Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 VOLT INPUT – 30 WATT  
FEATURES  
Single, Dual and Triple models  
Operating temperature -55° to +125°C  
Qualified to MIL-PRF-38534 Class H and K  
Radiation hardness assurance (RHA)  
to level R 100 krad(Si)  
Input voltage range 16 to 40 VDC  
Transient protection 50 V for 50 ms  
Fully isolated, magnetic feedback  
Fixed high frequency switching, 600 kHz typical  
Trim function or remote sense on single output models  
Inhibit function  
ꢀODEꢁS  
VDC Output  
Synchronization function  
SINGLE  
DUAL  
±5  
TRIPLE  
+5 & ±12  
+5 & ±15  
Indefinite short circuit protection  
3.3  
5
Up to 84% efficiency (up to 73% efficiency triple models)  
±12  
±15  
12  
15  
DESCRIPTION  
The Interpoint™ SMTR Series™ of 28 volt dc-dc converters  
offers up to 30 watts of output power from single, dual or  
triple output configurations. They operate over the full military  
temperature range of -55°C to +125°C with up to 84% efficiency  
(up to 73% efficiency triple models). SMTR converters are  
packaged in hermetically sealed metal enclosures, making them  
ideal for use in military, aerospace and other high reliability  
applications.  
converter DeSign  
The SMTR converters are constant frequency, pulse-width  
modulated switching regulators which use a quasi-square wave,  
single ended, forward converter design. Tight load regulation is  
maintained by using a wide bandwidth magnetic feedback and,  
on single output models, through use of remote sense. On dual  
output models, the positive output is independently regulated and  
the negative output is cross regulated through the use of tightly-  
coupled magnetics. The triple output dc-dc converter’s  
Screening  
design includes individual regulators on the auxiliary outputs  
SMTR converters offer screening options to Space Prototype (O), which provide for no cross regulation error when a minimum  
Class H, or Class K. Radiation tolerant to Radiation Hardness  
Assurance (RHA) levels of “-” (O), “P,” or “R,” per MIL-STD-  
38534. Interpoint™ model numbers use an “O” in the RHA  
designator position to indicate the “-” (dash) Radiation Hardness  
Assurance level of MIL-PRF-38534, which is defined as “no  
RHA”. See “Table 11: Element Evaluation” on page 19 and  
“Table 12: Environmental Screening and RHA Levels” on page  
20 for more information.  
300 mA load is maintained on the main (+5 V) output.  
SMTR converters have an internal input filter that helps reduce  
the need for external components in normal operation. Use our  
SFMC EMI input filter to meet the requirements of MIL-STD-  
461C’s CE03. For the lowest noise performance, connection  
of the case to input common is recommended. The connection  
can be hard-wired or AC coupled with a small ceramic bypass  
capacitor. Indefinite short circuit protection and overload  
protection are provided by a constant current-limit feature. This  
protective system senses current in the converter’s secondary  
stage and limits it to approximately 140% of the maximum rated  
output current.  
Crane Aerospace & Electronics  
Page 1 of 20  
Power Solutions – Interpoint Products  
10301 Willows Rd. NE, Redmond, WA 98052  
+1.425.882.3100 • power@crane-eg.com  
www.craneae.com/interpoint  
SMTR Rev AA - 2013.04.18  
The information in this document is a derivative of documents cleared by the Department  
of Defense (DoD) Office of Security Review (OSR) for public release. OSR case numbers  
09-S-1002 dated March 24, 2009 and 12-S-2048 dated May 29, 2012.  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
Synchronization  
improveD Dynamic reSponSe  
Synchronizing the converter with the system clock allows  
the designer to confine switching noise to clock transitions,  
minimizing interference and reducing the need for filtering. In  
sync mode, the converter will run at any frequency between 500  
kHz and 675 kHz. The sync control operates with an active high  
at any duty cycle between 40% and 60%. The sync pin should be  
connected to input common pin when not in use.  
The SMTR Series feed-forward compensation system provides  
excellent dynamic response and noise rejection. Audio rejection  
is typically 40 dB (50 dB for Triple output models). The min. to  
max. step line transient response is typically less than 4%.  
inhibit Function  
SMTR converters provide an inhibit terminal that can be used to  
disable internal switching, resulting in no output voltage and very  
low quiescent input current. The converter is inhibited when the  
inhibit pin is pulled below 0.8 V and enabled when its inhibit pin  
is left floating. An external inhibit interface should be capable of  
pulling the converter’s inhibit pin below 0.8 V while sinking the  
maximum inhibit current and also allowing the inhibit pin to float  
high to enable the converter. A voltage should not be applied to  
the inhibit pin. The open circuit voltage present on the inhibit pin  
is 9 to 11 V.  
WiDe voltage range  
SMTR converters are designed to provide full power operation  
over a full 16 to 40 VDC voltage range. Operation below 16  
volts, including MIL-STD-704D emergency power conditions  
is possible with derated power. Refer to the low line dropout  
graphs (“Figure 23” on page 13, “Figure 31” on page 14 and  
“Figure 32” on page 14) for details.  
www.craneae.com/interpoint  
Page 2 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
TRIꢀ AND REꢀOTE SENSE (AꢂAIꢁAbꢁE ON SINꢃꢁE OUTPUT ꢀODEꢁS ONꢁy)  
SMTR SINGLE OUTPUT CONVERTER  
1
4
OUTPUT  
COMMON  
+V  
IN  
1
SENSE  
RETURN  
3
6
R
L
SENSE  
1
R
T
INPUT  
COMMON  
POSITIVE  
OUTPUT  
10  
5
EXTERNAL TRIM CONNECTION  
Make connections at converter.  
1
1, 2, 3  
Figure 1: trim connection  
SMTR SINGLE OUTPUT CONVERTER  
1
4
OUTPUT  
COMMON  
+V  
IN  
2
2
SENSE  
RETURN  
3
6
R
L
SENSE  
INPUT  
COMMON  
POSITIVE  
OUTPUT  
10  
5
REMOTE SENSE CONNECTION  
Make connections at load.  
2
2, 3  
Figure 2: remote SenSe  
Notes for Remote Sense and Trim  
Trim Formulas Vout = desired output voltage;  
1. When trimming output voltage and/or remote sensing, the  
total output voltage increase must be less than 0.6 volts at the  
converters pins. Do not exceed maximum power.  
R
= trim resistor  
T
2. If neither voltage trim nor remote sense will be used, connect pin 3  
to pin 4 and pin 5 to pin 6 or the output voltage will increase by 1.2  
volts.  
3.3V:  
5V:  
R
R
R
R
= 1300 Vout – 4304  
*
T
T
T
T
1.2475  
3. CAUTION: The converter will be permanently damaged if the  
positive remote sense (pin 6) is shorted to ground. Damage may  
also result if the output common or positive output is disconnected  
from the load with the remote sense leads connected to the load.  
4. When using remote sense for voltage compensation or when using  
remote sense for trim, the output will drift over temperature. Contact  
Applications Engineering for more information at powerapps@  
crane-eg.com  
= 1300 Vout – 6512  
*
1.2475  
12V:  
15V:  
= 1300 Vout – 15631  
*
1.2475  
= 1300 Vout – 19498  
*
1.2475  
www.craneae.com/interpoint  
Page 3 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
PIN OUT  
Dual Output  
Positive Input  
Inhibit  
PINS NOT IN USE  
Leave unconnected  
Pin  
Single Output  
Positive Input  
Inhibit  
Triple Output  
Positive Input  
Main (+5) Output  
Output Common  
Neg. Aux. Output  
Pos. Aux. Output  
Case Ground  
Case Ground  
Inhibit  
Inhibit  
1
Sync In  
Connect to Input Common  
2
3
Sense Lines Must be connected to  
appropriate outputs  
Sense Return  
Output Common  
Positive Output  
Positive Sense  
Case Ground  
Case Ground  
Sync  
Positive Output  
Output Common  
Negative Output  
Case Ground  
Case Ground  
Case Ground  
Sync  
table 2: pinS not in uSe  
4
5
6
7
8
9
Sync  
10  
Input Common  
Input Common  
table 1: pin out  
Input Common  
Dot on top of cover indicates pin one.  
Dot on top of cover indicates pin one.  
1
2
3
4
5
1
2
3
4
5
BOTTOM VIEW  
SMTR DUAL  
FLANGED AND NON-FLANGED  
BOTTOM VIEW  
SMTR SINGLE  
FLANGED AND NON-FLANGED  
10  
9
8
7
6
10  
9
8
7
6
Dotted line outlines flanged package option.  
Dotted line outlines flanged package option.  
For dimensions see “Figure 34: Cases H2” on page 16  
and “Figure 36: Cases K3” on page 18.  
For dimensions see “Figure 34: Cases H2” on page 16  
and “Figure 36: Cases K3” on page 18.  
Figure 4: pin out Smtr Dual output moDelS  
Figure 3: pin out Smtr Single output moDelS  
Squared corner and dot on top  
of package indicate pin one.  
1
2
3
4
5
6
BOTTOM VIEW  
SMTR TRIPLE  
FLANGED AND NON-FLANGED  
10  
9
8
7
Dotted line outlines flanged package option.  
For dimensions see “Figure 33: Case F1” on page 15  
and “Figure 35: Case J1” on page 17.  
Figure 5: pin out Smtr triple  
www.craneae.com/interpoint  
Page 4 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
ꢀODEꢁ NUꢀbERINꢃ kEy  
SꢀD NUꢀbERS  
StanDarD MiCrOCirCuit  
SMtr SiMilar part  
Drawing (SMD)  
SMTR 28 512 T F / K R  
5962R0150102KXC  
5962R9306802KXC  
5962R9306902KXC  
5962R9307002KXC  
5962R9320502KXC  
5962R9307102KXC  
5962R9307202KXC  
5962R9307402KXC  
SMTR283R3S/KR  
SMTR2805S/KR  
SMTR2812S/KR  
SMTR2815S/KR  
SMTR2805D/KR  
SMTR2812D/KR  
SMTR2815D/KR  
SMTR28515T/KR  
Base Model  
Input Voltage  
Output Voltage  
(Main and aux. Vout for triple models)  
Number of Outputs  
(S=single, D=dual, T=triple)  
Case Option  
("F" indicates flanged option, non-flanged  
case has no designator in this position)  
To indicate the flanged case option change the “X” to “Z” In the  
SMD number. The SMD number shown is for Class K screening,  
non-flanged, and Radiation Hardness Assurance (RHA) level R.  
See the SMD for the numbers for other screening and radiation  
levels. For exact specifications for an SMD product, refer to the  
SMD drawing. SMDs can be downloaded from:  
Screening  
Radiation Hardness  
Assurance (RHA)  
http://www.dscc.dla.mil/programs/smcr  
Figure 6: moDel numbering Key  
table 3: SmD numberS  
ꢀODEꢁ NUꢀbER OPTIONS  
tO DeterMine the MODel nuMber enter One OptiOn frOM  
eaCh CategOry in the fOrM belOw.  
1
3
4
5
base ꢀodel and  
Input ꢂoltage  
Output ꢂoltage  
Numꢄer of  
Case Options  
Screening  
RHA  
CATEꢃORy  
OPTIONS  
2
Outputs  
3R3, 05, 12, 15  
05, 12, 15  
S
D
T
(non-flanged, leave blank)  
F (flanged)  
O
H
K
O
P
R
SMTR  
512, 515  
FIꢁꢁ IN FOR  
ꢀODEꢁ #  
Notes:  
__________  
SMTR  
__________  
_______  
_______  
/
1. Output Voltage: An R indicates a decimal point. 3R3 is 3.3 volts out. The 3R3 is only available in single output models. The 512 and 515 triple output converters  
are +5 volt main and ±12 or ±15 volt auxiliaries.  
2. Number of Outputs: S is a single output, D is a dual output, and T is a triple output  
3. Case Options: For the standard case (cases “Figure 33: Case F1” on page 15 and “Figure 34: Cases H2” on page 16) leave the case option blank. For the  
flanged case option (cases “Figure 35: Case J1” on page 17 and “Figure 36: Cases K3” on page 18), insert the letter F in the Case Option position.  
4. Screening: A screening level of O is a Space Prototype and is only available with RHA O. See “Table 11: Element Evaluation” on page 19 and “Table 12:  
Environmental Screening and RHA Levels” on page 20 for more information.  
5. RHA: Interpoint model numbers use an “O” in the RHA designator position to indicate the “-” (dash) Radiation Hardness Assurance level of MIL-PRF-38534,  
which is defined as “no RHA.” RHA O is only available with Screening level O. See “Table 12: Environmental Screening and RHA Levels” on page 20 for more  
information.  
table 4: moDel number optionS  
www.craneae.com/interpoint  
Page 5 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
table 5: operating conDitionS - all moDelS - teSteD/analyzeD at 28 vin, rha “o”, unleSS otherWiSe SpeciFieD.  
ALL MODELS  
PARAMETER  
CONDITIONS  
MIN  
TYP  
MAX  
300  
UNITS  
°C  
1
LEAD SOLDERING TEMPERATURE  
10 seconds max.  
1
STORAGE TEMPERATURE  
-65  
-55  
-55  
+150  
+125  
+135  
°C  
CASE OPERATING  
TEMPERATURE  
FULL POWER  
°C  
1
ABSOLUTE  
1
DERATING OUTPUT POWER/CURRENT  
LINEARLY  
From 100% at 125°C to 0% at 135°C  
1
ESD RATING MIL-PRF-38534, 3.9.5.8.2  
SINGLES AND DUALS CLASS 2  
TRIPLES CLASS 1  
2000 - 3999  
V
0 - 1999  
MIL-STD-883, METHOD 3015  
ISOLATION, ANY PIN TO CASE  
EXCEPT CASE PIN  
@ 500 VDC AT 25°C  
100  
Megohms  
1, 2  
CURRENT LIMIT  
% OF FULL LOAD  
SINGLES AND DUALS  
TRIPLES  
140  
40  
50  
600  
%
1
AUDIO REJECTION  
dB  
CONVERSION FREQUENCY  
SYNCHRONIZATION  
FREE RUN -55° TO +125°C  
INPUT FREQUENCY  
550  
500  
40  
650  
675  
60  
0.8  
5
kHz  
kHz  
%
1
Sync is floating and isolated  
DUTY CYCLE  
ACTIVE LOW  
VDC  
1
ACTIVE HIGH  
4.5  
REFERENCED TO  
IF NOT USED  
INPUT COMMON  
CONNECT TO INPUT COMMON  
INHIBIT ACTIVE LOW (OUTPUT DISABLED) INHIBIT PIN PULLED LOW  
0.8  
8
VDC  
mA  
3
1
Do not apply a voltage to the inhibit pin.  
INHIBIT PIN SOURCE CURRENT  
REFERENCED TO  
INPUT COMMON  
OPEN COLLECTOR OR UNCONNECTED  
11  
INHIBIT ACTIVE HIGH (OUTPUT ENABLED) INHIBIT PIN CONDITION  
3
1
Do not apply a voltage to the inhibit pin.  
RADIATION, RHA R  
OPEN PIN VOLTAGE  
9
V
100 krad(Si) total ionizing dose (TID), >250-500 krad(Si)/sec dose rate  
100 krad(Si) TID, <30 mrad(Si)/sec dose rate (LDRS)  
Converter will operate through:  
2
SEE - LET to 40 MeV cm /mg  
Notes:  
1. Guaranteed by qualification test and/or analysis. Not an in-line test.  
2. Dual outputs: The over-current limit will trigger when the sum of the currents from both outputs reaches 140% (typical value) of the maximum  
rated “total” current of both outputs.  
3. An external inhibit interface should be used to pull the inhibit low or leave it floating. The inhibit pin can be left unconnected if not used.  
www.craneae.com/interpoint  
Page 6 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
table 6: electrical characteriSticS:-55°cto +125°c caSe,28vDcvin,100%loaD,Free run,rhao”,unleSS otherWiSe SpeciFieD.  
SINGLE OUTPUT MODELS  
PARAMETER  
SMTR283R3S  
SMTR2805S  
UNITS  
CONDITIONS  
MIN  
TYP  
3.3  
20  
0
MAX  
MIN  
4.85  
0
TYP  
5.00  
MAX  
OUTPUT VOLTAGE  
OUTPUT CURRENT  
OUTPUT POWER  
OUTPUT RIPPLE  
3.201  
0
3.399  
5.45  
18  
5.15  
5.0  
25  
VDC  
A
V
V
T
= 16 TO 40 VDC  
IN  
= 16 TO 40 VDC  
= 25°C  
16  
70  
66  
0
W
IN  
40  
16  
74  
71  
20  
50  
C
C
mV p-p  
10 kHz - 2 MHz  
T
= -55°C TO +125°C  
= 16 TO 40 VDC  
50  
90  
2
LINE REGULATION  
V
20  
10  
10  
28  
50  
mV  
mV  
VDC  
V
IN  
LOAD REGULATION  
INPUT VOLTAGE  
NO LOAD TO FULL  
INPUT CURRENT  
NO LOAD TO FULL  
CONTINUOUS  
TRANSIENT 50 ms  
NO LOAD  
2
20  
50  
28  
30  
25  
73  
±130  
0
40  
40  
1
50  
50  
75  
35  
75  
mA  
INHIBITED  
8
8
3
INPUT RIPPLE CURRENT  
10 kHz - 10 MHz  
50  
25  
78  
50  
mA p-p  
%
EFFICIENCY  
T
T
= 25°C  
C
C
= -55°C TO +125°C  
4
LOAD FAULT  
POWER DISSIPATION  
12  
14  
W
ms  
1
SHORT CIRCUIT  
RECOVERY  
6
5
STEP LOAD RESPONSE  
0% - 100% - 50%  
TRANSIENT  
±300  
200  
±300  
300  
5
±180  
±300  
200  
±300  
300  
5
mV pk  
µs  
5
RECOVERY  
1
STEP LINE RESPONSE  
TRANSIENT  
mV pk  
µs  
5
V
16 - 40 -16 VDC  
RECOVERY  
IN  
6
START-UP  
DELAY  
ms  
1
FULL LOAD  
OVERSHOOT  
50  
0
50  
mV pk  
1
CAPACITIVE LOAD  
NO EFFECT ON DC  
PERFORMANCE  
3000  
3000  
µF  
T
= 25°C  
C
Notes:  
1. Guaranteed by qualification test and/or analysis. Not an in-line test.  
2. Operation is limited below 16 V (see “Figure 23” on page 13).  
3. Tested with 6800 pF ceramic bypass capacitor connected externally from  
input common to case.  
5. Recovery time is measured from application of the transient to the point  
at which VOUT is within 1% of final value.  
6. Tested on release from inhibit.  
4. Short circuit protection not guaranteed above 125°C case temperature.  
www.craneae.com/interpoint  
Page 7 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
table 7: electrical characteriSticS:-55°cto +125°c caSe,28vDcvin,100%loaD,Free run,rhao”,unleSS otherWiSe SpeciFieD.  
SINGLE OUTPUT MODELS  
PARAMETER  
SMTR2812S  
SMTR2815S  
UNITS  
CONDITIONS  
MIN  
11.64  
0
TYP  
12.00  
MAX  
MIN  
14.70  
0
TYP  
15.00  
MAX  
OUTPUT VOLTAGE  
OUTPUT CURRENT  
OUTPUT POWER  
OUTPUT RIPPLE  
12.36  
2.5  
30  
15.30  
2.0  
30  
VDC  
A
Vin = 16 to 40 VDC  
Vin = 16 to 40 VDC  
0
0
W
T
T
= 25°C  
16  
78  
75  
15  
40  
16  
79  
76  
15  
40  
C
C
mV p-p  
10 kHz - 2 MHz  
= -55°C TO +125°C  
= 16 TO 40 VDC  
90  
90  
2
LINE REGULATION  
V
10  
20  
28  
50  
10  
10  
28  
50  
mV  
mV  
VDC  
V
IN  
LOAD REGULATION  
INPUT VOLTAGE  
NO LOAD TO FULL  
INPUT CURRENT  
NO LOAD TO FULL  
CONTINUOUS  
TRANSIENT 50 ms  
NO LOAD  
50  
50  
40  
40  
1
50  
50  
35  
75  
35  
75  
mA  
INHIBITED  
8
8
3
INPUT RIPPLE CURRENT  
10 kHz - 10 MHz  
35  
83  
50  
35  
83  
50  
mA p-p  
%
EFFICIENCY  
T
T
= 25°C  
C
C
= -55°C TO +125°C  
4
LOAD FAULT  
POWER DISSIPATION  
12  
12  
W
ms  
1
SHORT CIRCUIT  
RECOVERY  
5
5
STEP LOAD RESPONSE  
50% - 100% - 50%  
TRANSIENT  
±270  
±400  
200  
±500  
300  
5
±310  
±500  
300  
±600  
300  
5
mV pk  
µs  
5
RECOVERY  
1
STEP LINE RESPONSE  
TRANSIENT  
mV pk  
µs  
5
16 - 40 -16 VDC  
RECOVERY  
6
START-UP  
DELAY  
m sec  
mV pk  
1
FULL LOAD  
OVERSHOOT  
0
120  
0
150  
1
CAPACITIVE LOAD  
NO EFFECT ON DC  
PERFORMANCE  
3000  
3000  
µF  
T
= 25°C  
C
Notes:  
1. Guaranteed by qualification test and/or analysis. Not an in-line test.  
2. Operation is limited below 16 V (see “Figure 23” on page 13).  
5. Recovery time is measured from application of the transient to the point  
at which VOUT is within 1% of final value.  
3. Tested with 6800 pF ceramic bypass capacitor connected externally from  
input common to case.  
6. Tested on release from inhibit.  
4. Short circuit protection not guaranteed above 125°C case temperature.  
www.craneae.com/interpoint  
Page 8 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
table 8: electrical characteriSticS:-55°cto +125°c caSe,28vDcvin,100%loaD,Free run,rhao”,unleSS otherWiSe SpeciFieD.  
DUAL OUTPUT MODELS  
PARAMETER  
SMTR2805D  
SMTR2812D  
SMTR2815D  
UNITS  
VDC  
CONDITIONS  
MIN  
TYP  
5.00  
5.00  
2.5  
MAX  
MIN  
TYP  
12.00  
12.00  
1.25  
MAX  
MIN  
TYP  
15.00  
15.00  
1.00  
MAX  
OUTPUT VOLTAGE  
+ V  
4.85  
4.82  
0
5.15  
5.18  
11.64  
11.58  
0
12.36  
12.42  
14.55  
14.47  
0
15.45  
15.53  
OUT  
- V  
OUT  
2, 3  
1
1
1
OUTPUT CURRENT  
EITHER OUTPUT  
TOTAL OUTPUT  
EITHER OUTPUT  
TOTAL OUTPUT  
4.5  
2.25  
1.80  
A
W
V
= 16 TO 40 VDC  
0
5
0
2.5  
0
2.00  
IN  
2, 3  
1
1
1
OUTPUT POWER  
= 16 to 40 VDC  
12.5  
22.5  
25  
15  
27  
15  
27  
V
16  
0
16  
0
30  
120  
150  
50  
16  
0
30  
80  
IN  
OUTPUT RIPPLE  
T
T
= 25°C  
20  
50  
30  
25  
C
C
mV p-p  
mV  
10 kHz - 2 MHz ± V  
LINE REGULATION  
= -55°C TO +125°C  
90  
120  
50  
OUT  
4
+ V  
- V  
0
50  
0
0
OUT  
V
= 16 TO 40 VDC  
10  
5
100  
50  
15  
5
150  
50  
10  
180  
50  
IN  
OUT  
LOAD REGULATION  
NO LOAD TO FULL  
CROSS REGULATION  
+ V  
OUT  
OUT  
mV  
- V  
15  
100  
12  
30  
150  
8.3  
8.3  
40  
180  
8
SEE NOTE 5  
SEE NOTE 6  
CONTINUOUS  
TRANSIENT 50 ms  
NO LOAD  
%
EFFECT ON -V  
, 25°C  
12  
8
OUT  
INPUT VOLTAGE  
NO LOAD TO FULL  
INPUT CURRENT  
28  
40  
28  
28  
40  
VDC  
V
1
50  
50  
50  
74  
72  
28  
75  
40  
75  
78  
75  
48  
75  
mA  
INHIBITED  
8
77  
75  
8
8
7
INPUT RIPPLE CURRENT  
EFFICIENCY  
10 kHz - 10 MHz  
25  
76  
50  
35  
80  
50  
35  
81  
50  
mA p-p  
%
T
T
= 25°C  
C
C
BALANCED LOAD  
= -55°C TO +125°C  
8
LOAD FAULT  
POWER DISSIPATION  
8
12  
6
12  
5
12  
W
ms  
1
SHORT CIRCUIT  
RECOVERY  
5.0  
±300  
200  
±400  
300  
5
5.0  
±300  
200  
±400  
300  
5
5.0  
±400  
200  
±500  
300  
5
STEP LOAD RESPONSE  
TRANSIENT  
±150  
±200  
±220  
mV pk  
µs  
9
50% - 100% - 50% ± V  
RECOVERY  
OUT  
1
STEP LINE RESPONSE  
TRANSIENT  
mV pk  
µs  
9
16 - 40 -16 VDC ± V  
RECOVERY  
OUT  
10  
START-UP  
DELAY  
ms  
1
FULL LOAD  
OVERSHOOT  
0
180  
0
150  
0
150  
mV pk  
1
CAPACITIVE LOAD  
NO EFFECT ON DC  
PERFORMANCE  
3000  
3000  
3000  
µF  
T
= 25°C  
C
Notes:  
1. Guaranteed by qualification test and/or analysis. Not an in-line test.  
2. The specified max current is available from either output.  
6. Effect on the negative output under the following conditions:  
+POUT 50%; –POUT 10% to 50%. See “Figure 22” on page 13.  
3. Up to 90% of the total output current/power is available from either output  
providing the positive output is carrying at least 10% of the total output  
power.  
4. Operation is limited below 16 V (see “Figure 23” on page 13).  
5. Effect on the negative output under the following conditions:  
+POUT 20% to 80%; –POUT 80% to 20%.  
7. Tested with 6800 pF ceramic bypass capacitor connected externally from  
input common to case.  
8. Indefinite short circuit protection not guaranteed above 125°C case  
temperature.  
9. Recovery time is measured from application of the transient to point at  
which VOUT is within 1% of final value.  
10. Tested on release from inhibit.  
www.craneae.com/interpoint  
Page 9 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
table 9: electrical characteriSticS:-55°cto +125°c caSe,28vDcvin,100%loaD,Free run,rhao”,unleSS otherWiSe SpeciFieD.  
TRIPLE OUTPUT MODEL – SMTR28512T  
5 (MAIN)  
TYP  
5.00  
±12 (AUXILIARIES)  
UNITS  
VDC  
A
PARAMETER  
CONDITIONS  
MIN  
4.85  
0.3  
MAX  
5.15  
4.0  
MIN  
TYP  
MAX  
OUTPUT VOLTAGE  
OUTPUT CURRENT  
±11.58 12.00 ±12.42  
2
1
0
±0.416 0.625  
V
= 16 to 40 VDC  
MAX. TOTAL AUX  
MAX. TOTAL AUX  
0.834  
in  
2
1
OUTPUT POWER  
= 16 to 40 VDC  
0
20  
0
±5  
7.5  
W
V
10  
in  
OUTPUT RIPPLE  
10 kHz - 2 MHz  
T
T
= 25°C  
16  
10  
30  
28  
40  
4
125  
180  
20  
25  
30  
120  
120  
75  
75  
C
mV p-p  
= -55°C TO +125°C  
C
LINE REGULATION  
LOAD REGULATION  
INPUT VOLTAGE  
V = 16 to 40 VDC  
mV  
mV  
VDC  
V
in  
3, 4  
50  
CONTINUOUS  
TRANSIENT 50 ms  
NO LOAD  
40  
1
50  
INPUT CURRENT  
110  
8
mA  
INHIBITED  
INPUT RIPPLE CURRENT  
EFFICIENCY  
10 kHz - 10 MHz  
72  
70  
45  
73  
80  
mA p-p  
%
T
T
= 25°C  
C
C
= -55°C TO +125°C  
5
LOAD FAULT  
POWER DISSIPATION  
14  
W
ms  
1
ALL OUTPUTS SHORTED  
STEP LOAD RESPONSE  
RECOVERY  
6.0  
±400  
0.30  
±800  
5
6.0  
±1500  
6
6
TRANSIENT  
±150  
0.05  
±500  
3
mV pk  
ms  
7
RECOVERY  
1
STEP LINE RESPONSE  
TRANSIENT  
±800  
5
mV pk  
ms  
7
16 - 40 - 16 V  
RECOVERY  
IN  
8
START-UP  
DELAY  
6.0  
500  
6.0  
ms  
1
OVERSHOOT  
2000  
mV pk  
Notes:  
1. Guaranteed by qualification test and/or analysis. Not an in-line test.  
2. The sum of the two Aux outputs is not to exceed 10 watts. The maximum  
load per Aux output is 7.5 watts.  
3. To maintain regulation when operating the ±Aux at full load, a minimum  
load of 300 mA is required on the main output. For Aux loads less  
than full load, a lower load (<300 mA) on the main output will maintain  
regulation.  
6. Response of each output as all outputs are simultaneously transitioned.  
Main: 50% - 100% - 50% of main full load  
Auxiliaries: 25% - 50% - 25% each, of total auxiliary full load  
7. Recovery time is measured from application of the transient to point at  
which VOUT is within 1% of regulation.  
8. Tested on release from inhibit.  
4. Measured on each output one at a time with the other outputs at full load.  
5. Indefinite short circuit protection not guaranteed above 125°C (case).  
www.craneae.com/interpoint  
Page 10 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
table 10: electricalcharacteriSticS:-55°cto+125°c caSe,28vDcvin,100%loaD,Freerun,rhao”,unleSSotherWiSeSpeciFieD.  
TRIPLE OUTPUT MODEL – SMTR28515T  
5 (MAIN)  
TYP  
5.00  
±15 (AUXILIARIES)  
UNITS  
VDC  
A
PARAMETER  
CONDITIONS  
MIN  
4.85  
0.3  
MAX  
5.15  
4.0  
MIN  
TYP  
15.00  
±0.333  
MAX  
OUTPUT VOLTAGE  
OUTPUT CURRENT  
±14.77  
±15.23  
2
1
0
0.50  
V
= 16 to 40 VDC  
TOTAL  
TOTAL  
0.666  
in  
2
1
OUTPUT POWER  
= 16 to 40 VDC  
0
20  
0
±5  
7.5  
W
V
10  
in  
OUTPUT RIPPLE  
10 kHz - 2 MHz  
T
T
= 25°C  
16  
10  
30  
28  
125  
180  
20  
30  
30  
120  
120  
75  
C
mV p-p  
= -55°C TO +125°C  
C
LINE REGULATION  
LOAD REGULATION  
INPUT VOLTAGE  
V = 16 to 40 VDC  
mV  
mV  
in  
3, 4  
50  
75  
CONTINUOUS  
40  
VDC  
1
TRANSIENT 50 ms  
NO LOAD  
50  
4
50  
110  
6
V
INPUT CURRENT  
mA  
INHIBITED  
INPUT RIPPLE CURRENT  
EFFICIENCY  
10 kHz - 10 MHz  
72  
70  
40  
73  
80  
mA p-p  
%
T
T
= 25°C  
C
C
= -55°C TO +125°C  
5
LOAD FAULT  
POWER DISSIPATION  
14  
W
ms  
1
ALL OUTPUTS SHORTED  
STEP LOAD RESPONSE  
RECOVERY  
6.0  
±400  
0.30  
±800  
5
±1500  
6
6
TRANSIENT  
±150  
0.05  
±500  
2
mV pk  
ms  
7
RECOVERY  
1
STEP LINE RESPONSE  
TRANSIENT  
±800  
5
mV pk  
ms  
7
16 - 40 - 16 V  
RECOVERY  
IN  
8
START-UP  
DELAY  
6.0  
500  
6.0  
ms  
1
OVERSHOOT  
2000  
mV pk  
Notes:  
1. Guaranteed by qualification test and/or analysis. Not an in-line test.  
2. The sum of the two Aux outputs is not to exceed 10 watts. The maximum  
load per Aux output is 7.5 watts.  
3. To maintain regulation when operating the ±Aux at full load, a minimum  
load of 300 mA is required on the main output. For Aux loads less  
than full load, a lower load (<300 mA) on the main output will maintain  
regulation.  
6. Response of each output as all outputs are simultaneously transitioned.  
Main: 50% - 100% - 50% of main full load  
Auxiliaries: 25% - 50% - 25% each, of total auxiliary full load  
7.Recovery time is measured from application of the transient to point at  
which VOUT is within 1% of regulation.  
8. Tested on release from inhibit.  
4. Measured on each output one at a time with the other outputs at full load.  
5. Indefinite short circuit protection not guaranteed above 125°C (case).  
www.craneae.com/interpoint  
Page 11 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
Typical performance ploTs:  
28 V , 25°c T , 100% load, rHa “0”, free run, unless oTHerwise specified.  
in  
c
These are examples for refereꢀce oꢀly aꢀd are ꢀot guaraꢀteed specꢁfꢁcatꢁoꢀs.  
85  
80  
75  
70  
65  
60  
85  
80  
75  
70  
65  
60  
87  
82  
77  
72  
67  
62  
16V  
16V  
16V  
28V  
28V  
28V  
40V  
40V  
40V  
5
10  
15  
20  
25  
30  
5
10  
15  
20  
25  
5
10  
15  
20  
25  
30  
OUTPUT POWER (WATTS)  
SMTR2815S EFFICIENCY  
OUTPUT POWER (WATTS)  
SMTR2805S EFFICIENCY  
OUTPUT POWER (WATTS)  
SMTR2812S EFFICIENCY  
Figure 8  
Figure 7  
Figure 9  
90  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
85  
80  
75  
70  
65  
60  
16V  
16V  
28V  
85  
80  
75  
70  
65  
28V  
40V  
40V  
0.1  
1
10  
100  
FREQUENCY (kHz)  
5
10  
15  
20  
25  
30  
5
10  
15  
20  
25  
30  
AUDIO REJECTION, SMTR SERIES  
SINGLE AND DUAL OUTPUT MODELS  
OUTPUT POWER (WATTS)  
SMTR2815D EFFICIENCY  
OUTPUT POWER (WATTS)  
SMTR2812D EFFICIENCY  
Figure 12  
Figure 10  
Figure 11  
25W to 12.5W  
25W to 2.5W  
V
IN  
2.5W to 25W  
V
OUT  
12.5W to 25W  
50 μs/div  
10% 100%  
50 μs/div  
50% 100%  
50 μs/div  
16 TO 40V  
SMTR2805S STEP LOAD RESPONSE  
SMTR2805S STEP LOAD RESPONSE  
SMTR2805S STEP LINE RESPONSE  
Figure 13  
Figure 14  
Figure 15  
www.craneae.com/interpoint  
Page 12 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
Typical performance ploTs:  
28 V , 25°c T , 100% load, rHa “0”, free run, unless oTHerwise specified.  
in  
c
These are examples for refereꢀce oꢀly aꢀd are ꢀot guaraꢀteed specꢁfꢁcatꢁoꢀs.  
–P  
OUT  
=15W (50%)  
V
IN  
V
IN  
15W to 7.5W  
+V  
OUT  
7.5W to 15W  
V
OUT  
–V  
OUT  
50 μs/div  
25% 50%  
500 µs/div  
50 μs/div  
16 V TO 40 V  
SMTR2805S TURN-ON INTO NO LOAD  
SMTR2815D +V  
STEP LOAD RESPONSE  
SMTR2815D STEP LINE RESPONSE  
OUT  
Figure 16  
Figure 17  
Figure 181  
10  
9
8
7
6
5
4
3
2
1
0
–P  
OUT  
=15W (50%)  
2812D  
2805D  
V
IN  
15W to 3W  
3W to 15W  
2815D  
+V  
OUT  
-1  
-2  
-3  
-4  
-5  
-6  
-7  
-8  
-9  
-10  
2815D  
–V  
OUT  
2812D  
2805D  
+P  
–P  
0
3
6
9
12 15 18 21 24 27 30  
200 µs/div  
50 μs/div  
10% 50%  
OUT  
OUT  
30 27 24 21 18 15 12  
9
6
3
0
SMTR2815D TURN-ON INTO NO LOAD  
OUTPUT LOAD (Watts)  
10% to 90% LOAD +V  
90% to 10% LOAD –V  
CROSS REGULATION  
SMTR2815D +V  
STEP LOAD RESPONSE  
OUT  
Figure 191  
Figure 20  
Figure 211  
8
7
16.0  
15.5  
15.0  
14.5  
14.0  
13.5  
13.0  
80  
16V  
6
5
2812D  
2805D  
75  
70  
65  
60  
55  
4
3
2
COND A  
40V  
1
0
2815D  
–1  
–2  
–3  
–4  
–5  
–6  
–7  
28V  
COND B  
2805D  
2812D  
–8  
10  
5
10  
15  
20  
25  
30  
20  
30  
40  
50  
9
12  
15  
18 21 24  
27 30  
OUTPUT POWER (WATTS)  
SMTR28512T EFFICIENCY  
OUTPUT LOAD (%)  
OUTPUT POWER (WATTS)  
1% DROP  
SMTR SINGLES AND DUALS  
LOW LINE DROPOUT  
COND. B: 50% LOAD +V, 50% to 10% –V  
COND. A: 50% LOAD –V, 50% to 10% +V  
CROSS REGULATION  
Figure 22 1  
Figure 23  
Figure 24  
Notes: 1. Percent (%) of power refers to the percent of the total output power of the converter.  
www.craneae.com/interpoint  
Page 13 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
Typical performance ploTs:  
28 V , 25°c T , 100% load, rHa “0”, free run, unless oTHerwise specified.  
in  
c
These are examples for refereꢀce oꢀly aꢀd are ꢀot guaraꢀteed specꢁfꢁcatꢁoꢀs.  
80  
75  
70  
65  
60  
55  
0
10  
20  
16V  
V
IN  
30  
40V  
40  
50  
+5 V  
OUT  
60  
28V  
+AUX  
70  
80  
90  
–AUX  
100  
0.1  
1
10  
100  
50 µs/div  
16V TO 40V  
FREQUENCY (kHz)  
SMTR SERIES AUDIO REJECTION  
TRIPLE OUTPUT MODELS  
5
10  
15  
20  
25  
30  
SMTR28515T STEP LINE RESPONSE  
OUTPUT POWER (WATTS)  
SMTR28515T EFFICIENCY  
Figure 25  
Figure 26  
Figure 27  
V
V
IN  
IN  
+5 V  
50% to 100%  
50 µs/div  
±15 V  
OUT  
+AUX  
–AUX  
+5 V  
OUT  
1ms/div  
50% to 100%  
500 µs/div  
SMTR28515T, MAIN (+5)  
TURN-ON INTO FULL LOAD  
500 µs/div  
SMTR28515T, AUX. (±15)  
TURN-ON INTO FULL LOAD  
50%  
100%  
SMTR28515T STEP LOAD RESPONSE  
Figure 28  
Figure 29  
Figure 30  
16.0  
15.5  
15.0  
14.5  
14.0  
13.5  
16.0  
15.5  
15.0  
14.5  
14.0  
13.5  
5
10  
15  
20  
25  
30  
5
10  
15  
20  
25  
30  
OUTPUT POWER (WATTS)  
1% DROP  
OUTPUT POWER (WATTS)  
1% DROP  
SMTR28512T  
LOW LINE DROPOUT VS. LOAD  
SMTR28515T  
LOW LINE DROPOUT VS. LOAD  
Figure 31  
Figure 32  
www.craneae.com/interpoint  
Page 14 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
BOTTOM VIEW CASE F1  
Squared corner and dot  
on top of case indicates pin one  
Seam Seal  
1.350 max. (34.29)  
1.170  
(29.72)  
1
2
9
3
8
4
5
6
0.040 dia.  
(1.02)  
10  
7
0.170  
(4.32)  
0.000  
Weight 58 grams max.  
Case dimensions in inches (mm)  
Tolerance ±0.005 (0.13) for three decimal places  
±0.01 (0.3) for two decimal places  
unless otherwise specified  
CAUTION  
Heat from reflow or wave soldering may damage the device.  
Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin.  
Materials  
Header  
Cover  
Pins  
Cold Rolled Steel/Nickel/Gold  
Kovar/Nickel  
#52 alloy/Gold ceramic seal  
Gold plating of 50 - 150 microinches is included in pin diameter  
Seal hole 0.120 ±0.002 (3.05 ± 0.05)  
Case F1 SMTR T, Rev G, 2013.04.18  
Please refer to the numerical dimensions for accuracy.  
Figure 33: caSe F1  
triple output moDelS  
www.craneae.com/interpoint  
Page 15 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
BOTTOM VIEW CASE H2  
Squared corner and dot on top  
of case indicate pin one.  
Seam Seal  
1.115 max. (28.32)  
0.955 (24.26)  
1
2
3
4
7
5
0.040 dia  
(1.02)  
SINGLE  
10  
9
8
6
0.155 (3.94)  
0.000  
Squared corner and dot on top  
of case indicate pin one.  
1.115 max. (28.32)  
0.955 (24.26)  
1
2
3
4
7
5
DUAL  
10  
9
8
6
0.155 (3.94)  
0.000  
Weight 50 grams max.  
Case dimensions in inches (mm)  
Tolerance ±0.005 (0.13) for three decimal places  
±0.01 (0.3) for two decimal places  
unless otherwise specified  
CAUTION  
Heat from reflow or wave soldering may damage the device.  
Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin.  
Materials  
Header  
Cover  
Pins  
Cold Rolled Steel/Nickel/Gold  
Kovar/Nickel  
#52 alloy/Gold ceramic seal  
Gold plating of 50 - 150 microinches is included in pin diameter  
Seal hole 0.120 ±0.002 (3.05 ± 0.05)  
Case H2 SMTR S/D, Rev J, 2013.04.18  
Please refer to the numerical dimensions for accuracy.  
Figure 34: Cases H2  
Single anD Dual output moDelS  
www.craneae.com/interpoint  
Page 16 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
BOTTOM VIEW CASE J1  
Flanged cases: Designator "F" required in Case Option position of model number.  
Sharp corner and dot on top  
of case indicate pin one.  
Seam Seal  
1.350 max. (34.29)  
1.170 (29.72)  
1
2
9
3
8
4
7
5
6
2 x Dia 0.162 ±0.002  
(4.11 ±0.05)  
0.040 dia.  
(1.02)  
2 x R 0.170 (4.32)  
0.670  
(17.02)  
10  
0.170  
(4.32)  
0.000  
(2.720 max (69.09))  
Flange thickness: 0.060 (1.52)  
Weight 62 grams max.  
Case dimensions in inches (mm)  
Tolerance ±0.005 (0.13) for three decimal places  
±0.01 (0.3) for two decimal places  
unless otherwise specified  
CAUTION  
Heat from reflow or wave soldering may damage the device. Solder pins  
individually with heat application not exceeding 300°C for 10 seconds per pin.  
Materials  
Header  
Cover  
Pins  
Cold Rolled Steel/Nickel/Gold  
Kovar/Nickel  
#52 alloy/Gold ceramic seal.  
Gold plating of 50 - 150 microinches is included in pin diameter  
Seal hole 0.120 ±0.002 (3.05 ± 0.05)  
Case J1 SMTR T F, Rev J, 2013.04.18  
Please refer to the numerical dimensions for accuracy.  
Figure 35: caSe J1  
triple output moDelS  
www.craneae.com/interpoint  
Page 17 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
BOTTOM VIEW CASE K3  
Flanged cases: Designator “F” required in Case Option position of model number.  
Dot on top of case indicates pin one  
Seam Seal  
1.115 max. (28.32)  
0.955 (24.26)  
2 x Dia 0.162 ±0.002  
(4.11 ±0.05)  
1
2
3
4
7
5
0.040 dia  
(1.02)  
2 x R 0.170 (4.32)  
SINGLE  
0.555 (14.1)  
10  
9
8
6
0.155 (3.94)  
0.000  
Dot on top of case indicates pin one  
2 x Dia 0.162 ±0.002  
(4.11 ±0.05)  
1
2
3
4
7
5
2 x R 0.170 (4.32)  
DUAL  
10  
9
8
6
(2.910 max (73.91))  
Flange thickness: 0.060 (1.52)  
Weight 52 grams max.  
Case dimensions in inches (mm)  
Tolerance ±0.005 (0.13) for three decimal places  
±0.01 (0.3) for two decimal places  
unless otherwise specified  
CAUTION  
Heat from reflow or wave soldering may damage the device. Solder pins  
individually with heat application not exceeding 300°C for 10 seconds per pin.  
Materials  
Header  
Cover  
Pins  
Cold Rolled Steel/Nickel/Gold  
Kovar/Nickel  
#52 alloy/Gold, ceramic seal  
Gold plating of 50 - 150 microinches is included in pin diameter  
Seal hole 0.120 ±0.002 (3.05 ± 0.05)  
Case K3 SMTR S/D F, Rev H, 2013.04.18  
Please refer to the numerical dimensions for accuracy.  
Figure 36: caSeS K3  
Single anD Dual output moDelS  
www.craneae.com/interpoint  
Page 18 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
DC-DC COnVerterS prOtOtype, ClaSS h anD ClaSS K,  
Mil-prf-38534 eleMent eValuatiOn  
nOn-QMl 1  
QMl  
prOtOtype  
ClaSS h  
/h  
ClaSS K  
/K  
/O  
M/S 2  
n
COMpOnent-leVel teSt perfOrMeD  
Element Electrical  
Visual  
M/S 2  
p 3  
M/S 2  
p 3  
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Internal Visual  
Temperature Cycling  
Constant Acceleration  
Interim Electrical  
Burn-in  
n
n
Post Burn-in Electrical  
Steady State Life  
Voltage Conditioning Aging  
Visual Inspection  
Final Electrical  
n
n
n
n
n
n
n
n
n
n
n
Wire Bond Evaluation  
SEM  
Notes:  
1. Non-QML products may not meet all of the requirements of MIL-PRF-38534.  
2. M/S = Active components (Microcircuit and Semiconductor Die)  
3. P = Passive components, Class H and K element evaluation. Not applicable to Space Prototype (“O”) element evaluation.  
Definitions:  
Element Evaluation: Component testing/screening per MIL-STD-883 as determined by MIL-PRF-38534  
SEM: Scanning Electron Microscopy  
table 11: element evaluation  
www.craneae.com/interpoint  
Page 19 of 20  
SMTR Rev AA - 2013.04.18  
Crane Aerospace & Electronics Power Solutions  
SꢀTR Single, Dual and Triple DC-DC Converters  
28 Volt input – 30 Watt  
DC-DC COnVerterS prOtOtype, ClaSS h anD ClaSS K  
Mil-prf-38534 enVirOnMental SCreening anD rha1 p Or r  
nOn-QMl 2  
prOtOtype  
/OO  
QMl 3  
ClaSS h  
ClaSS K  
teSt perfOrMeD  
/hp  
/hr  
/Kp  
/Kr  
4
4
Non-destruct wire ꢄond pull, ꢀethod 2023  
Pre-cap Inspection, ꢀethod 2017, 2032  
Temperature Cꢅcle (10 times)  
n
n
n
n
n
n
n
n
n
n
n
n
n
Method 1010, Cond. C, -65°C to +150°C, ambient  
Constant Acceleration  
n
n
n
n
Method 2001, 3000 g (Qual 5000 g)  
PIND, Test ꢀethod 2020, Cond. A  
Pre ꢄurn-in test, ꢃroup A, Suꢄgroups 1 and 4  
n
n
n
n
n
n
n
n
n
n
n
n
4
4
4
4
5
burn-in ꢀethod 1015, +125°C case, tꢅpical  
96 hours  
160 hours  
n
n
2 x 160 hours (includes mid-BI test)  
Final Electrical Test, ꢀIꢁ-PRF-38534, ꢃroup A,  
Subgroups 1 and 4: +25°C case  
Subgroups 1 through 6, -55°C, +25°C, +125°C case  
Hermeticitꢅ Test  
n
n
n
n
n
n
n
Gross Leak, Method 1014  
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Fine Leak, Method 1014  
Radiographꢅ, ꢀethod 2012  
Post Radiographꢅ Electrical Test, +25°C case  
Final visual inspection, ꢀethod 2009  
RHA P: 30 ꢆrad(Si) total dose  
RHA R: 100 ꢆrad(Si) total dose  
4
4
n
n
n
n
n
n
n
n
n
n
2
SEE ꢁET 40 ꢀeꢂ-cm /mg  
n
n
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.  
Notes:  
1. Our Redmond facility has a DLA approved RHA plan for Interpoint power  
products. Our SMD products with RHA “P” or “R” code meet DLA requirements.  
2. “OO” prototypes are non-QML products and may not meet all of the requirements  
of MIL-PRF-38534. “O” in the RHA designator position in Interpoint model  
numbers indicates DLA RHA “-” defined as no RHA.  
3. All processes are QML qualified and performed by certified operators.  
4. Not required by DLA but performed to assure product quality.  
5. Burn-in temperature designed to bring the case temperature to +125°C minimum.  
Burn-in is a powered test.  
table 12: environmental Screening anD rha levelS  
SMTR Series Single, Dual and Triple, SMTR Rev AA - 2013.04.18. This revision supersedes all previous releases. All technical information is  
believed to be accurate, but no responsibility is assumed for errors or omissions. Crane Electronics, Inc. reserves the right to make changes in  
products or specifications without notice. Interpoint and SMTR Series are trademarks of Crane Electronics, Inc. Copyright © 1999-2013 Crane  
Electronics, Inc. All rights reserved. www.craneae.com/interpoint  
Page 20 of 20  

相关型号:

5962R0150102KZA

DC to DC Converter
ETC

5962R0150102KZC

Analog Circuit, Hybrid, MDIP10,
CRANE

5962R0151901TXA

IC 2-CH 12-BIT PROPRIETARY METHOD ADC, PARALLEL ACCESS, QFP68, CERAMIC, LCC-68, Analog to Digital Converter
ACTEL

5962R0151901TXX

ADC, Proprietary Method, 12-Bit, 2 Func, 3 Channel, Parallel, Word Access, Bipolar, CERAMIC, LCC-68
ACTEL

5962R01B0102VUB

Field Programmable Gate Array, CMOS, CGA-349
ACTEL

5962R01B0103VUB

Field Programmable Gate Array, CMOS, CGA-349
ACTEL

5962R01B0106V5B

Field Programmable Gate Array, CMOS, CGA-349
ACTEL

5962R01B0107VTB

Field Programmable Gate Array, CMOS, CGA-472
ACTEL

5962R01B0107VUB

Field Programmable Gate Array, CMOS, CGA-349
ACTEL

5962R0250401HXA

DC to DC Converter
ETC

5962R0250401HXC

DC to DC Converter
ETC

5962R0250401KXA

DC to DC Converter
ETC