JFL70 [COOPER]
Electric Fuse, Fast Blow, 70A, 600VAC, 300VDC, 200000A (IR), Inline/holder,;型号: | JFL70 |
厂家: | COOPER BUSSMANN, INC. |
描述: | Electric Fuse, Fast Blow, 70A, 600VAC, 300VDC, 200000A (IR), Inline/holder, |
文件: | 总2页 (文件大小:77K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
JFL CLASS J
FAST-ACTING FUSES
Catalog Number JFL (1 - 600A) 600 Volts AC or Less
AMPERE RATINGS
JFL 600V
JFL SPECIFICATIONS
Fast-Acting
1
2
3
4
5
6
8
10
12
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225
250
300
350
400
450
500
600
—
Voltage Rating:
Ampere Rating:
JFL - 600VAC
1 - 600 Amps
Interrupting Rating: 200,000 RMS Symmetrical Amps
Current Limiting:
Class J Fuse
EDISON JFL Class J fuses are among the most current lim-
iting fuses available. Their small physical size and high per-
formance characteristics makes Class J fuses ideal for any
space - limited application.
Agency Approvals:
UL Listed, Class J, Guide JDDZ, File E162363
CSA Certified HRCI-J per C22.2, No. 248.8
Self-Certified DC Ratings:
Voltage Rating:
EDISON JFL fuses are best suited for the protection of non-
inductive loads such as resistive heating, and lighting cir-
cuits.
JFL (1-30A) 200VDC
JFL (35-60A) 175VDC
JFL (70-600A) 300VDC
Interrupting Rating: 20,000 Amperes DC
BENEFITS:
RECOMMENDED FUSEBLOCKS:
• Space saving dimensions vs Class R.
• Fast-Acting design permits quick response for both over-
loads and shorts.
Refer to page 137 in this catalog.
RECOMMENDED UPGRADE:
JDL.
• Extremely current-limiting.
APPLICATIONS:
• Recommended for protection of non-inductive loads, such
as lighting and resistance heating circuits.
• For motor applications, refer to EDISON JDL.
CROSS REFERENCE
EDISON
BUSSMANN
GOULD
LITTELFUSE
JFL
JKS
A4J
JLS
20
JFL CLASS J FAST-ACTING FUSES
JDL CLASS J TIME-DELAY FUSES
DIMENSIONS
Cat No. JFL and JDL, Class J
Ampere
Rating
Range
1-30
Overall
Length
A
2-1/4
2-3/8
4-5/8
5-3/4
7-1/8
8
Max.
Dia.
B
13/16
1-1/16
1-1/18
1-5/8
2-1/8
2-5/8
Blade
Length
C
–
–
Barrel
Length
D
–
–
2-5/8
3
3-3/8
3-314
Blade
Thickness
E
–
Blade
Width
F
–
–
3/4
1-1/8
1-5/8
2
Mounting Hole Spacing
G
H
J
–
–
K
–
–
–
–
35-60
–
–
–
70-100
110-200
225-400
450-600
1
1/8
3/16
1/4
3/8
1/2
11/16
15/16
1
3-518
4-3/8
5-1/4
6
3/8
3/8
17/32
11/16
9/32
9/32
13/32
17/32
1-3/8
1-7/8
2-1/8
AVERAGE TIME/CURRENT CURVE
Cat. No. JFL (Amp) 600V
CURRENT LIMITATION TABLE**
JFL (600V)
Prosp. Fuse Size
AMPERE
RATING
Short
30
60
IRMS Ip
100
IRMS Ip
200
IRMS Ip
400
IRMS Ip
600
IRMS Ip
300
C.C.
IRMS Ip
200
5,000
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
3
2
3
3
3
4
4
4
4
5
5
5
5
5
5
5
6
1
2
2
2
3
3
3
3
3
3
3
3
4
4
5
5
3
4
4
5
6
6
7
7
8
8
8
8
9
9
11
12
2
3
3
3
3
3
4
4
4
5
5
5
6
6
6
7
4
6
6
7
8
8
9
9
10
11
12
12
13
13
14
15
3
4
4
5
6
6
6
7
7
7
8
8
9
9
9
10
7
9
4
6
7
8
9
9
9
10
10
11
11
12
13
13
14
16
10
5
9
12
10,000
15,000
20,000
25,000
30,000
35,000
40,000
50,000
60,000
70,000
80,000
90,000
100,000
150,000
200,000
13
15
18
19
20
21
22
23
25
25
28
29
30
33
37
19
22
25
28
30
30
32
35
37
39
39
41
42
50
55
10
12
13
13
14
15
16
17
18
18
19
19
21
22
10
11
12
13
13
14
15
16
17
17
18
18
22
24
100
80
60
40
30
20
10
8
6
4
3
2
PEAK LET-THROUGH CURRENT CURVES*
B
1
400,000
.8
JFL (600V)
300,000
.6
200,000
.4
.3
100,000
80,000
60,000
50,000
40,000
600
400
.2
30,000
200
20,000
.1
100
.08
60
10,000
.06
8,000
30
6,000
5,000
.04
.03
4,000
3,000
A
.02
2,000
1,000
.01
RMS SYMMETRICAL CURRENTS IN AMPERES
A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)
RMS SYMMETRICAL CURRENT IN AMPERES
* Curves test data obtained at 15% short-circuit power factor when possible.
** "Apparent Let-Thru Amperes" values are read from "Peak Let-Through Current Curves" and the peak current value divided by 2.3 Asymmetry Factor.
21
相关型号:
©2020 ICPDF网 联系我们和版权申明