MCRW5A [COOPER]

Electric Fuse, Fast Blow, 5A, 125VAC, 125VDC, 50A (IR), Through Hole, MICRO, HALOGEN FREE AND ROHS COMPLIANT;
MCRW5A
型号: MCRW5A
厂家: COOPER BUSSMANN, INC.    COOPER BUSSMANN, INC.
描述:

Electric Fuse, Fast Blow, 5A, 125VAC, 125VDC, 50A (IR), Through Hole, MICRO, HALOGEN FREE AND ROHS COMPLIANT

电路保护
文件: 总2页 (文件大小:248K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HALOGEN  
®
Subminiature Microtron Fuses  
MCRW Series, Fast-Acting, Wire-in-Air  
HF  
FREE  
Description  
• Axial-leaded fast-acting thru-hole fuse  
• Matte tin-plated copper lead wires  
• High temperature epoxy plastic body, UL 94V0  
• Low resistance values  
Electrical Characteristics  
% of Amp Rating  
100%  
Opening Time  
4 hours minimum  
5 seconds maximum  
200%  
Agency Information  
Dimensions - mm (in)  
• UL Recognition Guide & File numbers: JDYX2 &  
3.18 0.1___  
7.1 0.5  
E19180.  
(0.125 0.004)  
“B”  
(0.280 0.020)  
• CSA Certification Record No: LR 701159 & Class No:  
1422 30 and 1422 01.  
“A”  
Environmental Data  
Amps  
“A” Diameter  
0.025"  
Packaging Code  
“B” Length  
1.5"  
• Shock resistance: MIL-STD-202, Method 213B, Test  
100mA - 7A  
10A - 15A  
BK1  
TR1  
Condition I (Sawtooth)  
0.032"  
1.13"  
• Vibration resistance: MIL-STD-202, Method 201  
(10-55Hz x 3 axis/ no load)  
3.18 0.1  
(0.125 0.004)  
diameter  
• Moisture resistance: MIL-STD-202F, Method 106  
• Soldering heat resistance: MIL-STD-202, Method 210  
Top side (260ºC, 20 sec)  
End View  
“A” diameter  
Construction  
• Salt spray: MIL-STD-202, Method 101, Test Condition  
B (48 Hours)  
• Solderability MIL-STD-202, Method 208H  
• Operating Temperating: -55ºC to 125ºC  
Ordering  
• Specify packaging and product code  
(i.e., TR1/MCRW100mA)  
Specifications  
Rating* (amps)  
Voltage  
Rating  
Vac/dc  
125  
Interrupting  
Resistance  
Typical  
Melt  
Typical  
Part Number  
(Ω)**  
Typical  
15.5  
Voltage  
Drop‡  
3.00  
0.61  
0.54  
0.48  
0.43  
0.39  
0.35  
0.31  
0.25  
0.22  
0.18  
0.24  
0.22  
0.20  
0.19  
0.17  
0.15  
0.098  
0.093  
0.088  
2
Vac  
Vdc  
300  
300  
300  
300  
300  
300  
300  
300  
300  
300  
300  
300  
300  
300  
300  
300  
300  
300  
300  
300  
I t†  
MCRW100mA  
MCRW125mA  
MCRW150mA  
MCRW200mA  
MCRW250mA  
MCRW300mA  
MCRW375mA  
MCRW500mA  
MCRW750mA  
MCRW1A  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
0.0006  
0.0009  
0.0015  
0.002  
0.004  
0.008  
0.012  
0.023  
0.056  
0.10  
0.25  
0.27  
0.50  
0.9  
125  
2.2  
125  
1.6  
125  
1.2  
125  
0.85  
125  
0.62  
125  
0.49  
125  
0.33  
125  
0.19  
125  
0.13  
MCRW1.5A  
MCRW2A  
125  
0.07  
125  
0.054  
0.041  
0.031  
0.023  
0.018  
0.012  
0.007  
0.006  
0.004  
MCRW2.5A  
MCRW3A  
125  
125  
MCRW4A  
125  
1.6  
MCRW5A  
125  
3
MCRW7A  
125  
7
MCRW10A  
125  
21  
MCRW12A  
125  
35  
MCRW15A  
125  
63  
*
AC Interrupting Rating (Measured at designated voltage, 100%) DC Interrupting Rating (Measured at designated voltage, rise time of less than 50 microseconds, battery source)  
** DC Cold Resistance (Measured at 10% of rated current)  
2
Typical Melting I t (Measured with a battery bank at rated DC voltage, 10x-rated current, rise time of calibrated circuit less than 50 microseconds)  
Typical Voltage Drop (Measured at rated current after temperature stabilizes)  
0709 BU-SB09024  
Page 1 of 2  
Data Sheet 4074  
Time-Current Curve  
Current in Amps  
Packaging Code  
Packaging Code Prefix  
Description  
BK1  
TR1  
1,000 fuses in bulk  
2,500 fuses on tape-and-reel per EIA-296-F @ 5 mm pitch and 52.4mm inside tape spacing  
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is  
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change  
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained  
in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.  
Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support  
systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in  
significant injury to the user.  
© 2009 Cooper Bussmann  
St. Louis, MO 63178  
www.cooperbussmann.com  
0709 BU-SB09024  
Page 2 of 2  
Data Sheet 4074  

相关型号:

MCRW7A

Electric Fuse, Fast Blow, 7A, 125VAC, 125VDC, 50A (IR), Through Hole, MICRO, HALOGEN FREE AND ROHS COMPLIANT
COOPER

MCR_A

Full line up from ultra small size (01005) to 2512 with jumper type.
ROHM

MCR_G

High reliability metal glazed thick film. ROHM resistors have obtained ISO9001/ISO/TS16949 certification.
ROHM

MCS

Sub-miniature Slide Switches
NIDEC

MCS-068SMA1-TR30

68 CONTACT(S), FEMALE, RIGHT ANGLE PCMCIA CONNECTOR, SURFACE MOUNT, RECEPTACLE
3M

MCS-51

MCS-51 and MCS-96 Packaging Information
INTEL

MCS-96

MCS-51 and MCS-96 Packaging Information
INTEL

MCS-EB1

3-element colour sensor - TO5 with optics
ETC

MCS02EL/CT50.0KHZ

CMOS Output Clock Oscillator,
GOLLEDGE

MCS02EL/EE32.768KHZ

CMOS Output Clock Oscillator,
GOLLEDGE

MCS02EL/VCT10.0KHZ

CMOS Output Clock Oscillator,
GOLLEDGE

MCS02EL/VCT32.768KHZ

CMOS Output Clock Oscillator,
GOLLEDGE