LMA100F-24-HY [COSEL]

AC/DC CONVERTER 24V;
LMA100F-24-HY
型号: LMA100F-24-HY
厂家: COSEL CO., LTD.    COSEL CO., LTD.
描述:

AC/DC CONVERTER 24V

文件: 总10页 (文件大小:1614K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
AC-DC Power Supplies Medical Type  
Power  
Cost  
Effective  
Rugged  
PCB type  
Safety  
Approvals  
EMI  
OCP  
OVP  
Medical  
electric  
equipment  
World wide  
Inrush  
current  
limiting  
Factor  
Correction  
LMA-series  
Feature  
For medical electric equipment  
CE marking  
Low Voltage Directive  
Internal dual fuses  
RoHS Directive  
Low leakage current  
High power & peak power (option)  
Small and compact PCB construction  
EMS Compliance  
:
EN61204-3, EN61000-6-2  
IEC60601-1-2 (2014), EN60601-1-2 (2015)  
Built-in inrush current, overcurrent and overvoltage protection  
circuits  
Harmonic attenuator (Complies with IEC61000-3-2 class A)  
Universal input (AC85-264V)  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
EN61000-4-11  
Power factor correction  
Safety agency approvals  
ANSI/AAMI ES60601, EN60601-1 3rd  
EMI  
Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B,  
VCCI-B  
5-year warranty  
June 29, 2020  
LMA-1  
Ordering information  
AC-DC Power Supplies Medical Type  
LM  
A
100  
F
-O -O  
5 6  
LMA100F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAM-04-101  
R
*1  
6Optional  
C: with Coating  
G: Low leakage current  
H : with the function to be acceptable  
to output peak current  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
J1: VH(J.S.T.)connector type  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
R: with Remote ON/OFF  
R2: with Remote ON/OFF  
S : with Chassis  
SN: with Chassis & cover  
P :Setting in the overcurrent  
protection rating  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
MODEL  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
LMA100F-24-Y  
103.2  
24V 4.3A  
LMA100F-24-HY  
*2  
103.2 (206.4)  
*2  
24V 4.3A (8.6A)  
SPECIFICATIONS  
MODEL  
LMA100F-24-Y  
LMA100F-24-HY  
VOLTAGE[V]  
AC85 - 264 1f(Refer to “Derating” ,Instruction Manual 1 and 3)  
ACIN 100V 1.4typ (Io=100%)  
ACIN 200V 0.7typ (Io=100%)  
CURRENT[A]  
FREQUENCY[Hz]  
50 / 60 (47 - 63)  
ACIN 100V 84.0typ (Io=100%)  
ACIN 200V 86.0typ (Io=100%)  
84.0typ (Io=100%)  
86.0typ (Io=100%)  
EFFICIENCY[%]  
INPUT  
ACIN 100V 0.99typ (Io=100%)  
ACIN 200V 0.95typ (Io=100%)  
POWER FACTOR  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
CURRENT[A]  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
0.10 / 0.25max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1)  
24  
24  
*2  
4.3  
96max  
150max  
4.3 (Peak 8.6)  
96max  
*7  
*7  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
0 to +50C 120max  
-10 - 0C 160max  
0 to +50C 150max  
-10 - 0C 180max  
0 to +50C 240max  
*3  
RIPPLE[mVp-p]  
*3  
RIPPLE NOISE[mVp-p]  
OUTPUT  
TEMPERATURE REGULATION[mV]  
-10 to +50  
C
290max  
96max  
*
4
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
19.20 to 27.50  
19.20 to 27.50  
24.00 to 24.96  
OUTPUT VOLTAGE SETTING[V]  
24.00 to 24.96  
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically  
OVERVOLTAGE PROTECTION[V] 27.60 to 33.60 27.60 to 33.60  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT RC  
Not provided  
Option (Required external power source.)  
AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) 2MOOP  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) 1MOOP  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
.
*6  
INPUT-FG  
ISOLATION  
.
*6  
*6  
*5  
OUTPUT RC-FG  
OUTPUT-RC  
OPERATING TEMP.,HUMID.AND ALTITUDE  
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)  
-10 to +70C, 20 - 90%RH (Non condensing), (Refer to “Derating”, Instruction Manual 3) 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
IMPACT  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
2
AGENCY APPROVALS (AT ONIY AC input) ANSI/AAMI ES60601-1, EN60601-1 3rd, Complies with IEC60601-1-2 4th Ed.  
SAFETY AND  
NOISE  
REGULATIONS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B  
*8  
Complies with IEC61000-3-2 (Class A)  
62X33X155mm [2.44X1.30X6.10 inches] (WXHXD) / 290g max (with chassis & cover : 470g max)  
OTHERS  
*5  
Convection (Refer to “Derating”, Instruction Manual 3)  
*1 Specification is changed at option, refer to Instruction Manual.  
*2 Peak loading for 10sec. And Duty 40% max.  
*4 Drift is the change in DC output for an eight hour period  
after a half-hour warm-up at 25C, with the input voltage  
held constant at the rated input/output.  
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
( ) means peak current. There is a possibility that an internal device  
is damaged when the specification is exceeded.  
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse load.  
*5 Derating is required.  
*3 This is the value that measured on measuring board with capacitor of *6 Applicable when remote control (optional) is added.  
22mF at 150mm from output terminal.  
*7 Please contact us about dynamic load and input response.  
*8 Please contact us about another class.  
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent  
to KEISOKU-GIKEN: RM103).  
June 29, 2020  
LMA-2  
LMA100F  
Block diagram  
FUSE  
250V3.15A×2  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
FG  
Photocoupler  
OPTION  
CURRENT  
SENSING  
RC  
E
EXTERNAL  
SOURCE  
Photocoupler  
Photocoupler  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CONTROL  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
INVERTER  
CONTROL  
RECTIFIER  
AND  
FILTER  
TRANSFORMER  
DC OUT  
External view  
External size of option is different from standard model.  
Standard type  
Chassis and cover type  
Connector for  
Remote ON/OFF  
173 0.5  
[6.81]  
6
[0.24]  
4-M4  
Mounting Hole  
2- 4.5  
(Optional)  
Name plate  
3- 3.5  
Mounting Hole  
FG  
1
2
1
1
2
1
CN4  
FG  
Input(N)  
Input(L)  
FG  
Input(N)  
Input(L)  
5
3
5
3
CN2  
CN2  
Output(-)  
Output(-)  
1
1
4
5
4
5
CN1  
CN1  
Output(+)  
Output(+)  
8
8
4
Point A  
Point B  
Voltage adjust  
[0.16]  
16.5  
[0.65]  
Mounting Hole  
185  
[7.28]  
173  
145 0.5  
5
[0.2]  
[5.71]  
155  
6
4.5  
[6.81] 0.5  
[0.24]  
[6.1]  
2-M4  
Mounting Hole  
PCB t=1.6  
1  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points.
Connector type  
<PIN CONNECTION>  
CN4 Option (Mfr:J.S.T)  
CN1  
CN2  
PIN No.  
1
2
Contents  
RC(+)  
RC(-)  
Pin No.  
Input  
Pin No. Output  
AC(L)  
1
2
3
4
5
1 to 4  
-V  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Chain  
Loose  
Chain  
Loose  
AC(N)  
FG  
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-8 1-1123722-8  
Barrier strip type  
5 to 8  
+V  
Model B2B-XH-A  
Mating Connector (Terminal)  
XHP-2  
(Mfr:Tyco Electronics)  
Keep drawing current per pin below 5A for CN2.  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:VH(J.S.T) connector type.  
BXH-001T-P0.6  
or SXH-001T-P0.6  
Tolerance : 1 [ 0.04]  
Weight : 290g max (with chassis & cover : 470g max)  
PCB material : CEM3  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
Mounting torque (Mounting hole of chassis) :1.5N m (16kgf cm) max  
June 29, 2020  
LMA-3  
Ordering information  
AC-DC Power Supplies Medical Type  
LM  
A
150  
F
-O -O  
5 6  
LMA150F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAM-04-101  
R
*1  
6Optional  
C: with Coating  
G: Low leakage current  
H : with the function to be acceptable  
to output peak current  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
J1: VH(J.S.T.)connector type  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
R: with Remote ON/OFF  
R2: with Remote ON/OFF  
S : with Chassis  
SN: with Chassis & cover  
P :Setting in the overcurrent  
protection rating  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
MODEL  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
LMA150F-24-Y  
151.2  
24V 6.3A  
LMA150F-24-HY  
*2  
151.2 (302.4)  
*2  
24V 6.3A (12.6A)  
SPECIFICATIONS  
MODEL  
LMA150F-24-Y  
LMA150F-24-HY  
VOLTAGE[V]  
AC85 - 264 1f(Refer to “Derating” ,Instruction Manual 1 and 3)  
ACIN 100V 2.0typ (Io=100%)  
ACIN 200V 1.0typ (Io=100%)  
CURRENT[A]  
FREQUENCY[Hz]  
50 / 60 (47 - 63)  
ACIN 100V 85.0typ (Io=100%)  
ACIN 200V 87.0typ (Io=100%)  
85.0typ (Io=100%)  
87.0typ (Io=100%)  
EFFICIENCY[%]  
INPUT  
ACIN 100V 0.99typ (Io=100%)  
ACIN 200V 0.95typ (Io=100%)  
POWER FACTOR  
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)  
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
CURRENT[A]  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
0.10 / 0.25max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1)  
24  
24  
*2  
6.3  
96max  
150max  
6.3 (Peak 12.6)  
96max  
*7  
*7  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
0 to +50C 120max  
-10 - 0C 160max  
0 to +50C 150max  
-10 - 0C 180max  
0 to +50C 240max  
*3  
RIPPLE[mVp-p]  
*3  
RIPPLE NOISE[mVp-p]  
OUTPUT  
TEMPERATURE REGULATION[mV]  
-10 to +50  
C
290max  
96max  
*
4
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
19.20 to 27.50  
19.20 to 27.50  
24.00 to 24.96  
OUTPUT VOLTAGE SETTING[V]  
24.00 to 24.96  
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically  
OVERVOLTAGE PROTECTION[V] 27.60 to 33.60 27.60 to 33.60  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT RC  
Not provided  
Option (Required external power source.)  
AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) 2MOOP  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) 1MOOP  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
.
*6  
INPUT-FG  
ISOLATION  
.
*6  
*6  
*5  
OUTPUT RC-FG  
OUTPUT-RC  
OPERATING TEMP.,HUMID.AND ALTITUDE  
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)  
-10 to +70C, 20 - 90%RH (Non condensing), (Refer to “Derating”, Instruction Manual 3) 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
IMPACT  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
2
AGENCY APPROVALS (AT ONIY AC input) ANSI/AAMI ES60601-1, EN60601-1 3rd, Complies with IEC60601-1-2 4th Ed.  
SAFETY AND  
NOISE  
REGULATIONS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B  
*8  
Complies with IEC61000-3-2 (Class A)  
75X36.5X160mm [2.95X1.44X6.30 inches] (WXHXD) / 370g max (with chassis & cover : 600g max)  
OTHERS  
*5  
Convection (Refer to “Derating”, Instruction Manual 3)  
*1 Specification is changed at option, refer to Instruction Manual.  
*2 Peak loading for 10sec. And Duty 40% max.  
*4 Drift is the change in DC output for an eight hour period  
after a half-hour warm-up at 25C, with the input voltage  
held constant at the rated input/output.  
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
( ) means peak current. There is a possibility that an internal device  
is damaged when the specification is exceeded.  
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse load.  
*5 Derating is required.  
*3 This is the value that measured on measuring board with capacitor of *6 Applicable when remote control (optional) is added.  
22mF at 150mm from output terminal.  
*7 Please contact us about dynamic load and input response.  
*8 Please contact us about another class.  
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent  
to KEISOKU-GIKEN: RM103).  
June 29, 2020  
LMA-4  
LMA150F  
Block diagram  
FUSE  
250V5A×2  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
FG  
Photocoupler  
OPTION  
CURRENT  
SENSING  
RC  
E
EXTERNAL  
SOURCE  
Photocoupler  
Photocoupler  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CONTROL  
INVERTER  
CONTROL  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
RECTIFIER  
AND  
FILTER  
TRANSFORMER  
DC OUT  
External view  
External size of option is different from standard model.  
Standard type  
Chassis and cover type  
6
[0.24]  
2-f4.5  
4-M4  
Mounting Hole  
176 0.5  
[6.93]  
FG  
Name plate  
3-f3.5  
Mounting Hole  
Point A  
Point B  
1
1
FG  
5
3
1
FG  
Input(N)  
Input(L)  
5
3
CN3  
CN3  
Input(N)  
Output(-)  
Output(-)  
1
Input(L)  
7
1
7
1
CN1  
CN1  
CN2  
CN2  
Output(+)  
Output(+)  
6
6
2
1
2
1
CN4  
Connector for RemoteON/OFF (optional)  
Voltage adjust  
4
[0.16]  
Mounting Hole  
[01.781]  
188  
5
150 0.5  
[7.4]  
[5.91]  
[0.2]  
f4.5  
6
176 0.5  
[6.93]  
160  
[0.24]  
[6.3]  
2-M4  
Mounting Hole  
PCB t=1.6  
1  
1 Surface mount device  
4 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B are thermometry points.
Connector type  
CN4 Option (Mfr:J.S.T)  
<PIN CONNECTION>  
CN1  
CN2  
CN3  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
Pin No. Output  
Pin No. Output  
PIN No.  
1
2
Contents  
RC(+)  
RC(-)  
Chain  
Loose  
Chain  
Loose  
Chain  
Loose  
AC(L)  
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-6 1-1123722-6  
CN3 1-1123723-7 1-1123722-7  
AC(N)  
1 to 7  
-V  
1 to 6  
+V  
Barrier strip type  
FG  
Model B2B-XH-A  
Mating Connector (Terminal)  
XHP-2  
BXH-001T-P0.6  
or SXH-001T-P0.6  
Keep drawing current per pin below 5A for CN2,CN3.  
(Mfr:Tyco Electronics)  
Tolerance : 1 [ 0.04]  
Weight : 370g max (with chassis & cover : 600g max)  
PCB material : CEM3  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:VH(J.S.T) connector type.  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max  
June 29, 2020  
LMA-5  
Ordering information  
AC-DC Power Supplies Medical Type  
LM  
A
240  
F
-O -O  
5 6  
LMA240F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAM-06-101  
R
*1  
6Optional  
C: with Coating  
G: Low leakage current  
H : with the function to be acceptable  
to output peak current  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
J1: VH(J.S.T.)connector type  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
R: with Remote ON/OFF  
R2: with Remote ON/OFF  
S : with Chassis  
SN: with Chassis & cover  
P :Setting in the overcurrent  
protection rating  
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
MODEL  
MAX OUTPUT WATTAGE[W]  
LMA240F-24-Y  
300  
LMA240F-24-HY  
*2  
300 (480)  
Convection  
Forced air  
*2  
24V 10A  
24V 12.5A  
24V 10A (20A)  
DC OUTPUT  
*2  
24V 12.5A (20A)  
SPECIFICATIONS  
MODEL  
LMA240F-24-Y  
LMA240F-24-HY  
VOLTAGE[V]  
AC85 - 264 1f(Refer to “Derating” ,Instruction Manual 1 and 3)  
ACIN 100V 3.9typ (Io=100%)  
ACIN 200V 1.8typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
ACIN 100V 86.0typ (Io=100%)  
ACIN 200V 88.0typ (Io=100%)  
ACIN 100V 0.99typ (Io=100%)  
ACIN 200V 0.95typ (Io=100%)  
86.0typ (Io=100%)  
88.0typ (Io=100%)  
EFFICIENCY[%]  
INPUT  
POWER FACTOR  
ACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)  
ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.15 / 0.40max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1)  
24  
24  
*2  
Convection 10  
Forced air 12.5  
10 (Peak 20)  
CURRENT[A]  
*2  
12.5 (Peak 20)  
96max  
*7  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
96max  
*7  
150max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
0 to +50C 120max  
-10 - 0C 160max  
0 to +50C 150max  
-10 - 0C 180max  
0 to +50C 240max  
*3  
RIPPLE[mVp-p]  
*3  
OUTPUT  
RIPPLE NOISE[mVp-p]  
TEMPERATURE REGULATION[mV]  
-10 to +50  
C
290max  
96max  
*
4
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]  
350typ (ACIN 100V, Io=100%)  
20typ (ACIN 100V, Io=100%)  
19.20 to 27.50  
*
9
19.20 to 27.50  
24.00 to 24.96  
OUTPUT VOLTAGE SETTING[V]  
24.00 to 24.96  
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically  
OVERVOLTAGE PROTECTION[V] 27.60 to 33.60 27.60 to 33.60  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT RC  
Not provided  
Option (Required external power source.)  
AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) 2MOOP  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) 1MOOP  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)  
.
*6  
INPUT-FG  
ISOLATION  
.
*6  
*6  
*5  
OUTPUT RC-FG  
OUTPUT-RC  
OPERATING TEMP.,HUMID.AND ALTITUDE  
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)  
-10 to +70C, 20 - 90%RH (Non condensing), (Refer to “Derating”, Instruction Manual 3) 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
IMPACT  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis  
196.1m/s (20G), 11ms, once each X, Y and Z axis  
2
AGENCY APPROVALS (AT ONIY AC input) ANSI/AAMI ES60601-1, EN60601-1 3rd, Complies with IEC60601-1-2 4th Ed.  
SAFETY AND  
NOISE  
REGULATIONS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
CASE SIZE/WEIGHT  
COOLING METHOD  
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B  
*8  
Complies with IEC61000-3-2 (Class A)  
84X46X180mm [3.31X1.81X7.09 inches] (WXHXD) / 540g max (with chassis & cover : 860g max)  
OTHERS  
*5  
Convection / Forced air (Refer to “Derating”, Instruction Manual 3)  
*1 Specification is changed at option, refer to Instruction Manual.  
*2 Peak loading for 10sec. And Duty 40% max.  
to KEISOKU-GIKEN: RM103).  
*8 Please contact us about another class.  
*4 Drift is the change in DC output for an eight hour period  
after a half-hour warm-up at 25C, with the input voltage  
held constant at the rated input/output.  
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.  
Parallel operation is not possible.  
( ) means peak current. There is a possibility that an internal device  
is damaged when the specification is exceeded.  
Derating is required when operated with chassis and cover.  
Sound noise may be generated by power supply in case of pulse load.  
*3 This is the value that measured on measuring board with capacitor of *5 Derating is required.  
22mF at 150mm from output terminal.  
*6 Applicable when remote control (optional) is added.  
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent  
*7 Please contact us about dynamic load and input response.  
June 29, 2020  
LMA-6  
LMA240F  
Block diagram  
FUSE  
250V10A×2  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
FG  
Photocoupler  
OPTION  
CURRENT  
SENSING  
RC  
E
EXTERNAL  
SOURCE  
Photocoupler  
Photocoupler  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
FILTER  
CONTROL  
INVERTER  
CONTROL  
INVERTER  
CONTROL  
OVER VOLTAGE  
PROTECTION  
RECTIFIER  
AND  
FILTER  
TRANSFORMER  
DC OUT  
External view  
External size of option is different from standard model.  
Standard type  
Chassis and cover type  
Connector for Remote ON/OFF(Optional)  
0.5  
2-φ4.5  
200  
6
4-M4  
Mounting Hole  
Name plate  
Voltage adjust  
4-φ3.5  
Mounting Hole  
FG  
16.5  
[0.65]  
[0.24]  
[7.87]  
Point C  
1
2
1
1
2
1
CN4  
FG  
FG  
Input(N)  
Input(L)  
5
3
5
3
CN3  
Input(N)  
Input(L)  
CN3  
Output(-)  
Output(-)  
1
1
CN1  
CN1  
7
1
7
1
CN2  
CN2  
Output(+)  
Output(+)  
6
6
0.5  
Point A  
Point B  
89  
4
[0.16]  
212  
[3.5]  
[8.35]  
Mounting Hole  
0.5  
170  
5
f4.5  
0.5  
200  
6
[6.69]180  
[7.09]  
[0.24]  
[0.2]  
[7.87]  
2-M4  
Mounting Hole  
1  
PCB =1.6  
1 Surface mount device  
5 Mounting holes are existing.  
The back side of P.C.B. of the power supply is assembled some  
SMDs.  
Be attention not to bump against the attached area by vibration.  
Use the spacer of 8mm length or more regarding insulation.  
And do not use press-fitting bush.  
Point A, Point B, Point C are thermometry points.
Connector type  
CN4 Option (Mfr:J.S.T)  
<PIN CONNECTION>  
CN1  
CN2  
CN3  
I/O Connector  
Mating connector  
Terminal  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
1123721-1  
1318912-1  
Pin No.  
Input  
AC(L)  
Pin No. Output  
Pin No. Output  
PIN No.  
Contents  
RC(+)  
Chain  
Loose  
Chain  
Loose  
Chain  
Loose  
1
2
3
4
5
1
2
CN1 1-1123724-3 1-1123722-5  
CN2 1-1123723-6 1-1123722-6  
CN3 1-1123723-7 1-1123722-7  
RC(-)  
AC(N)  
1 to 7  
-V  
1 to 6  
+V  
Barrier strip type  
Model B2B-XH-A  
Mating Connector (Terminal)  
XHP-2  
FG  
Keep drawing current per pin below 5A for CN2,CN3.  
(Mfr:Tyco Electronics)  
Tolerance : 1 [ 0.04]  
Weight : 540g max (with chassis & cover : 860g max)  
PCB material : CEM3  
I/O Connector is Mfr. Tyco Electronics  
Option:-J1:VH(J.S.T) connector type.  
BXH-001T-P0.6  
or SXH-001T-P0.6  
Optional chassis and cover material : Electric galvanizing steel board.  
Dimensions in mm, [ ]=inches  
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max  
June 29, 2020  
LMA-7  
LMA-series  
Assembling and Installation Method  
Installation method  
This power supply is manufactured by SMD technology.The stress to P.C.B like twisting or bending causes the defect of the unit, so han-  
¡
dle the unit with care.  
d2  
In case of metal chassis, keep the distance between d1 & d2 for  
to insulate between lead of component and metal chassis, use the  
spacer of 8mm or more between d1. If it is less than d1 & d2, in-  
sert the insulation sheet between power supply and metal chassis.  
¡
CN1  
d1= 8mm min  
d2  
CN1  
d2  
d2  
d2 = 4mm min  
d2  
There is a possibility that it is not possible to cool enough when  
the power supply is used by the sealing up space as showing in  
right figure.Please use it after confi rming the temperature of point  
A and point B of Instruction Manual 3.  
¡
Case  
Power supply  
(A)  
(B)  
CN1  
(C)  
(F) mounting is not possible when unit is with case cover, but if  
need to operate unit by (F) positioning with case cover, tempera-  
ture / load derating is necessary. For more details, please contact  
our sales or engineering departments.  
¡
CN1  
CN1  
(F)  
Standard  
Position  
(D)  
CN1  
(E)  
CN1  
CN1  
Mounting screw  
The mounting screw should be M3. The hatched area shows the allowance of metal parts for mounting.  
¡
LMA100F, LMA150F  
LMA240F  
¿
¿
8
8
8
8
8
8
8
8
8
8
8
CN1  
CN1, TB1  
8
8
8
Unit [mm]  
Unit [mm]  
8
8
8
8
If metallic fittings are used on the component side of the board,ensure there is no contact with surface mounted components.  
¡
¡
*
This product uses SMD technology.Please avoid the PCB installation method which includes the twisting stress or the bending stress.  
Recommendation to electrically connect FG to metal chassis for reducing noise.  
June 29, 2020  
LMA-8  
LMA-series  
Derating  
Derating curve for input voltage  
¿
[%]  
100  
80  
85 90  
[AC V]  
LMA100F Ambient temperature derating curve  
(Reference value)  
LMA150F Ambient temperature derating curve  
(Reference value)  
¿
¿
1(B)mounting  
1(A)mounting  
2(A) ~ (F)  
mounting  
1(D), (F) 1(E)mounting  
mounting  
1(B), (C)  
mounting  
1(C)mounting  
1(D), (E), (F)  
mounting  
1(A)mounting  
2(A) ~ (F)  
mounting  
100  
100  
80  
80  
70  
60  
50  
40  
30  
1
2
Convection  
1
2
Convection  
60  
50  
40  
30  
Forced air  
Forced air  
(0.5m3 / min)  
(0.5m3 / min)  
20  
20  
0
-10  
0
-10  
0
10  
20  
30 35 40 45 50  
60  
70  
0
10  
20  
30  
40  
50  
60  
70  
Ambient temperature [C]  
Ambient temperature [C]  
LMA240F Ambient temperature derating curve  
(Reference value)  
¿
(B)mounting  
1
1(C), (D), (E)mounting  
(F)mounting  
(A)mounting  
1
1
100  
80  
2(A) ~ (F)  
mounting  
1
2
Convection  
60  
50  
40  
30  
20  
Forced air  
(0.5m3 / min)  
0
-10  
0
10  
20  
30 35 40 45 50  
60  
70  
Ambient temperature [C]  
Output power[W]  
Output  
voltage  
1Convection  
2Forced air  
24V  
240.0  
300.0  
¡The operative ambient temperature is different by with / without chassis cover or mounting position.  
Note: In the hatched area, the specification of Ripple, Ripple Noise is different from other area.  
¡Make sure the temperature at point A and point B is less than the temperatures shown in Instruction Manual 3.  
¡The ambient temperature should be measured 5 to 10 cm away from the power supply so that it won’t be influenced by the  
heat from the power supply. Please consult us for more details.  
June 29, 2020  
LMA-9  
LMA-series  
Instruction Manual  
It is neccessary to read the “Instruction Manual” and “Before using our product” before you use our product.  
Instruction Manual https://en.cosel.co.jp/product/powersupply/LMA/  
Before using our product https://en.cosel.co.jp/technical/caution/index.html  
LMA  
NOTICE  
Basic Characteristics Data  
Series/Parallel  
operation availability  
Switching  
frequency  
[kHz]  
Input  
current  
[A]  
Inrush  
current  
protection  
PCB/Pattern  
Model  
Circuit method  
Single Double  
Series  
Parallel  
sided sided operation operation  
Material  
*1  
Active filter  
Forward converter  
Active filter  
60  
130  
60  
LMA100F  
LMA150F  
LMA240F  
1.4  
2.0  
3.9  
Thermistor  
Thermistor  
SCR  
CEM-3  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
CEM-3  
CEM-3  
Forward converter  
Active filter  
130  
60  
Forward converter  
130  
*1 The value of input current is at ACIN 100V and rated load.  
June 29, 2020  
LMA-10  

相关型号:

LMA100F-24-Y

AC/DC CONVERTER 24V
COSEL

LMA1010

16 x 16-bit Multiplier-Accumulator
LOGIC

LMA1010DC

Multiplier Accumulator/Summer, CMOS, CDIP64
LOGIC

LMA1010DC45

Multiplier Accumulator/Summer, 16-Bit, CMOS, CDIP64, SIDE BRAZED, HERMETIC SEALED, DIP-64
LOGIC

LMA1010DC55

Multiplier Accumulator/Summer, 16-Bit, CMOS, CDIP64, SIDE BRAZED, HERMETIC SEALED, DIP-64
LOGIC

LMA1010DC65

Multiplier Accumulator/Summer, 16-Bit, CMOS, CDIP64, SIDE BRAZED, HERMETIC SEALED, DIP-64
LOGIC

LMA1010DM55

Multiplier Accumulator/Summer, 16-Bit, CMOS, CDIP64, SIDE BRAZED, HERMETIC SEALED, DIP-64
LOGIC

LMA1010DM65

Multiplier Accumulator/Summer, 16-Bit, CMOS, CDIP64, SIDE BRAZED, HERMETIC SEALED, DIP-64
LOGIC

LMA1010DM75

Multiplier Accumulator/Summer, 16-Bit, CMOS, CDIP64, SIDE BRAZED, HERMETIC SEALED, DIP-64
LOGIC

LMA1010DMB75

Multiplier Accumulator/Summer, 16-Bit, CMOS, CDIP64, SIDE BRAZED, HERMETIC SEALED, DIP-64
LOGIC

LMA1010DME55

Multiplier/Accumulator
ETC

LMA1010DME65

Multiplier/Accumulator
ETC