FRN-R-8* [COOPER]

Fusetron™ FRN-R Class RK5 250Vac/125Vdc 1⁄10-60A, dual element, time-delay fuses;
FRN-R-8*
型号: FRN-R-8*
厂家: COOPER BUSSMANN, INC.    COOPER BUSSMANN, INC.
描述:

Fusetron™ FRN-R Class RK5 250Vac/125Vdc 1⁄10-60A, dual element, time-delay fuses

文件: 总6页 (文件大小:672K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Effective February 2016  
Supersedes July 2013  
Technical Data1019  
Fusetron™ FRN-R Class RK5 250Vac/125Vdc  
1⁄10-60A, dual element, time-delay fuses  
Catalog numbers (amps) — non-indictaing fuses  
FRN-R-1⁄10  
FRN-R-1⁄8  
FRN-R-1-8⁄10  
FRN-R-2  
FRN-R-8*  
FRN-R-9*  
FRN-R-15⁄100  
FRN-R-2⁄10  
FRN-R-1⁄4  
FRN-R-2-1⁄4  
FRN-R-2-1⁄2  
FRN-R-2-8⁄10  
FRN-R-3  
FRN-R-10*  
FRN-R-12*  
FRN-R-15*  
FRN-R-17-1⁄2*  
FRN-R-20*  
FRN-R-25*  
FRN-R-30*  
FRN-R-35*  
FRN-R-40*  
FRN-R-45*  
FRN-R-50*  
FRN-R-60*  
FRN-R-3⁄10  
FRN-R-4⁄10  
FRN-R-1⁄2  
FRN-R-3-2⁄10  
FRN-R-3-1⁄2  
FRN-R-4  
FRN-R-6⁄10  
FRN-R-8⁄10  
FRN-R-1  
FRN-R-4-1⁄2  
FRN-R-5  
Catalog symbols:  
•ꢀ  
FRN-R-_ (non-indicating)  
FRN-R-1-1⁄8  
FRN-R-1-1⁄4  
FRN-R-1-4⁄10  
FRN-R-1-1⁄2  
FRN-R-1-6⁄10  
FRN-R-5-6⁄10  
FRN-R-6  
•ꢀ  
FRN-R-_ID (indicating)  
FRN-R-6-1⁄4  
FRN-R-7  
Description:  
Eaton Bussmann® series advanced protection,  
energy efficient FRN-R Class RK5 dual element,  
current-limiting, time-delay fuses with optional  
open fuse indication on select ratings. Time-delay  
– 10 seconds (minimum) at 500% of rated current  
(8 seconds for 1⁄10-30A sizes).  
FRN-R-7-1⁄2  
* Open fuse indication available by inserting the sufix “ID.”  
E.g., FRN-R-15ID.  
Carton Quantity:  
Amp rating  
Carton qty.  
1⁄10 – 60  
10  
Specifications:  
Ratings  
Features:  
•ꢀ  
Volts  
•ꢀ  
Provides motor overload, ground fault and  
short-circuit protection  
•ꢀ 250Vac  
•ꢀ 125Vdc  
•ꢀ  
•ꢀ  
•ꢀ  
•ꢀ  
Helps protect motors against burnout from  
overloads  
•ꢀ  
Amps 1⁄10-60A  
Helps protect motors against burnout from  
single-phasing on three-phase systems  
•ꢀ  
Interrupting rating  
•ꢀ 200kA Vac RMS Sym.  
•ꢀ 20kA Vdc  
Simplifies and improves blackout prevention  
(selective coordination)  
Dual-element fuses can be applied in circuits  
subject to temporary motor overloads and surge  
currents to provide both high performance  
short-circuit and overload protection  
Agency information  
•ꢀ  
UL Listed, Std. 248-12, Class RK-5, Guide  
JDDZ, File E4273  
•ꢀ  
•ꢀ  
The overload element provides protection  
against low level overcurrent of overloads  
and will hold an overload which is five times  
greater than the ampere rating of the fuse for a  
minimum of ten seconds  
CSA Certified, C22.2 No. 248.12, Class 1422-  
02, File 53787  
•ꢀ  
CE  
FRN-R Class RK5 250Vac/125Vdc  
1⁄10-60A, dual element, time-delay fuses  
Technical Data 1019  
Effective February 2016  
Dimensions - in:  
2"  
( 0.031  
0.56" ( 0.0ꢀ1  
up to 30A  
3"  
( 0.031  
0.8ꢀ" ( 0.0ꢀ1  
35 to 60A  
Recommended fuse blocks:  
Fuse amps  
up to 30  
1-pole  
RM25030-1_  
RM25060-1CR  
2-pole  
3-pole  
RM25030-2_  
RM25030-3_  
35 to 60  
RM25060-2CR  
RM25060-3CR  
For additional information see data sheet no. 10289.  
Fuse reducers for Class R fuses  
Amp size of fuse block or disconnect  
Catalog no.  
(pairs)  
Fuse size  
Up to 30A  
Up to 30A  
35 to 60A  
35 to 60A  
switch  
60A  
No.263-R  
No.213-R  
No.216-R  
No.226-R  
100A  
200A  
For additional information on Class R fuse reducers, see data sheet  
no 1118.  
2
Eaton.com/bussmannseries  
FRN-R Class RK5 250Vac/125Vdc  
1⁄10-60A, dual element, time-delay fuses  
Technical Data 1019  
Effective February 2016  
Time-current curves — average melt:  
1⁄10 to 6-1⁄4 amps  
Amp rating  
Current in amps  
3
Eaton.com/bussmannseries  
FRN-R Class RK5 250Vac/125Vdc  
1⁄10-60A, dual element, time-delay fuses  
Technical Data 1019  
Effective February 2016  
Time-current curves — average melt:  
8 to 60 amps  
Amp rating  
8 10 15  
30  
60  
Current in amps  
4
Eaton.com/bussmannseries  
FRN-R Class RK5 250Vac/125Vdc  
1⁄10-60A, dual element, time-delay fuses  
Technical Data 1019  
Effective February 2016  
Current-limitation curves:  
Current-limiting effects:  
Let-through current  
(apparent RMS Sym. vs. fuse rating)  
B
400000  
300000  
Prosp. S.C.C.  
30A  
60A  
200000  
5000  
1000  
2000  
2000  
2000  
2000  
2000  
2000  
2000  
3000  
3000  
3000  
3000  
3000  
3000  
4000  
4000  
2000  
3000  
3000  
4000  
4000  
4000  
4000  
5000  
5000  
5000  
6000  
6000  
6000  
6000  
7000  
8000  
10,000  
15,000  
20,000  
25,000  
30,000  
35,000  
40,000  
50,000  
60,000  
70,000  
80,000  
90,000  
100,000  
150,000  
200,000  
100000  
90000  
80000  
70000  
60000  
50000  
40000  
30000  
20000  
60A  
30A  
10000  
9000  
8000  
7000  
6000  
5000  
4000  
3000  
A
2000  
1000  
RMS SYMMETRICAL CURRENT IN AMPS  
A-B = ASYMMETRICAL AVAILABLE PEAK (2.3 X SYM RMS AMPS)  
5
Eaton.com/bussmannseries  
FRN-R Class RK5 250Vac/125Vdc  
1⁄10-60A, dual element, time-delay fuses  
Technical Data 1019  
Effective February 2016  
The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document  
are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help  
the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or  
limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin.  
Once a product has been selected, it should be tested by the user in all possible applications.  
Eaton  
1000 Eaton Boulevard  
Cleveland, OH 44122  
Eaton.com  
Bussmann Division  
114 Old State Road  
Ellisville, MO 63021  
United States  
Eaton.com/bussmannseries  
Follow us on social media to get the  
latest product and support information.  
© 2016 Eaton  
All Rights Reserved  
Printed in USA  
Publication No. 1019 — BU-SB13730  
February 2016  
Eaton, Bussmann and Fusetron are valuable  
trademarks of Eaton in the U.S. and other  
countries. You are not permitted to use  
the Eaton trademarks without prior written  
consent of Eaton.  

相关型号:

FRN-R-8/10

Electric Fuse, Time Delay Blow, 0.8A, 250VAC, 125VDC, 200000A (IR), Inline/holder
COOPER

FRN-R-8/10

Fusetron™ FRN-R Class RK5 250Vac/125Vdc 1⁄10-60A, dual element, time-delay fuses
EATON
ETC
ETC

FRN-R-8ID

Electric Fuse, Time Delay Blow, 8A, 250VAC, 125VDC, 200000A (IR), Inline/holder
COOPER

FRN-R-9

Electric Fuse, Time Delay Blow, 9A, 250VAC, 125VDC, 200000A (IR), Inline/holder
COOPER

FRN-R-9

Fusetron™ FRN-R Class RK5 250Vac/125Vdc 1⁄10-60A, dual element, time-delay fuses
EATON

FRN-R-9*

Fusetron™ FRN-R Class RK5 250Vac/125Vdc 1⁄10-60A, dual element, time-delay fuses
COOPER
ETC

FRN-R-9ID

Electric Fuse, Time Delay Blow, 9A, 250VAC, 125VDC, 200000A (IR), Inline/holder
COOPER

FRN01C

Circuit Protection Solutions Low Voltage Fuse Links Catalogue
COOPER

FRN02C

Circuit Protection Solutions Low Voltage Fuse Links Catalogue
COOPER