BK/S505-V-1.6-R [COOPER]
TIME DELAY BLOW ELECTRIC FUSE, 1.6A, 250VAC, 1500A (IR), THROUGH HOLE, ROHS COMPLIANT;型号: | BK/S505-V-1.6-R |
厂家: | COOPER BUSSMANN, INC. |
描述: | TIME DELAY BLOW ELECTRIC FUSE, 1.6A, 250VAC, 1500A (IR), THROUGH HOLE, ROHS COMPLIANT |
文件: | 总2页 (文件大小:376K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
5 x 20mm Fuses
S505 Series, Time-Delay, Ceramic Tube
Description
HALOGEN
• Time-delay, high breaking capacity
HF
• Optional axial leads available
FREE
• Ceramic tube, silver-plated endcap construction
(500mA-800mA), nickel-plated brass endcap
construction (1-12A)
• Optional sleeve is flexible flouropolymer (UL
flammability rating VW-1)
• 5 x 20mm physical size
Dimensions - mm
• Designed to IEC 60127-2 (500mA-10A) & extension 12A
Drawing Not to Scale
Electrical Characteristics
1.5 I
min
2.1 I
2.75 I
4 I
10 I
n
n
n
n
n
max
5s
In
<1A
max
min
max
min
50 ms
95 ms
min
max
60 min 30 min 250 ms 80s
5 ms 150 ms
10 ms 150 ms
10 ms 150 ms
10 ms 150 ms
1A-3.15A 60 min 30 min 750ms
4A-6.3A 60 min 30 min 750ms
8A-12A 30 min 30 min 750ms
80s
5s
80s 150 ms 5s
80s 150 ms 5s
Agency Information
• UL Recognized Card: Guide JDYX2, File E19180
• CSA Component Acceptance: File 53787
• SEMKO: File 500496, 816547
• VDE: File 40014091, 40024352, 40023140
• BSI: File KM55676
• Ratings above 4A have a maximum 0.81mm diameter
lead
• IMQ: File 00100, 00529
• With TR2 packaging code, lead wire length is 19.05mm
• PES+JET: File 1641-31003-1004,1641-31003-1011
• CCC: File 2002010207011295
• EK: File SU05011-4012A, SU0511-5014A
• FIMKO: File FI21555
Ordering
• Specify packaging code
• Insert packaging code prefix before part number.
E.g. BK (or BK1)/S505-1-R
• Specify option codes if desired
• For axial leads, insert “V” between catalog series and
amp rating. E.g., BK/S505-V-1-R
Specifications
Interrupting
Voltage Rating (amps)
Typical
DC Cold
Resistance Pre-arching
(W)**
Typical
Voltage
Drop
(mV)‡
295
189
152.5
150
125
118.5
115
102.5
86.5
77.5
75
Typical
Part
Number
S505-500-R 250
S505-800-R 250
S505-1-R
S505-1.25-R 250
S505-1.6-R 250
S505-2-R
S505-2.5-R 250
S505-3.15-R 250
S505-4-R
S505-5-R
Rating
Vac
@ Rated
Vac (50Hz)*
1500
Agency Approvals
IMQ VDE SEMKO UL CCC PSEJET
I2t AC***
0.188†
0.632†
1.28
2.22
6.78
CSA
X
X
X
X
X
X
X
X
X
X
X
X
EK
BSI
X
X
X
X
X
X
X
X
X
X
X
X
0.5070
0.2370
0.1401
0.1075
0.0700
0.0545
0.0395
0.0305
0.0185
0.0131
0.0033
0.0067
0.0061
0.0053
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
250
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
250
9.60
16.60
36.60
38.45†
71.30†
197
311
397
713.7†
250
250
S505-6.3-R 250
S505-8-R
S505-10-R
S505-12-R
250
250
250
75
72
77
X
X
1000
* Interrupting ratings (500mA to 10A were measured at 70% to 80% PF on.
** Typical DC Cold Resistance (Measured At <10% of rated current).
*** Typical Pre-Arching I2t (Measured at listed interrupting rating and rated voltage if not specified).
† The typical I2t value was measured at 10 times of rated current under DC.
‡ Typical Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).
0409 BU-SB08329
Page 1 of 2
Data Sheet 2037
Amp
Rating
Current In Amps
Packaging Code
Packaging Code Prefix
Description
BK
BK1
TR2
100 fuses packed into a cardboard carton
1,000 fuses packed into a poly bag
1,500 fuses packed into tape on a reel (19.05mm lead wire length)
Option Code
Option Code
V
Description
Axial leads - copper tinned wire with nickel plated brass overcaps
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained
in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support
systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in
significant injury to the user.
© 2009 Cooper Bussmann
St. Louis, MO 63178
www.cooperbussmann.com
0409 BU-SB08329
Page 2 of 2
Data Sheet 2037
相关型号:
BK/S505-V-12-R
TIME DELAY BLOW ELECTRIC FUSE, 12A, 250VAC, 1000A (IR), THROUGH HOLE, ROHS COMPLIANT
COOPER
BK/S505-V-2.5-R
TIME DELAY BLOW ELECTRIC FUSE, 2.5A, 250VAC, 1500A (IR), THROUGH HOLE, ROHS COMPLIANT
COOPER
BK/S505-V-3.15-R
TIME DELAY BLOW ELECTRIC FUSE, 3.15A, 250VAC, 1500A (IR), THROUGH HOLE, ROHS COMPLIANT
COOPER
BK/S505-V-5-R
TIME DELAY BLOW ELECTRIC FUSE, 5A, 250VAC, 1500A (IR), THROUGH HOLE, ROHS COMPLIANT
COOPER
©2020 ICPDF网 联系我们和版权申明