FEATURES  
• –40°C to +85°C operation  
HR120 SERIES  
12 WATT  
DC/DC CONVERTERS  
28 VOLT NPUT  
• 16 to 40 VDC input  
(19 to 40 VDC input for  
15 volt output models)  
• Fully Isolated  
I
MODELS  
VDC OUTPUT  
• Optocoupler feedback  
• 600 kHz typical operating frequency  
Topology – Single Ended Forward  
• 50 V for up to 50 ms transient protection  
• Inhibit function  
SINGLE  
DUAL  
±12  
5
12  
15  
±15  
• Indefinite short circuit protection  
• Up to 83% efficiency  
Size (max.): 1.460 x 1.130 x 0.330 inches (37.08 x 28.70 x 8.38 mm)  
See Section B8, case E1 for dimensions.  
Weight:  
21 grams typical.  
Screening: Standard only. See Section C2 for screening description.  
DESCRIPTION  
The HR120 Series™ of DC/DC converters offers up to 12 watts of  
power from single or dual outputs in a single package over a –40°C  
to +85°C temperature range. Thick film hybrid manufacturing tech-  
nology produces high levels of miniaturization, giving the HR120  
Series converters a low profile (0.330 inch), small board area (1.65  
Indefinite short circuit protection and overload protection are  
provided by sensing output load current and restricting the output  
current to approximately 125% of full load output current. Since the  
output current is sensed in the secondary stage, the result is a  
predictable, constant output current control with no foldback char-  
acteristics. HR120 converters are provided with internal filtering  
elements on both the input and output to help reduce the need for  
external components.  
3
square inches), and high power density (22 watt/in ).  
The parts are packaged in sealed steel enclosures, making them  
ideal for use in high reliability applications. Each unit is guaranteed  
to pass a hermeticity test with a maximum leak rate of 0.001 atm-  
cc/sec.  
WIDE VOLTAGE RANGE  
The 5 and 12 volt output models provide full power operation over  
the input voltage range of 16 to 40 volts (19 to 40 volts for 15 volt  
output models). Operation below 16 volts (or below 19 volts for the  
15 volt output models), including operation in MIL-STD-704E emer-  
gency power conditions, is possible with derated output power.  
Please refer to the low voltage drop-out graphs, Figures 9 and 10.  
DESIGN METHODOLOGY  
The HR120 converters are switching regulators which use a quasi-  
square wave, single ended forward converter design with a nominal  
switching frequency of 600 kHz. Isolation between input and output  
circuits is provided with a transformer in the forward power loop and  
a temperature insensitive optical link in the feedback control loop.  
Output regulation is accomplished with constant frequency pulse  
width modulation. Both line and load regulation are typically within  
10 mV.  
The HR120 Series provides full power operation at case tempera-  
tures from –40°C up to +85°C. Depending on operating levels, air  
flow, and ambient temperature, heat sinking may be required.  
INHIBIT FEATURE  
On dual output models, the positive output is independently regu-  
lated and the negative output is cross-regulated. Figures 7 and 8  
illustrate what effects load changes have on the negative output.  
An inhibit terminal is provided that can be used to disable internal  
switching, resulting in a very low quiescent input current. An open  
collector TTL compatible low (0.8 V) is required to control the  
inhibit function. This level may be supplied by an open collector gate  
since the inhibit pin is provided with an internal pull-up resistor.  
B4-47  
HR120 SERIES  
12 WATT  
DC/DC CONVERTERS  
INHIBIT  
TYPICAL CHARACTERISTICS  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage  
Inhibit TTL Open Collector  
• Logic low (output disabled)  
Logic low 0.8 V max  
Output Voltage Temperature Coefficient  
• 150 ppm/°C, typical  
Input to Output Capacitance  
• 50 pF, typical  
Current Limit  
• 125% of full load, typical  
Isolation  
• 16 to 40 VDC  
• 19 to 40 VDC 15 volt outputs  
Output Power  
• 12 watts (10 watts HR121-2805)  
Lead Soldering Temperature (10 sec per pin)  
• 300°C  
Inhibit pin current 4 mA max  
Referenced to input common  
• Logic high (output enabled)  
Open collector  
Storage Temperature Range (Case)  
• –55°C to +125°C  
• 100 megohm minimum at 500 V  
Conversion Frequency  
• 600 kHz typical  
Inhibit Pin Voltage (unit enabled)  
• 8 to 11 V  
RECOMMENDED OPERATING CONDITIONS  
Input Voltage Range  
• 16 to 40 VDC continuous  
• 19 to 40 VDC continuous 15 volt outputs  
• 50 V for 50 msec transient  
Case Operating Temperature (Tc)  
• –40°C to +85°C full power  
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.  
SINGLE OUTPUT MODELS  
PARAMETER  
HR121-2805  
HR121-2812  
TYP MAX  
HR121-2815  
TYP MAX  
CONDITIONS  
MIN  
4.95  
TYP  
5.0  
MAX  
MIN  
11.88  
MIN  
14.85  
UNITS  
VDC  
A
OUTPUT VOLTAGE  
OUTPUT CURRENT  
OUTPUT POWER  
OUTPUT RIPPLE  
5.05  
2.0  
10  
60  
50  
50  
40  
50  
30  
478  
3
12  
30  
10  
10  
28  
20  
2
12.12  
1.0  
12  
15  
25  
10  
10  
28  
20  
2
15.15  
0.8  
12  
MIN. TO MAX. V  
W
IN  
10 kHz to 2 MHz  
MIN. TO MAX. V  
40  
10  
10  
28  
60  
50  
mV p-p  
mV  
LINE REGULATION  
LOAD REGULATION  
INPUT VOLTAGE  
50  
50  
IN  
NO LOAD TO FULL  
NO LOAD TO FULL  
TRANSIENT 50 ms  
NO LOAD  
50  
50  
mV  
16  
16  
40  
19  
40  
VDC  
mA  
50  
50  
INPUT CURRENT  
20  
30  
30  
FULL LOAD  
548  
3
535  
3
INHIBITED  
2
INPUT RIPPLE  
CURRENT  
10 kHz TO 2 MHz  
135  
77  
180  
150  
81  
200  
150  
83  
220  
mA p-p  
%
EFFICIENCY  
74  
77  
80  
1
LOAD FAULT  
POWER DISSIPATION  
OVERLOAD  
5
80  
5
5
2
W
SHORT CIRCUIT  
DELAY  
3.5  
300  
2.8  
200  
START-UP  
Notes  
180  
150  
250  
ms  
1. Indefinite short circuit protection not guaranteed above 85°C case temperature.  
B4-48  
HR120 SERIES  
12 WATT  
DC/DC CONVERTERS  
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.  
DUAL OUTPUT MODELS  
PARAMETER  
HR122-2812  
TYP  
HR122-2815  
CONDITION  
MIN  
11.88  
11.82  
MAX  
MIN  
14.85  
14.77  
TYP  
15.0  
15.0  
0.4  
MAX  
UNITS  
OUTPUT VOLTAGE  
+V  
12.0  
12.0  
0.5  
12.12  
12.18  
1.0  
15.15  
15.23  
0.8  
OUT  
VDC  
– V  
OUT  
1, 2  
OUTPUT CURRENT  
A
2
OUTPUT POWER  
+V  
10.8  
10.8  
12  
10.8  
10.8  
12  
OUT  
– V  
W
OUT  
TOTAL  
OUTPUT RIPPLE  
VOLTAGE  
10 kHz TO 2 MHz  
16  
30  
5
60  
50  
150  
50  
150  
10  
5
19  
30  
5
60  
50  
150  
50  
150  
8
mV p-p  
mV  
LINE REGULATION  
+V  
OUT  
MIN. TO MAX. V  
IN  
– V  
30  
5
30  
10  
30  
4
OUT  
LOAD REGULATION  
NO LOAD TO FULL  
CROSS REGULATION  
+V  
OUT  
mV  
%
– V  
30  
5
OUT  
3
20% TO 80% LOAD  
4
50% LOAD  
4
3
5
INPUT VOLTAGE  
INPUT CURRENT  
CONTINUOUS  
28  
40  
50  
28  
40  
50  
VDC  
TRANSIENT 50 ms  
NO LOAD  
FULL LOAD  
INHIBITED  
25  
35  
545  
3
25  
35  
540  
3
mA  
1.9  
1.9  
INPUT RIPPLE  
CURRENT  
10 kHz TO 2 MHz  
175  
81  
240  
175  
83  
240  
mA p-p  
%
EFFICIENCY  
78  
80  
5
LOAD FAULT  
POWER DISSIPATION  
OVERLOAD  
2.8  
5
2
5
W
SHORT CIRCUIT  
DELAY  
START-UP  
150  
250  
150  
250  
ms  
Notes  
1. Applies to both outputs.  
2. Maximum combined output power is 12 watts. A maximum of 90% is available from either output.  
3. 20% to 80% load on the positive output and 80% to 20% on the negative output. See Figure 8.  
4. 50% load on the positive output and 50% to 20% load on the negative output. 50% load on the negative output and  
50% to 20% load on the positive output. See Figure 7.  
5. Indefinite short circuit protection not guaranteed above 85°C case temperature.  
PIN OUT  
Squared corner and dot on  
top of cover indicate pin one.  
Pin  
1
Single Output  
Inhibit  
Dual Output  
Inhibit  
MODEL NUMBER KEY  
HR12  
2 - 28 12  
Base Model  
2
No connection  
Positive Output  
Number of Outputs  
(1 = single, 2 = dual)  
1
8
2
3
4
5
6
3
Output Common Output Common  
4
Positive Output  
No connection  
Case Ground  
Input Common  
Positive Input  
Negative Output  
No connection  
Case Ground  
Input Common  
Positive Input  
Input Voltage  
BOTTOM VIEW  
HR120  
5
6
Output Voltage  
7
7
8
See Section B8, case E1, for dimensions  
FIGURE 1: PIN OUT  
B4-49  
HR120 SERIES  
12 WATT  
DC/DC CONVERTERS  
Typical Performance Curves: 25°C Tc , 28 VDC Vin, 100% load, unless otherwise specified.  
90  
80  
70  
60  
50  
90  
80  
70  
60  
50  
90  
80  
70  
60  
50  
16V  
19V  
16V  
40V  
40V  
28V  
40V  
28V  
28V  
10  
2
4
6
8
10 12 14  
2
6
8
12  
14  
4
2
4
6
8
10 12 14  
Output Power (Watts)  
HR121-2805 Efficiency  
FIGURE 2  
Output Power (Watts)  
HR121-2812 Efficiency  
FIGURE 3  
Output Power (Watts)  
HR121-2815 Efficiency  
FIGURE 4  
10  
8
90  
80  
70  
60  
50  
90  
80  
70  
60  
50  
19V  
16V  
6
Cond. A  
2812  
4
40V  
40V  
2
2815  
0
2
28V  
28V  
–4  
–6  
–8  
–10  
2812  
Cond. B  
0
10  
2
30  
40  
50  
2
4
6
8
10 12 14  
2
4
6
8
10 12 14  
Output Load (%)  
Output Power (Watts)  
Output Power (Watts)  
Condition A: 50% Load Pos. Vout, 50% to 20% Neg. Vout  
Condition B: 50% Load Neg. Vout, 50% to 20% Pos. Vout  
HR122 Negative Output Voltage  
HR122-2815 Efficiency  
HR122-2812 Efficiency  
Cross Regulation  
FIGURE 5  
FIGURE 6  
FIGURE 7  
20  
15  
19  
18  
19  
18  
17  
16  
15  
14  
13  
12  
11  
10  
2815  
17  
2815  
16  
5
0
15  
14  
2815  
2812  
2805  
–5  
2812  
–10  
–15  
–20  
13  
2812  
12  
11  
0
20  
40  
60  
80  
100  
2
4
6
8
10 12 14  
2
4
6
8
10 12 14  
Output Load (%)  
Output Power (Watts)  
50 mV Drop  
HR122 Low Line Dropout  
Output Power (Watts)  
50 mV Drop  
HR121 Low Line Dropout  
Positive Output 20% to 80% Load  
Negative Output 80% to 20% Load  
HR122 Negative Output Voltage  
Cross Regulation  
FIGURE 8  
FIGURE 9  
FIGURE 10  
21821-009-DTS Rev A  
DQ# 2011  
All technical information is believed to be accurate, but no responsibility is assumed  
for errors or omissions. Interpoint reserves the right to make changes in products  
B4-50  
or specifications without notice. HR120 Series is  
a trademark of Interpoint.  
Copyright © 1994 - 1999 Interpoint. All rights reserved.  
CASE E  
CASES  
Squared corner and dot on top  
of case indicate pin one.  
Materials  
Header Cold Rolled Steel/Nickel/Gold  
Cover Kovar/Nickel  
(SMHF Series  
CASE E  
Cold Rolled Steel/Nickel/Gold)  
#52 alloy/Gold  
compression glass seal  
BOTTOM VIEW  
See Figures 16 – 18  
for pin configurations.  
Pins  
1.130 max  
(28.70)  
Case dimensions in inches (mm)  
Tolerance ±0.005 (0.13) for three decimal places  
±0.01 (0.3) for two decimal places  
unless otherwise specified  
1.460 max  
(37.08)  
CAUTION  
Heat from reflow or wave soldering may damage  
the device. Solder pins individually with heat  
application not exceeding 300°C for 10 seconds  
per pin.  
FIGURE 15: CASE E MAXIMUM DIMENSIONS  
BOTTOM VIEW CASE E1  
MHF+ Series Single and Dual: Screening – Standard, ES, or 883  
MHF Series and LIM5050 Module: Screening – Standard or ES  
SMHF Series Single and Dual and SLIM5050 Module:  
Screening – Space Standard, H, or K  
HR120 Series: No screening options  
Projection Weld  
Seam Seal  
Squared corner and dot on top  
of case indicate pin one.  
0.960  
(24.38)  
1
2
3
4
5
0.030 dia.  
(0.76)  
8
7
6
0.160  
(4.06)  
0.000  
FIGURE 16: CASE E1  
Note: Although every effort has been made to render the case drawings at actual size, variations in the printing process may cause some distortion. Please refer  
to the numerical dimensions for accuracy.  
B8-10  
QA SCREENING  
HR PRODUCTS  
HR PRODUCTS  
TEST (HR products)  
PRE-CAP INSPECTION  
Method 2017  
STANDARD  
yes  
yes  
yes  
yes  
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A  
Subgroups 1 and 4: +25°C case  
HERMETICITY TESTING  
-3  
Gross Leak, Dip (1 x 10 )  
FINAL VISUAL INSPECTION  
Method 2009  
Test methods are referenced to MIL-STD-883 as determined by MIL-  
PRF-38534.  
Applies to the following products:  
HR700 Series  
HR300 Series  
HR150 Series  
HR120 Series  
HR40 Series  
C2-13  

相关型号:

HR122-2815

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

HR122-28L15

2-OUTPUT 12W DC-DC REG PWR SUPPLY MODULE, 0.325 INCH HEIGHT, HERMETIC SEALED, METAL, PACKAGE-8
CRANE

HR1221W

specially designed for high efficient discharge application
CSB-BATTERY

HR1221W_16

specially designed for high efficient discharge application
CSB-BATTERY

HR1221W_17

Valve Regulated Lead Acid Battery
CSB-BATTERY

HR1224W

specially designed for high efficient discharge application
CSB-BATTERY

HR1224W_16

Cells Per Unit 6 Voltage Per Unit 12
CSB-BATTERY

HR1224W_17

Valve Regulated Lead Acid Battery
CSB-BATTERY

HR1227W

specially designed for high efficient discharge application
CSB-BATTERY

HR1227W_16

Cells Per Unit 6 Voltage Per Unit 12
CSB-BATTERY

HR1227W_17

Valve Regulated Lead Acid Battery
CSB-BATTERY

HR1234W

specially designed for high efficient discharge application
CSB-BATTERY