  
Privacy  
Legal  
Cooper Bussmann® Brand  
Site Map  
Product Information  
Product Type:  
Product Family:  
Brand:  
Fuse  
Electronic  
Cooper Bussmann  
Certifications  
UL Listed  
Recommended Products  
CSA Certified  
S-8000 Series  
Rec. Fuse Block:  
Rec. Inline Fuse  
Holder:  
Electrical Properties  
HHB Series  
Maximum AC  
Voltage:  
250  
125  
Rec. Panel-mount  
Fuse Holder:  
HTB Series  
Maximum DC  
Voltage:  
1A1907 Series  
Rec. Fuse Clips:  
Amperage Rating: 0.25  
Physical Properties  
35 at 250V  
10000 at 125V  
AC Interrupting  
Ratings:  
1.25in.(L) × 0.25in.(W) ×  
0in.(H)  
Dimensions:  
10000 at 125V  
DC Interrupting  
Ratings:  
Melting I²T:  
Fast Acting:  
Resistance:  
Voltage Drop:  
0.02  
Yes  
3
3.25  
1/4" x 1-1/4" Fuses  
ABC Series, Fast Acting, Ceramic Tube  
Description  
RoHS  
2002/95/EC  
• Fast-acting, ceramic tube  
• Optional axial leads available  
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size  
• Ceramic tube, nickel-plated brass endcap construction  
• UL Listed product meets standard 248-14  
ELECTRICAL CHARACTERISTICS  
% of Amp Rating  
100%  
Opening Time  
4 Hours Minimum  
60 Minutes maximum  
120 Seconds Maximum  
135%  
200%  
Dimensions (mmin  
Drawing Not to Scale  
)
Agency Information  
• UL Listed Guide & File numbers (ABC 1/4 - 15A):  
JDYX & E19180.  
• UL Recognition Guide & File numbers (ABC 18 - 30A):  
JDYX2 & E19180.  
• CSA Certification Record No: 053787 C 000 &  
Class No: 1422 01 & 1422 30.  
Environmental Data  
• Shock: 1/4A and 1/2A – MIL-STD-202,  
Method 213, Test Condition I;  
1A thru 30A – MIL-STD-202, Method 207,  
(HI Shock)  
• Vibration: 1/4A thru 30A – MIL-STD-202,  
Method 204, Test Condition C (Except 5g, 500HZ)  
Ordering  
• Specify packaging, product, and option code  
SPECIFICATIONS  
Product  
Code  
Voltage  
Rating  
AC Interrupting  
Rating  
250V  
35A  
35A  
35A  
DC Interrupting  
Rating  
Typical DC Cold  
Resistance**  
(ohms)  
3.000  
Typical  
Melting I t†  
Typical  
Voltage  
Drop‡  
3.25  
0.51  
0.42  
0.35  
0.35  
0.25  
0.26  
0.25  
0.25  
0.23  
0.24  
0.20  
0.17  
0.15  
0.11  
0.12  
0.13  
0.12  
0.14  
2
AC  
DC  
125V  
125V  
75V  
AC  
0.02  
0.19  
0.8  
1.4  
2.9  
ABC-1/4  
ABC-1/2  
ABC-3/4  
ABC-1  
ABC-1-1/2  
ABC-2  
ABC-2-1/2  
ABC-3  
ABC-4  
ABC-5  
ABC-6  
ABC-7  
ABC-8  
ABC-10  
ABC-12  
ABC-15  
ABC-20  
ABC-25  
ABC-30  
250V  
250V  
250V  
250V  
250V  
250V  
250V  
250V  
250V  
250V  
250V  
250V  
250V  
250V  
250V  
250V  
250V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
1000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
10000A  
400A  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.788  
0.303  
0.197  
0.1175  
0.0755  
0.05875  
0.0435  
0.02975  
0.0286  
0.02315  
0.0183  
0.0146  
0.01205  
0.0068  
0.005425  
0.00366  
0.00263  
0.002225  
35A  
100A  
100A  
100A  
100A  
200A  
200A  
200A  
200A  
200A  
200A  
750A  
750A  
400A  
-
4.2  
8.53  
19.5  
29.1  
16.4  
31.6  
73.2  
111.9  
215.6  
129.6  
200.2  
550.8  
839.3  
1,429  
-
1000A  
1000A  
1000A  
1000A  
-
400A  
** DC Cold Resistance (Measured at 10% of rated current)  
Typical Melting I2t (A2Sec) (I2t was measured at listed interrupting rating and rated voltage. Measured at 70% to 80% power factor on AC)  
Typical Voltage Drop (Voltage drop was measured at 25°C 3°C ambient temperature at rated current)  
1/4" x 1-1/4" Fuses  
ABC Series, Fast Acting, Ceramic Tube  
TIME CURRENT CURVE  
PACKAGING CODE  
Packaging Code  
Description  
BK  
BK1  
BK8  
100 pieces of fuses packed into a cardboard carton  
1,000 pieces of fuses packed into a cardboard carton  
8,000 pieces of fuses packed into a cardboard carton  
OPTION CODE  
Description  
Option Code  
B
V
-R  
Board Washable - Hermetically sealed to withstand aqueous cleaning  
Axial leads - copper tinned wire with nickel plated brass overcaps  
RoHS compliant version  

相关型号:

ABC-2-12-R

ABC Series, Fast-Acting, Ceramic Tube
COOPER

ABC-2-R

ABC Series, Fast-Acting, Ceramic Tube
COOPER

ABC-20

Consumer Aftermarket Product Catalog
COOPER

ABC-20-R

ABC Series, Fast-Acting, Ceramic Tube
COOPER

ABC-21/2

Consumer Aftermarket Product Catalog
COOPER

ABC-25

Consumer Aftermarket Product Catalog
COOPER

ABC-25-R

ABC Series, Fast-Acting, Ceramic Tube
COOPER

ABC-3

Consumer Aftermarket Product Catalog
COOPER

ABC-3-R

Fast-acting, ceramic tube Optional axial leads available
COOPER

ABC-3/4-R

Electric Fuse, Fast Blow, 0.75A, 250VAC, 125VDC, 35A (IR), Inline/holder, ROHS COMPLIANT
COOPER

ABC-30

Consumer Aftermarket Product Catalog
COOPER

ABC-30-R

ABC Series, Fast-Acting, Ceramic Tube
COOPER