EBI055-750E [COOPER]

Electric Fuse, 750A, 5500VAC, 63000A (IR), Inline/holder;
EBI055-750E
型号: EBI055-750E
厂家: COOPER BUSSMANN, INC.    COOPER BUSSMANN, INC.
描述:

Electric Fuse, 750A, 5500VAC, 63000A (IR), Inline/holder

电路保护
文件: 总1页 (文件大小:54K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Medium Voltage Fuses  
E-rated fuses: CL-14 & bolt-In  
ECL055 & EBI055  
Specifications  
Description: E-rated medium voltage, current-limiting fuses  
for transformer and feeder protection.  
Construction: Filament wound, glass epoxy fuse tube, with  
silica filler, and silver-plated copper terminals and endcaps  
containing a silver element in a double concentric helical  
configuration.  
Catalog Numbers  
Ratings:  
Catalog  
Numbers  
Amp  
Rating  
IR  
# of  
Barrels Style  
Volts: — 5.5 kV  
Voltage  
Max Sym.  
ECL055-10E  
ECL055-15E  
ECL055-20E  
ECL055-25E  
ECL055-30E  
ECL055-40E  
ECL055-50E  
ECL055-65E  
ECL055-80E  
ECL055-100E  
ECL055-125E  
ECL055-150E  
ECL055-200E  
ECL055-250E  
ECL055-300E  
ECL055-400E  
ECL055-450E  
ECL055-500E  
ECL055-600E  
EBI055-750E  
EBI055-900E  
10  
15  
20  
25  
30  
40  
50  
65  
5.5kV  
Amps: — 10-900A  
IR: — 63kA Sym. Max  
Agency Information: Meets E requirements per ANSI  
C37.46, Meets General Purpose requirements per ANSI  
C37.40.  
1
Clip-Lock  
Features and Benefits  
• Clip-lock and bolt-in style available in double and triple barrel  
fuse designs for application flexibility  
• The filament wound, glass epoxy fuse tube provides UV and  
moisture protection, making these medium voltage fuses  
suitable for both indoor and outdoor applications  
• Open fuse indication (indicator travel distance is 16mm)  
easily integrates into automation schemes  
• 50/60 Hz operating frequency make these fuses applicable  
world-wide  
80  
100  
125  
150  
200  
250  
300  
400  
450  
500  
600  
750  
900  
63kA  
Clip-Lock  
2
3
Bolt-In  
Typical Applications  
• 5.0 kV Transformer Primary Protection  
• 5.0 kV Feeder Circuit Protection  
• 5.0 kV Voltage Switches  
Catalog Number Construction (Example)  
Catalog Number Voltage Rating  
Ampere Rating  
500E  
• 5.0 kV Metal-enclosed Switchgear  
ECL  
055  
055 = 5.5 kV  
Catalog Number Cross Reference  
Current-limiting medium voltage fuses are  
classified into three categories:  
Cooper Bussmann Ferraz-Shawmut  
Ferraz-Shawmut  
Old Catalog #  
1. Full Range - defined by ANSI as “a fuse capable of  
interrupting all currents from the maximum rated interrupting  
current down to the minimum continuous current that causes  
melting of the fusible element(s), when the fuse is applied at  
the maximum ambient temperature specified by the  
manufacturer.It is able to interrupt any normal 60 cycle  
current that will melt its element.  
Catalog Numbers  
ECL055-10E  
ECL055-15E  
ECL055-20E  
ECL055-25E  
ECL055-30E  
ECL055-40E  
ECL055-50E  
ECL055-65E  
ECL055-80E  
ECL055-100E  
ECL055-125E  
ECL055-150E  
ECL055-200E  
ECL055-250E  
ECL055-300E  
ECL055-400E  
ECL055-450E  
ECL055-500E  
ECL055-600E  
ECL055-750E  
ECL055-900E  
New Catalog #  
A055C1DORO-10E  
A055C1DORO-15E  
A055C1DORO-20E  
A055C1DORO-25E  
A055C1DORO-30E  
A055C1DORO-40E  
A055C1DORO-50E  
A055C1DORO-65E  
A055C1DORO-80E  
A055C1DORO-100E  
A055C1DORO-125E  
A055C1DORO-150E  
A055C1DORO-200E  
A055C1DORO-250E  
A055C1DORO-300E  
A055C1DORO-400E  
A055C2DORO-450E  
A055C2DORO-500E  
A055C2DORO-600E  
A055B3DORO-750E  
A055B3DORO-900E  
225-007-937  
225-007-938  
225-007-939  
225-007-940  
225-007-941  
225-007-942  
225-007-943  
225-007-944  
225-007-945  
225-007-946  
225-007-947  
225-007-948  
225-007-949  
225-007-950  
225-007-951  
225-007-952  
225-007-953  
225-007-954  
225-007-955  
A055X750E-4  
A055X900E-4  
2. General Purpose - defined by ANSI C37.40 as “a fuse  
capable of interrupting all currents from the maximum rated  
interrupting current down to the current that causes melting of  
the fusible element in one hour.Not all currents fall within  
this range. It is possible to receive an overcurrent lower than  
the value given by the one hour criterion.  
3. Back-up - defined by ANSI C37.40 as “a fuse capable of  
interrupting all currents from the maximum rated interrupting  
current down to the rated minimum interrupting current.The  
minimum rated interrupting current is the lowest current that  
the fuse will be able to clear properly. This creates a need to  
place a low current interrupting device in series with the  
back-up rated fuse.  
Data Sheet: 9002  
For product Data Sheets, visit www.cooperbussmann.com/products/datasheet.asp  
71  

相关型号:

EBI055-900E

Electric Fuse, 900A, 5500VAC, 63000A (IR), Inline/holder
COOPER

EBIPA100

QUICK BRAID Cleaner, Faster, More Consistent
ETC

EBIPA15

DESOLDERING BRAID
ETC

EBJ02A

EURO BLOCKS TS & EB SERIES
ADAM-TECH

EBJ02B

EURO BLOCKS TS & EB SERIES
ADAM-TECH

EBJ02H

EURO BLOCKS TS & EB SERIES
ADAM-TECH

EBJ02J

EURO BLOCKS TS & EB SERIES
ADAM-TECH

EBJ02K

EURO BLOCKS TS & EB SERIES
ADAM-TECH

EBJ05A

EURO BLOCKS TS & EB SERIES
ADAM-TECH

EBJ05B

EURO BLOCKS TS & EB SERIES
ADAM-TECH

EBJ05H

EURO BLOCKS TS & EB SERIES
ADAM-TECH

EBJ05J

EURO BLOCKS TS & EB SERIES
ADAM-TECH