LFA100F-24-R2Y [COSEL]

AC/DC CONVERTER 24V;
LFA100F-24-R2Y
型号: LFA100F-24-R2Y
厂家: COSEL CO., LTD.    COSEL CO., LTD.
描述:

AC/DC CONVERTER 24V

文件: 总23页 (文件大小:3765K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
AC-DC Power Supplies Open Frame/ Enclosed Type  
Power  
Cost  
Effective  
Rugged  
PCB type  
Safety  
Approvals  
EMI  
OCP  
OVP  
World wide  
Inrush  
current  
limiting  
Factor  
Correction  
LFA-series  
Feature  
Small and compact PCB construction  
CE marking  
Low Voltage Directive  
Built-in inrush current, overcurrent and overvoltage protection  
circuits  
RoHS Directive  
Harmonic attenuator (Complies with IEC61000-3-2)  
Universal input (AC85-264V)  
Power factor correction (LFA50F-300F)  
Built-in reducing standby power circuit (LFA10F, 15F)  
EMS Compliance : EN61204-3, EN61000-6-2  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
EN61000-4-11  
Safety agency approvals  
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN62368-1,  
EN50178, EN60065  
Complies with DEN-AN  
EMI  
Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B,  
VCCI-B  
5-year warranty (refer to Instruction Manual)  
June 26, 2020  
LFA-1  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
10  
F
-O -O  
5 6  
LFA10F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
6Optional  
Example recommended EMI/EMC filter  
NAC-04-472  
R
C: with Coating  
G: Low leakage current  
J1: VH(J.S.T.)connector type  
S : with Chassis  
SN: with Chassis & cover  
Y: with Potentiometer  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
Specification is changed at  
option, refer to Instruction  
Manual.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
MODEL  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
LFA10F-3R3-Y  
6.6  
3.3V 2A  
LFA10F-5  
10  
5V 2A  
LFA10F-12  
10.8  
12V 0.9A  
LFA10F-15  
10.5  
15V 0.7A  
LFA10F-24  
12  
24V 0.5A  
SPECIFICATIONS  
MODEL  
LFA10F-3R3-Y  
LFA10F-5  
LFA10F-12  
LFA10F-15  
LFA10F-24  
*3  
AC85 - 264 1f(Refer to “Derating”, Instruction Manual 1 and 3)  
VOLTAGE[V]  
ACIN 100V 0.18typ (Io=100%)  
0.26typ (Io=100%)  
0.16typ (Io=100%)  
CURRENT[A]  
ACIN 200V 0.11typ (Io=100%)  
50 / 60 (47 - 440)  
FREQUENCY[Hz]  
INPUT  
ACIN 100V 68.0typ  
74.0typ  
76.0typ  
76.5typ  
79.0typ  
77.5typ  
80.0typ  
79.5typ  
83.0typ  
EFFICIENCY[%]  
ACIN 200V 68.5typ  
ACIN 100V 15typ (Io=100%)  
ACIN 200V 30typ (Io=100%)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)  
3.3  
5
12  
15  
24  
CURRENT[A]  
2.0  
2.0  
0.9  
0.7  
0.5  
*
*
5
5
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
40max  
20max  
40max  
80max  
140max  
160max  
120max  
160max  
240max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
240max  
150max  
180max  
300max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
240max  
150max  
180max  
300max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
280max  
150max  
180max  
320max  
240max  
290max  
96max  
0 to +50C 80max  
-10 - 0C 140max  
Io=0 - 35% 190max  
0 to +50C 120max  
-10 - 0C 160max  
Io=0 - 35% 240max  
0 to +50C 50max  
-10 to +50C 60max  
RIPPLE[mVp-p]  
*1  
RIPPLE NOISE[mVp-p]  
OUTPUT  
*1  
TEMPERATURE REGULATION[mV]  
*
2
20max  
DRIFT[mV]  
START-UP TIME[ms]  
200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.  
HOLD-UP TIME[ms]  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION  
OVERVOLTAGE PROTECTION  
2.85 to 3.63  
3.30 to 3.40  
Fixed (“Y”option is available for adjusting output voltage between 10%)  
4.90 to 5.30  
11.50 to 12.50  
14.40 to 15.60  
23.00 to 25.00  
27.60 to 33.60  
Works over 105% of rating and recovers automatically  
4.00 to 5.25  
Not provided  
Not provided  
Not provided  
5.75 to 7.00  
13.80 to 16.80  
17.25 to 21.00  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
INPUT-FG  
OUTPUT-FG  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
ISOLATION  
*3  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE  
VIBRATION  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to “Derating”, Instruction Manual 3), 3,000m (10,000 feet) max  
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max  
ENVIRONMENT  
2
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN62368-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*6  
*4  
(Not built-in to active filter)  
Complies with IEC61000-3-2 (Class A)  
50X22X73.5mm [1.97X0.87X2.89 inches] (WXHXD) / 55g max (with chassis & cover : 150g max)  
OTHERS  
*3  
Convection (Refer to “Derating”, Instruction Manual 3)  
*1  
This is the value that measured on measuring board with  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
factor Io=0-35% is different.  
Please contact us for details.  
Please refer to the Instruction Manual 1.7.  
Drift is the change in DC output for an eight hour period after  
a half-hour warm-up at 25C, with the input voltage held  
constant at the rated input/output.  
*5  
*6  
*
Please contact us about dynamic load and input response.  
Please contact us about another class.  
*2  
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
A circuit reducing standby power is built in this unit.  
Therefore, the internal switch element is intermittent  
operated, and the Ripple/Ripple Noise specification in load  
*
*3  
*4  
Derating is required.  
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse  
load.  
When two or more units are operating it may not comply with  
*
the IEC61000J-3u-2.ne 26, 2020  
LFA-2  
LFA10F  
Block diagram  
FUSE  
AC250V  
2A  
INRUSH  
CURRENT  
LIMIT  
RECTIFIER  
AND  
FILTER  
AC IN  
85 264V  
NOISE  
FILTER  
FG  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
CURRENT  
SENSING  
Photocoupler  
Photocoupler  
CONTROL  
OVER VOLTAGE  
PROTECTION  
External view  
Standard type  
Chassis and cover type  
FG  
4.6  
[0.18]  
0.5  
f3.5  
83.5  
4-M3  
Mounting Hole  
5
[0.2]  
[3.29]  
CN2  
CN1  
5
FG  
1
2
Output(-)  
Output(+)  
3
Input(N)  
Input(L)  
Voltage adjust  
(LFA10F-3R3-Y or optional)  
1
Output(-)  
CN1  
CN2  
5
Output(+)  
FG  
Input(N)  
Input(L)  
1
2
2-  
f3.5  
3
1
Mounting Hole  
0.5  
63.5  
[2.5]  
5
[0.2]  
Name plate  
73.5  
[2.89]  
Point A  
Point B  
93.5  
[3.68]  
0.5  
f3.5  
5
[0.2]  
83.5  
[3.29]  
1  
PCB t=1.6  
1 Surface mount device  
2-M3  
Mounting Hole  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN1  
CN2  
Tolerance : 1 [ 0.04]  
Weight : 55g max (with chassis & cover : 150g max)  
PCB material / thickness : CEM3 / 1.6mm  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-2 1-1123722-2  
1
-V  
AC(N)  
FG  
2
+V  
Mounting torque (Mounting hole of chassis) : 0.6N-m (6.3kgf-cm) max  
(Mfr:Tyco Electronics)  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 6.  
June 26, 2020  
LFA-3  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
15  
F
-O -O  
5 6  
LFA15F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
6Optional  
Example recommended EMI/EMC filter  
NAC-04-472  
R
C: with Coating  
G: Low leakage current  
J1: VH(J.S.T.)connector type  
S : with Chassis  
SN: with Chassis & cover  
Y: with Potentiometer  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
Specification is changed at  
option, refer to Instruction  
Manual.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
MODEL  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
LFA15F-3R3-Y  
9.9  
3.3V 3A  
LFA15F-5  
15  
5V 3A  
LFA15F-12  
15.6  
12V 1.3A  
LFA15F-15  
15  
15V 1A  
LFA15F-24  
16.8  
24V 0.7A  
SPECIFICATIONS  
MODEL  
LFA15F-3R3-Y  
LFA15F-5  
LFA15F-12  
LFA15F-15  
LFA15F-24  
*3  
AC85 - 264 1f(Refer to “Derating”, Instruction Manual 1 and 3)  
VOLTAGE[V]  
ACIN 100V 0.24typ (Io=100%)  
0.35typ (Io=100%)  
0.20typ (Io=100%)  
CURRENT[A]  
ACIN 200V 0.15typ (Io=100%)  
50 / 60 (47 - 440)  
FREQUENCY[Hz]  
INPUT  
ACIN 100V 68.0typ  
73.0typ  
76.0typ  
76.0typ  
78.5typ  
77.0typ  
80.0typ  
78.0typ  
81.5typ  
EFFICIENCY[%]  
ACIN 200V 69.0typ  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)  
3.3  
5
12  
15  
24  
CURRENT[A]  
3.0  
3.0  
1.3  
1.0  
0.7  
*
*
5
5
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
40max  
20max  
40max  
80max  
140max  
160max  
120max  
160max  
240max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
240max  
150max  
180max  
300max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
240max  
150max  
180max  
300max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
280max  
150max  
180max  
320max  
240max  
290max  
96max  
0 to +50C 80max  
-10 - 0C 140max  
Io=0 - 35% 190max  
0 to +50C 120max  
-10 - 0C 160max  
Io=0 - 35% 240max  
0 to +50C 50max  
-10 to +50C 60max  
RIPPLE[mVp-p]  
*1  
RIPPLE NOISE[mVp-p]  
OUTPUT  
*1  
TEMPERATURE REGULATION[mV]  
*
2
20max  
DRIFT[mV]  
START-UP TIME[ms]  
200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.  
HOLD-UP TIME[ms]  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION  
OVERVOLTAGE PROTECTION  
2.85 to 3.63  
3.30 to 3.40  
Fixed (“Y”option is available for adjusting output voltage between 10%)  
4.90 to 5.30  
11.50 to 12.50  
14.40 to 15.60  
23.00 to 25.00  
27.60 to 33.60  
Works over 105% of rating and recovers automatically  
4.00 to 5.25  
Not provided  
Not provided  
Not provided  
5.75 to 7.00  
13.80 to 16.80  
17.25 to 21.00  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
INPUT-FG  
OUTPUT-FG  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
ISOLATION  
*3  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE  
VIBRATION  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to “Derating”, Instruction Manual 3), 3,000m (10,000 feet) max  
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max  
ENVIRONMENT  
2
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN62368-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*6  
*4  
(Not built-in to active filter)  
Complies with IEC61000-3-2 (Class A)  
50X22X87.5mm [1.97X0.87X3.44 inches] (WXHXD) / 80g max (with chassis & cover : 190g max)  
OTHERS  
*3  
Convection (Refer to “Derating”, Instruction Manual 3)  
*1  
This is the value that measured on measuring board with  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
factor Io=0-35% is different.  
Please contact us for details.  
Please refer to the Instruction Manual 1.7.  
Drift is the change in DC output for an eight hour period after  
a half-hour warm-up at 25C, with the input voltage held  
constant at the rated input/output.  
*5  
*6  
*
Please contact us about dynamic load and input response.  
Please contact us about another class.  
*2  
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
A circuit reducing standby power is built in this unit.  
Therefore, the internal switch element is intermittent  
operated, and the Ripple/Ripple Noise specification in load  
*
*3  
*4  
Derating is required.  
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse  
load.  
When two or more units are operating it may not comply with  
*
the IEC61000J-3u-2.ne 26, 2020  
LFA-4  
LFA15F  
Block diagram  
FUSE  
AC250V  
2.5A  
INRUSH  
CURRENT  
LIMIT  
RECTIFIER  
AND  
FILTER  
AC IN  
85 264V  
NOISE  
FILTER  
FG  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
CURRENT  
SENSING  
Photocoupler  
Photocoupler  
CONTROL  
OVER VOLTAGE  
PROTECTION  
External view  
Standard type  
Chassis and cover type  
FG  
4.4  
0.5  
97.5  
5
[0.2]  
f3.5  
4-M3  
Mounting Hole  
[0.17]  
[3.84]  
CN2  
Output(-)  
Output(+)  
CN1  
5
1
2
FG  
3
Input(N)  
Output(-)  
CN1  
5
CN2  
Voltage adjust  
(LFA15F-3R3-Y or optional)  
Output(+)  
1
1
2
Input(L)  
FG  
Input(N)  
Input(L)  
3
1
2-  
f3.5  
0.5  
Mounting Hole  
77.5  
[3.05]  
87.5  
[3.44]  
5
[0.2]  
Name plate  
107.5  
[4.23]  
Point A  
Point B  
f3.5  
0.5  
97.5  
5
[0.2]  
[3.84]  
PCB t=1.6  
1  
2-M3  
Mounting Hole  
1 Surface mount device  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN1  
CN2  
Tolerance : 1 [ 0.04]  
Weight : 80g max (with chassis & cover : 190g max)  
PCB material / thickness : CEM3 / 1.6mm  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-2 1-1123722-2  
1
-V  
AC(N)  
FG  
2
+V  
Mounting torque (Mounting hole of chassis) : 0.6N  
-
m (6.3kgf-  
cm) max  
(Mfr:Tyco Electronics)  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 6.  
June 26, 2020  
LFA-5  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
30  
F
-O -O  
5 6  
LFA30F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
6Optional  
Example recommended EMI/EMC filter  
NAC-04-472  
R
C: with Coating  
G: Low leakage current  
J1: VH(J.S.T.)connector type  
S : with Chassis  
SN: with Chassis & cover  
Y: with Potentiometer  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
Specification is changed at  
option, refer to Instruction  
Manual.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
MODEL  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
LFA30F-3R3-Y  
19.8  
3.3V 6A  
LFA30F-5  
30.0  
5V 6A  
LFA30F-12  
30.0  
12V 2.5A  
LFA30F-15  
30.0  
15V 2A  
LFA30F-24  
31.2  
24V 1.3A  
SPECIFICATIONS  
MODEL  
LFA30F-3R3-Y  
LFA30F-5  
LFA30F-12  
LFA30F-15  
LFA30F-24  
*3  
VOLTAGE[V]  
AC85 - 264 1f(Refer to “Derating”, Instruction Manual 1 and 3)  
ACIN 100V 0.50typ (Io=100%)  
0.65typ (Io=100%)  
0.35typ (Io=100%)  
CURRENT[A]  
ACIN 200V 0.30typ (Io=100%)  
50 / 60 (47 - 440)  
ACIN 100V 73typ  
FREQUENCY[Hz]  
INPUT  
76typ  
79typ  
79typ  
81typ  
81typ  
83typ  
82typ  
84typ  
EFFICIENCY[%]  
ACIN 200V 75typ  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.30 / 0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)  
3.3  
5
12  
15  
24  
CURRENT[A]  
6.0  
6.0  
2.5  
2.0  
1.3  
*5  
*5  
*1  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
0 to +50C  
RIPPLE[mVp-p]  
*1  
*1  
-10 - 0C  
0 to +50C  
RIPPLE NOISE[mVp-p]  
*1  
OUTPUT  
-10 - 0C  
0 to +50C 50max  
TEMPERATURE REGULATION[mV]  
-10 to +50  
C
60max  
20max  
*
2
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
150typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
2.85 to 3.63  
3.30 to 3.40  
Fixed (“Y”option is available for adjusting output voltage between 10%)  
OUTPUT VOLTAGE SETTING[V]  
4.90 to 5.30  
11.50 to 12.50  
14.40 to 15.60  
23.00 to 25.00  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80  
17.25 to 21.00  
27.60 to 33.60  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
Not provided  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
ISOLATION INPUT-FG  
OUTPUT-FG  
*3  
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing) (Refer to “Derating”, Instruction Manual 3), 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN62368-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*6  
*4  
(Not built-in to active filter)  
Complies with IEC61000-3-2 (Class A)  
50X26.5X105mm [1.97X1.04X4.13 inches] (WXHXD) / 130g max (with chassis & cover : 260g max)  
OTHERS  
*3  
Convection (Refer to “Derating”, Instruction Manual 3)  
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm  
from output terminal.  
*4 When two or more units are operating it may not comply with the IEC61000-3-2.  
Please contact us for details.  
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:  
RM103).  
*5 Please contact us about dynamic load and input response.  
*6 Please contact us about another class.  
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at  
25C, with the input voltage held constant at the rated input/output.  
*3 Derating is required.  
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse load.  
June 26, 2020  
LFA-6  
LFA30F  
Block diagram  
FUSE  
AC250V  
3.15A  
INRUSH  
CURRENT  
LIMIT  
RECTIFIER  
AND  
FILTER  
AC IN  
85 264V  
NOISE  
FILTER  
FG  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
CURRENT  
SENSING  
Photocoupler  
Photocoupler  
CONTROL  
OVER VOLTAGE  
PROTECTION  
External view  
Standard type  
Chassis and cover type  
3-  
f3.5  
4.5  
Name plate  
FG  
[0.18]  
Mounting Hole  
0.5  
5
[0.2]  
f3.5  
4-M3  
Mounting Hole  
115  
[4.53]  
CN2  
5
FG  
1
2
3
4
Output(-)  
Output(+)  
3
Input(N)  
Input(L)  
CN2  
1
5
3
FG  
1
2
3
4
Output(-)  
CN1  
Input(N)  
Input(L)  
Output(+)  
1
CN1  
4
Voltage adjust  
(LFA30F-3R3-Y or optional)  
[0.16]  
0.5  
5
95  
[3.74]  
[0.2]  
105  
Mounting Hole  
[4.13]  
Point A  
Point B  
125  
[4.92]  
0.5  
f3.5  
115  
5
[4.53]  
[0.2]  
PCB t=1.6  
1  
2-M3  
Mounting Hole  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN1  
CN2  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Tolerance : 1 [ 0.04]  
Weight: 130g max (with chassis & cover : 260g max)  
PCB material / thickness : CEM3 / 1.6mm  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-4 1-1123722-4  
1, 2  
-V  
AC(N)  
FG  
3, 4  
+V  
(Mfr:Tyco Electronics)  
Mounting torque (Mounting hole of chassis) : 0.6N  
-
m (6.3kgf-  
cm) max  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 6.  
Keep drawing current per pin below 5A for CN2.  
June 26, 2020  
LFA-7  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
50  
F
-O -O  
5 6  
LFA50F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
6Optional  
Example recommended EMI/EMC filter  
NAC-04-472  
R
C: with Coating  
G: Low leakage current  
J1: VH(J.S.T.)connector type  
S : with Chassis  
SN: with Chassis & cover  
Y: with Potentiometer  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
Specification is changed at  
option, refer to Instruction  
Manual.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
MODEL  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
LFA50F-3R3-Y LFA50F-5  
LFA50F-12  
51.6  
12V 4.3A  
LFA50F-15  
52.5  
15V 3.5A  
LFA50F-24  
50.4  
24V 2.1A  
LFA50F-36  
50.4  
36V 1.4A  
LFA50F-48  
52.8  
48V 1.1A  
33  
50  
3.3V 10A  
5V 10A  
SPECIFICATIONS  
MODEL  
LFA50F-3R3-Y LFA50F-5  
LFA50F-12  
LFA50F-15  
LFA50F-24  
LFA50F-36  
LFA50F-48  
*3  
VOLTAGE[V]  
AC85 - 264 1f(Refer to “Derating”, Instruction Manual 1 and 3)  
ACIN 100V 0.47typ (Io=100%) 0.67typ (Io=100%)  
ACIN 200V 0.27typ (Io=100%) 0.36typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
ACIN 100V 73.5typ  
ACIN 200V 74.0typ  
ACIN 100V 0.96typ  
ACIN 200V 0.83typ  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
77.5typ  
79.0typ  
0.97typ  
0.90typ  
80.0typ  
81.5typ  
80.5typ  
81.5typ  
81.5typ  
83.0typ  
82.0typ  
83.5typ  
81.0typ  
82.5typ  
EFFICIENCY[%]  
INPUT  
POWER FACTOR (Io=100%)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)  
3.3  
5
12  
15  
24  
36  
48  
CURRENT[A]  
10.0  
10.0  
4.3  
3.5  
2.1  
1.4  
1.1  
*4  
*4  
*1  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
0 to +50C  
RIPPLE[mVp-p]  
*1  
*1  
-10 - 0C  
0 to +50C  
RIPPLE NOISE[mVp-p]  
*1  
OUTPUT  
-10 - 0C  
0 to +50C 50max  
TEMPERATURE REGULATION[mV]  
-10 to +50  
C
60max  
20max  
*
2
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
2.85 to 3.63  
3.30 to 3.40  
Fixed (“Y”option is available for adjusting output voltage between 10%)  
OUTPUT VOLTAGE SETTING[V]  
4.90 to 5.30  
11.50 to 12.50  
14.40 to 15.60  
23.00 to 25.00  
34.50 to 37.50  
46.00 to 50.00  
55.20 to 67.20  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00  
27.60 to 33.60  
41.40 to 50.40  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
Not provided  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
ISOLATION INPUT-FG  
OUTPUT-FG  
*3  
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing) (Refer to “Derating”, Instruction Manual 3), 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN62368-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*5  
Complies with IEC61000-3-2 (Class A)  
50X26.5X132mm [1.97X1.04X5.20 inches] (WXHXD) / 165g max (with chassis & cover : 325g max)  
OTHERS  
*3  
Convection (Refer to “Derating”, Instruction Manual 3)  
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm  
from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:  
RM103).  
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at  
25C, with the input voltage held constant at the rated input/output.  
*3 Derating is required.  
*4 Please contact us about dynamic load and input response.  
*5 Please contact us about another class.  
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse load.  
June 26, 2020  
LFA-8  
LFA50F  
Block diagram  
FUSE  
250V2.5A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
AC IN 85 264V  
FG  
RECTIFIER  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CURRENT  
SENSING  
Photocoupler  
Photocoupler  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
CONTROL  
External view  
Standard type  
Voltage adjust  
Chassis and cover type  
4-M3  
Mounting Hole  
2-f3.5  
0.5  
3-  
f3.5  
150  
6
4.9  
Name plate  
FG  
(LFA50F-3R3-Y or optional)  
[5.91]  
[0.24]  
[0.19]  
Mounting Hole  
5
FG  
5
3
FG  
Input(N)  
Input(L)  
3
Input(N)  
Input(L)  
1
2
3
4
Output(-)  
Output(+)  
CN2  
1
1
2
3
4
1
CN1  
Output(-)  
CN1  
Output(+)  
CN2  
4
Point A  
Point B  
[0.16]  
Mounting Hole  
0.5  
5
122  
[4.8]  
132  
[0.2]  
162  
[5.2]  
[6.38]  
0.5  
f3.5  
150  
6
[5.91]  
[0.24]  
PCB t=1.6  
2-M3  
Mounting Hole  
1  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN1  
Pin No.  
CN2  
Pin No. Output  
Tolerance : 1 [ 0.04]  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Input  
Weight : 165g max (with chassis & cover : 325g max)  
PCB material / thickness : CEM3 / 1.6mm  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
AC(L)  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-4 1-1123722-4  
1, 2  
-V  
AC(N)  
FG  
3, 4  
+V  
Mounting torque (Mounting hole of chassis) : 0.6N  
-m (6.3kgf  
-cm) max  
(Mfr:Tyco Electronics)  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 6.  
Keep drawing current per pin below 5A for CN2.  
June 26, 2020  
LFA-9  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
75  
F
-O -O  
5 6  
LFA75F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
6Optional  
Example recommended EMI/EMC filter  
NAC-04-472  
R
C: with Coating  
G: Low leakage current  
J1: VH(J.S.T.)connector type  
S : with Chassis  
SN: with Chassis & cover  
Y: with Potentiometer  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
Specification is changed at  
option, refer to Instruction  
Manual.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
MODEL  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
LFA75F-3R3-Y LFA75F-5  
LFA75F-12  
75.6  
12V 6.3A  
LFA75F-15  
75  
15V 5A  
LFA75F-24  
76.8  
24V 3.2A  
LFA75F-36  
75.6  
36V 2.1A  
LFA75F-48  
76.8  
48V 1.6A  
49.5  
75  
3.3V 15A  
5V 15A  
SPECIFICATIONS  
MODEL  
LFA75F-3R3-Y LFA75F-5  
LFA75F-12  
LFA75F-15  
LFA75F-24  
LFA75F-36  
LFA75F-48  
*3  
VOLTAGE[V]  
AC85 - 264 1f(Refer to “Derating”, Instruction Manual 1 and 3)  
ACIN 100V 0.70typ (Io=100%) 1.00typ (Io=100%)  
ACIN 200V 0.40typ (Io=100%) 0.50typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
ACIN 100V 73.5typ  
ACIN 200V 75.0typ  
ACIN 100V 0.96typ  
ACIN 200V 0.83typ  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
78.0typ  
80.0typ  
0.97typ  
0.90typ  
81.5typ  
83.0typ  
81.5typ  
83.0typ  
82.5typ  
84.5typ  
82.5typ  
84.5typ  
82.5typ  
84.5typ  
EFFICIENCY[%]  
INPUT  
POWER FACTOR (Io=100%)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)  
3.3  
5
12  
15  
24  
36  
48  
CURRENT[A]  
15.0  
15.0  
6.3  
5.0  
3.2  
2.1  
1.6  
*4  
*4  
*1  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
0 to +50C  
RIPPLE[mVp-p]  
*1  
*1  
-10 - 0C  
0 to +50C  
RIPPLE NOISE[mVp-p]  
*1  
OUTPUT  
-10 - 0C  
0 to +50C 50max  
TEMPERATURE REGULATION[mV]  
-10 to +50  
C
60max  
20max  
*
2
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
Fixed (“Y”option is available for adjusting output voltage between 10%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
2.85 to 3.63  
3.30 to 3.40  
OUTPUT VOLTAGE SETTING[V]  
4.90 to 5.30  
11.50 to 12.50  
14.40 to 15.60  
23.00 to 25.00  
34.50 to 37.50  
46.00 to 50.00  
55.20 to 67.20  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00  
27.60 to 33.60  
41.40 to 50.40  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
Not provided  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
ISOLATION INPUT-FG  
OUTPUT-FG  
*3  
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing) (Refer to “Derating”, Instruction Manual 3), 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN62368-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*5  
Complies with IEC61000-3-2 (Class A)  
50X33.5X150mm [1.97X1.32X5.91 inches] (WXHXD) / 230g max (with chassis & cover : 440g max)  
OTHERS  
*3  
Convection (Refer to “Derating”, Instruction Manual 3)  
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm  
from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:  
RM103).  
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at  
25C, with the input voltage held constant at the rated input/output.  
*3 Derating is required.  
*4 Please contact us about dynamic load and input response.  
*5 Please contact us about another class.  
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse load.  
June 26, 2020  
LFA-10  
LFA75F  
Block diagram  
FUSE  
250V3.15A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
AC IN 85 264V  
FG  
RECTIFIER  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CURRENT  
SENSING  
Photocoupler  
Photocoupler  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
CONTROL  
External view  
Standard type  
Chassis and cover type  
3-  
f3.5  
Voltage adjust  
(LFA75F-3R3-Y or optional)  
13  
Name plate  
FG  
2-f4.5  
0.5  
4-M4  
Mounting Hole  
5.5  
169  
Mounting Hole  
[0.51]  
[0.22]  
[6.65]  
5
FG  
CN2  
CN2  
1
5
3
FG  
Input(N)  
Input(L)  
3
Input(N)  
Input(L)  
Output(-)  
Output(+)  
1
3
4
Output(-)  
Output(+)  
1
3
4
CN1  
1
6
CN1  
6
4
Point A  
Point B  
[0.16]  
0.5  
Mounting Hole  
5
140  
[0.2]  
[5.51]  
150  
[5.91]  
180  
[7.09]  
0.5  
f4.5  
169  
5.5  
[0.22]  
[6.65]  
2-M4  
Mounting Hole  
1  
PCB t=1.6  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN1  
CN2  
Tolerance : 1 [ 0.04]  
Weight : 230g max (with chassis & cover : 440g max)  
PCB material / thickness : CEM3 / 1.6mm  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-6 1-1123722-6  
1 to 3  
-V  
AC(N)  
FG  
4 to 6  
+V  
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max  
(Mfr:Tyco Electronics)  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 6.  
Keep drawing current per pin below 5A for CN2.  
June 26, 2020  
LFA-11  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
100  
F
-O -O  
5 6  
LFA100F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-04-472  
R
*1  
6Optional  
C: with Coating  
G: Low leakage current  
H: with the function to be acceptable  
to output peak current (only 24V)  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
J1: VH(J.S.T.)connector type  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
R: with Remote ON/OFF  
R2: with Remote ON/OFF  
S : with Chassis  
SN: with Chassis & cover  
Y: with Potentiometer  
Please refer to Instruction  
manual 6.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
*
MODEL  
LFA100F-3R3-Y LFA100F-5-Y LFA100F-12 LFA100F-15 LFA100F-24 LFA100F-24-H LFA100F-36 LFA100F-48  
*5  
*5  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
66  
3.3V 20A  
100  
5V 20A  
102  
12V 8.5A  
100.5  
15V 6.7A  
103.2  
24V 4.3A  
103.2 (129.6)  
100.8  
100.8  
48V 2.1A  
24V 4.3 (5.4)A 36V 2.8A  
SPECIFICATIONS  
MODEL  
LFA100F-3R3-Y LFA100F-5-Y LFA100F-12 LFA100F-15 LFA100F-24 LFA100F-24-H LFA100F-36 LFA100F-48  
*4  
VOLTAGE[V]  
AC85 - 264 1f(Refer to “Derating”, Instruction Manual 1 and 3)  
ACIN 100V 0.9typ (Io=100%)  
ACIN 200V 0.5typ (Io=100%)  
1.3typ (Io=100%)  
0.7typ (Io=100%)  
CURRENT[A]  
FREQUENCY[Hz]  
50 / 60 (47 - 63)  
ACIN 100V 77.0typ  
ACIN 200V 79.0typ  
ACIN 100V 0.98typ  
ACIN 200V 0.92typ  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
82.0typ  
84.0typ  
0.99typ  
0.95typ  
82.0typ  
84.5typ  
83.0typ  
85.5typ  
84.0typ  
87.0typ  
84.0typ  
87.0typ  
84.0typ  
87.0typ  
84.5typ  
87.0typ  
EFFICIENCY[%]  
INPUT  
POWER FACTOR (Io=100%)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)  
3.3  
5
12  
15  
24  
24  
36  
48  
*5  
*7  
*7  
*2  
CURRENT[A]  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20  
20  
8.5  
6.7  
4.3  
4.3 (Peak 5.4)  
96max  
2.8  
2.1  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
150max  
240max  
320max  
300max  
360max  
240max  
290max  
96max  
0 to +50C  
RIPPLE[mVp-p]  
*2  
*2  
-10 - 0C  
0 to +50C  
RIPPLE NOISE[mVp-p]  
*2  
OUTPUT  
-10 - 0C  
0 to +50C 50max  
TEMPERATURE REGULATION[mV]  
-10 to +50  
C
60max  
20max  
*
3
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
2.85 to 3.63 4.50 to 5.50 Fixed (“Y”option is available for adjusting output voltage)  
3.30 to 3.40 5.00 to 5.15 11.50 to 12.50 14.40 to 15.60  
OUTPUT VOLTAGE SETTING[V]  
23.00 to 25.00  
23.00 to 25.00  
34.50 to 37.50  
46.00 to 50.00  
55.20 to 67.20  
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00  
27.60 to 33.60  
27.60 to 33.60  
41.40 to 50.40  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT RC  
Not provided  
Option (Refer to Instruction Manual)  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)  
.
*6  
INPUT-FG  
ISOLATION  
.
*6  
*6  
*4  
OUTPUT RC-FG  
OUTPUT-RC  
OPERATING TEMP.,HUMID.AND ALTITUDE  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to “Derating”, Instruction Manual 3), 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN62368-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*8  
Complies with IEC61000-3-2 (Class A)  
62X33.5X155mm [2.44X1.32X6.10 inches] (WXHXD) / 280g max (with chassis & cover : 480g max)  
OTHERS  
*4  
Convection (Refer to “Derating”, Instruction Manual 3)  
*1 Specification is changed at option, refer to Instruction Manual.  
at the rated input/output.  
*8 Please contact us about another class.  
*2 This is the value that measured on measuring board with *4 Derating is required.  
*
To meet the specifications. Do not operate over-loaded  
condition.  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
*5 ( ) means peak current. There is a possibility that an internal  
device is damaged when the specification is exceeded. Please *  
Parallel operation is not possible.  
contact us about the detail.  
*
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of  
pulse load.  
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when Remote ON/OFF (optional) is added.  
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.  
June 26, 2020  
LFA-12  
LFA100F  
Block diagram  
FUSE  
250V3.15A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
FG  
Photocoupler  
OPTION  
CURRENT  
SENSING  
RC  
E
EXTERNAL  
SOURCE  
Photocoupler  
Photocoupler  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CONTROL  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
INVERTER  
CONTROL  
RECTIFIER  
AND  
FILTER  
TRANSFORMER  
DC OUT  
External view  
External size of option is different from standard model.  
Standard type  
Chassis and cover type  
173 0.5  
[6.81]  
6
[0.24]  
4-M4  
Mounting Hole  
2-f4.5  
Connector for  
Name plate  
3-f3.5  
Mounting Hole  
FG  
Remote ON/OFF  
(Optional)  
1
2
1
1
2
1
CN4  
FG  
Input(N)  
Input(L)  
FG  
Input(N)  
Input(L)  
5
5
3
CN2  
CN2  
3
Output(-)  
Output(-)  
1
1
4
5
4
5
CN1  
CN1  
Output(+)  
Output(+)  
8
8
4
[0.16]  
16.5  
Point A  
Point B  
Voltage adjust  
(LFA100F-3R3-Y,LFA100F-5-Y or Optional)  
Mounting Hole  
185  
[7.28]  
[0.65]  
5
[0.2]  
[5.71] 0.5  
145  
6
173 0.5  
[6.81]  
f4.5  
155  
[0.24]  
[6.1]  
2-M4  
Mounting Hole  
PCB t=1.6  
1  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Connector type  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
<PIN CONNECTION>  
CN4 Option (Mfr:J.S.T)  
CN1  
CN2  
PIN No.  
1
2
Contents  
RC(+)  
RC(-)  
Pin No.  
Input  
AC(L)  
Pin No. Output  
1
2
3
4
5
1 to 4  
-V  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Chain  
Loose  
Chain  
Loose  
AC(N)  
FG  
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-8 1-1123722-8  
Barrier strip type  
Model B2B-XH-A  
Mating Connector (Terminal)  
XHP-2  
5 to 8  
+V  
(Mfr:Tyco Electronics)  
Keep drawing current per pin below 5A for CN2.  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:VH(J.S.T) connector type.  
BXH-001T-P0.6  
or SXH-001T-P0.6  
Tolerance : 1 [ 0.04]  
Weight : 280g max (with chassis & cover : 480g max)  
PCB material : CEM3  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max  
June 26, 2020  
LFA-13  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
150  
F
-O -O  
5 6  
LFA150F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-04-472  
R
*1  
6Optional  
C: with Coating  
G: Low leakage current  
H: with the function to be acceptable  
to output peak current (only 24V)  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
J1: VH(J.S.T.)connector type  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
R: with Remote ON/OFF  
R2: with Remote ON/OFF  
S : with Chassis  
SN: with Chassis & cover  
Y: with Potentiometer  
Please refer to Instruction  
manual 6.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
*
MODEL  
LFA150F-3R3-Y LFA150F-5-Y LFA150F-12 LFA150F-15 LFA150F-24 LFA150F-24-H LFA150F-36 LFA150F-48  
*5  
*5  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
99  
3.3V 30A  
150  
5V 30A  
150  
12V 12.5A  
150  
15V 10A  
151.2  
24V 6.3A  
151.2 (189.6) 151.2  
24V 6.3 (7.9)A 36V 4.2A  
153.6  
48V 3.2A  
SPECIFICATIONS  
MODEL  
LFA150F-3R3-Y LFA150F-5-Y LFA150F-12 LFA150F-15 LFA150F-24 LFA150F-24-H LFA150F-36 LFA150F-48  
*4  
VOLTAGE[V]  
AC85 - 264 1f(Refer to “Derating”, Instruction Manual 1 and 3)  
ACIN 100V 1.4typ  
ACIN 200V 0.7typ  
(
Io=100%)  
Io=100%)  
2.0typ (Io=100%)  
1.0typ (Io=100%)  
CURRENT[A]  
(
FREQUENCY[Hz]  
50 / 60 (47 - 63)  
ACIN 100V 80.0typ  
82.5typ  
85.5typ  
0.99typ  
0.95typ  
82.5typ  
85.0typ  
84.0typ  
86.5typ  
85.0typ  
87.5typ  
85.0typ  
87.5typ  
85.0typ  
87.5typ  
85.5typ  
88.0typ  
EFFICIENCY[%]  
INPUT  
ACIN 200V 82.0typ  
ACIN 100V 0.98typ  
ACIN 200V 0.92typ  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
POWER FACTOR (Io=100%)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)  
3.3  
5
12  
15  
24  
24  
36  
48  
*5  
*7  
*7  
*2  
CURRENT[A]  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
30  
30  
12.5  
10  
6.3  
6.3 (Peak 7.9)  
96max  
4.2  
3.2  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
150max  
240max  
320max  
300max  
360max  
240max  
290max  
96max  
0 to +40C  
RIPPLE[mVp-p]  
*2  
*2  
-10 - 0C  
0 to +40C  
RIPPLE NOISE[mVp-p]  
*2  
OUTPUT  
-10 - 0C  
0 to +40C 50max  
TEMPERATURE REGULATION[mV]  
-10 to +40  
C
60max  
20max  
*
3
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
2.85 to 3.63 4.50 to 5.50 Fixed (“Y”option is available for adjusting output voltage)  
3.30 to 3.40 5.00 to 5.15 11.50 to 12.50 14.40 to 15.60  
OUTPUT VOLTAGE SETTING[V]  
23.00 to 25.00  
23.00 to 25.00  
34.50 to 37.50  
46.00 to 50.00  
55.20 to 67.20  
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00  
27.60 to 33.60  
27.60 to 33.60  
41.40 to 50.40  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT RC  
Not provided  
Option (Refer to Instruction Manual)  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)  
.
*6  
INPUT-FG  
ISOLATION  
.
*6  
*6  
*4  
OUTPUT RC-FG  
OUTPUT-RC  
OPERATING TEMP.,HUMID.AND ALTITUDE  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to “Derating”, Instruction Manual 3), 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN62368-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*8  
Complies with IEC61000-3-2 (Class A)  
75X37.0X160mm [2.95X1.46X6.30 inches] (WXHXD) / 390g max (with chassis & cover : 650g max)  
OTHERS  
*4  
Convection (Refer to “Derating”, Instruction Manual 3)  
*1 Specification is changeed at option, refer to Instruction Manual.  
at the rated input/output.  
*8 Please contact us about another class.  
*2 This is the value that measured on measuring board with *4 Derating is required.  
*
To meet the specifications. Do not operate over-loaded  
condition.  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
*5 ( ) means peak current. There is a possibility that an internal  
device is damaged when the specification is exceeded. Please *  
Parallel operation is not possible.  
contact us about the detail.  
*
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of  
pulse load.  
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when remote control (optional) is added.  
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.  
June 26, 2020  
LFA-14  
LFA150F  
Block diagram  
FUSE  
250V5A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
FG  
Photocoupler  
OPTION  
CURRENT  
SENSING  
RC  
E
EXTERNAL  
SOURCE  
Photocoupler  
Photocoupler  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CONTROL  
INVERTER  
CONTROL  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
RECTIFIER  
AND  
FILTER  
TRANSFORMER  
DC OUT  
External view  
External size of option is different from standard model.  
Standard type  
Chassis and cover type  
6
2-f4.5  
176 0.5  
[6.93]  
4-M4  
Mounting Hole  
FG  
Name plate  
3-f3.5  
Mounting Hole  
Point A  
Point B  
[0.24]  
1
1
FG  
5
3
FG  
Input(N)  
Input(L)  
5
3
CN3  
CN3  
Input(N)  
Output(-)  
Output(-)  
1
1
Input(L)  
7
1
7
1
CN1  
CN1  
CN2  
CN2  
Output(+)  
Output(+)  
6
6
2
1
2 1  
CN4  
Connector for Remote  
ON/OFF (optional)  
4
Voltage adjust  
[0.16]  
(LFA150F-3R3-Y,LFA150F-5-Y or Optional)  
Mounting Hole  
[01.781]  
188  
[7.4]  
176 0.5  
5
150 0.5  
[5.91]  
160  
[0.2]  
6
f4.5  
[0.24]  
[6.93]  
[6.3]  
2-M4  
Mounting Hole  
PCB t=1.6  
1  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
Connector type  
CN4 Option (Mfr:J.S.T)  
<PIN CONNECTION>  
CN1  
CN2  
CN3  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Pin No. Output  
PIN No.  
1
2
Contents  
RC(+)  
RC(-)  
Chain  
Loose  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-6 1-1123722-6  
CN3 1-1123723-7 1-1123722-7  
AC(N)  
FG  
1 to 7  
-V  
1 to 6  
+V  
Barrier strip type  
Model B2B-XH-A  
Mating Connector (Terminal)  
XHP-2  
BXH-001T-P0.6  
or SXH-001T-P0.6  
Keep drawing current per pin below 5A for CN2,CN3.  
(Mfr:Tyco Electronics)  
Tolerance : 1 [ 0.04]  
Weight : 390g max (with chassis & cover : 650g max)  
PCB material : CEM3  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:VH(J.S.T) connector type.  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max  
June 26, 2020  
LFA-15  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
240  
F
-O -O  
5 6  
LFA240F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-06-472  
R
*1  
6Optional  
C: with Coating  
G: Low leakage current  
H: with the function to be acceptable  
to output peak current (only 24V)  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
J1: VH(J.S.T.)connector type  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
R: with Remote ON/OFF  
R2: with Remote ON/OFF  
S : with Chassis  
SN: with Chassis & cover  
T : Vertical terminal block  
Y: with Potentiometer  
Please refer to Instruction  
manual 6.  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
*
MODEL  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
LFA240F-24  
240  
24V 10A  
LFA240F-24-H  
240 (300)  
24V 10 (12.5)A  
LFA240F-36  
241.2  
36V 6.7A  
LFA240F-48  
240  
48V 5A  
*5  
*5  
SPECIFICATIONS  
MODEL  
LFA240F-24  
LFA240F-24-H  
LFA240F-36  
LFA240F-48  
*4  
VOLTAGE[V]  
AC85 - 264 1f(Refer to “Derating”, Instruction Manual 1 and 3)  
ACIN 100V 3.3typ (Io=100%)  
ACIN 200V 1.7typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
ACIN 100V 84.5typ  
84.5typ  
87.5typ  
84.5typ  
87.5typ  
84.5typ  
87.5typ  
EFFICIENCY[%]  
INPUT  
ACIN 200V 87.5typ  
ACIN 100V 0.99typ  
POWER FACTOR (Io=100%)  
INRUSH CURRENT[A]  
ACIN 200V 0.95typ  
ACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)  
ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)  
24  
24  
36  
48  
*5  
*7  
*7  
*2  
CURRENT[A]  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
10  
10 (Peak12.5)  
96max  
6.7  
5
96max  
150max  
120max  
160max  
150max  
180max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
150max  
240max  
320max  
300max  
360max  
240max  
290max  
96max  
0 to +40C  
RIPPLE[mVp-p]  
*2  
*2  
-10 - 0C  
0 to +40C  
RIPPLE NOISE[mVp-p]  
*2  
OUTPUT  
-10 - 0C  
0 to +40C 240max  
TEMPERATURE REGULATION[mV]  
-10 to +40  
C
290max  
96max  
*
3
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
Fixed (“Y”option is available for adjusting output voltage)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
OUTPUT VOLTAGE SETTING[V]  
23.00 to 25.00  
23.00 to 25.00  
34.50 to 37.50  
46.00 to 50.00  
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically  
OVERVOLTAGE PROTECTION 27.60 to 33.60 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
Not provided  
Option (Refer to Instruction Manual)  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to “Derating”, Instruction Manual 3), 3,000m (10,000feet) max  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT RC  
.
*6  
INPUT-FG  
OUTPUT RC-FG  
ISOLATION  
.
*6  
*6  
*4  
OUTPUT-RC  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN62368-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*8  
Complies with IEC61000-3-2 (Class A)  
84X46.5X180mm [3.31X1.83X7.09 inches] (WXHXD) / 550g max (with chassis & cover : 880g max)  
OTHERS  
*4  
Convection (Refer to “Derating”, Instruction Manual 3)  
*1 Specification is changeed at option, refer to Instruction Manual.  
at the rated input/output.  
*8 Please contact us about another class.  
*2 This is the value that measured on measuring board with *4 Derating is required.  
*
To meet the specifications. Do not operate over-loaded  
condition.  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
*5 ( ) means peak current. There is a possibility that an internal  
device is damaged when the specification is exceeded. Please *  
Parallel operation is not possible.  
contact us about the detail.  
*
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of  
pulse load.  
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when remote control (optional) is added.  
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.  
June 26, 2020  
LFA-16  
LFA240F  
Block diagram  
FUSE  
250V10A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
FG  
Photocoupler  
OPTION  
CURRENT  
SENSING  
RC  
E
EXTERNAL  
SOURCE  
Photocoupler  
Photocoupler  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CONTROL  
INVERTER  
CONTROL  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
RECTIFIER  
AND  
FILTER  
TRANSFORMER  
DC OUT  
External view  
External size of option is different from standard model.  
Standard type  
Chassis and cover type  
Connector for Remote  
ON/OFF (Optional)  
200 0.5  
[7.87]  
6
[0.24]  
2-f4.5  
4-M4  
Mounting Hole  
16.5  
[0.65]  
4-f3.5  
Mounting Hole  
FG  
Voltage adjust(Optional)  
Name plate  
1
2
1
2
CN4  
1
1
FG  
FG  
5
3
5
3
CN3  
CN3  
Input(N)  
Input(L)  
Input(N)  
Input(L)  
Output(-)  
Output(-)  
1
1
CN1  
CN1  
7
1
7
1
CN2  
CN2  
Output(+)  
Output(+)  
6
6
4
[0.16]  
89 0.5  
[3.5]  
Point A Point B  
Mounting Hole  
212  
[8.35]  
170 0.5  
[6.69]  
5
[0.2]  
6
f4.5  
200 0.5  
180  
[7.09]  
[7.87]  
[0.24]  
2-M4  
Mounting Hole  
1  
PCB t=1.6  
1 Surface mount device  
5 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points. Please refer to  
Instruction Manual 3.  
Connector type  
<PIN CONNECTION>  
CN1  
CN2  
CN3  
CN4 Option (Mfr:J.S.T)  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Pin No. Output  
PIN No.  
Contents  
RC(+)  
Chain  
Loose  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
1
2
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-6 1-1123722-6  
CN3 1-1123723-7 1-1123722-7  
RC(-)  
AC(N)  
1 to 7  
-V  
1 to 6  
+V  
Barrier strip type  
Model B2B-XH-A  
Mating Connector (Terminal)  
XHP-2  
FG  
Keep drawing current per pin below 5A for CN2,CN3.  
(Mfr:Tyco Electronics)  
Tolerance : 1 [ 0.04]  
Weight : 550g max (with chassis & cover : 880g max)  
PCB material : CEM3  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:VH(J.S.T) connector type.  
BXH-001T-P0.6  
or SXH-001T-P0.6  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max  
June 26, 2020  
LFA-17  
Ordering information  
AC-DC Power Supplies Open Frame/ Enclosed Type  
LF  
A
300  
F
-O -O  
5 6  
LFA300F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-06-472  
R
*1  
6Optional  
C: with Coating  
G: Low leakage current  
H: with the function to be acceptable  
to output peak current  
(Only 24V, 30V, 36V and 48V)  
J : EP (Tyco Electronics) connector type  
(Except 3.3V and 5V)  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
J1  
:
VH (J.S.T.) connector type  
(Except 3.3V and 5V)  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
R: with Remote ON/OFF  
R2: with Remote ON/OFF  
S : with Chassis  
SNF  
:
with Chassis & cover & fan  
(Only 5V, 12V and 24V)  
Holizontal terminal block  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
T1  
:
*
Please refer to Instruction manual 6.  
MODEL  
LFA300F-3R3-TY LFA300F-5-TY LFA300F-12-TY LFA300F-15-TY LFA300F-24-TY LFA300F-24-HTY LFA300F-30-TY LFA300F-36-TY LFA300F-48-TY  
*5  
MAX OUTPUT WATTAGE[W]  
198  
300  
324  
330  
336  
336 (456) 330  
338.4  
336  
Convection  
Forced air  
3.3V 40A  
3.3V 60A  
5V 40A  
5V 60A  
12V 17A  
12V 27A  
15V 14A  
15V 22A  
24V 12.5A 24V 12.5 (19)A 30V 10A  
36V 8.4A  
36V 9.4A  
48V 6.3A  
48V 7A  
*5  
DC OUTPUT  
24V 14A  
24V 14 (19)A 30V 11A  
SPECIFICATIONS  
MODEL  
LFA300F-3R3-TY LFA300F-5-TY  
LFA300F-12-TY  
LFA300F-15-TY  
LFA300F-24-TY  
LFA300F-24-HTY LFA300F-30-TY  
LFA300F-36-TY  
LFA300F-48-TY  
*4  
VOLTAGE[V]  
AC85 - 264 1f(Refer to “Derating”, Instruction Manual 1 and 3)  
ACIN 100V 2.7typ (Io=100%) 4.1typ (Io=100%)  
ACIN 200V 1.4typ (Io=100%) 2.0typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
ACIN 100V 75.0typ  
ACIN 200V 77.0typ  
ACIN 100V 0.98typ  
ACIN 200V 0.92typ  
79.0typ  
82.5typ  
0.99typ  
0.95typ  
80.0typ  
83.0typ  
81.5typ  
84.5typ  
85.0typ  
88.0typ  
85.0typ  
88.0typ  
85.5typ  
88.0typ  
85.5typ  
88.0typ  
85.5typ  
88.0typ  
EFFICIENCY[%]  
INPUT  
POWER FACTOR (Io=100%)  
ACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)  
ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)  
3.3  
5
12  
15  
24  
24  
30  
36  
48  
Convection 40  
Forced air 60  
40  
60  
17  
27  
14  
22  
12.5  
14  
12.5 (Peak19) 10  
14 (Peak19) 11  
8.4  
9.4  
6.3  
7
*5  
CURRENT[A]  
*7  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
40max  
80max  
140max  
120max  
160max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
96max  
144max  
144max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
192max  
240max  
150max  
200max  
250max  
300max  
480max  
600max  
192max  
*7  
*2  
*2  
*2  
150max  
240max  
320max  
300max  
360max  
240max  
290max  
96max  
240max  
150max  
200max  
250max  
300max  
360max  
450max  
144max  
0 to +40C  
RIPPLE[mVp-p]  
-10 - 0C  
0 to +40C  
OUTPUT  
RIPPLE NOISE[mVp-p]  
*2  
-10 - 0C  
0 to +40C 50max  
TEMPERATURE REGULATION[mV]  
-10 to +40  
C
60max  
20max  
*
3
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
OUTPUT VOLTAGE SETTING[V]  
2.85 to 3.63 4.50 to 5.50  
3.30 to 3.40 5.00 to 5.15  
10.80 to 13.20 13.50 to 16.50 21.60 to 27.50 21.60 to 27.50 27.00 to 33.00 32.40 to 39.60 39.60 to 52.80  
12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 24.00 to 24.96 30.00 to 31.20 36.00 to 37.44 48.00 to 49.92  
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically  
OVERVOLTAGE PROTECTION  
4.00 to 5.25  
5.75 to 7.00  
13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 27.60 to 33.60 34.50 to 42.00 41.40 to 50.40 55.20 to 67.20  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
Not provided  
Option (Refer to Instruction Manual)  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)  
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to “Derating”, Instruction Manual 3), 3,000m (10,000feet) max  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT RC  
.
*6  
INPUT-FG  
OUTPUT RC-FG  
ISOLATION  
.
*6  
*6  
*4  
OUTPUT-RC  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN62368-1, EN60065, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B  
SAFETY AND  
NOISE  
REGULATIONS  
*8  
Complies with IEC61000-3-2 (Class A)  
95X52.5X222mm [3.74X2.07X8.74 inches] (WXHXD) (without terminal block) / 810g max (with chassis & cover : 1,270g max)  
OTHERS  
*4  
Convection / Forced air (Refer to “Derating”, Instruction Manual 3)  
*1 Specification is changeed at option, refer to Instruction Manual.  
at the rated input/output.  
*8 Please contact us about another class.  
*2 This is the value that measured on measuring board with *4 Derating is required.  
*
To meet the specifications. Do not operate over-loaded  
condition.  
capacitor of 22mF at 150mm from output terminal.  
Measured by 20MHz oscilloscope or Ripple-Noise meter  
(Equivalent to KEISOKU-GIKEN: RM103).  
*5 ( ) means peak current. There is a possibility that an internal  
device is damaged when the specification is exceeded. Please *  
Parallel operation is not possible.  
contact us about the detail.  
*
*
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of  
pulse load.  
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when remote control (optional) is added.  
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.  
June 26, 2020  
LFA-18  
LFA300F  
Block diagram  
FUSE  
250V10A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
FG  
Photocoupler  
OPTION  
CURRENT  
SENSING  
RC  
EXTERNAL  
SOURCE  
E
Photocoupler  
Photocoupler  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CONTROL  
INVERTER  
CONTROL  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
RECTIFIER  
AND  
FILTER  
TRANSFORMER  
DC OUT  
External view  
External size of option is different from standard model.  
Standard type  
Connector for  
Point B  
4-f3.5  
Mounting Hole  
Name plate  
FG  
Point C  
Point D  
Remote ON/OFF  
(Optional)  
M4  
1
2
CN4  
FG  
TB2  
Input(N)  
Output(-)  
Input(L)  
TB1  
Output(+)  
M4  
4
5
[0.2]  
109 0.5  
[4.29]  
[0.16]  
Voltage adjust  
Mounting Hole  
46.5  
[1.83]  
Point A  
212 0.5  
[8.35]  
Connector type  
CN4 Option (Mfr:J.S.T)  
222  
[8.74]  
PIN No.  
Contents  
RC(+)  
1
2
RC(-)  
Barrier strip type  
Model B2B-XH-A  
Mating Connector (Terminal)  
XHP-2  
PCB t=1.6  
1  
1 Surface mount device  
5 Mounting holes are existing.  
BXH-001T-P0.6  
or SXH-001T-P0.6  
Tolerance : 1 [ 0.04]  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Weight : 810g max (with chassis & cover : 1,270g max)  
PCB material : CEM3  
Dimensions in mm, [ ]=inches  
Screw tightening torque : M4 1.6N-m (16.9kgf-cm) max  
Point A, Point B, Point C, Point D are thermometry points.  
Please refer to Instruction Manual 3.  
Keep drawing current per pin below 20A for TB2.  
June 26, 2020  
LFA-19  
LFA-series  
Assembling and Installation Method  
Installation method  
This power supply is manufactured by SMD technology.The stress  
to P.C.B like twisting or bending causes the defect of the unit, so  
handle the unit with care.  
¡
d2  
CN1  
d1= 8mm min  
In case of metal chassis, keep the distance between d1 & d2 for  
to insulate between lead of component and metal chassis, use the  
spacer of 8mm or more between d1. If it is less than d1 & d2, in-  
sert the insulation sheet between power supply and metal chassis.  
¡
d2  
CN1  
d2  
d2  
d2 = 4mm min  
d2  
There is a possibility that it is not possible to cool enough when  
the power supply is used by the sealing up space as showing in  
right figure.Please use it after confi rming the temperature of point  
A and point B of Instruction Manual 3.  
¡
Case  
Power supply  
(A)  
(B)  
CN1  
(C)  
(F) mounting is not possible when unit is with case cover, but if  
need to operate unit by (F) positioning with case cover, tempera-  
ture / load derating is necessary. For more details, please contact  
our sales or engineering departments.  
¡
CN1  
CN1  
Standard  
Position  
(D)  
CN1  
(E)  
(F)  
CN1  
CN1  
Mounting screw  
The mounting screw should be M3. The hatched area shows the allowance of metal parts for mounting.  
¡
LFA10F, LFA15F  
LFA30F, LFA50F, LFA75F, LFA100F, LFA150F  
¿
¿
8
8
8
8
8
8
8
8
CN1  
CN1  
8
8
8
8
Unit [mm]  
8
Unit [mm]  
LFA240F, LFA300F  
¿
8
8
8
8
CN1, TB1  
8
8
Unit [mm]  
8
8
8
If metallic fi ttings are used on the component side of the board,ensure there is no contact with surface mounted components.  
This product uses SMD technology.Please avoid the PCB installation method which includes the twisting stress or the bending stress.  
*Recommendation to electrically connect FG to metal chassis for reducing noise.  
¡
¡
June 26, 2020  
LFA-20  
LFA-series  
Derating  
Derating curve for input voltage  
¿
¿
[%]  
100  
80  
85 90  
[AC V]  
LFA10F Ambient temperature derating curve  
(Reference value)  
LFA15F Ambient temperature derating curve  
(Reference value)  
¿
(A), (D), (E), (F)mounting  
(B), (C)mounting  
1
1
(E), (F)mounting  
(A), (B), (C), (D)mounting  
1
1
2(A) ~ (F)  
mounting  
2(A) ~ (F)  
mounting  
100  
80  
100  
80  
1
2
Convection  
Forced air (0.5m3 / min)  
1
2
Convection  
Forced air (0.5m3 / min)  
60  
60  
40  
35  
40  
35  
20  
20  
0
-10  
0
-10  
[
]
[
]
[
]
0
10  
20  
30  
40  
50 40  
60 50  
70 60  
[
]
[
]
[
]
[
]
0
10  
20  
30  
40 30  
50 40  
60 50  
70 60  
Ambient temperature [C]  
*Inside[ ] is with case cover  
Ambient temperature [C]  
*Inside[ ] is with case cover  
LFA30F Ambient temperature derating curve  
(Reference value)  
LFA50F Ambient temperature derating curve  
(Reference value)  
¿
¿
(D)mounting  
1
(D), (E)mounting  
(A), (C)mounting  
1
1
(C), (E)mounting  
(B)mounting  
1
1
(F)mounting  
1
(B)mounting  
1
(F)mounting  
1
(A)mounting  
1
100  
80  
60  
40  
20  
0
100  
80  
60  
40  
20  
0
2(A) ~ (F)  
mounting  
2(A) ~ (F)  
mounting  
1
2
Convection  
Forced air (0.5m3 / min)  
1
2
Convection  
Forced air (0.5m3 / min)  
[
]
[
]
[
]
[
]
-10  
0
10  
20  
30  
40 30  
50 40  
60 50  
70 60  
[
]
[
]
[
]
[
]
-10  
0
10  
20  
30 [10] 40 20  
50 30  
60 40  
70 50  
Ambient temperature [C]  
*Inside[ ] is with case cover  
Ambient temperature [C]  
*Inside[ ] is with case cover  
LFA75F Ambient temperature derating curve  
(Reference value)  
¿
(D)mounting  
(C)mounting  
1
1
(E), (F)mounting  
1
(A), (B)mounting  
1
100  
80  
60  
40  
20  
0
2(A) ~ (F)  
mounting  
1
2
Convection  
Forced air (0.5m3 / min)  
[
]
[
]
[
]
[
]
[
]
-10  
0
10  
20  
30 10  
40 20  
50 30  
60 40  
70 50  
Ambient temperature [C]  
*Inside[ ] is with case cover  
LFA100F Ambient temperature derating curve  
(Reference value)  
100F- -SN Ambient temperature derating  
O
¿
¿LFA  
curve (Reference value)  
(A)mounting  
1
2(A) ~ (F)  
mounting  
(C)mounting  
(B)mounting  
(A)mounting  
1
1
(D), (E)mounting  
1
1
(D), (E), (F)mounting  
1
(C)mounting  
1
(B)mounting  
1
100  
100  
2(A) ~ (F)  
80  
75  
mounting  
80  
75  
60  
1
2
Convection  
Forced air (0.5m3 / min)  
60  
50  
40  
1
2
Convection  
Forced air (0.5m3 / min)  
40  
20  
10  
20  
0
-10  
0
-10  
0
10  
20  
30 35 40 45 50  
60  
0
10  
20  
30 35 40 45 50 55 60  
70  
Ambient temperature [C]  
Ambient temperature [C]  
June 26, 2020  
LFA-21  
LFA-series  
Derating  
LFA150F Ambient temperature derating curve  
(Reference value)  
LFA150F- -SN Ambient temperature derating  
O
¿
¿
¿
¿
curve (Reference value)  
(B)mounting  
(B)mounting  
1
1
(C)mounting  
(C)mounting  
1
1
(A)mounting  
1
(D), (E), (F)mounting  
1
(D), (E)mounting  
(A)mounting  
1
1
100  
100  
2(A) ~ (F)  
mounting  
2(A) ~ (F)  
mounting  
80  
70  
60  
80  
70  
60  
50  
40  
30  
20  
1
2
Convection  
Forced air (0.5m3 / min)  
1
Convection  
Forced air (0.5m3 / min)  
2
40  
30  
20  
0
-10  
0
-10  
0
10  
20 25 30 35 40 45 50 55 60 65 70  
0
5
10  
20  
25  
30  
40 45  
50  
55  
Ambient temperature [C]  
Ambient temperature [C]  
LFA240F Ambient temperature derating curve  
(Reference value)  
LFA240F- -SN Ambient temperature derating  
O
¿
curve (Reference value)  
(B)mounting  
(B)mounting  
1
1
(C)mounting  
(C)mounting  
1
(D), (F)mounting 1  
(D)mounting  
1
1
(A)mounting  
1
(E)mounting  
1
(E)mounting  
1
(A)mounting  
1
100  
80  
100  
2(A) ~ (F)  
mounting  
2(A) ~ (F)  
mounting  
80  
70  
60  
60  
1
2
Convection  
Forced air (0.5m3 / min)  
1
2
Convection  
Forced air (0.5m3 / min)  
40  
40  
25  
20  
25  
20  
10  
0
-10  
0
-10  
0
10 15 20  
30  
40  
50  
60  
70  
0
5
10 15  
20 25 30  
40  
50  
60  
Ambient temperature [C]  
Ambient temperature [C]  
LFA300F Ambient temperature derating curve  
(Reference value)  
(B), (C)mounting  
1
(E), (F)mounting  
1
(D)mounting  
1
(A)mounting  
1
100  
80  
2(A) ~ (F)  
mounting  
1
2
Convection  
Forced air  
60  
50  
(1.0m3 / min):3.3V/5V/12V/15V  
(0.5m3 / min):24V/30V/36V/48V  
40  
20  
0
-10  
0
10  
20 25 30  
40  
50  
60  
70  
Ambient temperature [C]  
Output power[W]  
Output  
voltage  
1Convection  
132.0  
2Forced air  
198.0  
3.3V  
5V  
200.0  
300.0  
12V  
15V  
24V  
30V  
36V  
48V  
204.0  
324.0  
210.0  
330.0  
300.0  
336.0  
300.0  
330.0  
302.4  
338.4  
302.4  
336.0  
The operative ambient temperature is different by with / without chassis cover or mounting position.  
Note: In the hatched area, the specification of Ripple, Ripple Noise is different from other area.  
Make sure the temperature at point A and point B is less than the temperatures shown in Instruction Manual 3.  
¡
¡
¡
The ambient temperature should be measured 5 to 10 cm away from the power supply so that it won’t be influenced by the heat from the  
power supply. Please consult us for more details.  
Instruction Manual  
It is neccessary to read the “Instruction Manual” and “Before using our product” before you use our product.  
LFA  
NOTICE  
Instruction Manual  
https://en.cosel.co.jp/product/powersupply/LFA/  
https://en.cosel.co.jp/technical/caution/index.html  
Before using our produc  
June 26, 2020  
LFA-22  
LFA-series  
Basic Characteristics Data  
Series/Parallel  
Switching  
frequency  
[kHz]  
Input  
current  
[A]  
Inrush  
current  
protection  
PCB/Pattern  
operation availability *2  
Model  
LFA10F  
LFA15F  
LFA30F  
LFA50F  
LFA75F  
LFA100F  
LFA150F  
LFA240F  
LFA300F  
Circuit method  
Flyback converter  
Flyback converter  
Flyback converter  
Single Double  
Series  
Parallel  
sided sided operation operation  
Material  
*1  
100  
100  
130  
0.26  
0.35  
0.65  
0.67  
1.0  
LF  
CEM-3  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
No  
No  
No  
Thermistor  
Thermistor  
Thermistor  
Thermistor  
Thermistor  
Thermistor  
SCR  
CEM-3  
CEM-3  
CEM-3  
CEM-3  
CEM-3  
CEM-3  
CEM-3  
CEM-3  
Active filter  
Flyback converter  
Active filter  
60-440  
130  
60-440  
130  
60  
Flyback converter  
Active filter  
1.3  
Yes  
Yes  
Yes  
Yes  
Forward converter  
Active filter  
140  
60  
2.0  
Forward converter  
Active filter  
140  
60  
3.3  
Forward converter  
Active filter  
140  
60  
4.1  
SCR  
Forward converter  
140  
*1 The value of input current is at ACIN 100V and rated load.  
*2 Refer to Instruction Manual 2.  
June 26, 2020  
LFA-23  

相关型号:

LFA100F-24-RY

AC/DC CONVERTER 24V
COSEL

LFA100F-24-S

AC/DC CONVERTER 24V
COSEL

LFA100F-24-SC

AC/DC CONVERTER 24V
COSEL

LFA100F-24-SCG

AC/DC CONVERTER 24V
COSEL

LFA100F-24-SCJ1

AC/DC CONVERTER 24V
COSEL

LFA100F-24-SCR

AC/DC CONVERTER 24V
COSEL

LFA100F-24-SCR2

AC/DC CONVERTER 24V
COSEL

LFA100F-24-SCY

AC/DC CONVERTER 24V
COSEL

LFA100F-24-SG

AC/DC CONVERTER 24V
COSEL

LFA100F-24-SGJ1

AC/DC CONVERTER 24V
COSEL

LFA100F-24-SGR

AC/DC CONVERTER 24V
COSEL

LFA100F-24-SGR2

AC/DC CONVERTER 24V
COSEL