NBM-20-331 [COSEL]

Single Phase EMI Filter, 250V, 60HzHz, ROHS COMPLIANT PACKAGE;
NBM-20-331
型号: NBM-20-331
厂家: COSEL CO., LTD.    COSEL CO., LTD.
描述:

Single Phase EMI Filter, 250V, 60HzHz, ROHS COMPLIANT PACKAGE

LTE
文件: 总2页 (文件大小:390K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ordering information  
Low leakage current type,Withstand voltage 4,000VAC (2-stage filter)  
NBM -10 -471 -O  
NBM series  
1
2
3
4
1Model Name  
2Rated Current  
3Line to ground capacitor code:See table 1.1.  
R
table1.1 Line to ground capacitor code  
Line to ground  
capacitor  
(nominal value)  
Not Provided  
Leakage Current  
(Input 125/250V 60Hz)  
Code  
000  
101  
221  
331  
471  
5
A/ 10 A max  
12.5 A/ 25 A max  
25 A/ 50 A max  
37.5 A/ 75 A max  
50  
A/100 A max  
100pF  
220pF  
330pF  
470pF  
When the line to ground capacitor code is  
different, the attenuation characteristic is  
different.  
*
4Options  
D:DIN rail installation type  
DIN rail installation type is option  
The terminal cover is retracted inside the unit  
The dimensions change when the option is set.  
Refer to External view.  
*
Features of NBM series  
Low leakage current type, Withstand voltage 4,000VAC (2-stage filter)  
-Single Phase 250 VAC  
-Push down type terminal block  
Specifications  
No.  
Items  
NBM-06-471  
NBM-10-471  
NBM-16-471  
NBM-20-471  
NBM-30-471  
1
Rated Voltage[V]  
AC 1f250 / DC250  
2
Rated Current[A]  
6
10  
16  
20  
30  
3
Test Voltage (Terminal-Mounting Plate)  
4,000 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity  
4
Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100MWmin at room temperature and humidity  
5
Leakage current 125/250V 60Hz  
Voltage drop  
50 A/100 A max  
6
1.0V max  
7
Safety agency approval temperatures  
Operating temperature  
Operating humidity  
-25 to +85C(Refer to Derating Curve)  
-40 to +85C(Refer to Derating Curve)  
20 to 95%RH (Non condensing)  
-40 to +85C/20 to 95%RH (Non condensing)  
8
9
10  
11  
12  
13  
14  
Storage temperature/humidity  
Vibration  
2
10 to 55Hz, 19.6m/s (2G), 3min. Period, 1hour each X, Y and Z axis  
2
Impact  
196.1m/s (20G), 11ms Once each X, Y and Z axis  
Safety agency approvals  
Case size (without projection) /Weight  
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)  
53X41X92 mm [2.09X1.61X3.62 inches] (WXHXD) /270g max (Option : -D refer to external view)  
Circuit Diagram  
Derating Curve  
Case  
100  
80  
60  
40  
20  
0
3
1
CY  
LOAD  
LINE  
CY  
2
4
-40  
-30  
-20  
40  
50 55 60  
70  
80  
90  
Ambient Temperature [C]  
CY : Line to ground capacitor  
: Mounting Plate  
NB-4  
NBC,NBM series  
External view  
As this product is adopted push-down type terminal block, this appearance is as follows.  
1The terminal cover is retracted inside the unit.  
2The screws for connecting the terminals are held in the up right position.  
Standard Type  
92  
[3.62]  
2.5  
[0.1]  
30.5  
[1.2]  
0.5  
[3.23]  
82  
2-f4.8  
2-Protection Earth  
8
[0.31]  
80  
[0.19]  
[3.15]  
Mounting Hole  
Input  
Terminal  
Output  
Name Plate  
Terminal  
Output  
Input  
Terminal  
Terminal  
6-M4  
Mounting Plate  
Terminal cover  
Terminal cover  
Closed the terminal cover  
Tolerance : 1 [ 0.04]  
Weight : 270g max  
Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04]  
Case : PBT  
Dimensions in mm, [ ]=inches  
Terminal block screw tightening torque M4:1.6N-m (16.9kgf-cm) max  
DIN rail installation Type  
2.5  
[0.1]  
30.5  
[1.2]  
92  
[3.62]  
80  
1.5  
[0.32]  
2-Protection Earth  
8.2  
8
[0.31]  
[3.15]  
Input  
Terminal  
Output  
Name Plate  
Terminal  
Output  
Input  
Terminal  
Terminal  
6-M4  
Terminal cover  
Mounting Plate  
Terminal cover  
Closed the terminal cover  
Tolerance : 1 [ 0.04]  
Weight : 270g max  
Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04]  
Case : PBT  
Dimensions in mm, [ ]=inches  
Terminal block screw tightening torque M4:1.6N-m (16.9kgf-cm) max  
DIN rail  
Note when installing the EMI/EMC  
¡
Filter on a DIN rail.  
DIN rail  
When the EMI/EMC Filter is grounded through  
the DIN rail, the proper noise attenuation may not  
be achieved.  
Name Plate  
Be sure to connect the protection earth (PE) of  
the EMI/EMC Filter body to the earth.  
It can connect the ground to either one only.  
NB-5  

相关型号:

NBM-20-331-D

LINE FILTER 250VDC/VAC 20A DIN
COSEL

NBM-20-471

LINE FILTER 250VDC/VAC 20A CHAS
COSEL

NBM-20-471-D

LINE FILTER 250VDC/VAC 20A DIN
COSEL

NBM-30-000

LINE FILTER 250VDC/VAC 30A CHAS
COSEL

NBM-30-101

LINE FILTER 250VDC/VAC 30A CHAS
COSEL

NBM-30-221

LINE FILTER 250VDC/VAC 30A CHAS
COSEL

NBM-30-331

LINE FILTER 250VDC/VAC 30A CHAS
COSEL

NBM-30-331-D

LINE FILTER 250VDC/VAC 30A DIN
COSEL

NBM-30-471

LINE FILTER 250VDC/VAC 30A CHAS
COSEL

NBM-30-471-D

LINE FILTER 250VDC/VAC 30A DIN
COSEL

NBM3814B46C15A6C00

Non-Isolated, Fixed-Ratio DC-DC Converter
VICOR

NBM3814B46C15A6C04

Non-Isolated, Fixed-Ratio DC-DC Converter
VICOR