LFA100F-12-GRY [COSEL]

AC-DC Regulated Power Supply Module,;
LFA100F-12-GRY
型号: LFA100F-12-GRY
厂家: COSEL CO., LTD.    COSEL CO., LTD.
描述:

AC-DC Regulated Power Supply Module,

文件: 总18页 (文件大小:665K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
10  
F
-O -O  
5 6  
LFA10F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
6Optional  
Recommended EMI/EMC Filter  
NAC-04-472  
R
LFA  
C: with Coating  
G: Low leakage current  
J1: VH(J.S.T.)connector type  
S : with Chassis  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
SN: with Chassis & cover  
Y: with Potentiometer  
*
The EMI/EMC Filter is recommended  
to connect with several devices.  
Specification is changed at  
option, refer to Instruction  
Manual.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
MODEL  
LFA10F-3R3-Y  
6.6  
LFA10F-5  
10  
LFA10F-12  
10.8  
LFA10F-15  
10.5  
LFA10F-24  
12  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
3.3V 2A  
5V 2A  
12V 0.9A  
15V 0.7A  
24V 0.5A  
SPECIFICATIONS  
MODEL  
LFA10F-3R3-Y  
LFA10F-5  
LFA10F-12  
LFA10F-15  
LFA10F-24  
*3  
VOLTAGE[V]  
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)  
ACIN 100V 0.18typ (Io=100%)  
0.26typ (Io=100%)  
0.16typ (Io=100%)  
CURRENT[A]  
ACIN 200V 0.11typ (Io=100%)  
50 / 60 (47 - 440)  
FREQUENCY[Hz]  
INPUT  
ACIN 100V 68.0typ  
74.0typ  
76.0typ  
76.5typ  
79.0typ  
77.5typ  
80.0typ  
79.5typ  
83.0typ  
EFFICIENCY[%]  
ACIN 200V 68.5typ  
ACIN 100V 15typ (Io=100%)  
ACIN 200V 30typ (Io=100%)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
3.3  
5
12  
15  
24  
CURRENT[A]  
2.0  
2.0  
0.9  
0.7  
0.5  
*
5
5
20max  
40max  
20max  
40max  
80max  
140max  
160max  
120max  
160max  
240max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
240max  
150max  
180max  
300max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
240max  
150max  
180max  
300max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
280max  
150max  
180max  
320max  
240max  
290max  
96max  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
*
0 to +50C 80max  
-10 - 0C 140max  
Io=0 - 35% 190max  
0 to +50C 120max  
-10 - 0C 160max  
Io=0 - 35% 240max  
0 to +50C 50max  
-10 to +50C 60max  
RIPPLE[mVp-p]  
*1  
RIPPLE NOISE[mVp-p]  
OUTPUT  
*1  
TEMPERATURE REGULATION[mV]  
*2  
20max  
DRIFT[mV]  
START-UP TIME[ms]  
200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.  
HOLD-UP TIME[ms]  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION  
OVERVOLTAGE PROTECTION  
2.85 to 3.63  
3.30 to 3.40  
Fixed (“Y”option is available for adjusting output voltage between ±10%)  
4.90 to 5.30  
11.50 to 12.50  
14.40 to 15.60  
23.00 to 25.00  
27.60 to 33.60  
Works over 105% of rating and recovers automatically  
4.00 to 5.25  
Not provided  
Not provided  
Not provided  
5.75 to 7.00  
13.80 to 16.80  
17.25 to 21.00  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
ISOLATION  
INPUT-FG  
OUTPUT-FG  
*3  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE  
VIBRATION  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max  
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max  
ENVIRONMENT  
2
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*6  
*4  
(Not built-in to active filter)  
Complies with IEC61000-3-2 (Class A)  
50X22X73.5mm [1.97X0.87X2.89 inches] (WXHXD) / 55g max (with chassis & cover : 150g max)  
OTHERS  
*3  
Convection (Refer to Instruction Manual 3.1 and 3.2)  
*1  
This is the value that measured on measuring board with  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
factor Io=0-35% is different.  
Please contact us for details.  
Please refer to the Instruction Manual 1.7.  
Drift is the change in DC output for an eight hour period after  
a half-hour warm-up at 25C, with the input voltage held  
constant at the rated input/output.  
*5  
*6  
*
Please contact us about dynamic load and input response.  
Please contact us about another class.  
*2  
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
A circuit reducing standby power is built in this unit.  
Therefore, the internal switch element is intermittent  
operated, and the Ripple/Ripple Noise specification in load  
*
*3  
*4  
Derating is required.  
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse  
load.  
When two or more units are operating it may not comply with  
the IEC61000-3-2.  
*
LFA-2  
LFA10F  
Block diagram  
FUSE  
AC250V  
2A  
INRUSH  
CURRENT  
LIMIT  
RECTIFIER  
AND  
FILTER  
AC IN  
85 264V  
NOISE  
FILTER  
LFA  
FG  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
CURRENT  
SENSING  
Photocoupler  
Photocoupler  
CONTROL  
OVER VOLTAGE  
PROTECTION  
External view  
Standard type  
Chassis and cover type  
FG  
4.6  
[0.18]  
0.5  
f3.5  
83.5  
[3.29]  
4-M3  
5
[0.2]  
Mounting Hole  
CN2  
CN1  
5
FG  
1
2
Output(-)  
Output(+)  
3
Input(N)  
Input(L)  
Voltage adjust  
(LFA10F-3R3-Y or optional)  
1
Output(-)  
Output(+)  
CN1  
CN2  
1
2
5
FG  
Input(N)  
Input(L)  
2-  
f3.5  
3
1
Mounting Hole  
0.5  
63.5  
[2.5]  
5
[0.2]  
Name plate  
73.5  
[2.89]  
Point A  
Point B  
93.5  
[3.68]  
0.5  
f3.5  
5
83.5  
[3.29]  
[0.2]  
1  
PCB t=1.6  
1 Surface mount device  
2-M3  
Mounting Hole  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN1  
CN2  
Tolerance : 1 [ 0.04]  
Weight : 55g max (with chassis & cover : 150g max)  
PCB material / thickness : CEM3 / 1.6mm  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-2 1-1123722-2  
1
2
-V  
AC(N)  
FG  
+V  
Mounting torque (Mounting hole of chassis) : 0.6N-m (6.3kgf-cm) max  
(Mfr:Tyco Electronics)  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.  
LFA-3  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
15  
F
-O -O  
5 6  
LFA15F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
6Optional  
Recommended EMI/EMC Filter  
NAC-04-472  
R
LFA  
C: with Coating  
G: Low leakage current  
J1: VH(J.S.T.)connector type  
S : with Chassis  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
SN: with Chassis & cover  
Y: with Potentiometer  
*
The EMI/EMC Filter is recommended  
to connect with several devices.  
Specification is changed at  
option, refer to Instruction  
Manual.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
MODEL  
LFA15F-3R3-Y  
9.9  
LFA15F-5  
15  
LFA15F-12  
15.6  
LFA15F-15  
15  
LFA15F-24  
16.8  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
3.3V 3A  
5V 3A  
12V 1.3A  
15V 1A  
24V 0.7A  
SPECIFICATIONS  
MODEL  
LFA15F-3R3-Y  
LFA15F-5  
LFA15F-12  
LFA15F-15  
LFA15F-24  
*3  
VOLTAGE[V]  
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)  
ACIN 100V 0.24typ (Io=100%)  
0.35typ (Io=100%)  
0.20typ (Io=100%)  
CURRENT[A]  
ACIN 200V 0.15typ (Io=100%)  
50 / 60 (47 - 440)  
FREQUENCY[Hz]  
INPUT  
ACIN 100V 68.0typ  
73.0typ  
76.0typ  
76.0typ  
78.5typ  
77.0typ  
80.0typ  
78.0typ  
81.5typ  
EFFICIENCY[%]  
ACIN 200V 69.0typ  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
3.3  
5
12  
15  
24  
CURRENT[A]  
3.0  
3.0  
1.3  
1.0  
0.7  
*
5
5
20max  
40max  
20max  
40max  
80max  
140max  
160max  
120max  
160max  
240max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
240max  
150max  
180max  
300max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
240max  
150max  
180max  
300max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
280max  
150max  
180max  
320max  
240max  
290max  
96max  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
*
0 to +50C 80max  
-10 - 0C 140max  
Io=0 - 35% 190max  
0 to +50C 120max  
-10 - 0C 160max  
Io=0 - 35% 240max  
0 to +50C 50max  
-10 to +50C 60max  
RIPPLE[mVp-p]  
*1  
RIPPLE NOISE[mVp-p]  
OUTPUT  
*1  
TEMPERATURE REGULATION[mV]  
*2  
20max  
DRIFT[mV]  
START-UP TIME[ms]  
200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.  
HOLD-UP TIME[ms]  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION  
OVERVOLTAGE PROTECTION  
2.85 to 3.63  
3.30 to 3.40  
Fixed (“Y”option is available for adjusting output voltage between ±10%)  
4.90 to 5.30  
11.50 to 12.50  
14.40 to 15.60  
23.00 to 25.00  
27.60 to 33.60  
Works over 105% of rating and recovers automatically  
4.00 to 5.25  
Not provided  
Not provided  
Not provided  
5.75 to 7.00  
13.80 to 16.80  
17.25 to 21.00  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
ISOLATION  
INPUT-FG  
OUTPUT-FG  
*3  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE  
VIBRATION  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max  
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max  
ENVIRONMENT  
2
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*6  
*4  
(Not built-in to active filter)  
Complies with IEC61000-3-2 (Class A)  
50X22X87.5mm [1.97X0.87X3.44 inches] (WXHXD) / 80g max (with chassis & cover : 190g max)  
OTHERS  
*3  
Convection (Refer to Instruction Manual 3.1 and 3.2)  
*1  
This is the value that measured on measuring board with  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
factor Io=0-35% is different.  
Please contact us for details.  
Please refer to the Instruction Manual 1.7.  
Drift is the change in DC output for an eight hour period after  
a half-hour warm-up at 25C, with the input voltage held  
constant at the rated input/output.  
*5  
*6  
*
Please contact us about dynamic load and input response.  
Please contact us about another class.  
*2  
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
A circuit reducing standby power is built in this unit.  
Therefore, the internal switch element is intermittent  
operated, and the Ripple/Ripple Noise specification in load  
*
*3  
*4  
Derating is required.  
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse  
load.  
When two or more units are operating it may not comply with  
the IEC61000-3-2.  
*
LFA-4  
LFA15F  
Block diagram  
FUSE  
AC250V  
2.5A  
INRUSH  
CURRENT  
LIMIT  
RECTIFIER  
AND  
FILTER  
AC IN  
85 264V  
NOISE  
FILTER  
LFA  
FG  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
CURRENT  
SENSING  
Photocoupler  
Photocoupler  
CONTROL  
OVER VOLTAGE  
PROTECTION  
External view  
Standard type  
Chassis and cover type  
FG  
4.4  
[0.17]  
0.5  
97.5  
[3.84]  
5
[0.2]  
f3.5  
4-M3  
Mounting Hole  
CN2  
CN1  
5
1
2
Output(-)  
Output(+)  
FG  
3
Input(N)  
Output(-)  
Output(+)  
CN1  
5
CN2  
1
2
Voltage adjust  
(LFA15F-3R3-Y or optional)  
1
Input(L)  
FG  
Input(N)  
Input(L)  
3
1
2-  
f3.5  
0.5  
Mounting Hole  
77.5  
[3.05]  
87.5  
[3.44]  
5
[0.2]  
Name plate  
107.5  
[4.23]  
97.5  
[3.84]  
Point A  
Point B  
f3.5  
0.5  
5
[0.2]  
PCB t=1.6  
1  
2-M3  
Mounting Hole  
1 Surface mount device  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN1  
CN2  
Tolerance : 1 [ 0.04]  
Weight : 80g max (with chassis & cover : 190g max)  
PCB material / thickness : CEM3 / 1.6mm  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-2 1-1123722-2  
1
2
-V  
AC(N)  
FG  
+V  
Mounting torque (Mounting hole of chassis) : 0.6N  
-
m (6.3kgf  
-
cm) max  
(Mfr:Tyco Electronics)  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.  
LFA-5  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
30  
F
-O -O  
5 6  
LFA30F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
6Optional  
Recommended EMI/EMC Filter  
NAC-04-472  
R
LFA  
C: with Coating  
G: Low leakage current  
J1: VH(J.S.T.)connector type  
S : with Chassis  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
SN: with Chassis & cover  
Y: with Potentiometer  
*
The EMI/EMC Filter is recommended  
to connect with several devices.  
Specification is changed at  
option, refer to Instruction  
Manual.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
MODEL  
LFA30F-3R3-Y  
19.8  
LFA30F-5  
30.0  
LFA30F-12  
30.0  
LFA30F-15  
30.0  
LFA30F-24  
31.2  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
3.3V 6A  
5V 6A  
12V 2.5A  
15V 2A  
24V 1.3A  
SPECIFICATIONS  
MODEL  
LFA30F-3R3-Y  
LFA30F-5  
LFA30F-12  
LFA30F-15  
LFA30F-24  
*3  
VOLTAGE[V]  
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)  
ACIN 100V 0.50typ (Io=100%)  
0.65typ (Io=100%)  
0.35typ (Io=100%)  
CURRENT[A]  
ACIN 200V 0.30typ (Io=100%)  
50 / 60 (47 - 440)  
ACIN 100V 73typ  
FREQUENCY[Hz]  
INPUT  
76typ  
79typ  
79typ  
81typ  
81typ  
83typ  
82typ  
84typ  
EFFICIENCY[%]  
ACIN 200V 75typ  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.30 / 0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
3.3  
5
12  
15  
24  
CURRENT[A]  
6.0  
6.0  
2.5  
2.0  
1.3  
*5  
*5  
*1  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
0 to +50C  
RIPPLE[mVp-p]  
*1  
*1  
-10 - 0C  
0 to +50C  
RIPPLE NOISE[mVp-p]  
*1  
OUTPUT  
-10 - 0C  
0 to +50C 50max  
TEMPERATURE REGULATION[mV]  
-10 to +50  
C
60max  
2
20max  
*
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
150typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
2.85 to 3.63  
3.30 to 3.40  
Fixed (“Y”option is available for adjusting output voltage between ±10%)  
OUTPUT VOLTAGE SETTING[V]  
4.90 to 5.30  
11.50 to 12.50  
14.40 to 15.60  
23.00 to 25.00  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80  
17.25 to 21.00  
27.60 to 33.60  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
Not provided  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
ISOLATION INPUT-FG  
OUTPUT-FG  
*3  
OPERATING TEMP.,HUMID.AND ALTITUDE  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*6  
*4  
(Not built-in to active filter)  
Complies with IEC61000-3-2 (Class A)  
50X26.5X105mm [1.97X1.04X4.13 inches] (WXHXD) / 130g max (with chassis & cover : 260g max)  
OTHERS  
*3  
Convection (Refer to Instruction Manual 3.1 and 3.2)  
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm  
from output terminal.  
*4 When two or more units are operating it may not comply with the IEC61000-3-2.  
Please contact us for details.  
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:  
RM103).  
*5 Please contact us about dynamic load and input response.  
*6 Please contact us about another class.  
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at  
25C, with the input voltage held constant at the rated input/output.  
*3 Derating is required.  
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse load.  
LFA-6  
LFA30F  
Block diagram  
FUSE  
AC250V  
3.15A  
INRUSH  
CURRENT  
LIMIT  
RECTIFIER  
AND  
FILTER  
AC IN  
85 264V  
NOISE  
FILTER  
LFA  
FG  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
CURRENT  
SENSING  
Photocoupler  
Photocoupler  
CONTROL  
OVER VOLTAGE  
PROTECTION  
External view  
Standard type  
Chassis and cover type  
3-  
f3.5  
4.5  
[0.18]  
Name plate  
FG  
Mounting Hole  
0.5  
5
[0.2]  
f3.5  
4-M3  
115  
[4.53]  
Mounting Hole  
CN2  
5
FG  
1
2
3
4
Output(-)  
Output(+)  
3
Input(N)  
Input(L)  
CN2  
1
5
3
FG  
1
2
3
4
Output(-)  
CN1  
Input(N)  
Input(L)  
Output(+)  
1
CN1  
4
[0.16]  
Voltage adjust  
(LFA30F-3R3-Y or optional)  
0.5  
5
[0.2]  
95  
[3.74]  
105  
Mounting Hole  
[4.13]  
Point A  
Point B  
125  
[4.92]  
0.5  
f3.5  
115  
[4.53]  
5
[0.2]  
PCB t=1.6  
1  
2-M3  
Mounting Hole  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN1  
CN2  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Tolerance : 1 [ 0.04]  
Weight: 130g max (with chassis & cover : 260g max)  
PCB material / thickness : CEM3 / 1.6mm  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-4 1-1123722-4  
1, 2  
3, 4  
-V  
AC(N)  
FG  
+V  
(Mfr:Tyco Electronics)  
Mounting torque (Mounting hole of chassis) : 0.6N  
-
m (6.3kgf  
-
cm) max  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.  
Keep drawing current per pin below 5A for CN2.  
LFA-7  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
50  
F
-O -O  
5 6  
LFA50F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
6Optional  
Recommended EMI/EMC Filter  
NAC-04-472  
R
LFA  
C: with Coating  
G: Low leakage current  
J1: VH(J.S.T.)connector type  
S : with Chassis  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
SN: with Chassis & cover  
Y: with Potentiometer  
*
The EMI/EMC Filter is recommended  
to connect with several devices.  
Specification is changed at  
option, refer to Instruction  
Manual.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
MODEL  
LFA50F-3R3-Y LFA50F-5  
LFA50F-12  
51.6  
LFA50F-15  
52.5  
LFA50F-24  
50.4  
LFA50F-36  
50.4  
LFA50F-48  
52.8  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
33  
50  
3.3V 10A  
5V 10A  
12V 4.3A  
15V 3.5A  
24V 2.1A  
36V 1.4A  
48V 1.1A  
SPECIFICATIONS  
MODEL  
LFA50F-3R3-Y LFA50F-5  
LFA50F-12  
LFA50F-15  
LFA50F-24  
LFA50F-36  
LFA50F-48  
*3  
VOLTAGE[V]  
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)  
ACIN 100V 0.47typ (Io=100%) 0.67typ (Io=100%)  
ACIN 200V 0.27typ (Io=100%) 0.36typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
ACIN 100V 73.5typ  
ACIN 200V 74.0typ  
ACIN 100V 0.96typ  
ACIN 200V 0.83typ  
77.5typ  
79.0typ  
0.97typ  
0.90typ  
80.0typ  
81.5typ  
80.5typ  
81.5typ  
81.5typ  
83.0typ  
82.0typ  
83.5typ  
81.0typ  
82.5typ  
EFFICIENCY[%]  
INPUT  
POWER FACTOR (Io=100%)  
INRUSH CURRENT[A]  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
3.3  
5
12  
15  
24  
36  
48  
CURRENT[A]  
10.0  
10.0  
4.3  
3.5  
2.1  
1.4  
1.1  
*4  
*4  
*1  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
0 to +50C  
RIPPLE[mVp-p]  
*1  
-10 - 0C  
*1  
0 to +50C  
RIPPLE NOISE[mVp-p]  
*1  
OUTPUT  
-10 - 0C  
0 to +50C 50max  
TEMPERATURE REGULATION[mV]  
-10 to +50  
C
60max  
2
20max  
*
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
2.85 to 3.63  
3.30 to 3.40  
Fixed (“Y”option is available for adjusting output voltage between ±10%)  
OUTPUT VOLTAGE SETTING[V]  
4.90 to 5.30  
11.50 to 12.50  
14.40 to 15.60  
23.00 to 25.00  
34.50 to 37.50  
46.00 to 50.00  
55.20 to 67.20  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00  
27.60 to 33.60  
41.40 to 50.40  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
Not provided  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
ISOLATION INPUT-FG  
OUTPUT-FG  
*3  
OPERATING TEMP.,HUMID.AND ALTITUDE  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*5  
Complies with IEC61000-3-2 (Class A)  
50X26.5X132mm [1.97X1.04X5.20 inches] (WXHXD) / 165g max (with chassis & cover : 325g max)  
OTHERS  
*3  
Convection (Refer to Instruction Manual 3.1 and 3.2)  
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm  
from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:  
RM103).  
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at  
25C, with the input voltage held constant at the rated input/output.  
*3 Derating is required.  
*4 Please contact us about dynamic load and input response.  
*5 Please contact us about another class.  
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse load.  
LFA-8  
LFA50F  
Block diagram  
FUSE  
250V2.5A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
AC IN 85 264V  
RECTIFIER  
LFA  
FG  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
BOOSTER  
CURRENT  
INDUCTOR  
SENSING  
RECTIFIER  
AND  
CURRENT  
SENSING  
FILTER  
Photocoupler  
Photocoupler  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
CONTROL  
External view  
Standard type  
Voltage adjust  
Chassis and cover type  
4-M3  
2-f3.5  
0.5  
3-  
f3.5  
150  
6
[0.24]  
4.9  
[0.19]  
Name plate  
FG  
(LFA50F-3R3-Y or optional)  
[5.91]  
Mounting Hole  
Mounting Hole  
5
FG  
5
3
FG  
Input(N)  
Input(L)  
3
Input(N)  
Input(L)  
1
2
3
4
Output(-)  
Output(+)  
CN2  
1
1
2
3
4
1
CN1  
Output(-)  
Output(+)  
CN1  
CN2  
4
Point A  
Point B  
[0.16]  
Mounting Hole  
0.5  
5
122  
[4.8]  
132  
[0.2]  
162  
[6.38]  
[5.2]  
0.5  
f3.5  
150  
[5.91]  
6
[0.24]  
PCB t=1.6  
2-M3  
1  
Mounting Hole  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN1  
CN2  
Tolerance : 1 [ 0.04]  
Weight : 165g max (with chassis & cover : 325g max)  
PCB material / thickness : CEM3 / 1.6mm  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-4 1-1123722-4  
1, 2  
3, 4  
-V  
AC(N)  
FG  
+V  
Mounting torque (Mounting hole of chassis) : 0.6N  
-
m (6.3kgf  
-
cm) max  
(Mfr:Tyco Electronics)  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.  
Keep drawing current per pin below 5A for CN2.  
LFA-9  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
75  
F
-O -O  
5 6  
LFA75F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
6Optional  
Recommended EMI/EMC Filter  
NAC-04-472  
R
LFA  
C: with Coating  
G: Low leakage current  
J1: VH(J.S.T.)connector type  
S : with Chassis  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
SN: with Chassis & cover  
Y: with Potentiometer  
*
The EMI/EMC Filter is recommended  
to connect with several devices.  
Specification is changed at  
option, refer to Instruction  
Manual.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
MODEL  
LFA75F-3R3-Y LFA75F-5  
LFA75F-12  
75.6  
LFA75F-15  
75  
LFA75F-24  
76.8  
LFA75F-36  
75.6  
LFA75F-48  
76.8  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
49.5  
75  
3.3V 15A  
5V 15A  
12V 6.3A  
15V 5A  
24V 3.2A  
36V 2.1A  
48V 1.6A  
SPECIFICATIONS  
MODEL  
LFA75F-3R3-Y LFA75F-5  
LFA75F-12  
LFA75F-15  
LFA75F-24  
LFA75F-36  
LFA75F-48  
*3  
VOLTAGE[V]  
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)  
ACIN 100V 0.70typ (Io=100%) 1.00typ (Io=100%)  
ACIN 200V 0.40typ (Io=100%) 0.50typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
ACIN 100V 73.5typ  
ACIN 200V 75.0typ  
ACIN 100V 0.96typ  
ACIN 200V 0.83typ  
78.0typ  
80.0typ  
0.97typ  
0.90typ  
81.5typ  
83.0typ  
81.5typ  
83.0typ  
82.5typ  
84.5typ  
82.5typ  
84.5typ  
82.5typ  
84.5typ  
EFFICIENCY[%]  
INPUT  
POWER FACTOR (Io=100%)  
INRUSH CURRENT[A]  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
3.3  
5
12  
15  
24  
36  
48  
CURRENT[A]  
15.0  
15.0  
6.3  
5.0  
3.2  
2.1  
1.6  
*4  
*4  
*1  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
0 to +50C  
RIPPLE[mVp-p]  
*1  
-10 - 0C  
*1  
0 to +50C  
RIPPLE NOISE[mVp-p]  
*1  
OUTPUT  
-10 - 0C  
0 to +50C 50max  
TEMPERATURE REGULATION[mV]  
-10 to +50  
C
60max  
2
20max  
*
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
2.85 to 3.63  
3.30 to 3.40  
Fixed (“Y”option is available for adjusting output voltage between ±10%)  
OUTPUT VOLTAGE SETTING[V]  
4.90 to 5.30  
11.50 to 12.50  
14.40 to 15.60  
23.00 to 25.00  
34.50 to 37.50  
46.00 to 50.00  
55.20 to 67.20  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00  
27.60 to 33.60  
41.40 to 50.40  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
Not provided  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
ISOLATION INPUT-FG  
OUTPUT-FG  
*3  
OPERATING TEMP.,HUMID.AND ALTITUDE  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*5  
Complies with IEC61000-3-2 (Class A)  
50X33.5X150mm [1.97X1.32X5.91 inches] (WXHXD) / 230g max (with chassis & cover : 440g max)  
OTHERS  
*3  
Convection (Refer to Instruction Manual 3.1 and 3.2)  
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm  
from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:  
RM103).  
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at  
25C, with the input voltage held constant at the rated input/output.  
*3 Derating is required.  
*4 Please contact us about dynamic load and input response.  
*5 Please contact us about another class.  
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse load.  
LFA-10  
LFA75F  
Block diagram  
FUSE  
250V3.15A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
AC IN 85 264V  
RECTIFIER  
LFA  
FG  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CURRENT  
SENSING  
Photocoupler  
Photocoupler  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
CONTROL  
External view  
Standard type  
Chassis and cover type  
3-  
f3.5  
Voltage adjust  
(LFA75F-3R3-Y or optional)  
13  
[0.51]  
Name plate  
FG  
2-f4.5  
0.5  
4-M4  
Mounting Hole  
5.5  
[0.22]  
169  
[6.65]  
Mounting Hole  
5
FG  
CN2  
CN2  
1
5
3
FG  
Input(N)  
Input(L)  
3
Input(N)  
Input(L)  
Output(-)  
Output(+)  
1
3
4
Output(-)  
1
3
4
CN1  
1
6
Output(+)  
CN1  
6
4
Point A  
Point B  
[0.16]  
0.5  
Mounting Hole  
5
[0.2]  
140  
[5.51]  
150  
[5.91]  
180  
[7.09]  
0.5  
f4.5  
169  
[6.65]  
5.5  
[0.22]  
2-M4  
Mounting Hole  
1  
PCB t=1.6  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN1  
CN2  
Tolerance : 1 [ 0.04]  
Weight : 230g max (with chassis & cover : 440g max)  
PCB material / thickness : CEM3 / 1.6mm  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-6 1-1123722-6  
1 to 3  
4 to 6  
-V  
AC(N)  
FG  
+V  
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max  
(Mfr:Tyco Electronics)  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.  
Keep drawing current per pin below 5A for CN2.  
LFA-11  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
100  
F
-O -O  
5 6  
LFA100F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Recommended EMI/EMC Filter  
NAC-04-472  
R
LFA  
*1  
6Optional  
C: with Coating  
G: Low leakage current  
H: with the function to be acceptable  
to output peak current (only 24V)  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
J1: VH(J.S.T.)connector type  
*
The EMI/EMC Filter is recommended  
R: with Remote ON/OFF  
R2: with Remote ON/OFF  
S : with Chassis  
to connect with several devices.  
SN: with Chassis & cover  
Y: with Potentiometer  
Please refer to Instruction  
manual 5.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,  
so handle the unit with care.  
MODEL  
LFA100F-3R3-Y LFA100F-5-Y LFA100F-12 LFA100F-15 LFA100F-24 LFA100F-24-H LFA100F-36 LFA100F-48  
*5  
*5  
66  
100  
102  
100.5  
103.2  
103.2 (129.6)  
100.8  
100.8  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
3.3V 20A  
5V 20A  
12V 8.5A  
15V 6.7A  
24V 4.3A  
24V 4.3 (5.4)A 36V 2.8A  
48V 2.1A  
SPECIFICATIONS  
MODEL  
LFA100F-3R3-Y LFA100F-5-Y LFA100F-12 LFA100F-15 LFA100F-24 LFA100F-24-H LFA100F-36 LFA100F-48  
*4  
VOLTAGE[V]  
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)  
ACIN 100V 0.9typ (Io=100%)  
ACIN 200V 0.5typ (Io=100%)  
1.3typ (Io=100%)  
0.7typ (Io=100%)  
CURRENT[A]  
FREQUENCY[Hz]  
50 / 60 (47 - 63)  
ACIN 100V 77.0typ  
ACIN 200V 79.0typ  
ACIN 100V 0.98typ  
ACIN 200V 0.92typ  
82.0typ  
84.0typ  
0.99typ  
0.95typ  
82.0typ  
84.5typ  
83.0typ  
85.5typ  
84.0typ  
87.0typ  
84.0typ  
87.0typ  
84.0typ  
87.0typ  
84.5typ  
87.0typ  
EFFICIENCY[%]  
INPUT  
POWER FACTOR (Io=100%)  
INRUSH CURRENT[A]  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
3.3  
5
12  
15  
24  
24  
36  
48  
*5  
*7  
*7  
*2  
20  
20  
8.5  
6.7  
4.3  
4.3 (Peak 5.4)  
96max  
2.8  
2.1  
CURRENT[A]  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
150max  
240max  
320max  
300max  
360max  
240max  
290max  
96max  
0 to +50C  
RIPPLE[mVp-p]  
*2  
-10 - 0C  
*2  
0 to +50C  
RIPPLE NOISE[mVp-p]  
*2  
OUTPUT  
-10 - 0C  
0 to +50C 50max  
TEMPERATURE REGULATION[mV]  
-10 to +50  
C
60max  
3
20max  
*
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
2.85 to 3.63 4.50 to 5.50 Fixed (“Y”option is available for adjusting output voltage)  
3.30 to 3.40 5.00 to 5.15 11.50 to 12.50 14.40 to 15.60  
OUTPUT VOLTAGE SETTING[V]  
23.00 to 25.00  
23.00 to 25.00  
34.50 to 37.50  
46.00 to 50.00  
55.20 to 67.20  
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00  
27.60 to 33.60  
27.60 to 33.60  
41.40 to 50.40  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
Not provided  
Option (Refer to Instruction Manual)  
.
*6  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)  
INPUT-OUTPUT RC  
INPUT-FG  
ISOLATION  
.
*6  
*6  
*4  
OUTPUT RC-FG  
OUTPUT-RC  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*8  
Complies with IEC61000-3-2 (Class A)  
62X33.5X155mm [2.44X1.32X6.10 inches] (WXHXD) / 280g max (with chassis & cover : 480g max)  
OTHERS  
*4  
Convection (Refer to Instruction Manual 3.1 and 3.2)  
*1 Specification is changed at option, refer to Instruction Manual.  
at the rated input/output.  
*8 Please contact us about another class.  
*2 This is the value that measured on measuring board with *4 Derating is required.  
*
To meet the specifications. Do not operate over-loaded  
condition.  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
*5 ( ) means peak current. There is a possibility that an internal  
device is damaged when the specification is exceeded. Please *  
Parallel operation is not possible.  
contact us about the detail.  
*
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of  
pulse load.  
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when Remote ON/OFF (optional) is added.  
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.  
LFA-12  
LFA100F  
Block diagram  
FUSE  
250V3.15A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
LFA  
FG  
Photocoupler  
OPTION  
CURRENT  
SENSING  
RC  
E
EXTERNAL  
SOURCE  
Photocoupler  
Photocoupler  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CONTROL  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
INVERTER  
CONTROL  
RECTIFIER  
AND  
TRANSFORMER  
DC OUT  
FILTER  
External view  
External size of option is different from standard model.  
Standard type  
Chassis and cover type  
173 0.5  
[6.81]  
6
[0.24]  
4-M4  
Mounting Hole  
2-f4.5  
Connector for  
Remote ON/OFF  
(Optional)  
Name plate  
3-f3.5  
Mounting Hole  
FG  
1
2
1
2
CN4  
CN2  
Output(-)  
FG  
FG  
5
5
3
CN2  
1
1
3
Input(N)  
Input(N)  
Input(L)  
Output(-)  
1
1
4
5
Input(L)  
4
5
CN1  
CN1  
Output(+)  
Output(+)  
8
8
4
Point A  
Point B  
[0.16]  
16.5  
[0.65]  
Voltage adjust  
(LFA100F-3R3-Y,LFA100F-5-Y or Optional)  
Mounting Hole  
185  
[7.28]  
173 0.5  
5
[0.2]  
145 0.5  
[5.71]  
155  
6
f4.5  
[6.81]  
[0.24]  
[6.1]  
2-M4  
Mounting Hole  
PCB t=1.6  
1  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Connector type  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN4 Option (Mfr:J.S.T)  
CN1  
CN2  
PIN No.  
Contents  
RC(+)  
Pin No.  
Input  
Pin No. Output  
1
2
AC(L)  
1
2
3
4
5
1 to 4  
5 to 8  
-V  
+V  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
RC(-)  
Chain  
Loose  
Chain  
Loose  
AC(N)  
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-8 1-1123722-8  
Barrier strip type  
Model B2B-XH-A  
Mating Connector (Terminal)  
XHP-2  
FG  
(Mfr:Tyco Electronics)  
Keep drawing current per pin below 5A for CN2.  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:VH(J.S.T) connector type.  
BXH-001T-P0.6  
or SXH-001T-P0.6  
Tolerance : 1 [ 0.04]  
Weight : 280g max (with chassis & cover : 480g max)  
PCB material : CEM3  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max  
LFA-13  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
150  
F
-O -O  
5 6  
LFA150F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Recommended EMI/EMC Filter  
NAC-04-472  
R
LFA  
*1  
6Optional  
C: with Coating  
G: Low leakage current  
H: with the function to be acceptable  
to output peak current (only 24V)  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
J1: VH(J.S.T.)connector type  
*
The EMI/EMC Filter is recommended  
R: with Remote ON/OFF  
R2: with Remote ON/OFF  
S : with Chassis  
to connect with several devices.  
SN: with Chassis & cover  
Y: with Potentiometer  
Please refer to Instruction  
manual 5.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,  
so handle the unit with care.  
MODEL  
LFA150F-3R3-Y LFA150F-5-Y LFA150F-12 LFA150F-15 LFA150F-24 LFA150F-24-H LFA150F-36 LFA150F-48  
*5  
*5  
99  
150  
150  
150  
151.2  
151.2 (189.6) 151.2  
153.6  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
3.3V 30A  
5V 30A  
12V 12.5A  
15V 10A  
24V 6.3A  
24V 6.3 (7.9)A 36V 4.2A  
48V 3.2A  
SPECIFICATIONS  
MODEL  
LFA150F-3R3-Y LFA150F-5-Y LFA150F-12 LFA150F-15 LFA150F-24 LFA150F-24-H LFA150F-36 LFA150F-48  
*4  
VOLTAGE[V]  
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)  
ACIN 100V 1.4typ  
ACIN 200V 0.7typ  
(
Io=100%)  
Io=100%)  
2.0typ (Io=100%)  
1.0typ (Io=100%)  
CURRENT[A]  
(
FREQUENCY[Hz]  
50 / 60 (47 - 63)  
ACIN 100V 80.0typ  
82.5typ  
85.5typ  
0.99typ  
0.95typ  
82.5typ  
85.0typ  
84.0typ  
86.5typ  
85.0typ  
87.5typ  
85.0typ  
87.5typ  
85.0typ  
87.5typ  
85.5typ  
88.0typ  
EFFICIENCY[%]  
INPUT  
ACIN 200V 82.0typ  
ACIN 100V 0.98typ  
ACIN 200V 0.92typ  
POWER FACTOR (Io=100%)  
INRUSH CURRENT[A]  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
3.3  
5
12  
15  
24  
24  
36  
48  
*5  
*7  
*7  
*2  
30  
30  
12.5  
10  
6.3  
6.3 (Peak 7.9)  
96max  
4.2  
3.2  
CURRENT[A]  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
150max  
240max  
320max  
300max  
360max  
240max  
290max  
96max  
0 to +40C  
RIPPLE[mVp-p]  
*2  
*2  
-10 - 0C  
0 to +40C  
RIPPLE NOISE[mVp-p]  
*2  
OUTPUT  
-10 - 0C  
0 to +40C 50max  
TEMPERATURE REGULATION[mV]  
-10 to +40  
C
60max  
3
20max  
*
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
2.85 to 3.63 4.50 to 5.50 Fixed (“Y”option is available for adjusting output voltage)  
3.30 to 3.40 5.00 to 5.15 11.50 to 12.50 14.40 to 15.60  
OUTPUT VOLTAGE SETTING[V]  
23.00 to 25.00  
23.00 to 25.00  
34.50 to 37.50  
46.00 to 50.00  
55.20 to 67.20  
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00  
27.60 to 33.60  
27.60 to 33.60  
41.40 to 50.40  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
Not provided  
Option (Refer to Instruction Manual)  
.
*6  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)  
INPUT-OUTPUT RC  
INPUT-FG  
ISOLATION  
.
*6  
*6  
*4  
OUTPUT RC-FG  
OUTPUT-RC  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*8  
Complies with IEC61000-3-2 (Class A)  
75X37.0X160mm [2.95X1.46X6.30 inches] (WXHXD) / 390g max (with chassis & cover : 650g max)  
OTHERS  
*4  
Convection (Refer to Instruction Manual 3.1 and 3.2)  
*1 Specification is changeed at option, refer to Instruction Manual.  
at the rated input/output.  
*8 Please contact us about another class.  
*2 This is the value that measured on measuring board with *4 Derating is required.  
*
To meet the specifications. Do not operate over-loaded  
condition.  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
*5 ( ) means peak current. There is a possibility that an internal  
device is damaged when the specification is exceeded. Please *  
Parallel operation is not possible.  
contact us about the detail.  
*
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of  
pulse load.  
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when remote control (optional) is added.  
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.  
LFA-14  
LFA150F  
Block diagram  
FUSE  
250V5A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
LFA  
FG  
Photocoupler  
OPTION  
CURRENT  
SENSING  
RC  
E
EXTERNAL  
SOURCE  
Photocoupler  
Photocoupler  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CONTROL  
INVERTER  
CONTROL  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
RECTIFIER  
AND  
FILTER  
TRANSFORMER  
DC OUT  
External view  
External size of option is different from standard model.  
Standard type  
Chassis and cover type  
6
2-f4.5  
176 0.5  
[6.93]  
4-M4  
Mounting Hole  
FG  
Name plate  
3-f3.5  
Mounting Hole  
Point A  
Point B  
[0.24]  
1
1
FG  
5
3
FG  
Input(N)  
Input(L)  
5
3
CN3  
CN3  
Input(N)  
Output(-)  
Output(-)  
1
1
Input(L)  
7
1
7
1
CN1  
CN1  
CN2  
CN2  
Output(+)  
Output(+)  
6
6
2
1
2 1  
CN4  
Connector for Remote  
4
ON/OFF (optional)  
Voltage adjust  
[0.16]  
18  
[0.71]  
(LFA150F-3R3-Y,LFA150F-5-Y or Optional)  
Mounting Hole  
188  
[7.4]  
5
150 0.5  
[5.91]  
160  
[0.2]  
6
f4.5  
176 0.5  
[0.24]  
[6.93]  
[6.3]  
2-M4  
Mounting Hole  
PCB t=1.6  
1  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
Connector type  
CN4 Option (Mfr:J.S.T)  
<PIN CONNECTION>  
CN1  
CN2  
CN3  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Pin No. Output  
PIN No.  
Contents  
RC(+)  
Chain  
Loose  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
1
2
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-6 1-1123722-6  
CN3 1-1123723-7 1-1123722-7  
RC(-)  
AC(N)  
1 to 7  
-V  
1 to 6  
+V  
Barrier strip type  
Model B2B-XH-A  
FG  
Keep drawing current per pin below 5A for CN2,CN3.  
Mating Connector (Terminal)  
XHP-2  
(Mfr:Tyco Electronics)  
Tolerance : 1 [ 0.04]  
Weight : 390g max (with chassis & cover : 650g max)  
PCB material : CEM3  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:VH(J.S.T) connector type.  
BXH-001T-P0.6  
or SXH-001T-P0.6  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max  
LFA-15  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
240  
F
-O -O  
5 6  
LFA240F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Recommended EMI/EMC Filter  
NAC-06-472  
R
LFA  
*1  
6Optional  
C: with Coating  
G: Low leakage current  
H: with the function to be acceptable  
to output peak current (only 24V)  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
J1: VH(J.S.T.)connector type  
R: with Remote ON/OFF  
R2: with Remote ON/OFF  
S : with Chassis  
SN: with Chassis & cover  
T : Vertical terminal block  
Y: with Potentiometer  
Please refer to Instruction  
manual 5.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,  
so handle the unit with care.  
MODEL  
LFA240F-24  
240  
LFA240F-24-H  
240 (300)  
LFA240F-36  
241.2  
LFA240F-48  
240  
*5  
*5  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
24V 10A  
24V 10 (12.5)A  
36V 6.7A  
48V 5A  
SPECIFICATIONS  
MODEL  
LFA240F-24  
LFA240F-24-H  
LFA240F-36  
LFA240F-48  
*4  
VOLTAGE[V]  
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)  
ACIN 100V 3.3typ (Io=100%)  
ACIN 200V 1.7typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
ACIN 100V 84.5typ  
84.5typ  
87.5typ  
84.5typ  
87.5typ  
84.5typ  
87.5typ  
EFFICIENCY[%]  
INPUT  
ACIN 200V 87.5typ  
ACIN 100V 0.99typ  
POWER FACTOR (Io=100%)  
INRUSH CURRENT[A]  
ACIN 200V 0.95typ  
ACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)  
ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
24  
24  
36  
48  
*5  
*7  
*7  
*2  
10  
10 (Peak12.5)  
96max  
6.7  
5
CURRENT[A]  
96max  
150max  
120max  
160max  
150max  
180max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
150max  
240max  
320max  
300max  
360max  
240max  
290max  
96max  
0 to +40C  
RIPPLE[mVp-p]  
*2  
*2  
-10 - 0C  
0 to +40C  
RIPPLE NOISE[mVp-p]  
*2  
OUTPUT  
-10 - 0C  
0 to +40C 240max  
TEMPERATURE REGULATION[mV]  
-10 to +40  
C
290max  
3
96max  
*
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
Fixed (“Y”option is available for adjusting output voltage)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
OUTPUT VOLTAGE SETTING[V]  
23.00 to 25.00  
23.00 to 25.00  
34.50 to 37.50  
46.00 to 50.00  
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically  
OVERVOLTAGE PROTECTION 27.60 to 33.60 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
Option (Refer to Instruction Manual)  
.
*6  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max  
INPUT-OUTPUT RC  
INPUT-FG  
ISOLATION  
.
*6  
*6  
*4  
OUTPUT RC-FG  
OUTPUT-RC  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*8  
Complies with IEC61000-3-2 (Class A)  
84X46.5X180mm [3.31X1.83X7.09 inches] (WXHXD) / 550g max (with chassis & cover : 880g max)  
OTHERS  
*4  
Convection (Refer to Instruction Manual 3.1 and 3.2)  
*1 Specification is changeed at option, refer to Instruction Manual.  
at the rated input/output.  
*8 Please contact us about another class.  
*2 This is the value that measured on measuring board with *4 Derating is required.  
*
To meet the specifications. Do not operate over-loaded  
condition.  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
*5 ( ) means peak current. There is a possibility that an internal  
device is damaged when the specification is exceeded. Please *  
Parallel operation is not possible.  
contact us about the detail.  
*
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of  
pulse load.  
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when remote control (optional) is added.  
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.  
LFA-16  
LFA240F  
Block diagram  
FUSE  
250V10A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
LFA  
FG  
Photocoupler  
OPTION  
CURRENT  
SENSING  
RC  
E
EXTERNAL  
SOURCE  
Photocoupler  
Photocoupler  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CONTROL  
INVERTER  
CONTROL  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
RECTIFIER  
AND  
FILTER  
TRANSFORMER  
DC OUT  
External view  
External size of option is different from standard model.  
Standard type  
Chassis and cover type  
Connector for Remote  
ON/OFF (Optional)  
200 0.5  
[7.87]  
6
[0.24]  
2-f4.5  
4-M4  
Mounting Hole  
16.5  
[0.65]  
4-f3.5  
Mounting Hole  
FG  
Voltage adjust(Optional)  
Name plate  
1
2
1
2
CN4  
1
1
FG  
FG  
5
3
5
3
CN3  
Output(-)  
CN3  
Input(N)  
Input(L)  
Input(N)  
Input(L)  
Output(-)  
1
1
CN1  
CN1  
7
1
7
1
CN2  
CN2  
Output(+)  
Output(+)  
6
6
4
[0.16]  
89 0.5  
[3.5]  
Point A Point B  
Mounting Hole  
212  
170 0.5  
[6.69]  
5
[0.2]  
[8.35]  
6
f4.5  
200 0.5  
[7.87]  
180  
[7.09]  
[0.24]  
2-M4  
Mounting Hole  
1  
PCB t=1.6  
1 Surface mount device  
5 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
Connector type  
<PIN CONNECTION>  
CN1  
CN2  
CN3  
CN4 Option (Mfr:J.S.T)  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Pin No. Output  
PIN No.  
Contents  
RC(+)  
Chain  
Loose  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
1
2
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-6 1-1123722-6  
CN3 1-1123723-7 1-1123722-7  
RC(-)  
AC(N)  
1 to 7  
-V  
1 to 6  
+V  
Barrier strip type  
Model B2B-XH-A  
Mating Connector (Terminal)  
XHP-2  
FG  
Keep drawing current per pin below 5A for CN2,CN3.  
(Mfr:Tyco Electronics)  
Tolerance : 1 [ 0.04]  
Weight : 550g max (with chassis & cover : 880g max)  
PCB material : CEM3  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:VH(J.S.T) connector type.  
BXH-001T-P0.6  
or SXH-001T-P0.6  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max  
LFA-17  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
300  
F
-O -O  
5 6  
LFA300F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Recommended EMI/EMC Filter  
NAC-06-472  
R
*1  
6Optional  
LFA  
C: with Coating  
G: Low leakage current  
H: with the function to be acceptable  
to output peak current  
(Only 24V, 30V, 36V and 48V)  
J : EP (Tyco Electronics) connector type  
(Except 3.3V and 5V)  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
J1  
:
VH (J.S.T.) connector type  
(Except 3.3V and 5V)  
R: with Remote ON/OFF  
R2: with Remote ON/OFF  
S : with Chassis  
SNF  
:
with Chassis & cover & fan  
(Only 5V, 12V and 24V)  
Holizontal terminal block  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,  
so handle the unit with care.  
T1  
:
Please refer to Instruction manual 5.  
MODEL  
LFA300F-3R3-TY LFA300F-5-TY LFA300F-12-TY LFA300F-15-TY LFA300F-24-TY LFA300F-24-HTY LFA300F-30-TY LFA300F-36-TY LFA300F-48-TY  
*5  
198  
300  
324  
330  
336  
336 (456) 330  
338.4  
336  
MAX OUTPUT WATTAGE[W]  
Convection  
Forced air  
3.3V 40A  
3.3V 60A  
5V 40A  
5V 60A  
12V 17A  
12V 27A  
15V 14A  
15V 22A  
24V 12.5A 24V 12.5 (19)A 30V 10A  
36V 8.4A  
36V 9.4A  
48V 6.3A  
48V 7A  
*5  
DC OUTPUT  
24V 14A  
24V 14 (19)A 30V 11A  
SPECIFICATIONS  
MODEL  
LFA300F-3R3-TY LFA300F-5-TY  
LFA300F-12-TY  
LFA300F-15-TY  
LFA300F-24-TY  
LFA300F-24-HTY LFA300F-30-TY  
LFA300F-36-TY  
LFA300F-48-TY  
*4  
VOLTAGE[V]  
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)  
ACIN 100V 2.7typ (Io=100%) 4.1typ (Io=100%)  
ACIN 200V 1.4typ (Io=100%) 2.0typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
ACIN 100V 75.0typ  
ACIN 200V 77.0typ  
ACIN 100V 0.98typ  
ACIN 200V 0.92typ  
79.0typ  
82.5typ  
0.99typ  
0.95typ  
80.0typ  
83.0typ  
81.5typ  
84.5typ  
85.0typ  
88.0typ  
85.0typ  
88.0typ  
85.5typ  
88.0typ  
85.5typ  
88.0typ  
85.5typ  
88.0typ  
EFFICIENCY[%]  
INPUT  
POWER FACTOR (Io=100%)  
INRUSH CURRENT[A]  
ACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)  
ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
3.3  
5
12  
15  
24  
24  
30  
36  
48  
Convection 40  
Forced air 60  
*7  
40  
60  
17  
27  
14  
22  
12.5  
14  
12.5 (Peak19) 10  
14 (Peak19) 11  
8.4  
9.4  
6.3  
7
*5  
CURRENT[A]  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
96max  
144max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
*7  
*2  
*2  
*2  
150max  
240max  
320max  
300max  
360max  
240max  
290max  
96max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
0 to +40C  
RIPPLE[mVp-p]  
-10 - 0C  
0 to +40C  
OUTPUT  
RIPPLE NOISE[mVp-p]  
TEMPERATURE REGULATION[mV]  
*2  
-10 - 0C  
0 to +40C 50max  
-10 to +40  
C
60max  
3
20max  
*
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
2.85 to 3.63 4.50 to 5.50  
3.30 to 3.40 5.00 to 5.15  
10.80 to 13.20 13.50 to 16.50 21.60 to 27.50 21.60 to 27.50 27.00 to 33.00 32.40 to 39.60 39.60 to 52.80  
12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 24.00 to 24.96 30.00 to 31.20 36.00 to 37.44 48.00 to 49.92  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically  
OVERVOLTAGE PROTECTION  
4.00 to 5.25  
5.75 to 7.00  
13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 27.60 to 33.60 34.50 to 42.00 41.40 to 50.40 55.20 to 67.20  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
Not provided  
Option (Refer to Instruction Manual)  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
.
*6  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max  
INPUT-OUTPUT RC  
INPUT-FG  
ISOLATION  
.
*6  
*6  
*4  
OUTPUT RC-FG  
OUTPUT-RC  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*8  
Complies with IEC61000-3-2 (Class A)  
95X52.5X222mm [3.74X2.07X8.74 inches] (WXHXD) (without terminal block) / 810g max (with chassis & cover : 1,270g max)  
OTHERS  
*4  
Convection / Forced air (Refer to Instruction Manual 3.1 and 3.2)  
*1 Specification is changeed at option, refer to Instruction Manual.  
at the rated input/output.  
*8 Please contact us about another class.  
*2 This is the value that measured on measuring board with *4 Derating is required.  
*
To meet the specifications. Do not operate over-loaded  
condition.  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
*5 ( ) means peak current. There is a possibility that an internal  
device is damaged when the specification is exceeded. Please *  
Parallel operation is not possible.  
contact us about the detail.  
*
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of  
pulse load.  
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when remote control (optional) is added.  
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.  
LFA-18  
LFA300F  
Block diagram  
FUSE  
250V10A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
LFA  
FG  
Photocoupler  
OPTION  
CURRENT  
SENSING  
RC  
EXTERNAL  
SOURCE  
E
Photocoupler  
Photocoupler  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CONTROL  
INVERTER  
CONTROL  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
RECTIFIER  
AND  
FILTER  
TRANSFORMER  
DC OUT  
External view  
External size of option is different from standard model.  
Standard type  
Connector for  
Point B  
4-f3.5  
Mounting Hole  
Name plate  
FG  
Point C  
Point D  
Remote ON/OFF  
(Optional)  
M4  
1
2
CN4  
FG  
TB2  
Input(N)  
Output(-)  
Input(L)  
TB1  
Output(+)  
M4  
4
[0.16]  
5
[0.2]  
109 0.5  
[4.29]  
Voltage adjust  
Mounting Hole  
Point A  
46.5  
[1.83]  
212 0.5  
[8.35]  
Connector type  
CN4 Option (Mfr:J.S.T)  
222  
[8.74]  
PIN No.  
Contents  
RC(+)  
1
2
RC(-)  
Barrier strip type  
Model B2B-XH-A  
Mating Connector (Terminal)  
XHP-2  
PCB t=1.6  
1  
1 Surface mount device  
BXH-001T-P0.6  
or SXH-001T-P0.6  
5 Mounting holes are existing.  
Tolerance : 1 [ 0.04]  
Weight : 810g max (with chassis & cover : 1,270g max)  
PCB material : CEM3  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B, Point C, Point D are thermometry points.  
Please refer to Instruction Manual 3.  
Dimensions in mm, [ ]=inches  
Screw tightening torque : M4 1.6N-m (16.9kgf-cm) max  
Keep drawing current per pin below 20A for TB2.  
LFA-19  

相关型号:

LFA100F-12-GY

AC/DC CONVERTER 12V
COSEL

LFA100F-12-J1

AC/DC CONVERTER 12V
COSEL

LFA100F-12-J1R

AC/DC CONVERTER 12V
COSEL

LFA100F-12-J1R2

AC/DC CONVERTER 12V
COSEL

LFA100F-12-J1R2Y

AC/DC CONVERTER 12V
COSEL

LFA100F-12-J1RY

AC/DC CONVERTER 12V
COSEL

LFA100F-12-J1Y

AC/DC CONVERTER 12V
COSEL

LFA100F-12-R

AC/DC CONVERTER 12V
COSEL

LFA100F-12-R2

AC/DC CONVERTER 12V
COSEL

LFA100F-12-R2Y

AC/DC CONVERTER 12V
COSEL

LFA100F-12-RY

AC/DC CONVERTER 12V
COSEL

LFA100F-12-S

AC/DC CONVERTER 12V