MGFW302415 [COSEL]

DC-DC Regulated Power Supply Module,;
MGFW302415
型号: MGFW302415
厂家: COSEL CO., LTD.    COSEL CO., LTD.
描述:

DC-DC Regulated Power Supply Module,

输出元件
文件: 总12页 (文件大小:1538K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ordering information  
DC-DC Converters PCB Mount Type  
MGF W 1R5 24  
12 -O  
6
MGFW1R5  
1
2
3
4
5
1Series name  
2Dual output  
3Output wattage  
4Input voltage  
5Output voltage  
6Optional  
R
MODEL  
MGFW1R52412  
1.56  
MGFW1R52415  
1.50  
MGFW1R54812  
1.56  
MGFW1R54815  
1.50  
MAX OUTPUT WATTAGE[W]  
*1  
VOLTAGE[V]  
CURRENT[A]  
12 or ꢀ24  
0.065  
15 or ꢀ+0  
0.05  
12 or ꢀ24  
0.065  
15 or ꢀ+0  
0.05  
DC OUTPUT  
SPECIFICATIONS  
MODEL  
MGFW1R52412  
MGFW1R52415  
MGFW1R54812  
MGFW1R54815  
VOLTAGE[V]  
DC9 - 36 (Surge voltage 50V, 100ms max)  
DC18 - 76 (Surge voltage 100V, 100ms max)  
*2  
*2  
INPUT  
CURRENT[A]  
0.081typ  
81typ  
0.079typ  
80typ  
0.041typ  
81typ  
0.040typ  
79typ  
EFFICIENCY[%]  
VOLTAGE[V]  
12 (ꢀ24)  
0.065  
15 (ꢀ30)  
0.05  
12 (ꢀ24)  
0.065  
15 (ꢀ30)  
0.05  
CURRENT[A]  
LINE REGULATION[mV]  
60max  
480max  
600max  
75max  
600max  
750max  
150max  
200max  
260max  
390max  
60max  
60max  
75max  
600max  
750max  
150max  
200max  
180max  
290max  
60max  
*3  
480max  
600max  
150max  
200max  
150max  
240max  
48max  
LOAD REGULATION[mV]  
*
4
RIPPLE[mVp-p]  
*5 150max  
*5 200max  
OUTPUT  
RIPPLE NOISE[mVp-p]  
-20 to ꢀ85C 210max  
-40 to ꢀ85C 320max  
TEMPERATURE REGULATION[mV]  
*
6
DRIFT[mV]  
48max  
START-UP TIME[ms]  
30max (Minimum input, Io=100%)  
14.55 - 15.45  
PROTECTION CIRCUIT OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
ISOLATION INPUT-OUTPUT DC1,500V or AC1,000V 1minute, Cutoff current=10mA, DC500V 1,000MWmin (20 15C)  
OUTPUT VOLTAGE SETTING[V] 11.64 - 12.36  
11.64 - 12.36  
14.55 - 15.45  
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to ꢀ85C, 20 to 95%RH (Non condensing) (Required derating), 5,000m (16,400feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -40 to ꢀ100C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz 98.0m/s (10G), 3minute period, 60minutes each along X, Y and Z axis  
2
IMPACT  
490.3m/s (50G) 11ms, once each along X, Y and Z axis  
SAFETY  
OTHERS  
AGENCY APPROVALS  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL, EN60950-1  
17.0X12.0X8.5mm [0.67X0.48X0.34 inches] (WXHXD) / 4g max  
Convection/Forced air  
*1 Single output ꢀ24V, 30V with no use of COM.  
*2 Rated input 24V or 48V DC Io=100%  
*3 Symmetrical loading from 20% to 100%.  
*4 Symmetrical loading from 0% to 100%.  
*5 Ripple and Ripple Noise is measured by using test board with ceramic capacitor 1 F at 50mm from output pins.  
*6 Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.  
*
Parallel operation with other model is not possible.  
MG-38  
MGFW1R5  
External view  
Recommended Pad and Hole dia.  
TOP VIEW)  
Model  
Model  
5-f0.9  
2.2  
[0.09]  
Unit : 0.1inch  
Dimension : mm  
2.54  
[0.1]  
2.8  
[0.11]  
12.7  
[0.5]  
Tolerance 0.5 [ 0.02]  
Dimensions in mm, [ ]= inches  
Pin terminal material : Copper  
Planting treatment of terminal : Lead free plating  
Case material : PBT  
Vin  
Vin  
Vout COM Vout  
Weight 4g max  
0.5  
[0.02]  
17  
[0.67]  
MG-39  
Ordering information  
DC-DC Converters PCB Mount Type  
MGF W  
+
24  
12 -O  
5 6  
MGFW3  
1
2
3
4
1Series name  
2Dual output  
3Output wattage  
4Input voltage  
5Output voltage  
6Optional  
R
MODEL  
MGFW+2412  
+.12  
MGFW+2415  
+.00  
MGFW+4812  
+.12  
MGFW+4815  
+.00  
MAX OUTPUT WATTAGE[W]  
*1  
VOLTAGE[V]  
CURRENT[A]  
12 or ꢀ24  
0.1+  
15 or ꢀ+0  
0.1  
12 or ꢀ24  
0.1+  
15 or ꢀ+0  
0.1  
DC OUTPUT  
SPECIFICATIONS  
MODEL  
MGFW+2412  
MGFW+2415  
MGFW+4812  
MGFW+4815  
DC9 - 36 (Surge voltage 50V,100ms max)  
DC18 - 76 (Surge voltage 100V,100ms max)  
VOLTAGE[V]  
(Refer to the instruction manual for input voltage derating.) (Refer to the instruction manual for input voltage derating.)  
INPUT  
*2  
*2  
CURRENT[A]  
0.16typ  
82typ  
0.16typ  
82typ  
0.081typ  
81typ  
0.078typ  
81typ  
EFFICIENCY[%]  
VOLTAGE[V]  
12 (ꢀ24)  
0.13  
15 (ꢀ30)  
0.1  
12 (ꢀ24)  
0.13  
15 (ꢀ30)  
0.1  
CURRENT[A]  
LINE REGULATION[mV]  
60max  
480max  
600max  
75max  
600max  
750max  
150max  
200max  
220max  
340max  
60max  
60max  
480max  
600max  
150max  
200max  
180max  
290max  
48max  
75max  
600max  
750max  
150max  
200max  
220max  
340max  
60max  
*3  
LOAD REGULATION[mV]  
*
4
RIPPLE[mVp-p]  
*5 150max  
*5 200max  
OUTPUT  
RIPPLE NOISE[mVp-p]  
-20 to ꢀ70C 180max  
-40 to ꢀ70C 290max  
TEMPERATURE REGULATION[mV]  
*
6
DRIFT[mV]  
48max  
START-UP TIME[ms]  
30max (Minimum input, Io=100%)  
14.55 - 15.45  
PROTECTION CIRCUIT OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
ISOLATION INPUT-OUTPUT DC1,500V or AC1,000V 1minute, Cutoff current=10mA, DC500V 1,000MWmin (20 15C)  
OUTPUT VOLTAGE SETTING[V] 11.64 - 12.36  
11.64 - 12.36  
14.55 - 15.45  
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to ꢀ85C, 20 to 95%RH (Non condensing) (Required derating), 5,000m (16,400feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -40 to ꢀ100C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz 98.0m/s (10G), 3minute period, 60minutes each along X, Y and Z axis  
2
IMPACT  
490.3m/s (50G) 11ms, once each along X, Y and Z axis  
SAFETY  
OTHERS  
AGENCY APPROVALS  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL, EN60950-1  
17.0X12.0X8.5mm [0.67X0.48X0.34 inches] (WXHXD) / 4g max  
Convection/Forced air  
*1 Single output ꢀ24V, 30V with no use of COM.  
*2 Rated input 24V or 48V DC Io=100%  
*3 Symmetrical loading from 20% to 100%.  
*4 Symmetrical loading from 0% to 100%.  
*5 Ripple and Ripple Noise is measured by using test board with ceramic capacitor 1 F at 50mm from output pins.  
*6 Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.  
*
Parallel operation with other model is not possible.  
MG-40  
MGFW3  
External view  
Recommended Pad and Hole dia.  
TOP VIEW)  
Model  
Model  
5-f0.9  
2.2  
[0.09]  
Unit : 0.1inch  
Dimension : mm  
2.54  
[0.1]  
2.8  
[0.11]  
12.7  
[0.5]  
Tolerance 0.5 [ 0.02]  
Dimensions in mm, [ ]= inches  
Pin terminal material : Copper  
Planting treatment of terminal : Lead free plating  
Case material : PBT  
Vin  
Vin  
Vout COM Vout  
Weight 4g max  
0.5  
[0.02]  
17  
[0.67]  
MG-41  
Ordering information  
DC-DC Converters PCB Mount Type  
MGF W  
6
24  
12 -O  
5 6  
MGFW6  
1
2
3
4
1Series name  
2Dual output  
R
3Output wattage  
4Input voltage  
5Output voltage  
6Optional  
Y2: Output voltage  
adjustable (ꢀ10%, -5%)  
MODEL  
MGFW62412  
6.00  
MGFW62415  
6.00  
MGFW64812  
6.00  
MGFW64815  
6.00  
MAX OUTPUT WATTAGE[W]  
*1  
VOLTAGE[V]  
CURRENT[A]  
12 or ꢀ24  
0.25  
15 or ꢀ+0  
0.2  
12 or ꢀ24  
0.25  
15 or ꢀ+0  
0.2  
DC OUTPUT  
SPECIFICATIONS  
MODEL  
MGFW62412  
MGFW62415  
MGFW64812  
MGFW64815  
VOLTAGE[V]  
DC9 - 36 (Surge voltage 50V,100ms max)  
DC18 - 76 (Surge voltage 100V,100ms max)  
*2  
*2  
INPUT  
CURRENT[A]  
0.29typ  
87typ  
0.29typ  
88typ  
0.15typ  
88typ  
0.15typ  
88typ  
EFFICIENCY[%]  
VOLTAGE[V]  
12 (ꢀ24)  
0.25  
15 (ꢀ30)  
0.2  
12 (ꢀ24)  
0.25  
15 (ꢀ30)  
0.2  
CURRENT[A]  
LINE REGULATION[mV]  
60max  
480max  
600max  
120max  
75max  
600max  
750max  
120max  
360max  
200max  
500max  
230max  
360max  
60max  
60max  
480max  
600max  
120max  
360max  
200max  
500max  
190max  
300max  
48max  
75max  
600max  
750max  
120max  
360max  
200max  
500max  
230max  
360max  
60max  
*3  
LOAD REGULATION[mV]  
*
4
Po=+0% -  
RIPPLE[mVp-p]  
*5  
*5  
Po=0 - +0% 360max  
OUTPUT  
Po=+0% -  
200max  
RIPPLE NOISE[mVp-p]  
Po=0 - +0% 500max  
-20 to ꢀ75C 190max  
-40 to ꢀ75C 300max  
TEMPERATURE  
REGULATION[mV]  
*
6
DRIFT[mV]  
48max  
30max (Minimum input, Io=100%)  
11.64 - 12.36 14.55 - 15.45  
START-UP TIME[ms]  
OUTPUT VOLTAGE SETTING[V]  
11.64 - 12.36  
14.55 - 15.45  
PROTECTION  
CIRCUIT AND  
OTHERS  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
REMOTE ON/OFF Provided (Negative logic L : ON, H : OFF)  
DC1,500V or AC1,000V 1minute, Cutoff current=10mA, DC500V 1,000MWmin (20 15C)  
ISOLATION INPUT-OUTPUT  
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to ꢀ85C, 20 to 95%RH (Non condensing) (Required derating), 5,000m (16,400feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -40 to ꢀ100C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz 98.0m/s (10G), 3minute period, 60minutes each along X, Y and Z axis  
2
IMPACT  
490.3m/s (50G) 11ms, once each along X, Y and Z axis  
SAFETY  
OTHERS  
AGENCY APPROVALS  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL, EN60950-1  
22.0X12.0X9.5mm [0.87X0.48X0.38 inches] (WXHXD) / 7g max  
Convection/Forced air  
*1 Single output ꢀ24V, 30V with no use of COM.  
*2 Rated input 5V, 12V, 24V or 48V DC Io=100%  
*3 Symmetrical loading from 20% to 100%.  
*4 Symmetrical loading from 0% to 100%.  
*5 Ripple and Ripple Noise is measured by using test board with ceramic capacitor 1 F at 50mm from output pins. Po:Output wattage.  
*6 Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.  
*
Parallel operation with other model is not possible.  
MG-42  
MGFW6  
External view  
Recommended Pad and Hole dia.  
Model  
Model  
(TOP VIEW)  
7-f0.9  
2.11  
[0.09]  
Unit : 0.1inch  
Dimension : mm  
2.54  
[0.1]  
2.8  
[0.11]  
17.78  
[0.7]  
Tolerance 0.5 [ 0.02]  
Dimensions in mm, [ ]= inches  
Pin terminal material : Copper  
Planting treatment of terminal : Lead free plating  
Case material : PBT  
Vin  
Vin RC  
NC  
Vout COM  
0.5  
Vout  
Weight 7g max  
[0.02]  
22  
[0.87]  
<Pin Configuration (Option :Y2)>  
2.11  
[0.09]  
2.54  
[0.1]  
17.78  
[0.7]  
Vin  
Vin RC  
TRM  
Vout COM  
0.5  
Vout  
[0.02]  
22  
[0.87]  
MG-43  
Ordering information  
DC-DC Converters PCB Mount Type  
MGF W  
10  
24  
12 -O  
5 6  
MGFW10  
1
2
3
4
1Series name  
2Dual output  
R
3Output wattage  
4Input voltage  
5Output voltage  
6Optional  
Y2: Output voltage  
adjustable (ꢀ10%, -5%)  
MODEL  
MGFW102412  
10.08  
MGFW102415  
MGFW104812  
10.08  
MGFW104815  
10.20  
MAX OUTPUT WATTAGE[W]  
10.20  
*1  
VOLTAGE[V]  
CURRENT[A]  
12 or ꢀ24  
0.42  
15 or ꢀ+0  
0.+4  
12 or ꢀ24  
0.42  
15 or ꢀ+0  
0.+4  
DC OUTPUT  
SPECIFICATIONS  
MODEL  
MGFW102412  
MGFW102415  
MGFW104812  
MGFW104815  
DC9 - 36 (Surge voltage 50V,100ms max)  
DC18 - 76 (Surge voltage 100V,100ms max)  
VOLTAGE[V]  
(Refer to the instruction manual for input voltage derating.) (Refer to the instruction manual for input voltage derating.)  
INPUT  
*2  
*2  
CURRENT[A]  
0.49typ  
87typ  
0.49typ  
87typ  
0.25typ  
87typ  
0.25typ  
88typ  
EFFICIENCY[%]  
VOLTAGE[V]  
12 (ꢀ24)  
0.42  
15 (ꢀ30)  
0.34  
12 (ꢀ24)  
0.42  
15 (ꢀ30)  
0.34  
CURRENT[A]  
LINE REGULATION[mV]  
60max  
480max  
600max  
120max  
75max  
600max  
750max  
120max  
360max  
200max  
500max  
180max  
290max  
60max  
60max  
480max  
600max  
120max  
360max  
200max  
500max  
150max  
240max  
48max  
75max  
600max  
750max  
120max  
360max  
200max  
500max  
180max  
290max  
60max  
*3  
LOAD REGULATION[mV]  
*
4
Po=+0% -  
RIPPLE[mVp-p]  
*5  
Po=0 - +0% 360max  
OUTPUT  
Po=+0% -  
200max  
RIPPLE NOISE[mVp-p]  
*5  
Po=0 - +0% 500max  
-20 to ꢀ50C 150max  
-40 to ꢀ50C 240max  
TEMPERATURE  
REGULATION[mV]  
*
6
DRIFT[mV]  
48max  
30max (Minimum input, Io=100%)  
11.64 - 12.36 14.55 - 15.45  
START-UP TIME[ms]  
OUTPUT VOLTAGE SETTING[V]  
11.64 - 12.36  
14.55 - 15.45  
PROTECTION  
CIRCUIT AND  
OTHERS  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
REMOTE ON/OFF Provided (Negative logic L : ON, H : OFF)  
DC1,500V or AC1,000V 1minute, Cutoff current=10mA, DC500V 1,000MWmin (20 15C)  
ISOLATION INPUT-OUTPUT  
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to ꢀ85C, 20 to 95%RH (Non condensing) (Required derating), 5,000m (16,400feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -40 to ꢀ100C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz 98.0m/s (10G), 3minute period, 60minutes each along X, Y and Z axis  
2
IMPACT  
490.3m/s (50G) 11ms, once each along X, Y and Z axis  
SAFETY  
OTHERS  
AGENCY APPROVALS  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL, EN60950-1  
22.0×12.0×9.5mm [0.87×0.48×0.38 inches] (WXHXD) / 7g max  
Convection/Forced air  
*1 Single output ꢀ24V, 30V with no use of COM.  
*2 Rated input 5V, 12V, 24V or 48V DC Io=100%  
*3 Symmetrical loading from 20% to 100%.  
*4 Symmetrical loading from 0% to 100%.  
*5 Ripple and Ripple Noise is measured by using test board with ceramic capacitor 1 F at 50mm from output pins. Po:Output wattage.  
*6 Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.  
*
Parallel operation with other model is not possible.  
MG-44  
MGFW10  
External view  
Recommended Pad and Hole dia.  
Model  
Model  
(TOP VIEW)  
7-f0.9  
2.11  
[0.09]  
2.54  
[0.1]  
Unit : 0.1inch  
Dimension : mm  
2.8  
[0.11]  
17.78  
[0.7]  
Tolerance 0.5 [ 0.02]  
Dimensions in mm, [ ]= inches  
Pin terminal material : Copper  
Planting treatment of terminal : Lead free plating  
Case material : PBT  
Vin  
Vin RC  
NC  
Vout COM  
0.5  
Vout  
Weight 7g max  
[0.02]  
22  
[0.87]  
<Pin Configuration (Option :Y2)>  
2.11  
[0.09]  
2.54  
[0.1]  
17.78  
[0.7]  
Vin  
Vin RC  
TRM  
Vout COM  
0.5  
Vout  
[0.02]  
22  
[0.87]  
MG-45  
Ordering information  
DC-DC Converters PCB Mount Type  
MGF W  
15  
24  
05 -O  
5 6  
MGFW15  
1
2
3
4
1Series name  
2Dual output  
3Output wattage  
4Input voltage  
R
5Output voltage  
6Optional  
G: Capacitor between  
Input and Output is removed.  
R: with Remote ON/OFF  
(
Positive logic control)  
MODEL  
MGFW152405  
MGFW152412  
15.6  
12 or ꢀ24  
MGFW152415  
15  
15 or ꢀ+0  
MGFW154805  
MGFW154812  
15.6  
MGFW154815  
MAX OUTPUT WATTAGE[W]  
15  
15  
15  
*1  
VOLTAGE[V]  
CURRENT[A]  
5 or ꢀ10  
1.5  
5 or ꢀ10  
1.5  
12 or ꢀ24  
0.65  
15 or ꢀ+0  
0.5  
DC OUTPUT  
0.65  
0.5  
SPECIFICATIONS  
MODEL  
MGFW152405  
DC9 - 36  
0.74typ  
84typ  
MGFW152412  
MGFW152415  
MGFW154805  
DC18 - 76  
0.37typ  
84typ  
MGFW154812  
MGFW154815  
VOLTAGE[V]  
*2  
*2  
INPUT  
CURRENT[A]  
0.74typ  
88typ  
0.70typ  
89typ  
0.37typ  
87typ  
0.36typ  
88typ  
EFFICIENCY[%]  
VOLTAGE[V]  
5(ꢀ10)  
12(ꢀ24)  
0.65  
15(ꢀ30)  
0.5  
5(ꢀ10)  
12(ꢀ24)  
0.65  
15(ꢀ30)  
0.5  
CURRENT[A]  
1.5  
1.5  
LINE REGULATION[mV]  
40max  
500max *5  
60max  
600max  
480max  
100max  
120max  
100max  
150max  
150max  
240max  
50max  
75max  
750max  
600max  
100max  
120max  
100max  
150max  
180max  
290max  
60max  
40max  
60max  
600max  
480max  
100max  
120max  
100max  
150max  
150max  
240max  
50max  
75max  
750max  
600max  
100max  
120max  
100max  
150max  
180max  
290max  
60max  
500max *5  
250max  
100max  
120max  
100max  
150max  
50max  
*3  
*4  
LOAD REGULATION[mV]  
250max  
-20 to ꢀ60C 100max  
-40 to -20C 120max  
-20 to ꢀ60C 100max  
-40 to -20C 150max  
-20 to ꢀ60C 50max  
-40 to ꢀ60C 80max  
RIPPLE[mVp-p]  
*6  
*6  
OUTPUT  
RIPPLE NOISE[mVp-p]  
TEMPERATURE REGULATION[mV]  
80max  
*7  
DRIFT[mV]  
50max  
50max  
START-UP TIME[ms]  
30max (Minimum input, Io=100%)  
11.765 - 12.492  
OUTPUT VOLTAGE SETTING[V]*8 4.935 - 5.240  
14.602 - 15.505  
4.935 - 5.240  
11.765 - 12.492  
14.602 - 15.505  
PROTECTION  
CIRCUIT AND  
OTHERS  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
REMOTE ON/OFF  
INPUT-OUTPUT  
Provided (Negative logic L:ON, H:OFF)  
DC1,500V 1minute, Cutoff current = 10mA, DC500V 1,000MWmin (20 15C)  
DC1,000V 1minute, Cutoff current = 10mA, DC500V 1,000MWmin (20 15C)  
DC1,000V 1minute, Cutoff current = 10mA, DC500V 1,000MWmin (20 15C)  
ISOLATION INPUT-CASE  
OUTPUT-CASE  
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to ꢀ85C, 20 to 95%RH (Non condensing) (Required Derating), 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -40 to ꢀ100C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 98.0m/s (10G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
490.3m/s (50G), 11ms, once each along X, Y and Z axis  
SAFETY  
OTHERS  
AGENCY APPROVALS  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL, EN60950-1  
25.4X9.9X25.4mm [1X0.39X1 inches] (WXHXD) / 20g max  
Convection/Forced air  
*1 Single output ꢀ10V, 24V, 30V with no use of COM.  
*2 Rated input 12V, 24V or 48V DC lo=100%  
*8 Rated input voltage (DC24V, DC48V), rated output wattage, ambient temperature at 25C.  
Parallel operation with other model is not possible.  
*
*3 Symmetrical loading from 5% to 100%.  
*4 Symmetrical loading from 20% to 100%.  
*5 Refer to the instruction manual 11.  
*6 Ripple and Ripple Noise is measured by using test board with ceramic capacitor 22 F at  
50mm from output pins. (20MHz Osilloscope)  
*7 Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.  
MG-46  
MGFW15  
External view  
Name Plate  
Recommended Pad and Hole dia.  
(TOP VIEW)  
6-f1.5  
Case  
Bottom Cover  
0.1  
f1  
Unit : 0.1inch  
Dimension : mm  
Tolerance 0.5 [ 0.02]  
Dimensions in mm, [ ]=inches  
Pin terminal material : Copper  
Plating treatment of terminal : Lead free plating  
Case material : Brass  
Plating treatment of case : Nickel plating  
Bottom Cover : FR4 (t=0.6) [t=0.024]  
Please keep enough creepage distance with the  
pattern on PCB and other components.  
Weight 20g max  
+Vout  
COM  
-Vout  
+
-
Vin  
Vin  
RC  
20.32  
[0.8]  
25.4  
[1.0]  
MG-47  
Ordering information  
DC-DC Converters PCB Mount Type  
MGF W  
+0  
24  
05 -O  
5 6  
MGFW30  
1
2
3
4
1Series name  
2Dual output  
3Output wattage  
4Input voltage  
R
5Output voltage  
6Optional  
G: Capacitor between  
Input and Output is removed.  
R: with Remote ON/OFF  
(
Positive logic control)  
MODEL  
MGFW+02405  
MGFW+02412  
+0  
12 or ꢀ24  
MGFW+02415  
+0  
15 or ꢀ+0  
MGFW+04805  
MGFW+04812  
+0  
MGFW+04815  
MAX OUTPUT WATTAGE[W]  
20  
20  
+0  
*1  
VOLTAGE[V]  
CURRENT[A]  
5 or ꢀ10  
2
5 or ꢀ10  
2
12 or ꢀ24  
1.25  
15 or ꢀ+0  
1
DC OUTPUT  
1.25  
1
SPECIFICATIONS  
MODEL  
MGFW+02405  
DC9 - 36  
0.98typ  
85typ  
MGFW+02412  
MGFW+02415  
MGFW+04805  
DC18 - 76  
0.49typ  
85typ  
MGFW+04812  
MGFW+04815  
VOLTAGE[V]  
*2  
*2  
INPUT  
CURRENT[A]  
1.42typ  
88typ  
1.44typ  
87typ  
0.71typ  
88typ  
0.72typ  
87typ  
EFFICIENCY[%]  
VOLTAGE[V]  
5(ꢀ10)  
12(ꢀ24)  
1.25  
15(ꢀ30)  
1
5(ꢀ10)  
12(ꢀ24)  
1.25  
15(ꢀ30)  
1
CURRENT[A]  
2
2
LINE REGULATION[mV]  
40max  
500max *5  
60max  
600max  
480max  
100max  
120max  
100max  
150max  
150max  
240max  
50max  
75max  
750max  
600max  
100max  
120max  
100max  
150max  
180max  
290max  
60max  
40max  
60max  
600max  
480max  
100max  
120max  
100max  
150max  
150max  
240max  
50max  
75max  
750max  
600max  
100max  
120max  
100max  
150max  
180max  
290max  
60max  
500max *5  
250max  
100max  
120max  
100max  
150max  
50max  
*3  
*4  
LOAD REGULATION[mV]  
250max  
-20 to ꢀ60C 100max  
-40 to -20C 120max  
-20 to ꢀ60C 100max  
-40 to -20C 150max  
-20 to ꢀ60C 50max  
-40 to ꢀ60C 80max  
RIPPLE[mVp-p]  
*6  
*6  
OUTPUT  
RIPPLE NOISE[mVp-p]  
TEMPERATURE REGULATION[mV]  
80max  
*7  
DRIFT[mV]  
50max  
50max  
START-UP TIME[ms]  
30max (Minimum input, Io=100%)  
11.765 - 12.492  
OUTPUT VOLTAGE SETTING[V]*8 4.935 - 5.240  
14.602 - 15.505  
4.935 - 5.240  
11.765 - 12.492  
14.602 - 15.505  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
PROTECTION  
CIRCUIT AND OVERVOLTAGE PROTECTION[V] Works over 120 to 160% of rating (Total of ꢀV and -V)  
OTHERS  
REMOTE ON/OFF  
INPUT-OUTPUT  
Provided (Negative logic L:ON, H:OFF)  
DC1,500V 1minute, Cutoff current = 10mA, DC500V 1,000MWmin (20 15C)  
DC1,000V 1minute, Cutoff current = 10mA, DC500V 1,000MWmin (20 15C)  
DC1,000V 1minute, Cutoff current = 10mA, DC500V 1,000MWmin (20 15C)  
ISOLATION INPUT-CASE  
OUTPUT-CASE  
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to ꢀ85C, 20 to 95%RH (Non condensing) (Required Derating), 3,000m (10,000feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -40 to ꢀ100C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 98.0m/s (10G), 3minutes period, 60minutes each along X, Y and Z axis  
2
IMPACT  
490.3m/s (50G), 11ms, once each along X, Y and Z axis  
SAFETY  
OTHERS  
AGENCY APPROVALS  
CASE SIZE/WEIGHT  
COOLING METHOD  
UL60950-1, C-UL, EN60950-1  
25.4X9.9X50.8mm [1X0.39X2 inches] (WXHXD) / 40g max  
Convection/Forced air  
*1 Single output ꢀ10V, 24V, 30V with no use of COM.  
*2 Rated input 12V, 24V or 48V DC lo=100%  
*7 Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.  
*8 Rated input voltage (DC24V, DC48V), rated output wattage, ambient temperature at 25C.  
*3 Symmetrical loading from 5% to 100%.  
*
Parallel operation with other model is not possible.  
*4 Symmetrical loading from 20% to 100%.  
*5 Refer to the instruction manual 11.  
*6 Ripple and Ripple Noise is measured by using test board with ceramic capacitor 22 F at  
50mm from output pins. (20MHz Osilloscope)  
MG-48  
MGFW30  
External view  
Name Plate  
Recommended Pad and Hole dia.  
(TOP VIEW)  
6-f1.5  
Case  
Bottom Cover  
0.1  
f1  
Unit : 0.1inch  
Dimension : mm  
Tolerance 0.5 [ 0.02]  
Dimensions in mm, [ ]=inches  
Pin terminal material : Copper  
Plating treatment of terminal : Lead free plating  
Case material : Brass  
+Vout  
COM  
+Vin  
-Vin  
Plating treatment of case : Nickel plating  
Bottom Cover : FR4 (t=0.6) [t=0.024]  
Please keep enough creepage distance with the  
pattern on PCB and other components.  
Weight 40g max  
RC  
-Vout  
45.72  
[1.8]  
50.8  
[2.0]  
MG-49  

相关型号:

MGFW302415-R

DC-DC Regulated Power Supply Module
COSEL

MGFW304812

DC-DC Regulated Power Supply Module,
COSEL

MGFX35V0005

RF Power Field-Effect Transistor, X Band, Gallium Arsenide, N-Channel, Junction FET, HERMETIC SEALED PACKAGE-2
MITSUBISHI

MGFX35V0510

RF Power Field-Effect Transistor, X Band, Gallium Arsenide, N-Channel, Junction FET, HERMETIC SEALED PACKAGE-2
MITSUBISHI

MGFX35V0510-01

RF Power Field-Effect Transistor, 1-Element, X Band, Gallium Arsenide, N-Channel, Junction FET, HERMETIC SEALED, METAL CERAMIC, GF-14, 2 PIN
MITSUBISHI

MGFX35V0510-51

RF Power Field-Effect Transistor, 1-Element, X Band, Gallium Arsenide, N-Channel, Junction FET
MITSUBISHI

MGFX35V1722

RF Power Field-Effect Transistor, KU Band, Gallium Arsenide, N-Channel, Junction FET, HERMETIC SEALED PACKAGE-2
MITSUBISHI

MGFX35V1722-01

RF Power Field-Effect Transistor, 1-Element, KU Band, Gallium Arsenide, N-Channel, Junction FET, HERMETIC SEALED, METAL CERAMIC, GF-14, 2 PIN
MITSUBISHI

MGFX35V9095

RF Power Field-Effect Transistor, X Band, Gallium Arsenide, N-Channel, Junction FET, HERMETIC SEALED PACKAGE-2
MITSUBISHI

MGFX35V9095-01

RF Power Field-Effect Transistor, 1-Element, X Band, Gallium Arsenide, N-Channel, Junction FET, HERMETIC SEALED, METAL CERAMIC, GF-14, 2 PIN
MITSUBISHI

MGFX35V9095-51

RF Power Field-Effect Transistor, 1-Element, X Band, Gallium Arsenide, N-Channel, Junction FET
MITSUBISHI

MGFX35V9500

RF Power Field-Effect Transistor, X Band, Gallium Arsenide, N-Channel, Junction FET, HERMETIC SEALED PACKAGE-2
MITSUBISHI