PBA300F-3R3-C 概述
AC-DC Regulated Power Supply Module, 198W 电源模块
PBA300F-3R3-C 规格参数
生命周期: | Active | 包装说明: | , |
Reach Compliance Code: | unknown | 风险等级: | 5.75 |
其他特性: | REMOTE SHUTDOWN | 模拟集成电路 - 其他类型: | AC-DC REGULATED POWER SUPPLY MODULE |
认证: | CE, TUV, UL | 效率(主输出): | 68% |
高度: | 42 mm | 最大输入电压: | 264 V |
最小输入电压: | 85 V | 长度: | 170 mm |
最高工作温度: | 71 °C | 最低工作温度: | -20 °C |
最大输出电流: | 60 A | 标称输出电压: | 3.3 V |
保护: | OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE | 子类别: | Power Supply Modules |
最大总功率输出: | 198 W | 宽度: | 102 mm |
Base Number Matches: | 1 |
PBA300F-3R3-C 数据手册
通过下载PBA300F-3R3-C数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Ordering information
AC-DC Power Supplies Enclosed Type
PBA/PBW
PB
A
300
F
-5
-O
6
PBA300F
1
2
3
4
5
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *5
Recommended EMI/EMC Filter
NAC-06-472
R
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F3 :Reverse air exhaust
type
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
F4 :Low speed fan
N1 :with DIN rail
Refer to instruction manual
7.1.
MODEL
PBA300F-3R3 PBA300F-5
PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48
MAX OUTPUT WATTAGE[W]
198
300
300
324
330
336
324
336
ACIN 100V 3.3V 60A
5V 60A
5V 60A
7.5V 40A
7.5V 40A
12V 27A
12V 27A
15V 22A
15V 22A
24V 14A
( )
24V 14 16.5 A 36V 9A
36V 9A
48V 7A
48V 7A
DC OUTPUT
3
*
ACIN 200V
3.3V 60A
SPECIFICATIONS
MODEL
PBA300F-3R3 PBA300F-5
PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48
(
)
4
VOLTAGE[V]
AC85 - 264 1 or DC120 - 350 AC50 or DC70 Please refer to the instruction manual 7. option
f
*
ACIN 100V 3typ
4.1typ
2typ
CURRENT[A]
ACIN 200V 1.6typ
( )
50/60 47 - 63
FREQUENCY[Hz]
ACIN 100V 68typ
ACIN 200V 71typ
74typ
77typ
76typ
79typ
78typ
81typ
78typ
81typ
79typ
82typ
81typ
84typ
79typ
82typ
EFFICIENCY[%]
INPUT
(
(
)
)
ACIN 100V 0.98typ Io=100%
POWER FACTOR
ACIN 200V 0.95typ Io=100%
(
(
) (
) (
) (
) (
)
)
ACIN 100V 20/40typ Io=100% Primary inrush current /Secondary inrush current More then 3 sec. to re-start
INRUSH CURRENT[A]
ACIN 200V 40/40typ Io=100% Primary inrush current /Secondary inrush current More then 3 sec. to re-start
(
,
,
,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.45/0.75max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1 DENAN
3.3
5
7.5
12
15
24
14
14 16.5
36
48
ACIN 100V 60
60
40
27
22
9
7
CURRENT[A]
3
*
(
)
ACIN 200V
60
60
40
27
22
9
7
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
80max
140max
120max
160max
40max
60max
12max
20max
40max
80max
140max
120max
160max
50max
75max
20max
36max
60max
120max
160max
150max
180max
75max
120max
30max
48max
100max
120max
160max
150max
180max
120max
180max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
144max
150max
150max
160max
200max
240max
360max
440max
144max
192max
300max
150max
400max
200max
500max
480max
600max
192max
150max
120max
160max
150max
180max
240max
290max
96max
1
1
1
1
0 to +50
*
*
*
*
C
RIPPLE[mVp-p]
-20 - 0
C
0 to +50
C
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
-20 - 0
C
0 to +50
C
-20 to +50
C
2
*
DRIFT[mV]
(
(
,
)
300typ ACIN 100/200V Io=100%
*
START-UP TIME[ms]
HOLD-UP TIME[ms]
Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
,
)
20typ ACIN 100/200V Io=100%
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40
3.96 - 6.00
5.00 - 5.15
5.25 - 8.25
7.50 - 7.80
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V] 4.3 - 6.3 6.5 - 8.0 9.0 - 11.6 14.4 - 18.6 18.0 - 23.3 28.8 - 37.2
43.2 - 54.0
57.6 - 80.0
PROTECTION
(
)
CIRCUIT AND OPERATING INDICATION
LED Green
OTHERS
REMOTE SENSING
REMOTE ON/OFF
Provided
Provided
, , , (
AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
INPUT-OUTPUT RC
INPUT-FG
-
, , , (
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
ISOLATION
,
,
(
)
OUTPUT RC AUX-FG
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
-
-
W
,
,
(
)
OUTPUT-RC AUX
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
-
W
,
(
),
(
)
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -20 to +71
Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max
C
,
,
(
)
,
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
2
C
ENVIRONMENT
,
(
),
,
VIBRATION
IMPACT
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
196.1m/s2 20G 11ms once each X Y and Z axis
(
),
,
,
(
)
,
(
),
,
AGENCY APPROVALS At only AC input UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN
SAFETY AND
NOISE
, , , ,
Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B
Complies with IEC61000-3-2
102 42 170mm [4.02 1.65 6.69 inches] without terminal block and screw
Forced cooling internal fan
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
REGULATIONS
6
*
(
) (
)
H D /1.0kg max
X
W
X
X
X
X
X
OTHERS
(
)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
*5 Please contact us about safety approvals for the model with option.
*6 Please contact us about class C.
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*
A sound may occur from power supply at pulse loading.
*4 Derating is required.Consult us for details.
PBA/PBW-16
PBA300F
PBA/PBW
Block diagram
FUSE
AC IN
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
85
-
264V
250V10A
FG
RECTIFIER
AND
INVERTER
DC OUT
FILTER
±M
THERMAL
PROTECTION
CURRENT
SENSING
OVER VOLTAGE
PROTECTION
ACTIVE FILTER
RECTIFIER
AND
FILTER
CONTROL
SWITCHING
DEVICE
CONTROL
±S(REMOTE SENSING)
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
MASTER
SLAVE
CONTROL
VOLTAGE
SENSING
CURRENT
SENSING
VOLTAGE
SENSING
INTERNAL
REGULATOR
CONTROL
FAN
ALARM
PG(POWER GOOD)
AUX(12V 0.1A)
External view
4-M4
Mounting Hole
±0.5
74
[2.91]
54
[2.13]
2-M4
Name plate
(14)
[0.55]
25max
[0.98]
Mounting Hole
(Bottom side)
M4
Terminal cover
AC(L)
AC(N)
FG(
)
Output terminal(-)
Output terminal(+)
M4
CN3
CN2
CN1
LED
Name plate
(15.5)
[0.61]
(30)
±0.5
28.5
[1.12]
64
[2.52]
170
[6.69]
6max
[0.24]
[1.18]
Output voltage
adjustable potentiometer
AIR FLOW
¶ Tolerance : ±1 [±0.04]
¶ Weight : 1.0kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [
]= inches
¶ Mounting torque : 1.2N • m max
¶ Screw tightening torque : 1.6N • m max
¶ The housing for the remote sensing unused is mounted on CN1
¶ Please connect safety ground to FG terminal on the unit.
PBA/PBW-17
Ordering information
AC-DC Power Supplies Enclosed Type
PBA/PBW
PB
A
600
F
-5
-O
6
PBA600F
1
2
3
4
5
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *6
Recommended EMI/EMC Filter
NAC-16-472
R
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F1 :With Long-Life fan
F3 :Reverse air exhaust
type
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
F4 :Low speed fan
Refer to instruction manual
7.1.
MODEL
PBA600F-3R3 PBA600F-5
PBA600F-7R5 PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48
MAX OUTPUT WATTAGE[W]
396
600
600
636
645
648
648
624
ACIN 100V 3.3V 120A
5V 120A
5V 120A
7.5V 80A
7.5V 80A
12V 53A
12V 53A
15V 43A
15V 43A
24V 27A
( )
24V 27 31 A
36V 18A
36V 18A
48V 13A
48V 13A
DC OUTPUT
3
*
ACIN 200V
3.3V 120A
SPECIFICATIONS
MODEL
PBA600F-3R3 PBA600F-5
PBA600F-7R5 PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48
(
)
5
VOLTAGE[V]
AC85 - 264 1 or DC120 - 350 AC50 or DC70 Please refer to the instruction manual 7. option
f
*
ACIN 100V 5.8typ
ACIN 200V 3typ
8.2typ
4.1typ
CURRENT[A]
( )
50/60 47 - 63
FREQUENCY[Hz]
ACIN 100V 70typ
ACIN 200V 72typ
75typ
77typ
76typ
79typ
79typ
82typ
79typ
82typ
81typ
84typ
82typ
84typ
81typ
83typ
EFFICIENCY[%]
INPUT
(
(
)
)
ACIN 100V 0.98typ Io=100%
POWER FACTOR
ACIN 200V 0.95typ Io=100%
(
(
) (
) (
) (
) (
)
)
ACIN 100V 20/40typ Io=100% Primary inrush current /Secondary inrush current More than 3 sec. to re-start
INRUSH CURRENT[A]
ACIN 200V 40/40typ Io=100% Primary inrush current /Secondary inrush current More than 3 sec. to re-start
(
,
,
,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.45/0.75max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1 DENAN
3.3
5
120
7.5
80
12
53
15
43
24
27
36
48
ACIN 100V 120
18
13
CURRENT[A]
3
*
(
)
ACIN 200V
120
120
80
53
43
27 31
18
13
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
80max
140max
120max
160max
40max
60max
12max
20max
40max
80max
140max
120max
160max
50max
75max
20max
36max
60max
120max
160max
150max
180max
75max
120max
30max
48max
100max
120max
160max
150max
180max
120max
180max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
144max
150max
150max
160max
200max
240max
360max
440max
144max
192max
300max
150max
400max
200max
500max
480max
600max
192max
150max
120max
160max
150max
180max
240max
290max
96max
1
1
1
1
0 to +50
*
*
*
*
C
RIPPLE[mVp-p]
-20 - 0
C
0 to +50
C
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
-20 - 0
C
0 to +50
C
-20 to +50
C
2
*
DRIFT[mV]
(
(
,
)
400typ ACIN 100/200V Io=100%
*
START-UP TIME[ms]
HOLD-UP TIME[ms]
Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
,
)
20typ ACIN 100/200V Io=100%
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40
3.96 - 6.00
5.00 - 5.15
5.25 - 8.25
7.50 - 7.80
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
4
*
OVERVOLTAGE PROTECTION[V]
CIRCUIT AND OPERATING INDICATION
Vo+0.66 - 1.32 Vo+1.0 - 2.0
Vo+1.5 - 3.0
Vo+2.4 - 4.8
Vo+3.0 - 6.0
Vo+4.8 - 9.6
Vo+7.2 - 14.4 Vo+4.8 - 12.0
PROTECTION
(
)
LED Green
OTHERS
REMOTE SENSING
REMOTE ON/OFF
Provided
Provided
, , , (
AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
INPUT-OUTPUT RC
INPUT-FG
-
, , , (
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
ISOLATION
,
,
(
)
OUTPUT RC AUX-FG
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
-
-
W
,
,
(
)
OUTPUT-RC AUX
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
-
W
,
(
),
(
)
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -20 to +71
Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max
C
,
,
(
)
,
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
2
C
ENVIRONMENT
,
(
),
,
VIBRATION
IMPACT
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
196.1m/s2 20G 11ms once each X Y and Z axis
(
),
,
,
(
)
,
(
),
,
AGENCY APPROVALS At only AC input UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN
SAFETY AND
NOISE
, , , ,
Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B
Complies with IEC61000-3-2
120 61 190mm [4.72 2.4 7.48 inches] without terminal block and screw
Forced cooling internal fan
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
REGULATIONS
7
*
(
) (
)
H D /1.6kg max
X
W
X
X
X
X
X
OTHERS
(
)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*5 Derating is required.Consult us for details.
*6 Please contact us about safety approvals for the model with option.
*7 Please contact us about class C.
*
A sound may occur from power supply at pulse loading.
*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
PBA/PBW-18
PBA600F
PBA/PBW
Block diagram
FUSE
AC IN
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
85
-
264V
250V15A
FG
RECTIFIER
AND
INVERTER
DC OUT
FILTER
±M
THERMAL
PROTECTION
CURRENT
SENSING
OVER VOLTAGE
PROTECTION
ACTIVE FILTER
RECTIFIER
AND
FILTER
CONTROL
SWITCHING
DEVICE
CONTROL
±S(REMOTE SENSING)
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
MASTER
SLAVE
CONTROL
VOLTAGE
SENSING
CURRENT
SENSING
VOLTAGE
SENSING
INTERNAL
REGULATOR
CONTROL
FAN
ALARM
PG(POWER GOOD)
AUX(12V 0.1A)
External view
Name plate
Input terminal cover
4-M4
Mounting Hole
(Bottom side)
(13.8)
[0.54]
20max
[0.79]
M4
Name plate
AC(L)
AC(N)
FG(
)
CN3
Output
terminal(-)
CN2
CN1
LED
Output
terminal(+)
Output terminal cover
Output voltage
25max
[0.98]
±0.5
24
[0.94]
150
(18)
[0.71]
M5
(48.5)
[5.91]
¶1(F1:190.5)
190
[7.48]
6max
[0.24]
adjustable potentiometer
[1.91]
8-M4
61
Mounting Hole
(Both side)
[2.4]
AIR FLOW
¶ Tolerance : ±1 [±0.04]
¶ Weight : 1.6kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
±0.5
24
[0.94]
150
[5.91]
¶ Dimensions in mm, [
]= inches
¶ Mounting torque : 1.2N · m(12.8kgf·cm)max
¶ Screw tightening torque : M4 1.6N • m(16.9kgf • cm)max
M5 2.5N • m(24.5kgf • cm)max
¶ The housing for the remote sensing unused is mounted on CN1
¶1 F1(Optional):190.5
¶ Please connect safety ground to FG terminal on the unit.
PBA/PBW-19
Ordering information
AC-DC Power Supplies Enclosed Type
PBA/PBW
PB
A 1000 F
-5
-O
6
PBA1000F
1
2
3
4
5
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *6
Recommended EMI/EMC Filter
NAC-20-472
R
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F1 :With Long-Life fan
F3 :Reverse air exhaust
type
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
F4 :Low speed fan
Refer to instruction manual
7.1.
MODEL
PBA1000F-3R3 PBA1000F-5
PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48
MAX OUTPUT WATTAGE[W]
660
1000
1005
1056
1050
1056
1044
1056
ACIN 100V 3.3V 200A
5V 200A
5V 200A
7.5V 134A
7.5V 134A
12V 88A
12V 88A
15V 70A
15V 70A
24V 44A
( )
24V 44 51 A
36V 29A
36V 29A
48V 22A
48V 22A
DC OUTPUT
3
*
ACIN 200V
3.3V 200A
SPECIFICATIONS
MODEL
PBA1000F-3R3 PBA1000F-5
PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48
(
)
5
VOLTAGE[V]
AC85 - 264 1 or DC120 - 350 AC50 or DC70 Please refer to the instruction manual 7. option
f
*
ACIN 100V 9typ
ACIN 200V 5typ
13typ
7typ
CURRENT[A]
( )
50/60 47 - 63
FREQUENCY[Hz]
ACIN 100V 74typ
ACIN 200V 76typ
79typ
81typ
80typ
83typ
82typ
84typ
82typ
84typ
84typ
86typ
84typ
86typ
84typ
86typ
EFFICIENCY[%]
INPUT
(
(
)
)
ACIN 100V 0.98typ Io=100%
POWER FACTOR
ACIN 200V 0.95typ Io=100%
(
(
) (
) (
) (
) (
)
)
ACIN 100V 20/40typ Io=100% Primary inrush current /Secondary inrush current More then 10 sec. to re-start
INRUSH CURRENT[A]
ACIN 200V 40/40typ Io=100% Primary inrush current /Secondary inrush current More then 10 sec. to re-start
( , , ,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.5/1.0max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1 DENAN
3.3
5
7.5
12
15
24
44
44 51
36
29
29
48
22
22
ACIN 100V 200
200
134
88
70
CURRENT[A]
3
*
(
)
ACIN 200V
200
200
134
88
70
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
80max
140max
120max
160max
40max
60max
12max
20max
40max
80max
140max
120max
160max
50max
75max
20max
36max
60max
120max
160max
150max
180max
75max
120max
30max
48max
100max
120max
160max
150max
180max
120max
180max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
144max
150max
150max
160max
200max
240max
360max
440max
144max
192max
300max
150max
400max
200max
500max
480max
600max
192max
150max
120max
160max
150max
180max
240max
290max
96max
1
1
1
1
0 to +50
*
*
*
*
C
RIPPLE[mVp-p]
-20 - 0
C
0 to +50
C
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
-20 - 0
C
0 to +50
C
-20 to +50
C
2
*
DRIFT[mV]
(
(
,
)
400typ ACIN 100/200V Io=100%
*
START-UP TIME[ms]
HOLD-UP TIME[ms]
Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
,
)
20typ ACIN 100/200V Io=100%
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40
3.96 - 6.00
5.00 - 5.15
5.25 - 8.25
7.50 - 7.80
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
4
*
OVERVOLTAGE PROTECTION[V]
CIRCUIT AND OPERATING INDICATION
Vo+0.66 - 1.32 Vo+1.0 - 2.0
Vo+1.5 - 3.0
Vo+2.4 - 4.8
Vo+3.0 - 6.0
Vo+4.8 - 9.6
Vo+7.2 - 14.4 Vo+4.8 - 12.0
PROTECTION
(
)
LED Green
OTHERS
REMOTE SENSING
REMOTE ON/OFF
Provided
Provided
, , , (
AC3 000V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature
W
)
INPUT-OUTPUT RC
INPUT-FG
-
, , , (
AC2 000V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature
W
)
ISOLATION
,
,
(
)
OUTPUT RC AUX-FG
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
-
-
W
,
,
(
)
OUTPUT-RC AUX
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
-
W
,
(
),
(
)
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -20 to +71
Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max
C
,
,
(
)
,
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
2
C
ENVIRONMENT
,
(
),
,
VIBRATION
IMPACT
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
196.1m/s2 20G 11ms once each X Y and Z axis
(
),
,
,
(
)
,
(
),
,
AGENCY APPROVALS At only AC input UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN
SAFETY AND
NOISE
, , , ,
Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B
Complies with IEC61000-3-2
150 61 240mm [5.91 2.4 9.45 inches] without terminal block and screw
Forced cooling internal fan
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
REGULATIONS
7
*
(
) (
)
H D /2.2kg max
X
W
X
X
X
X
X
OTHERS
(
)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within
150mm from the output terminal.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*5 Derating is required.Consult us for details.
*6 Please contact us about safety approvals for the model with option.
*7 Please contact us about class C.
*
A sound may occur from power supply at pulse loading.
PBA/PBW-20
PBA1000F
PBA/PBW
Block diagram
FUSE
AC IN
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
85
-
264V
250V30A
FG
RECTIFIER
AND
INVERTER
DC OUT
FILTER
±M
THERMAL
PROTECTION
CURRENT
SENSING
OVER VOLTAGE
PROTECTION
ACTIVE FILTER
RECTIFIER
AND
FILTER
CONTROL
SWITCHING
DEVICE
CONTROL
±S(REMOTE SENSING)
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
MASTER
SLAVE
CONTROL
VOLTAGE
SENSING
CURRENT
SENSING
VOLTAGE
SENSING
INTERNAL
REGULATOR
CONTROL
FAN
ALARM
PG(POWER GOOD)
AUX(12V 0.1A)
External view
4-M4
Mounting Hole
(Bottom side)
Name plate
M4
Input terminal cover
25max
[0.98]
15.85
[0.62]
AC(L)
AC(N)
FG(
)
Name plate
CN3
CN2
CN1
Output voltage
adjustable potentiometer
LED
Output terminal(-)
Output terminal(+)
±0.5
51.25
[2.02]
29
[1.14]
165
[6.5]
(35)
[1.38]
240
[9.45]
6max
[0.24]
8-M4
Mounting Hole
(Both side)
2-M4
2-º9
[0.35]
AIR FLOW
±0.5
165
[6.5]
¶ Tolerance : ±1 [±0.04]
¶ Weight : 2.2kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [
¶ Mounting torque : 1.2N • m(12.8kgf • cm)max
¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max
7
13
29
[1.14]
[0.28] [0.51]
]= inches
¶ The housing for the remote sensing unused is mounted on CN1
¶ Please connect safety ground to FG terminal on the unit.
PBA/PBW-21
Ordering information
AC-DC Power Supplies Enclosed Type
PBA/PBW
PB
A 1500 F
-5
-O
6
PBA1500F
1
2
3
4
5
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *6
Recommended EMI/EMC Filter
NAC-20-472
R
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F1 :With Long-Life fan
F3 :Reverse air exhaust
type
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
F4 :Low speed fan
Refer to instruction manual
7.1.
MODEL
PBA1500F-3R3 PBA1500F-5
PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48
MAX OUTPUT WATTAGE[W]
990
1500
1500
1500
1500
1680
1692
1680
ACIN 100V 3.3V 300A
5V 300A
5V 300A
7.5V 200A
7.5V 200A
12V 125A
12V 125A
15V 100A
15V 100A
24V 65A
( ) ( )
24V 70 105 A 36V 47 70 A
36V 42A
48V 32A
48V 35A
DC OUTPUT
3
*
ACIN 200V
3.3V 300A
SPECIFICATIONS
MODEL
PBA1500F-3R3 PBA1500F-5
PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48
(
)
5
VOLTAGE[V]
AC85 - 264 1 or DC120 - 370 AC50 or DC70 Please refer to the instruction manual 7. option
f
*
ACIN 100V 15typ
ACIN 200V 8typ
19typ
10typ
CURRENT[A]
( )
50/60 47 - 63
FREQUENCY[Hz]
ACIN 100V 72typ
ACIN 200V 75typ
77typ
81typ
81typ
83typ
81typ
84typ
83typ
86typ
84typ
87typ
84typ
87typ
84typ
87typ
EFFICIENCY[%]
INPUT
(
(
)
)
ACIN 100V 0.98typ Io=100%
POWER FACTOR
ACIN 200V 0.95typ Io=100%
(
(
) (
) (
) (
) (
)
)
ACIN 100V 20/40typ Io=100% Primary inrush current /Secondary inrush current More than 10 sec. to re-start
INRUSH CURRENT[A]
ACIN 200V 40/40typ Io=100% Primary inrush current /Secondary inrush current More than 10 sec. to re-start
( , , ,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.9/1.5max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1 DENAN
3.3
5
7.5
12
15
24
65
70 105
36
42
48
32
ACIN 100V 300
300
200
125
100
CURRENT[A]
3
*
(
)
(
)
ACIN 200V
300
300
200
125
100
47 70
35
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
80max
140max
120max
160max
40max
60max
12max
20max
40max
80max
140max
120max
160max
50max
75max
20max
36max
60max
120max
160max
150max
180max
75max
120max
30max
48max
100max
120max
160max
150max
180max
120max
180max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
144max
150max
150max
160max
200max
240max
360max
440max
144max
192max
300max
150max
400max
200max
500max
480max
600max
192max
150max
120max
160max
150max
180max
240max
290max
96max
1
1
1
1
0 to +50
*
*
*
*
C
RIPPLE[mVp-p]
-20 - 0
C
0 to +50
C
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
-20 - 0
C
0 to +50
C
-20 to +50
C
2
*
DRIFT[mV]
(
(
,
,
)
)
START-UP TIME[ms]
HOLD-UP TIME[ms]
600typ ACIN 100/200V Io=100%
20typ ACIN 100/200V Io=100%
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40
3.96 - 6.00
5.00 - 5.15
5.25 - 8.25
7.50 - 7.80
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
4
*
OVERVOLTAGE PROTECTION[V]
CIRCUIT AND OPERATING INDICATION
Vo+0.66 - 1.32 Vo+1.0 - 2.0
Vo+1.5 - 3.0
Vo+2.4 - 4.8
Vo+3.0 - 6.0
Vo+4.8 - 9.6
Vo+7.2 - 14.4 Vo+4.8 - 12.0
PROTECTION
(
)
LED Green
OTHERS
REMOTE SENSING
REMOTE ON/OFF
Provided
Provided
, , , (
AC3 000V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature
W
)
INPUT-OUTPUT RC
INPUT-FG
-
, , , (
AC2 000V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature
W
)
ISOLATION
,
,
(
)
OUTPUT RC AUX-FG
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
-
-
W
,
,
(
)
OUTPUT-RC AUX
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
-
W
,
(
),
(
)
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -20 to +71
Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max
C
,
,
(
)
,
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
2
C
ENVIRONMENT
,
(
),
,
VIBRATION
IMPACT
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
196.1m/s2 20G 11ms once each X Y and Z axis
(
),
,
,
(
)
,
(
),
,
,
AGENCY APPROVALS At only AC input UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN
SAFETY AND
NOISE
,
,
,
,
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B additional EMI/EMC Filter required for meeting class B
Complies with IEC61000-3-2
178 61 268mm [7.01 2.4 10.55 inches] without terminal block and screw
Forced cooling internal fan
REGULATIONS
7
*
(
) (
)
H D /3.4kg max
X
W
X
X
X
X
X
OTHERS
(
)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within
150mm from the output terminal.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*5 Derating is required.Consult us for details.
*6 Please contact us about safety approvals for the model with option.
*7 Please contact us about class C.
*
A sound may occur from power supply at pulse loading.
PBA/PBW-22
PBA1500F
PBA/PBW
Block diagram
FUSE
AC IN
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
85
-
264V
250V30A
FG
RECTIFIER
AND
INVERTER
DC OUT
FILTER
±M
THERMAL
PROTECTION
CURRENT
SENSING
OVER VOLTAGE
PROTECTION
ACTIVE FILTER
RECTIFIER
AND
FILTER
CONTROL
SWITCHING
DEVICE
CONTROL
±S(REMOTE SENSING)
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
MASTER
SLAVE
CONTROL
VOLTAGE
SENSING
CURRENT
SENSING
VOLTAGE
SENSING
INTERNAL
REGULATOR
CONTROL
FAN
ALARM
PG(POWER GOOD)
AUX(12V 0.1A)
External view
8-M4
Mounting Hole
(Both sides)
Name plate
Input terminal cover
25max
[0.98]
15.85
[0.62]
M4
AC(L)
AC(N)
NC
FG(
)
CN1
CN2
CN3
Name plate
Output voltage
adjustable potentiometer
LED
Output terminal(-)
Output terminal(+)
51.25
[2.02]
±0.5
171.5
19
[0.75]
[6.75]
(45)
[1.77]
268
[10.55]
6max
[0.24]
8-M4
Mounting Hole
(Both sides)
4-M4
2-º9
[0.35]
AIR FLOW
¶ Tolerance : ±1 [±0.04]
¶ Weight : 3.4kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [
¶ Mounting torque : 1.2N • m(12.8kgf • cm)max
¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max
10 15
[0.39][0.59]
±0.5
171.5
[6.75]
19
[0.75]
]= inches
¶ The housing for the remote sensing unused is mounted on CN1
¶ Please connect safety ground to FG terminal on the unit.
PBA/PBW-23
Ordering information
AC-DC Power Supplies Enclosed Type
PBA/PBW
PB
A 1500 T
-5
-O
6
PBA1500T
1
2
3
4
5
1Series name
2Single output
3Output wattage
Recommended EMI/EMC Filter
TAC-10-683
R
4Triple input phase
5Output voltage
6Optional *6
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F1 :With Long-Life fan
F3 :Reverse air exhaust
type
F4 :Low speed fan
Refer to instruction manual
7.1.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA1500T-5
1500
5V 300A
PBA1500T-12
1500
12V 125A
PBA1500T-24
1680
PBA1500T-48
1680
48V 35A
3
*
(
)
ACIN 200V
24V 70 105 A
SPECIFICATIONS
MODEL
PBA1500T-5
PBA1500T-12
PBA1500T-24
PBA1500T-48
(
)
5
*
AC170 - 264 3
AC100 Please refer to the instruction manual 7. option
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
f
6typ
ACIN 200V
ACIN 200V
(
)
50/60 47 - 63
INPUT
81typ
84typ
EFFICIENCY[%]
87typ
87typ
(
)
ACIN 200V 0.95typ Io=100%
POWER FACTOR
(
)
(
) (
)
ACIN 200V 40/40typ Io=100% Primary inrush current /Secondary inrush current More than 10 sec. to re-start
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
(
,
,
,
)
1.5max ACIN 240V 60Hz Io=100% According to IEC60950-1 DENAN
5
12
24
48
35
VOLTAGE[V]
3
*
ACIN 200V
CURRENT[A]
300
125
(
)
70 105
20max
40max
80max
140max
120max
160max
50max
75max
20max
48max
100max
120max
160max
150max
180max
120max
180max
48max
96max
192max
300max
150max
400max
200max
500max
480max
600max
192max
LINE REGULATION[mV]
LOAD REGULATION[mV]
150max
120max
160max
150max
180max
240max
290max
96max
1
1
1
1
0 to +50
*
*
*
*
C
RIPPLE[mVp-p]
-20 - 0
C
0 to +50
-20 - 0
C
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
OUTPUT
C
0 to +50
C
-20 to +50
C
2
*
DRIFT[mV]
(
,
)
300typ ACIN 200V Io=100%
*
START-UP TIME[ms]
HOLD-UP TIME[ms]
Start-up time is 500ms typ for less than 1 minute of applying input again from turning off the input voltage.
(
,
)
20typ ACIN 200V Io=100%
3.96 - 6.00
8.25 - 13.20
16.50 - 26.40
24.00 - 24.96
38.40 - 56.00
48.00 - 49.92
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V] 5.00 - 5.15
12.00 - 12.48
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
4
*
Vo+2.4 - 4.8
Vo+4.8 - 9.6
Vo+2.0 - 12.0
Vo+1.0 - 2.0
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE SENSING
PROTECTION
CIRCUIT AND
OTHERS
(
)
LED Green
Provided
Provided
REMOTE ON/OFF
, , , (
AC3 000V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature
W
)
INPUT-OUTPUT RC
-
,
,
,
(
)
AC2 000V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature
INPUT-FG
W
ISOLATION
,
,
(
)
OUTPUT RC AUX-FG
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
-
-
W
,
,
(
)
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
OUTPUT-RC AUX
W
-
(
),
(
)
,
(
,
)
,
-20 to +71
-20 to +75
Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max
OPERATING TEMP. HUMID.AND ALTITUDE
C
,
(
)
,
(
,
)
,
20 - 90%RH Non condensing 9 000m 30 000feet max
STORAGE TEMP. HUMID.AND ALTITUDE
C
ENVIRONMENT
2
,
(
),
,
,
VIBRATION
IMPACT
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
196.1m/s2 20G 11ms once each X Y and Z axis
),
(
,
,
SAFETY AND
NOISE
,
(
),
,
(
)
UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN
AGENCY APPROVALS At only AC input
,
,
,
,
,
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B additional EMI/EMC Filter required for meeting class B
REGULATIONS
(
) (
)
W H D /3.4kg max
X X
178 61 268mm [7.01 2.4 10.55 inches] without terminal block and screw
X
X
X
X
OTHERS
(
)
Forced cooling internal fan
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within
150mm from the output terminal.
*5 Derating is required.Consult us for details.
*6 Please contact us about safety approvals for the model with option.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*
A sound may occur from power supply at pulse loading.
PBA/PBW-24
PBA1500T
PBA/PBW
Block diagram
FUSE
AC250V16A
INRUSH
CURRENT
LIMIT
AC IN
NOISE
FILTER
RECTIFIER
170
-
264V
(3º)
FG
RECTIFIER
AND
INVERTER
DC OUT
FILTER
±M(MONITOR)
THERMAL
PROTECTION
CURRENT
SENSING
OVER VOLTAGE
PROTECTION
ACTIVE FILTER
RECTIFIER
AND
FILTER
CONTROL
SWITCHING
DEVICE
CONTROL
±S(REMOTE SENSING)
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
MASTER
SLAVE
CONTROL
VOLTAGE
SENSING
CURRENT
SENSING
VOLTAGE
SENSING
INTERNAL
REGULATOR
CONTROL
FAN
ALARM
PG(POWER GOOD)
AUX(12V 0.1A)
OPEN
PHASE
External view
8-M4
Mounting Hole
(Both sides)
Name plate
Input terminal cover
25max
[0.98]
15.85
[0.62]
M4
AC(L1)
AC(L2)
AC(L3)
FG(
)
CN1
CN2
CN3
Name plate
Output voltage
adjustable potentiometer
LED
Output terminal(-)
Output terminal(+)
51.25
[2.02]
±0.5
171.5
19
[0.75]
[6.75]
(45)
[1.77]
268
6max
[0.24]
[10.55]
8-M4
Mounting Hole
(Both sides)
4-M4
2-º9
[0.35]
AIR FLOW
¶ Tolerance : ±1 [±0.04]
¶ Weight : 3.4kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [
¶ Mounting torque : 1.2N • m(12.8kgf • cm)max
¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max
10 15
[0.39][0.59]
±0.5
171.5
[6.75]
19
[0.75]
]= inches
¶ The housing for the remote sensing unused is mounted on CN1
¶ Please connect safety ground to unit in M4 holes.
PBA/PBW-25
PBA300F-3R3-C 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
PBA300F-3R3-CF4 | COSEL | AC-DC Regulated Power Supply Module, | 获取价格 | |
PBA300F-3R3-F4 | COSEL | AC-DC Regulated Power Supply Module, 198W | 获取价格 | |
PBA300F-3R3-N1 | COSEL | AC-DC Regulated Power Supply Module, 198W | 获取价格 | |
PBA300F-48 | TOTAL-POWER | PBA300F | 获取价格 | |
PBA300F-48 | RSG | Unit type | 获取价格 | |
PBA300F-48-CF3 | COSEL | AC-DC Regulated Power Supply Module, | 获取价格 | |
PBA300F-48-CF4 | COSEL | AC-DC Regulated Power Supply Module, | 获取价格 | |
PBA300F-48-G | COSEL | AC-DC Regulated Power Supply Module, 336W | 获取价格 | |
PBA300F-48-GU | COSEL | AC-DC Regulated Power Supply Module, | 获取价格 | |
PBA300F-48-UN1 | COSEL | AC-DC Regulated Power Supply Module, | 获取价格 |