MDCA/05S/05D 概述
Analog Circuit
MDCA/05S/05D 数据手册
通过下载MDCA/05S/05D数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载FEATURES
MDC SERIES
UP TO 60 WATTS
MULTIPLE OUTPUT (2-8),
FACTORY CONFIGURABLE
DC/DC CONVERTERS
28 VOLT INPUT
• –55° to +100°C operation
• 16 to 40 VDC input
• Two to eight outputs
* Fully Isolated
• 50 V for up to 50 ms transient
protection
• Inhibit function
• Sync function available on
select modules
VDC OUTPUT
Mix or match volt-
ages and power to
configure from two
to eight outputs.
• Sense available on select
single output modules
• Short circuit protection
Size (max):MDCG-H 3.005 x 1.505 x 0.400 inches (76.33 x 38.23 x 10.16 mm)
MDCA-F 3.005 x 2.260 x 0.400 inches (76.33 x 57.40 x 10.16 mm)
Weight:
MDCG-H 100 grams maximum
MDCA-F 150 grams maximum
Screening: Standard or ES
Description
Features
Interpoint’s MDC Series™ of DC/DC converters offers a unique
product by effectively combining two, three, or four individual
modular DC/DC converters to provide more than one hundred
combinations. The modules are established high-reliability military
aerospace DC/DC converters with input voltages of 16 to 40 VDC
and a typical transient rating of 50 V for 50 milliseconds. All modules
operate from no-load to full load and provide a constant current limit
at each output.
All converters have an inhibit function. Remote sense and trim up to
0.6V is available on the 30 watt single modules. The 15 watt and 30
watt choices have synchronization - if two are used, the synchro-
nization functions are combined internally.
Table 1: Modules – Power and Vout
Power
Vout Features
3.3 Inhibit &
Sync &
Power
5 Watt
Vout Features
30 Watt
5
Inhibit
5
5.2
12
15
18
5
12
15
Sense/
Trim up
12
15
5
12
15
Inhibit &
Sync
15 Watt
3.3 Inhibit &
1.5 Watt
3.3 Inhibit
5
Sync
5
5.2
5.2
12
12
15
28
5
12
15
15
5
12
15
1
MDC SERIES
UP TO 60 WATTS
FACTORY CONFIGURABLE DC/DC CONVERTERS
Table 2: Configurations
Case Size: 3.005 x 2.260 x 0.400 inches (76.33 x 57.40 x 10.16 mm
Configuration
Resulting
Module Power (Watts)
1
Selection Letter
Output Power (W)
30
2
15
0
5
0
0
2
0
2
4
1.5
0
A
B
C
D
E
F
60
45
40
33
26
20
1
1
1
1
0
0
0
2
2
0
1
1
0
0
0
1. Case has eighteen pins which may limit the number of output voltages available.
Case Size: 3. 005 x 1.505 x 0.400 inches (76.33 x 38.23 x 10.16 mm)
Configuration
Resulting
Module Power (Watts)
2
Selection Letter
Output Power (W)
30
0
15
2
5
0
1
1.5
0
G
H
30
8
0
0
2
2. Case has twelve pins which may limit the number of output voltages available.
Selecting a configuration:
Begin with the base model letters - MDC. Add a
configuration letter from “Table 2: Configurations”
that matches the number of outputs and power
level you require. Using “Table 1: Modules” from
page 1, choose from the available voltages in the
power levels determined by the configuration letter.
Add the chosen voltages to the model and configu-
ration letters beginning with the highest wattage
down to the lowest.
More Examples:
MDCD/15D/12S/5S/5S
33 watt total, five outputs:
15 watt dual 15 volt, 15 watt single 12 volt, 1.5 watt
single 5 volt, 1.5 watt single 5 volt
MDCB/3.3S/5D/12D
45 watt total, five outputs: 30 watt single 3.3 volt, 15
watt dual 5 volt, 1.5 watt dual 12 volt
As an example: To configure a four output, 45 watt,
converter begin with MDCB. Choose the output
voltages for the 30 watt, 15 watt, and 1.5 watt
modules in Table 2. For this example a 30 watt 5
volt dual output, a 15 watt 28 volt single output, and
a 1.5 watt 12 volt output were selected. The
resulting configuration is MDCB/05D/28S/12S.
Note: The specifications on the following pages are for the individual modules. The specifications/perform-
ance of the configured converter may vary from the specifications in the “Electrical Characteristics” tables.
Please contact the factory for details.
2
MDC SERIES
UP TO 60 WATTS
FACTORY CONFIGURABLE DC/DC CONVERTERS
Block Diagrams: Examples of Configurations
Inh
Vin
+S
+V
+Sense 1
+V1
Inhibit 1
Vin
30 Watt
In Com
Sync In
Ret
Return 1
Return
–S
–Sense 1
Sync 1
Sync 2
Case
Inh
Vin
+S
+V
+Sense 1
+V1
30 Watt
In Com
Sync In
Ret
Return 1
Inhibit 2
–S
–Sense 1
Case Size: 3.005 x 2.260 x 0.400
Figure 1: MDCA – 60 watts, 2 outputs
Vin
Vin
Rtn
Inh
+V
Ret
–V
+V1
5 Watt
5 Watt
5 Watt
5 Watt
Return
Return 1
–V1
Inhibit 1
+V2
Vin
Rtn
Inh
+V
Ret
–V
Return 2
–V2
Inhibit 2
Inhibit 3
Inhibit 4
+V3
Vin
Rtn
Inh
+V
Ret
–V
Return 3
–V3
+V4
Vin
Rtn
Inh
+V
Ret
–V
Return 4
–V4s
Case Size: 3.005 x 2.260 x 0.400
Figure 2: MDCF – 20 watts, 8 outputs
3
MDC SERIES
FACTORY CONFIGURABLE DC/DC CONVERTERS
UP TO 60 WATTS
30 Watt Single Output Modules
ABSOLUTE MAXIMUM RATINGS
SYNC AND INHIBIT
TYPICAL CHARACTERISTICS
Sync (500 to 675 kHz)
• Duty cycle 40% min, 60% max
• Logic low 0.8 V max
• Logic high 4.5 V min, 5 V max
• Referenced to input common
• If not used, connect to input common
Inhibit TTL Open Collector
• Logic low (output disabled)
Voltage ≤0.8 V
Input Voltage
• 16 to 40 VDC
Output Power
• 25 to 30 watts depending on model
Lead Soldering Temperature (10 sec per pin)
• 300°C
Storage Temperature Range (Case)
• –65°C to +135°C
Output Voltage Temperature Coefficient
• 100 ppm/°C typical single and dual outputs
• 200 ppm/°C main, 300 ppm/°C aux
triple output
Input to Output Capacitance
• 50 pF typ. (100 pF typ triple outputs)
Current Limit
• 115% of full load typical
Isolation
Inhibit pin current 8.0 mA max
• Referenced to input common
• Logic high (output enabled)
Open collector
• 100 megohm minimum at 500 V
Audio Rejection
• 40 dB typ (50 dB typ triple output)l
Conversion Frequency
• Free run 550 min, 600 typ, 650 max kHz
• External sync 500 to 675 kHz
Inhibit Pin Voltage (unit enabled)
• 9 to 11 V
RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
• 16 to 40 VDC continuous
• 50 V for 50 msec transient
Case Operating Temperature (Tc)
• –55°C to +100°C full power
• –55°C to +115°C absolute
Derating Output Power/Current
• Linearly from 100% at 100°C to 0% at 115°C
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODULES
3R3S
05S
12S
15S
18S
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT
CONDITION
MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
3.27 3.30 3.33 4.95 5.00 5.05 11.88 12.00 12.12 14.85 15.00 15.15 17.82 18.00 18.18 VDC
1
V
V
= 16 to 40 VDC
= 16 to 40 VDC
0
0
––
—
6.06
20
0
0
—
—
5.0
25
0
0
—
—
2.5
30
0
0
—
—
2.0
30
0
0
—
—
1.67
30
A
IN
1
OUTPUT POWER
W
IN
OUTPUT RIPPLE
VOLTAGE
10 kHz – 2 MHz
—
—
—
—
—
—
16
—
15
—
5
40
50
10
10
10
10
40
50
—
—
—
—
—
—
16
—
35
50
10
15
5
50
90
30
50
30
50
40
50
—
—
—
—
—
—
16
—
25
40
10
15
5
50
90
30
50
30
50
40
50
—
—
—
—
—
—
16
—
25
40
10
15
5
50
90
30
50
30
50
40
50
—
—
—
—
—
—
16
—
—
—
—
—
—
—
28
—
40
90
30
50
30
50
40
50
mV p-p
mV
Tc = –55°C TO +125°C
Vin = 16 to 40 VDC
Tc = –55°C TO +125°C
NO LOAD TO FULL
Tc = –55°C TO +125°C
CONTINUOUS
2
LINE REGULATION
—
2
LOAD REGULATION
mV
—
28
—
15
28
—
15
28
—
15
28
—
1
INPUT VOLTAGE
VDC
V
NO LOAD TO FULL
TRANSIENT 50 ms
1
INPUT CURRENT
NO LOAD
FULL LOAD
—
—
—
30
0.94
7
75
—
8
—
—
—
35
1.15
3
75
—
8
—
—
—
35
1.30
3
75
—
8
—
—
—
35
1.25
3
75
—
8
—
—
—
—
1.33
—
50
—
8
mA
A
INHIBITED
mA
INPUT RIPPLE
CURRENT
10 kHz – 10 MHz
Tc = –55°C TO +125°C
—
25
76
50
—
20
78
50
—
20
83
50
—
20
84
50
—
—
—
50 mA p-p
EFFICIENCY
74
—
76
—
80
—
81
—
81
—
%
3
LOAD FAULT
SHORT CIRCUIT
POWER DISSIPATION
—
—
—
10
6
—
—
—
10
5
—
—
—
10
5
—
—
—
10
5
—
—
—
10
W
1, 4
RECOVERY
1.4
1.4
1.4
1.4
1.4
—
ms
STEP LOAD RESP.
STEP LINE RESP.
50% – 100% – 50%
TRANSIENT
—
—
125
250
200
—
—
200 300
60 200
—
—
250 400
60 200
—
—
350 500
60 200
—
—
—
600 mV pk
4
RECOVERY
—
60
—
µs
16 – 40 – 16 VDC
5
TRANSIENT
—
—
—
—
300
300
—
—
200 300
—
—
400 500
—
—
500 600
—
—
500
300
—
—
mV pk
µs
4
RECOVERY
—
300
5
—
300
5
—
300
5
1
START-UP
DELAY
—
1.4
5
—
1.4
—
1.4
—
1.4
—
—
5
ms
OVERSHOOT
FULL LOAD
NO LOAD
—
—
0
50
—
—
0
50
—
—
0
120
—
—
0
150
—
—
0
—
—
mV pk
33
150
50
250
120 600
150 750
—
Notes
1. Tc = –55°C to +100°C
2. Operation is limited below 16V.
4. Recovery time is measured from application of the transient to point at which
Vout is within 1% of final value.
3. Indefinite short circuit protection not guaranteed above 100°C case.
5. Transition time ≥10 µs.
4
MDC SERIES
UP TO 60 WATTS
FACTORY CONFIGURABLE DC/DC CONVERTERS
30 Watt Dual Output Modules
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL OUTPUT MODULES
PARAMETER
OUTPUT VOLTAGE
05D
TYP
5.00
12D
TYP
15D
TYP
CONDITIONS
MIN
4.95
MAX
MIN
MAX
MIN
MAX
UNITS
+V
5.05 11.88 12.00 12.12 14.85 15.00 15.15
OUT
VDC
–V
4.92
0
5.00
2.5
—
20
40
10
50
10
50
5
5.07 11.82 12.00 12.18 14.77 15.00 15.23
OUT
1, 2
OUTPUT CURRENT
V
V
= 16 TO 40 VDC
= 16 TO 40 VDC
4.5
25
50
80
50
100
50
100
30
50
50
100
12
6
0
1.25
—
30
40
10
50
10
50
15
30
15
30
4
2.25
30
0
1.0
—
25
40
10
50
10
50
15
30
15
30
3
1.8
30
A
IN
1, 2
OUTPUT POWER
0
0
0
W
IN
OUTPUT RIPPLE
10 kHz - 2 MHz
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
80
—
—
—
—
—
—
—
—
—
—
—
—
80
mV p-p
mV
VOLTAGE +/– V
Tc = –55°C TO +125°C
120
30
120
30
OUT
3
LINE REGULATION
+V
OUT
V
= 16 TO 40 VDC
–V
+V
–V
+V
–V
+V
–V
120
50
150
50
IN
OUT
OUT
OUT
OUT
OUT
OUT
OUT
Tc = –55°C
TO +125°C
150
30
180
30
LOAD REGULATION
NO LOAD TO FULL
25
5
120
50
150
50
mV
%
Tc = –55°C
TO +125°C
25
7
180
8.3
6
180
8
CROSS REGULATION
SEE NOTE 4
SEE NOTE 5
EFFECT ON –V
4
4
4
6
OUT
1
INPUT VOLTAGE
CONTINUOUS
TRANSIENT 50 ms
NO LOAD
16
0
28
—
40
50
75
—
8
16
0
28
—
40
50
75
—
8
16
0
28
—
40
50
75
—
8
VDC
V
NO LOAD TO FULL
INPUT CURRENT
—
—
—
35
—
—
—
50
—
—
—
50
mA
A
FULL LOAD
1.10
3
1.34
3
1.29
3
INHIBITED
mA
INPUT RIPPLE
1
CURRENT
10 kHz - 10 MHz
—
15
78
50
—
20
81
50
—
20
83
50
mA p-p
%
EFFICIENCY
76
—
78
—
80
—
6
LOAD FAULT
POWER DISSIPATION
1
SHORT CIRCUIT
—
—
—
10
—
—
—
10
—
—
—
10
W
RECOVERY
50 – 100 – 50% BALANCED
TRANSIENT
1.4
5.0
1.4
5.0
1.4
5.0
ms
STEP LOAD
RESPONSE
V
—
—
200
100
300
200
—
—
150
100
300
200
—
—
200
100
400
200
mV pk
µs
OUT
7
RECOVERY
STEP LINE
RESPONSE
16 – 40 – 16 V
IN
8
V
TRANSIENT
—
200
400
—
200
400
—
400
500
mV pk
OUT
7
RECOVERY
—
—
—
300
5
—
—
—
300
5
—
—
—
300
5
µs
1
START–UP
DELAY
1.4
1.4
1.4
ms
OVERSHOOT
FULL LOAD
NO LOAD
—
—
0
50
—
—
0
120
600
—
—
0
150
750
mV pk
50
250
120
150
Notes
1.Tc = –55°C to +100°C.
5. Effect on the negative output under the following conditions:
+P 50%; –P 10% to 50%
out
out
2. Up to 90% of the total output current/power is available from either output
providing the positive output is carrying at least 10% of the total output
power.
6. Indefinite short circuit protection not guaranteed above 100°C case.
7. Recovery time is measured from application of the transient to point at which
Vout is within 1% of final value.
3. Operation
is
limited
below
16
V
(see
Figure
21).
8. Transition time ≥ 10 µs.
+P 20% to 80%; –P 80% to 20%
out out
5
MDC SERIES
UP TO 60 WATTS
FACTORY CONFIGURABLE DC/DC CONVERTERS
15 Watt Single Output Modules
ABSOLUTE MAXIMUM RATINGS
SYNC AND INHIBIT
TYPICAL CHARACTERISTICS
Input Voltage
• 16 to 40 VDC
Power Dissipation (Pd)
• 6 W
Output Power
• 12 to 15 watts depending on model
Lead Soldering Temperature (10 sec per lead)
• 300°C
Storage Temperature Range (Case)
• –65°C to +150°C
Sync In (500 to 600 kHz)
• Duty cycle 40% to 60%
• Logic low 0.8 V max
Output Voltage Temperature Coefficient
• 100 ppm /°C typical
• 150 ppm/°C maximum
Input to Output Capacitance
• 60 pF typical
Undervoltage Lockout
• 12 V input typical
Current Limit
• 115% of full load typical
Isolation
• 100 megohm minimum at 500 V
Audio Rejection
• Logic high 4.5 V min, 5 V max
• Referenced to input common
• If not used, connect to input common
Inhibit TTL Open Collector
• Logic low (output disabled)
Logic low voltage ≤0.8 V max
Inhibit pin current 4.0 mA max
• Referenced to input common
• Logic high (output enabled)
Open collector or unconnected
RECOMMENDED OPERATING CONDITIONS
• 50 dB typical
Input Voltage Range
• 16 to 40 VDC continuous
• 0 V for up to 50 msec transient
Case Operating Temperature (Tc)
• –55°C to +100°C full power
Conversion Frequency (º55°C to +100°C Tc)
• Free run 550 kHz typical
480 kHz min, 620 kHz max
Inhibit Pin Voltage (unit enabled)
• 8.5 to 12 V
• –55°C to +115°C absolute
Derating Output Power/Current (Tc)
• Linearly from 100% at 100°C to 0% at 115°C
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODULES
3R3S
05S
5R2S
PARAMETER
CONDITION
MIN TYP MAX
MIN TYP MAX
MIN TYP MAX
UNITS
VDC
A
OUTPUT VOLTAGE
3.27 3.30 3.33
4.95 5.00 5.05
5.16 5.20 5.24
OUTPUT CURRENT
OUTPUT POWER
V
V
= 16 to 40 VDC
= 16 to 40 VDC
0
0
—
—
2.4
8
0
0
—
—
2.4
12
0
0
—
—
2.4
IN
IN
12.48
W
OUTPUT RIPPLE
VOLTAGE
10 kHz - 2 MHz
—
—
—
—
16
—
30
50
5
80
120
100
50
—
—
—
—
16
—
30
60
5
80
100
50
—
—
—
—
16
—
30
60
5
50
100
35
mV p-p
Tc = –55°C to +100°C
Vin = 16 to 40 VDC
NO LOAD TO FULL
CONTINUOUS
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
mV
mV
VDC
V
20
28
—
20
28
—
50
20
28
—
35
40
40
40
TRANSIENT 50 ms
50
50
50
INPUT CURRENT
NO LOAD
FULL LOAD
—
—
—
—
—
72
25
—
5
65
397
12
—
—
—
—
—
75
25
40
—
—
—
—
—
75
25
42
560 624
560 605
mA
INHIBITED
5
12
80
5
12
100
120
—
INPUT RIPPLE
CURRENT
10 kHz - 10 MHz
Tc = –55°C to +100°C
45
—
75
80
35
—
77
35
—
77
mA pp
%
120
—
100
—
EFFICIENCY
1
LOAD FAULT
SHORT CIRCUIT
POWER DISSIPATION
—
—
5
8
—
—
3.5
7.5
6
—
—
.35
7.5
6
W
2
RECOVERY
7.5
30
30
30
ms
STEP LOAD RESP.
STEP LINE RESP.
START-UP
50% – 100% – 50%
TRANSIENT
–400 150 500
150 300
–400 150 400
150 300
–400 150 400
150 300
mV pk
µs
2
RECOVERY
—
—
—
16 – 40 – 40 VDC
3
TRANSIENT
–800 550 800
–800 550 800
–800 550 800
mV pk
ms
2
RECOVERY
—
—
0
0.8
10
1.2
25
—
0
0.8
10
1.2
25
—
0
0.8
10
1.2
18
DELAY
ms
4
OVERSHOOT
200 300
0
100 600
0
100 300
mV pk
Notes
1. MHF+285R2S specifications are at 25°Tc only, contact your Interpoint
representative for more information on over temperature specs.
2. Indefinite short circuit protection not guaranteed above 100°C (case)
3. Recovery time is measured from application of the transient to point at
which Vout is within regulation.
4. Input step transition time >10µs.
5. Input step transition time <100µs.
6
MDC SERIES
UP TO 60 WATTS
FACTORY CONFIGURABLE DC/DC CONVERTERS
15 Watt Single Output Modules
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODULES
12S
15S
28S
PARAMETER
CONDITION
MIN TYP MAX
MIN TYP MAX
MIN TYP MAX
UNITS
VDC
A
OUTPUT VOLTAGE
11.88 12.00 12.12
14.85 15.00 15.15
27.72 28.00 28.28
OUTPUT CURRENT
OUTPUT POWER
V
V
= 16 to 40 VDC
= 16 to 40 VDC
0
0
—
—
1.25
15
0
0
—
—
1.00
15
0
0
—
—
0.54
15
IN
IN
W
OUTPUT RIPPLE
VOLTAGE
10 kHz - 2 MHz
—
—
—
—
16
—
30
50
5
80
120
50
—
—
—
—
16
—
30
50
5
80
120
50
—
—
—
—
16
—
60
120
mV p-p
Tc = –55°C to +100°C
Vin = 16 to 40 VDC
NO LOAD TO FULL
CONTINUOUS
100 180
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
50
50
28
—
150
150
40
mV
mV
VDC
V
20
28
—
50
20
28
—
50
40
40
TRANSIENT 50 ms
50
50
50
INPUT CURRENT
NO LOAD
FULL LOAD
—
—
—
—
—
78
25
50
—
—
—
—
—
78
25
62
—
—
—
—
—
82
25
60
680 752
670 752
640 760
mA
INHIBITED
5
12
80
5
12
80
5
12
80
INPUT RIPPLE
CURRENT
10 kHz - 10 MHz
Tc = –55°C to +100°C
35
—
79
35
—
80
35
—
84
mA pp
%
120
—
120
—
120
—
EFFICIENCY
1
LOAD FAULT
SHORT CIRCUIT
POWER DISSIPATION
—
—
3.5
7.5
6
—
—
3.5
7.5
6
—
—
3.5
7.5
6
W
2
RECOVERY
30
30
30
ms
STEP LOAD RESP.
STEP LINE RESP.
START-UP
50% – 100% – 50%
TRANSIENT
–500 150 500
150 300
–600 200 600
150 300
–800 600 800
200 400
mV pk
µs
2
RECOVERY
—
—
—
16 – 40 – 40 VDC
3
TRANSIENT
–800 550 800
–800 550 800
–1200 1100 1200
mV pk
ms
2
RECOVERY
—
0
0.8
10
1.2
25
—
0
0.8
10
1.2
25
—
0
0.8
10
1.2
25
DELAY
ms
4
OVERSHOOT
0
200 1200
0
200 1500
0
200 280
mV pk
Notes
1. Indefinite short circuit protection not guaranteed above 100°C (case)
2. Recovery time is measured from application of the transient to point at
which Vout is within regulation.
3. Input step transition time >10µs.
4. Input step transition time <100µs.
7
MDC SERIES
UP TO 60 WATTS
FACTORY CONFIGURABLE DC/DC CONVERTERS
15 Watt Dual Output Modules
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL OUTPUT MODULES
05D
12D
15D
TYP
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
MIN
MAX
UNITS
OUTPUT VOLTAGE
+V
4.95
5.00
5.05
11.88
12.00
12.12
14.85
15.00
15.00
15.15
OUT
VDC
–V
OUT
4.92
5.00
5.08
11.82
12.00
1218
14.78
15.23
1
OUTPUT CURRENT
V
= 16 to 40 VDC
= 16 to 40 VDC
—
—
1.2
1.92
12
—
—
0.625
1.125
15
—
—
0.500
0.900
15
A
IN
IN
1
OUTPUT POWER
V
—
—
—
W
OUTPUT RIPPLE
10 kHz - 2 MHz
—
—
30
60
80
—
—
30
60
80
—
—
30
50
80
mV p-p
mV
VOLTAGE
V
Tc = –55°C to +100°C
120
120
120
OUT
LINE REGULATION
BALANCED +V
OUT
—
5
50
—
5
50
—
5
50
Vin = 16 to 40 VDC
LOAD REGULATION
LOAD
BALANCED +V
LOAD –V
NEGATIVE V
–V
—
—
—
80
50
—
—
—
100
50
—
—
—
100
50
OUT
20
20
20
OUT
mV
%
—
—
—
100
7.5
—
—
—
100
6
—
—
—
100
6
OUT
2
CROSS REGULATION
6
3
3
OUT
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
CONTINUOUS
TRANSIENT 50 msec
NO LOAD
16
—
—
—
—
—
—
77
28
—
40
50
40
600
12
50
80
—
16
—
—
—
—
—
—
76
28
—
40
50
16
—
—
—
—
—
—
76
28
—
40
50
VDC
V
20
540
6
25
645
5
50
25
638
5
50
FULL LOAD
754
12
754
12
mA
INHIBITED
INPUT RIPPLE
CURRENT
10 kHz - 10 MHz
Tc = –55°C to +100°C
20
40
79
35
50
83
60
35
50
84
60
mA p-p
%
100
—
100
—
EFFICIENCY
3
LOAD FAULT
SHORT CIRCUIT
POWER DISSIPATION
—
—
3
6
—
—
3
6
—
—
3
6
W
4
RECOVERY
7.5
30
7.5
50
7.5
50
ms
5
STEP LOAD RESP.
50% – 100% – 50%
+V
OUT
–600
200
600
–600
300
600
–600
300
600
TRANSIENT
mV pk
µs
–V
–600
150
150
600
500
–600
100
200
500
400
–600
100
200
600
500
OUT
4
RECOVERY
—
—
—
STEP LINE RESP.
16 – 40 – 40 VDC
6
V
TRANSIENT
–800
600
800
–750
550
750
–750
550
750
mV pk
OUT
4
RECOVERY
—
—
0
0.8
12
1.2
20
—
—
0
0.8
12
1.2
25
—
—
0
0.8
12
1.2
25
ms
ms
START-UP
DELAY
7
OVERSHOOT
100
250
200
750
200
750
mV pk
Notes
1. Up to 13.5 watts, 90% (9.6W, 80% for 2805D) of the total output power is
available from either output providing the opposite output is simultaneously
carrying 10% (20% for 2805D) of the total output power. Each
output must carry a minimum of 10% (20% for 2805D) of the total output
power in order to maintain regulation on the negative outputs.
2. Effect on –Vout for the following conditions:
3. Indefinite short circuit protection not guaranteed above 100°C (case)
4. Recovery time is measured from application of the transient to point at
which Vout is within regulation.
5. Response of either output with the opposite output held at half of the total
output power.
6. Input step transition time >10µs.
+Po = 50% to 10% and –Po = 50%
7. Input step transition time <100µs.
+Po = 50% and –Po = 50% to 10%
8
MDC SERIES
FACTORY CONFIGURABLE DC/DC CONVERTERS
UP TO 60 WATTS
5 Watt Single Output Modules
ABSOLUTE MAXIMUM RATINGS
INHIBIT
TYPICAL CHARACTERISTICS
Input Voltage
• 16 to 40 V
Output Power
• 5 watts
Lead Soldering Temperature (10 sec per lead)
• 300°C
Storage Temperature Range (Case)
• –65°C to +135°C
Inhibit TTL Open Collector
• Logic low (output disabled)
Logic low voltage ≤0.8 V
Inhibit pin current 4 mA max
• Referenced to input common
• Logic high (output enabled)
Open collector
Output Voltage Temperature Coefficient
• 100 ppm/°C typical
Input to Output Capacitance
• 50 pF typical
Isolation
• 100 megohm minimum at 500 V
Audio Rejection
• 50 dB typical
RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
• 16 to 40 VDC continuous
• 50 V for up to 50 msec transient
Case Operating Temperature (Tc)
• –55°C to +100°C full power
Conversion Frequency
• 550 kHz typical (400 kHz 60 V model)
450 kHz min, 600 kHz max
350 kHz min, 450 kHz max 60 V model
Inhibit Pin Voltage (unit enabled)
• 9 to 11 V
• –55°C to +115°C absolute
Derating Output Power/Current (Tc)
• Linearly from 100% at 100°C to 0% at 135°C
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
SINGLE OUTPUT MODULES
PARAMETER
5S
5R2S
12S
15S
CONDITIONS
MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX
UNITS
OUTPUT VOLTAGE
OUTPUT CURRENT
Tc = –55°C TO +100°C
Tc = –55°C TO +100°C 4.95 5.00 5.05 5.15 5.20 5.25 11.88 12.00 12.12 14.85 15.00 15.15
VDC
V
V
= 16 TO 40 VDC
= 16 TO 40 VDC
0
—
—
1000
5
0
—
—
962
5
0
—
—
417
5
0
—
—
333
5
mA
W
IN
OUTPUT POWER
IN
Tc = –55°C TO +100°C
—
—
—
—
OUTPUT RIPPLE
VOLTAGE
LINE REGULATION
10 kHz - 2 MHz
—
—
—
125 350
1
—
—
—
110 335
—
—
—
50
10
10
200
50
—
—
—
50 170
mV p-p
mV
V
= 16 TO 40 VDC
IN
Tc = –55°C TO +100°C
NO LOAD TO FULL
Tc = –55°C TO +100°C
Tc = –55°C TO +100°C
CONTINUOUS
TRANSIENT 50 ms
NO LOAD
FULL LOAD
10
50
10
10
50
50
10
10
50
50
LOAD REGULATION
10
50
50
mV
INPUT VOLTAGE
NO LOAD TO FULL
16
0
28
—
27
250
3
40
50
40
—
16
0
28
—
28
250
3
40
50
40
—
16
0
28
—
29
235
3
25
30
76
1.2
1
40
50
42
—
16
0
28
—
31
235
3
40
50
44
—
4
VDC
V
INPUT CURRENT
Tc = –55°C TO +100°C
—
—
—
—
—
66
—
—
—
—
—
—
—
66
—
—
—
—
—
—
—
70
—
—
—
—
—
—
—
71
—
—
mA
INHIBITED
10 kHz - 10 MHz
Tc = –55°C TO +100°C
4
4
4
INPUT RIPPLE
CURRENT
25
30
71
100
150
—
25
30
71
1.5
1.5
100
150
—
2.0
25
100
150
—
1.9
10
25 100
30 150
mA p-p
EFFICIENCY
LOAD FAULT
76
1.2 1.8
10
—
%
W
ms
2, 3
POWER DISSIPATION
RECOVERY
50% - 100% - 50%
TRANSIENT
1.5
12.5
2.0
25
SHORT CIRCUIT
STEP LOAD
1
3, 4
RESPONSE
—
—
100 250
100 250
—
—
100 250
100 250
—
—
150 375
200 500
—
—
200 500
200 500
mV pk
µs
RECOVERY
STEP LINE
RESPONSE
TRANSIENT
16 TO 40 V
IN
3, 4
—
—
50
50
150
150
—
—
50
50
150
150
—
—
80
200
—
—
50 125
50 125
mV pk
µs
40 TO 16 V
IN
100 250
RECOVERY
16 TO 40 V
IN
—
—
100 250
200 500
—
—
100 250
200 500
—
—
250 625
250 625
—
—
250 625
250 625
40 TO 16 V
IN
START-UP
DELAY
OVERSHOOT
—
—
10
0
25
50
—
—
10
0
25
50
—
—
3
0
10
120
—
—
3
0
10
150
ms
mV pk
Notes
1. Line regulation for /ES and non /ES 2805S models at 16 to 17 V and 85 °C
to 100°C (case) is 5% (max).
2. Indefinite short circuit protection not guaranteed above 100°C (case).
3. Recovery time is measured from application of the transient to point at which
is within 1% of V at final value.
IN
V
OUT
4. Transition time >10µs.
OUT
9
MDC SERIES
UP TO 60 WATTS
FACTORY CONFIGURABLE DC/DC CONVERTERS
5 Watt Dual Output Modules
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
DUAL OUTPUT MODULES
05D
12D
TYP
15D
TYP
PARAMETER
CONDITIONS
MIN
4.95
4.9
TYP
5.00
5.0
MAX
5.05
5.1
MIN
MAX
12.12
12.24
MIN
MAX
UNITS
OUTPUT VOLTAGE
+V
11.88 12.00
11.76 12.00
14.85 15.00 15.15
14.70 15.00 15.30
OUT
VDC
–V
OUT
1
OUTPUT CURRENT
V
= 16 to 40 VDC
IN
Tc = –55°C to +125°C
—
500
800
—
208
333
—
167
267
mA
1
OUTPUT POWER
V
= 16 to 40 VDC
IN
Tc = –55°C to +125°C
—
—
—
—
5
—
—
—
5
—
—
—
5
W
OUTPUT RIPPLE VOLT.
10 kHz - 2 MHz
150
40
140
60
150
mV p-p
LINE REGULATION
Vin = 16 to 40 VDC
Tc = –55°C to +125°C
+V
—
—
10
40
25
75
—
—
10
40
50
—
—
10
40
50
OUT
mV
mV
–V
180
180
OUT
LOAD REGULATION
NO LOAD TO FULL
Tc = –55°C to +125°C
+V
—
—
10
50
50
—
—
10
50
50
—
—
10
50
50
OUT
–V
200
200
200
OUT
2
CROSS REGULATION
+P = 20 - 80 %, –P = 80 - 20%
O
O
—
—
10
5
20
8
—
—
8
15
6
—
—
7
3
15
6
–P = 20 - 80 %, +P = 80 - 20%
O
O
%
+P = 50 - 10 %, –P = 50%
O
O
3.7
–P = 50 - 10 %, +P = 50%
O
O
NO LOAD TO FULL
˜CONTINUOUS
INPUT VOLTAGE
Tc = –55°C to +125°
16
28
40
16
28
40
16
28
40
VDC
V
TRANSIENT 50 msec
NO LOAD
—
—
—
50
35
—
—
—
50
58
—
—
—
50
60
INPUT CURRENT
30
33
38
Tc = –55°C to +125°C
FULL LOAD
INHIBITED
—
—
—
—
68
248
3
—
5
—
—
—
—
69
235
3
—
4
—
—
—
—
70
235
3
—
4
mA
INPUT RIPPLE
CURRENT
10 kHz TO 10 MHz
Tc = –55°C to +125°C
25
30
72
80
160
—
25
30
75
100
150
—
25
30
75
100
150
—
mA p-p
%
EFFICIENCY
3, 4
LOAD FAULT
POWER DISSIPATION
SHORT CIRCUIT
—
—
1.3
1.8
50
—
—
1.3
1
1.7
10
—
—
1.3
1
1.6
10
W
RECOVERY
50% - 100% - 50% BALANCED
TRANSIENT
—
ms
STEP LOAD
4, 5
RESPONSE
—
—
—
—
150
100
—
—
300
200
750
500
—
—
300
500
750
mV
µs
RECOVERY
1250
4, 5
STEP LINE RESP.
16 TO 40 VDC
—
—
—
—
—
—
—
—
—
—
—
—
750
500
—
—
—
—
—
—
50
50
150
400
3
125
125
375
1000
10
—
—
—
—
—
—
150
100
250
800
3
375
250
625
2000
10
mV pk
µs
TRANSIENT
40 TO 16 VDC
16 TO 40 VDC
1200
1200
25
RECOVERY
40 TO 16 VDC
START-UP
Notes
DELAY
ms
OVERSHOOT
500
0
120
0
150
mV pk
1. Up to 4 watts (80% full power) is available from either output providing the
opposite output is carrying 20% of total power.
3. Indefinite short circuit protection not guaranteed above 100°C (case).
4. Recovery time is measured from application of the transient to point at which
2. Shows regulation effect on the minus output during the defined cross loading
conditions. See Figures 15 and 16.
V
is within 1% of V at final value.
OUT
OUT
5. Transition time >10µs.
10
MDC SERIES
FACTORY CONFIGURABLE DC/DC CONVERTERS
UP TO 60 WATTS
1.5 Watt Single Output Modules
TYPICAL CHARACTERISTICS
INHIBIT
ABSOLUTE MAXIMUM RATINGS
Output Voltage Temperature Coefficient
• 100 ppm/°C typical
Input to Output Capacitance
• 100 to 170 pF typical
Undervoltage Lockout
• 8 V input typical
Current Limit
Inhibit – TTL Open Collector
• Logic low (output disabled) 0.8 V max
Inhibit pin current 1 mA max
• Referenced to input common
• Logic high (output enabled) open collector
Input Voltage
• 12 to 50 VDC
Output Power
• 1.5 W
Capacitive Load
• Single output models 200 µF
• Dual output models 100 µF
Lead Soldering Temperature (10 sec per lead)
• 300°C
Storage Temperature Range (Case)
• –65°C to +150°C
RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
• 12 to 50 VDC continuous
• 80 V for 120 msec transient
(70 V for 15 V single and dual models)
Case Operating Temperature (Tc)
• –55°C to +100°C full power
• –55°C to +115°C absolute
Derating Output Power/Current (Tc)
• Linearly from 100% at 100°C to 0% at 115°C
• 100% of full load typical
Isolation
• 100 megohm minimum at 500 V
Audio Rejection 40 dB, typical
Conversion Frequency (kHz)
• 25°C, 300 min, 370 typ, 450 max
• –55°C to +100°C
270 min, 370 typ, 470 max
Inhibit Pin Voltage (unit enabled)
• 7 to 12 V
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
SINGLE OUTPUT MODULES
PARAMETER
OUTPUT VOLTAGE
3R3S
05S
5R2S
12S
15S
CONDITIONS
Tc = 25°C
MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
1
4.95
4.80
0
5
5
5.05 5.15 5.2 5.25 11.88 12 12.12 14.85 15 15.15
5.20 5.00 5.2 5.40 11.52 12 12.48 14.40 15 15.60
VDC
Tc = –55°C TO +100°C
OUTPUT CURRENT
OUTPUT POWER
V
= 12 to 50 VDC
—
300
0
—
288
0
—
125
0
—
100
mA
W
IN
V
= 12 TO 50 VDC
0
—
1.5
0
—
1.5
0
—
1.5
0
—
1.5
IN
OUTPUT RIPPLE
VOLTAGE
LINE REGULATION
10 kHz - 2 MHz
Tc = –55°C TO +100°C
= 12 TO 50 VDC
Tc = –55°C TO +100°C
10% TO FULL LOAD
Tc = –55°C TO +100°C
50% TO FULL
Tc = –55°C TO +100°C
CONTINUOUS
TRANSIENT 120 ms
NO LOAD
Tc = –55°C TO +100°C
FULL LOAD
Tc = –55°C TO +100°C
INHIBITED
Tc = –55°C TO +100°C
10k Hz - 10 MHz
Tc = –55°C TO +100°C
Tc = 25°C
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
—
—
72
69
—
—
—
—
45
65
35
40
150
300
100
120
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
—
—
75
69
—
—
—
—
45
65
35
40
150
300
100
120
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
—
—
74
72
—
—
—
—
50 200
70 300
60 200
70 250
600 1300
640 1400
145 300
160 400
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
—
—
74
72
—
—
—
—
35 150
50 250
70 300
80 350
700 1500
760 1600
165 350
185 450
mV p-p
mV
V
IN
LOAD REGULATION
350 700
380 800
100 200
115 300
28
—
5.5
6.0
70
73
2.3
2.4
100 200
130 250
77
75
350 700
380 800
100 200
115
28
mV
300
50
80
10
11
74
78
3.2
3.5
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
50
80
10
11
74
78
3.2
3.5
28
—
6
6.5
68
70
50
80
10
12
72
74
28
—
6.0
6.5
68
70
50
70
11
12
72
74
VDC
V
—
5.5
6.0
70
73
2.3
2.4
100 200
130 250
77
75
mA
AVAILABLE
2.3 3.2
2.4 3.5
100 200
150 250
2.3 3.2
2.4 3.5
100 200
150 250
SOON, ASK
YOUR
INPUT RIPPLE
mA p-p
%
INTERPOINT
2
CURRENT
REP FOR
EFFICIENCY
—
—
—
—
79
77
—
—
79
77
—
—
Tc = –55°C TO +100°C
POWER DISSIPATION
Tc = –55°C TO +100°C
RECOVERY
INFORMATION
3, 4
LOAD FAULT
1.3
1.4
3.0
3.5
2.0
2.3
12
15
1.3
1.4
3.0
3.5
2.0
2.3
12
15
2.0 3.2
2.2 3.5
2.3 3.7
2.5 4.0
W
3.5
3.5
15
20
4.0
4.0
18
20
ms
Tc = -–55°C TO +100°C
STEP LOAD
RESPONSE
50 %–100%– 50% LOAD
5
TRANSIENT
Tc = –55°C TO +100°C
RECOVERY
–400 185 400 –400 185 400 –700 350 700 –700 350 700
–500 185 500 500 185 500 –800 380 800 –800 380 800
mV pk
µs
—
—
125 500
125 600
—
—
125 500
125 600
—
—
130 500
130 600
—
—
140 600
180 750
Tc = –55°C TO +100°C
STEP LINE
RESPONSE
12 TO 50 TO 12 V
IN
5
TRANSIENT
Tc = –55°C TO +100°C
RECOVERY
–400 170 400 –400 170 400 –900 400 900 –750 400 750
–500 180 500 –500 180 500 –1000 400 1000 –850 450 850
mV pk
ms
—
—
—
—
—
—
0.75 3.0
0.75 4.0
—
—
—
—
—
—
0.75 3.0
0.75 4.0
—
—
—
—
—
—
0.6 2.5
0.6 3.0
—
—
—
—
—
—
0.47 2.0
0.5 2.5
Tc = –55°C TO +100°C
DELAY
Tc = –55°C TO +100°C
OVERSHOOT
START-UP
0 TO 28 VDC
7
10
0
20
40
100
150
7
10
0
20
40
100
150
7
10
0
20
40
250
350
7
10
0
20
40
300
450
ms
mV pk
Tc = –55°C TO +100°C
0
0
0
0
See notes 1, 2, 3, 4, 5, and 6 on the following page.
11
MDC SERIES
UP TO 60 WATTS
FACTORY CONFIGURABLE DC/DC CONVERTERS
1.5 Watt Dual Output Modules
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
DUAL OUTPUT MODULES
PARAMETER
OUTPUT VOLTAGE
5D
12D
15D
CONDITIONS
Tc = 25°C
MIN TYP MAX
MIN TYP MAX
MIN TYP MAX
UNITS
1
4.95
4.80
0
5
5
5.05
5.20
240
11.88
11.52
0
12
12
12.12 14.85
15
15.15
15.60
80
VDC
Tc = –55°C TO +100°C
12.48 14.40 15
6
OUTPUT CURRENT
V
= 12 TO 50 VDC
150
62.5 100
0
0
50
mA
W
IN
IN
OUTPUT POWER
OUTPUT RIPPLE
V
= 12 TO 50 VDC
0
—
1.5
0
—
1.5
—
1.5
10 kHz - 2 MHz
—
—
35
50
150
250
—
—
35
40
150
250
—
—
30
35
150
250
VOLTAGE +V
OUT
Tc = –55°C TO +100°C
mV p-p
–V
10 kHz - 2 MHz
—
—
—
—
—
—
35
50
150
250
50
—
—
—
—
—
—
35
40
150
250
—
—
—
—
—
—
30
150
250
OUT
Tc = –55°C TO +100°C
35
7
LINE REGULATION
V
= 12 TO 50 VDC
10
100
110
550
570
300
165
180
600
630
500
IN
mV
mV
Tc = –55°C TO +100°C
20
100
600
700
400
650
8
LOAD REGULATION
10% TO FULL
300
350
1100
1200
1300
1400
V
–55°C TO +100°C
OUT
50% TO FULL
–55°C TO +100°C
CONTINUOUS
—
—
12
0
80
100
28
200
300
50
—
—
12
0
115
130
28
250
350
50
—
—
12
0
125
135
28
300
400
50
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
VDC
V
TRANSIENT 120 ms
NO LOAD
—
80
—
80
—
70
—
—
—
—
—
—
—
—
73
70
5.0
6.0
69
10
—
—
—
—
—
—
—
—
73
70
7.5
8.0
70
13
—
—
—
—
—
—
—
—
72
69
7.5
8.0
71
13
Tc = –55°C TO +100°C
FULL LOAD
12
14
14
73
73
74
mA
Tc = –55°C TO +100°C
INHIBITED
72
77
71
77
72
78
2.3
2.4
100
130
77
3.2
3.5
200
250
—
2.3
2.4
115
150
77
3.2
3.5
200
250
—
2.3
2.4
90
3.2
3.5
200
250
—
Tc = –55°C TO +100°C
10 kHz - 10 MHz
Tc = –55°C TO +100°C
Tc = 25°C
2
INPUT RIPPLE
mA p-p
%
CURRENT
120
76
EFFICIENCY
Tc = –55°C TO +100°C
75
—
75
—
74
—
3,4
LOAD FAULT
POWER DISSIPATION
Tc = –55°C TO +100°C
RECOVERY
—
—
—
—
1.4
1.6
3.7
3.8
2.2
2.5
15
—
—
—
—
2.5
2.7
3.2
3.2
3.8
4.2
15
—
—
—
—
2.7
3.0
4.0
4.0
4.1
4.5
15
W
ms
Tc = –55°C TO +100°C
50 %–100%– 50% LOAD
TRANSIENT
20
20
20
STEP LOAD
5
RESPONSE
V
V
–300 130
300
400
400
500
–600 250
–700 260
600
700
700
800
–600 250
–700 270
600
700
200
300
OUT
mV pk
µs
Tc = –55°C TO +100°C –400 140
RECOVERY
–55°C TO +100°C
12 TO 50 TO 12 V
—
—
100
100
—
—
165
165
—
—
50
50
STEP LINE
RESPONSE
IN
5
TRANSIENT
–250 125
250
300
2.5
3.0
25
–500 240
–600 250
500
600
3.0
4.0
25
–500 220
–600 230
500
600
3.0
4.0
25
OUT
mV pk
ms
Tc = –55°C TO +100°C –300 130
RECOVERY
Tc = –55°C TO +100°C
DELAY
—
—
—
—
0.6
0.6
8
—
—
—
—
0.9
0.9
8
—
—
—
—
0.6
0.7
8
START–UP
ms
0 TO 28 VDC,
V
Tc = –55°C TO +100°C
10
45
10
45
10
45
OUT
OVERSHOOT
—
—
0
0
100
150
—
—
0
0
250
350
—
—
0
0
750
900
mV pk
Tc = –55°C TO +100°C
Notes:
1. Specified at 50% load.
2. Lin = 2 µH.
6. Max. spec indicates 80% of the converter’s total power, available from either
output.
3. Maximum duration of short circuit:: 25°C-– 90 seconds, 100°C – 30 seconds.
4. Load fault is a short circuit (<50 mohms). Recovery is into resistive full load.
5. Transition ≥ 10 µs. Recovery = time to settle to within 1% of Vout final value.
7. Specification applies to both + and – Vout.
8. Although no minimum load is required, at no load the output voltage may
increase up to 15%.
12
MDC SERIES
UP TO 60 WATTS
FACTORY CONFIGURABLE DC/DC CONVERTERS
Case Outline Drawings
Pinouts will vary depending on customer choices.
18x 0.040
0.002 PIN
0.23 (5.8) Lead Length
2.250
2.130
1.925
1.725
0.525
1.325
1.125
0.925
0.725
0.525
0.325
1
2
3
4
5
6
7
8
9
18
17
16
15
14
13
12
11
10
Top View
0.120
0.000
4x 0.128
+ 0.002/
-0.001 Thru
Figure 3: Case for A through E Options
Case size 3.005 x 2.260 x 0.400 inches , 76.33 x 57.40 x 10.16 mm
13
MDC SERIES
UP TO 60 WATTS
FACTORY CONFIGURABLE DC/DC CONVERTERS
Case Outline Drawings
Pinouts will vary depending on customer choices.
Seam Seal
Angled corner
indicates pin one.
0.23 (5.8) Lead Length
0.128 dia
(3.25).
1.505 (38.23) max.
1.380 (35.05)
0.040 dia
(1.02)
1
2
3
4
5
6
12
11
10
9
1.250 (31.75)
1.050 (26.67)
0.850 (21.59)
0.650 (16.51)
0.450 (11.43)
TOP VIEW
8
(Pin side, marked side)
0.250 (6.35)
0.120 (3.05)
0.000
7
Figure 4: Case for F and G Options
Case size 3.005 x 1.500 x 0.400 inches, 76.33 x 38.23 x 10.16 mm
14
MDC SERIES
UP TO 60 WATTS
FACTORY CONFIGURABLE DC/DC CONVERTERS
Table 4: ENVIRONMENTAL SCREENING
TEST
STANDARD
/ES
yes
yes
yes
yes
yes
PRE-CAP INSPECTION
Method 2017, 2032
no
no
TEMPERATURE CYCLE (10 times)
Method 1010, Cond. B, -55°C to 125°C
CONSTANT ACCELERATION
Method 2001, 500 g
no
BURN-IN
Method 1015, 96 hours at 100°C case
no
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A
Subgroups 1 and 4: +25°C case
yes
HERMETICITY TESTING
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip (1 x 10 )
no
no
yes
yes
yes
no
-3
FINAL VISUAL INSPECTION
Method 2009
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Contact Information:
www.interpoint.com
Interpoint Headquarters USA
Phone: 1-800-822-8782
+425-882-3100
Interpoint UK
Phone: +44-1252-815511
Interpoint France
Phone: +33-134285455
Email:
poweruk@intp.com
Email:
powerfr@intp.com
Email:
power@intp.com
MDC-DTS Rev C
All technical information is believed to be accurate, but no responsibility is
assumed for errors or omissions. Interpoint reserves the right to make changes in
products or specifications without notice. MDC Series is a trademark of Interpoint.
Copyright © 2000-2001 Interpoint. All rights reserved.
15
MDCA/05S/05D 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
MDCA/05S/12D | CRANE | Analog Circuit | 获取价格 | |
MDCA/05S/12S | CRANE | Analog Circuit | 获取价格 | |
MDCA/05S/15D | CRANE | Analog Circuit | 获取价格 | |
MDCA/05S/18S | CRANE | Analog Circuit | 获取价格 | |
MDCA/12D/12D | CRANE | Analog Circuit, | 获取价格 | |
MDCA/12D/12S | CRANE | DC-DC Regulated Power Supply Module, 3 Output, 60W, Hybrid, | 获取价格 | |
MDCA/12D/15D | CRANE | Analog Circuit, | 获取价格 | |
MDCA/12D/15D/ES | CRANE | DC-DC Regulated Power Supply Module, 4 Output, 60W, Hybrid | 获取价格 | |
MDCA/12D/15S | CRANE | DC-DC Regulated Power Supply Module, 3 Output, 60W, Hybrid, | 获取价格 | |
MDCA/12D/15S/ES | CRANE | DC-DC Regulated Power Supply Module, 3 Output, 60W, Hybrid | 获取价格 |
MDCA/05S/05D 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6