GMT-18100A_16 [COOPER]
Fast-acting indicating fuse 60 volts dc, 125 volts ac;型号: | GMT-18100A_16 |
厂家: | COOPER BUSSMANN, INC. |
描述: | Fast-acting indicating fuse 60 volts dc, 125 volts ac |
文件: | 总2页 (文件大小:375K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
BUSSMANN
Effective June 2016
Supersedes July 2008
Technical Data 5008
SERIES
Fast-acting indicating fuse 60 volts dc,
125 volts ac
Features:
•ꢀ
For telecommunications, computer, or
control circuits
•ꢀ
Visual spring indicating and alarm circuit
indicating
•ꢀ
•ꢀ
Color coded flags designate ampere rating.
Fuses easily replaced without use of
insulated tools
•ꢀ
Fuses can be removed with wire hook when
mounted on minimum centers
Description:
Bussmann® series fast-acting fuses for use in
HLT, HLS and PCT fuse holders.
Dimensions - in (mm):
0.127
Contact and
alarm spring
0.107
Specifications:
Ratings
•ꢀ
Volts — 60 Vdc/125 Vac
•ꢀ
Amps — up to 15 A
0.688
Max.
0.585
Agency Information
UL® Recognized, Guide JFHR2, File E56412
•ꢀ
0.118
0.780
•ꢀ
RoHS Compliant
Materials
0.20"
Covers - in (mm)
•ꢀ
Body:Thermosplastic, UL 94 V0
(5.1mm)
flammability rating
BUSS GMT-X
•ꢀ
Terminals:Tin-plated beryllium copper
0.95"
Carton quantity and weight
(24.0mm)
•ꢀ
Quantity: - 100 fuses per carton
0.36"
•ꢀ
Weight: - 0.33 lbs. (150g.)
(9.0mm)
0.84"
Fuse holders
(21.3mm)
•ꢀ
Catalog Nos. HLT, HLS, and PCT
GMT-X fuse cover
Fuse covers
0.20"
0.95"
•ꢀ
GMT-X
(5.1mm)
(24.0mm)
•ꢀ
GMT-Y (with pull-tab)
BUSS GMT-Y
0.7"
(17.8mm)
0.84"
(21.3mm)
GMT-Y fuse cover
Technical Data 5008
Effective May 2016
Fast-acting indicating fuse
60 volts dc, 125 volts ac
Catalog symbol and color codes
Time-current characteristic curves-average melt
Catalog
symbol
Color
code
Catalog
symbol
Color
code
GMT-18/100 A Yellow
GMT-3 1/2 A
GMT-4 A
White/Blue
White/Brown
Green
Amp
Rating
GMT-1/4 A
GMT-3/8 A
GMT-1/2 A
Violet
300
100
White/Gray
Red
GMT-5 A
GMT-7 1/2 A
GMT-10 A
Black/White
Red/White
Yellow/Green
Red/Blue
Gray
GMT-65/100 A Black
GMT-3/4 A
GMT-1 A
Brown
Gray
GMT-12 A
GMT-15 A
GMT-1 1/3 A
GMT-1 1/2 A
GMT-2 A
White
GMT-Dummy
GMT-A (alarm)*
GMT-X (cover)
White/Yellow
Orange
Blue
Yellow
10
Clear
GMT-3 A
*Designed specifically for use inTelpower® 15800 fused disconnect switch.
1
0.1
0.01
Current in amps
Test specifications
Percent
Opening
overload
time
100%
150%
10 min. (minimum)
5 min. (maximum)
The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this
document are by definition uncontrolled.This bulletin is intended to clearly present comprehensive product data and provide technical
information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction
of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice,
any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible
applications.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
For Eaton’s Bussmann series
product information,
call 1-855-287-7626 or visit:
Eaton.com/bussmannseries
Eaton.com
Bussmann Division
114 Old State Road
Ellisville, MO 63021
United States
Eaton, Bussmann andTelpower are
valuable trademarks of Eaton in the US
and other countries.You are not permitted
to use the Eaton trademarks without prior
written consent of Eaton.
Eaton.com/bussmannseries
Follow us on social media to get the
latest product and support information.
© 2016 Eaton
All Rights Reserved
Printed in USA
Publication No. 5008 – SB98107
June 2016
UL is a registered trademark of the
Underwriters Laboratories, Inc.
相关型号:
©2020 ICPDF网 联系我们和版权申明