FWP-6A14F [COOPER]

FWP 660V/700V (IEC/U.L.); FWP 660V / 700V ( IEC / U.L 。 )
FWP-6A14F
型号: FWP-6A14F
厂家: COOPER BUSSMANN, INC.    COOPER BUSSMANN, INC.
描述:

FWP 660V/700V (IEC/U.L.)
FWP 660V / 700V ( IEC / U.L 。 )

电熔丝 电路保护
文件: 总1页 (文件大小:42K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
Bu s s m a n n  
Fe rrule  
®
FWP 660V/700V (IEC/U.L.) 1-50A  
Electrical Characteristics  
Ordering Information  
Dimensions  
Curves  
BIF #  
I2t (A2S)  
Rated  
Current  
Carton  
Weight  
(kg)  
Clearing  
at 660V  
Watts  
Loss  
Part  
Number  
Carton  
Qty.  
Figure  
Number  
Size  
RMS-Amps  
Pre-arc  
1
2
11  
22  
75  
180  
320  
450  
600  
750  
1800  
1.5  
4
5.5  
6
7
FWP-1A14F  
FWP-2A14F  
FWP-3A14F  
FWP-4A14F  
FWP-5A14F  
FWP-6A14F  
FWP-10A14F  
FWP-15A14F  
FWP-20A14F  
FWP-25A14F  
FWP-30A14F  
FWP-32A14F  
FWP-40A14F  
FWP-50A14F  
3
4
5
6
1.6  
14 ≈ 51mm  
(·Ω¡§∑)  
10  
15  
20  
25  
30  
32  
40  
50  
3.6  
10  
26  
44  
58  
68  
84  
200  
10  
0.225  
Fig. 1  
35785307  
9
7.6  
8
9
Interrupting rating 200kA RMS Symmetrical.  
Watts loss provided at rated current.  
1 kg = 2.2 lbs.  
1 lb = 0.45 kg  
(700 Vdc/Interrupting rating 50kA) U.L. Recognition.  
CSA Component Acceptance: 5 - 30A.  
R
Dimensions  
Fig. 1: 1-50 Amp Range  
50.8  
(2.000")  
14.3  
(0.563")  
15.5  
(0.610")  
Dimension in mm.  
1mm = 0.0394∑  
1∑ = 25.4mm  
Electrical Characteristics  
Total Clearing I2t  
Arc Voltage  
Power Losses  
The total clearing I2t at rated voltage and This curve gives the peak arc voltage,  
Watts loss at rated current is given in  
the electrical characteristics. The curve  
allows the calculation of the power  
losses at load currents lower than the  
rated current. The correction factor, Kp,  
is given as a function of the RMS load  
current, Ib, in % of the rated current .  
at power factor of 15% are given in the  
electrical characteristics. For other volt-  
ages, the clearing I2t is found by multi-  
plying by correction factor, K, given as  
a function of applied working voltage,  
Eg, (RMS).  
UL, which may appear across the fuse  
during its operation as a function of the  
applied working voltage, Eg, (RMS) at a  
power factor of 15%.  
1.4  
1.4  
1.0  
Kp  
1.2  
K
1.2 UL  
0.8  
1.0  
0.9  
0.8  
0.7  
103  
9
8
0.6  
0.5  
0.4  
0.3  
7
0.6  
6
0.5  
1)  
5
0.2  
0.4  
2)  
4
Eg  
Eg  
500 600 700  
Ib  
0.1  
0.3  
200 300  
3
200 300  
400  
400  
500 600 700  
30 40 50 60  
80 90 100%  
70  
1) 5-30 Amp Range  
2) 32-50 Amp Range  
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann  
Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly  
present comprehensive product data and provide technical information that will help the end user with design  
applications. Bussmann reserves the right, without notice, to change design or construction of any products and  
to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without  
notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested  
by the user in all possible applications.  
Form No.  
Page 1 of 1  
BIF Doc #720025  
SB01191  
7-18-01  

相关型号:

FWP-700A

High Speed Fuses
COOPER

FWP-70B

High Speed Fuses
COOPER

FWP-800A

High Speed Fuses
COOPER

FWP-80A22Fa

Ferrule fuses
COOPER

FWP-80A22FI

Ferrule fuses
COOPER

FWP-80B

High Speed Fuses
COOPER

FWP-900A

High Speed Fuses
COOPER

FWP-90B

High Speed Fuses
COOPER