EDCC0.5 [COOPER]

Electric Fuse, Time Delay Blow, 0.5A, 600VAC, 300VDC, 200000A (IR), Inline/holder;
EDCC0.5
型号: EDCC0.5
厂家: COOPER BUSSMANN, INC.    COOPER BUSSMANN, INC.
描述:

Electric Fuse, Time Delay Blow, 0.5A, 600VAC, 300VDC, 200000A (IR), Inline/holder

文件: 总2页 (文件大小:242K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
EDCC  
Class CC, 600Vac, 0.5 to 30A  
Time-Delay Fuses  
Dimensions (inches)  
• Can be used where either a time-delay or a fast-acting  
fuse is needed, making selection easier and reducing  
spare fuse inventories for substantial cost reduction.  
Catalog Symbol: EDCC  
Time-Delay  
• Superior Motor Protection for small horsepower motor  
circuits.  
Current-Limiting  
Volts: 600Vac (or less)  
300Vdc (or less)  
Amps: 0.5 to 30A  
IR: 200kA RMS Sym.  
• Proper sizing can provide Type “2” coordinated  
protection for NEMA and IEC motor controllers.  
• Motors receive maximum protection against burnout  
from overloads and single phasing.  
20kAIC (0.5 – 2.25A and 20-30A)  
Agency Information: CE, UL Listed, Std. 248-4, Class CC,  
Guide JDDZ, File E162363, CSA Certified, HRCI-CC, C22.2  
No. 248.4, Class 1422-02, File 53787  
Catalog Numbers (amps)  
EDCC0.5  
EDCC0.6  
EDCC0.8  
EDCC1  
EDCC1.125  
EDCC1.25  
EDCC1.4  
EDCC1.6  
EDCC1.8  
EDCC2  
EDCC2.25  
EDCC2.5  
EDCC2.8  
EDCC3  
EDCC4  
EDCC4.5  
EDCC5  
EDCC5.6  
EDCC6  
EDCC6.25  
EDCC7  
EDCC8  
EDCC9  
EDCC10  
EDCC12  
EDCC15  
EDCC20  
EDCC25  
EDCC30  
Features  
• A superior all-purpose, space-saving branch circuit fuse  
that meets most protection requirements up to 30 amps.  
13  
1
• Very compact; physical size is only 32" x 1 ⁄  
2"  
EDCC3.2  
EDCC 3.5  
(10.3 x 38.1mm) with rejection tip.  
EDCC7.5  
• Faster response to damaging short-circuit currents and  
higher interrupting rating than mechanical overcurrent  
protective devices.  
Carton Quantity and Weight  
• Maximum 200kA interrupting rating for available fault  
current in today's large capacity systems. Helps ensure  
that future growth will not obsolete the system.  
Carton  
Quantity  
10  
Weight per Carton  
Amps  
0.5-30  
lbs  
kg  
0.09  
0.19  
• Time-delay to avoid unwanted fuse openings from surge  
currents.  
Class CC Fuse Blocks (600V) Catalog Data  
• Fast speed of response under short-circuit conditions for  
a high degree of current-limitation.  
Screw  
Pressure  
Screw  
Pressure  
Plate  
Box  
Quick-  
Quick-  
Poles Terminal  
Terminal Connect  
Connect  
• The EDCC fuse can be sized close to full load ratings  
for maximum overload and short-circuit protection.  
1
2
3
BC6031S BC6031P BC6031B BC6031SQ BC6031PQ  
BC6032S BC6032P BC6032B BC6032SQ BC6032PQ  
BC6033S BC6033P BC6033B BC6033SQ BC6033PQ  
Form No. EDCC  
Page 1 of 2  
Data Sheet #1300  
07-10-07  
BU-SB07255  
EDCC  
Class CC, 600Vac, 0.5 to 30A  
Time-Delay Fuses  
Current Limitation Curves  
Time-Current Characteristic Curves– Average  
Melt  
Current-Limiting Effects  
EDCC Apparent RMS Symmetrical Let-Through Current  
Prosp.  
SCC  
1.25  
100  
140  
165  
210  
260  
290  
315  
340  
350  
390  
420  
525  
2.2A  
135  
210  
255  
340  
435  
525  
610  
650  
735 1050  
785 1130  
830 1210  
1100 1600  
15A  
240  
350  
420  
540  
680  
800  
870  
915  
20A  
305  
25A  
380  
30A  
1000  
435  
3000  
440  
575  
580  
710  
5000  
570  
690  
870  
10,000  
20,000  
30,000  
40,000  
50,000  
60,000  
80,000  
100,000  
200,000  
700  
1000  
1305  
1520  
1700  
1820  
1980  
2180  
2400  
3050  
870  
1090  
1300  
1390  
1520  
1650  
1780  
2000  
2520  
1030  
1150  
1215  
1300  
1500  
1600  
2000  
*RMS Symmetrical Amps Short-Circuit  
NOTE: To calculate I (I ) multiply I value x 2.3.  
RMS  
p
peak  
The only controlled copy of this document is the electronic read-only version maintained by Cooper Bussmann. All other copies of this document are by definition uncontrolled. This bulletin  
is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right,  
without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, with-  
out notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.  
Form No. EDCC  
07-10-07  
BU-SB07255  
Page 2 of 2  
Data Sheet #1300  

相关型号:

EDCC0.6

Electric Fuse, Time Delay Blow, 0.6A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

EDCC0.8

Electric Fuse, Time Delay Blow, 0.8A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

EDCC1.125

Electric Fuse, Time Delay Blow, 1.125A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

EDCC1.25

Electric Fuse, Time Delay Blow, 1.25A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

EDCC1.4

Electric Fuse, Time Delay Blow, 1.4A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

EDCC1.6

Electric Fuse, Time Delay Blow, 1.6A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

EDCC1.8

Electric Fuse, Time Delay Blow, 1.8A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

EDCC10

Electric Fuse, Time Delay Blow, 10A, 600VAC, 300VDC, 200000A (IR), Inline/holder,
COOPER

EDCC12

Electric Fuse, Time Delay Blow, 12A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

EDCC15

Electric Fuse, Time Delay Blow, 15A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

EDCC2

Electric Fuse, Time Delay Blow, 2A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

EDCC2.25

Electric Fuse, Time Delay Blow, 2.25A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER