DRC_17 [CRYDOM]

DIN Rail Mount;
DRC_17
型号: DRC_17
厂家: CRYDOM INC.,    CRYDOM INC.,
描述:

DIN Rail Mount

文件: 总11页 (文件大小:1965K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DIN Rail Mount  
DataSheet  
DRC Series with  
EMR Auxiliary Contacts  
Start / Stop Reversing  
7.6 Amp AC Semiconductor Motor Controller  
Load voltage range up to 600 VAC  
Fits standard 35mm DIN Rail  
LED input status indicator  
AC or DC control  
Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output  
C-UL-US Listed, IEC Rated, CE & RoHS Compliant, Horsepower Rated  
Built-in Overvoltage Protection  
Ultra-efficient thermal management design (Patented)  
See DRC Series models with Solid State Auxiliary Contacts  
Solicon DRC Series with EMR Auxiliary Contacts are Solid State instantaneously upon application of the control voltage unless an  
Contactors intended for frequently switching on and off three instantaneous change of direction is commanded, then it will  
phase loads up to 5 HP, 600 VAC 7.6 Amps. They are available in delay the direction change by 100msec in order to prevent  
both contactor versions DRC3P and reversing contactor versions simultaneous forward and reverse operations.  
DRC3R.  
All the models of Solicon DRC Series with EMR Auxiliary Contacts  
The Solicon Contactor DRC3P is available in either instantaneous combine the benefits and advantages of a solid state contactor  
turn-on (for Motor Control) or zero voltage turn-on (for Resistive with the functionality and simplicity of use of an  
Loads). It is available in either 2 or 3 controlled leg versions. The electromechanical contactor thanks to the proprietary thermal  
2 legs control version is particularly suitable for motor control management technology (Patented) and complete electrical  
circuits where the neutral conductor is not utilized.  
insulation (no grounding required); the embedded EMR auxiliary  
contacts, normally open and/or normally closed, are intended to  
be used at 110VDC/140VAC. All models include overvoltage  
protection.  
The Solicon Reversing Contactor DRC3R includes an interlock  
control that allows only off, forward and reverse operation in a  
safe mode while providing high space saving; it switches  
PRODUCT SELECTION  
Control Voltage  
24 VAC/DC  
1 NO + 1NC Auxiliary Contact  
2 NO Auxiliary Contact  
DRC3P48D440, DRC3P60D440  
DRC3R40E440, DRC3R48E440  
DRC3P48D433, DRC3P60D433  
24 VDC  
AVAILABLE OPTIONS  
Operating Voltage  
40: 400 VAC  
Load Current per Phase  
4: 7.6 Amp FLA  
(3R function only)  
48: 480 VAC  
60: 600 VAC  
(x2 Controlled Legs  
& 3R function);  
4.8 Amp FLA  
Switching Mode  
(3P function only)  
Blank: Zero Voltage Turn-On  
(3P function only)  
Series  
(x3 Controlled Legs only) R: Instantaneous Turn-On  
4
DRC 3P 48  
D
33  
R
2
Function  
Control Voltage  
D: 18-30 VAC/DC  
(3P function only)  
E: 18-30 VDC  
Auxiliary Contacts,  
N.O. - N.C.  
Controlled Legs  
(3P function only)  
3P: Contactor  
3R: Reversing Contactor  
33: 1 Normally Open EMR ; Blank: 3 Controlled Legs  
1 Normally Closed EMR 2: 2 Controlled Legs  
(3P function only)  
(3R function only)  
40: 2 Normally Open EMR  
Required for valid part number  
For options only and not required for valid part number  
FDE-07-01 REV. A  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
(1)  
OUTPUT SPECIFICATIONS  
Description  
DRC3P48D4x DRC3P48D4x2 DRC3P60D4x DRC3P60D4x2 DRC3R40E440 DRC3R48E440  
Operating Voltage (47-63Hz) [VRMS]  
Transient Overvoltage [Vpk] (2)(3)  
Maximum Off-State Leakage Current @ Rated Voltage [mARMS]  
Maximum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]  
48-530  
1200  
3.0  
48-530  
1200  
3.0  
48-600  
1200  
1.0  
48-600  
1200  
1.0  
48-415  
1200  
5.5  
48-510  
1600  
5.5  
500  
500  
500  
500  
500  
500  
Load Current, General Use UL508 /AC51 @40°C [ARMS] (4)  
Load Current, Motor Controller UL508 /AC-53a @480VAC [ARMS] (4)  
Minimum Load Current [ARMS]  
5
4.8  
0.15  
7.6  
7.6  
0.15  
5
4.8  
0.15  
7.6  
7.6  
0.15  
7.6  
7.6  
0.15  
7.6  
7.6  
0.15  
Maximum Surge Current [Apk] 1 Cycle 60Hz  
750  
750  
750  
750  
750  
625  
Maximum Surge Current [Apk] 1 Cycle 50Hz  
716  
2330  
2560  
716  
2330  
2560  
716  
2330  
2560  
716  
2330  
2560  
716  
2330  
2560  
597  
1621  
1779  
Maximum I2t for Fusing (8.33msec)[A2sec]  
Maximum I2t for Fusing (10msec)[A2sec]  
Maximum On-State Voltage Drop @ Rated Current [VRMS]  
Minimum Power Factor (with Maximum Load)  
Ratings according to UL 508/IEC60947-4-2 [HP/kW]: 240 VAC  
Ratings according to UL 508/IEC60947-4-2 [HP/kW]: 400 VAC  
Ratings according to UL 508/IEC60947-4-2 [HP/kW]: 480 VAC  
Motor Ratings @ 600 VAC [HP/kW]  
1.15 per channel  
1.15 per channel  
1.15 per channel  
0.7  
1.15 per channel  
0.7  
1.3 per channel  
1.3 per channel  
0.5  
1/.75  
2/1.5  
3/2.2  
-
0.5  
2/1.5  
3/2.2  
5/3.7  
-
0.5  
2/1.5  
3/2.2  
-
0.5  
2/1.5  
3/2.2  
5/3.7  
-
1/.75  
2/1.5  
3/2.2  
3/2.2  
2/1.5  
3/2.2  
5/3.7  
5/3.7  
-
INPUT SPECIFICATIONS (1)  
Description  
Control Voltage Range  
Option D  
18-30 VAC / VDC  
Option E  
18-30 VDC  
Minimum Turn-On Voltage (5)  
Must Turn-Off Voltage  
18 VAC / VDC  
4 VAC / VDC  
18 VDC  
4 VDC  
Minimum Input Current (for on-state) [mA]  
Maximum Input Current [mA]  
Nominal Input Impedance [Ohms]  
Maximum Delay to Turn-On [msec] (6)  
Maximum Turn-Off Time [msec] (7)  
12.5  
32  
12.5  
32  
Current Regulated  
100 30  
Current Regulated  
20  
30  
20  
AUXILIARY CONTACTS(1)  
Description  
Maximum Operating Voltage  
Transient Overvoltage [Vpk]  
Maximum Load Current [Adc/Arms] (8)  
Maximum Contact Rating [W] (8)  
Normally Open Suffix 40 [3P] Normally Closed / Normally Open Suffix 33 Normally Open Suffix 40 [3R]  
110VDC/ 140VAC  
110VDC/ 250VAC  
250  
110VDC/ 140VAC  
250  
0.5/0.35  
10/7  
250  
0.5/0.35  
10/7  
0.3/0.25  
33/62.5  
Minimum Load Current [mA]  
Maximum Delay to Turn-On [msec]  
10  
20  
10  
20  
10  
100 30  
Maximum Turn-Off Time [msec]  
30  
20  
108  
105  
30  
20  
108  
105  
20  
Maximum Delay to Turn-On [msec]  
100 30  
Mechanical Life Expectancy [Ops.]  
Electrical Life Expectancy [Ops.]  
108  
105  
GENERAL SPECIFICATIONS(1)  
Description  
Parameters  
Dielectric Strength, Input/Output/Base (50/60Hz) (9)  
Minimum Insulation Resistance (@ 500 VDC)  
Maximum Capacitance, Input/Output  
Ambient Operating Temperature Range (10)  
Ambient Storage Temperature Range  
3750 Vrms  
109 Ohms  
20 pF  
-20 to 60 °C  
-30 to 85 °C  
Weight (typical)  
2 Controlled Legs (6.9 oz [197 g]) / 3 Controlled Legs (8.0 oz [228 g])  
Housing Material  
UL94 V-0  
Housing Color  
Black and Light Gray  
LED Status Indicator (color) (11)  
Short Circuit Current Rating (12)  
Pollution Degree  
Forward (Green) / Reverse (Amber)  
100kA  
2
Protection Degree (13)  
Humidity  
IP20  
85% non-condensing  
Control and Auxiliary Contact Terminal Screw Torque Range (lb-in/Nm)  
Load Terminal Screw Torque Range (lb-in/Nm)  
Input Terminal Wire Capacity  
12 / 1.36  
15 / 1.7  
18-12 AWG (IEC 1-4 mm2) (stranded /solid)  
18-10 AWG (IEC 1-6 mm2 ) (stranded /solid)  
Output Terminal Wire Capacity  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
(14)  
THERMAL DERATE INFORMATION  
DRC3P (3 controlled legs)  
DRC3P (2 controlled legs) & DRC3R  
Single unit (15)  
Multiple units  
Single unit (15)  
Multiple units  
6
5
4
3
2
1
0
8
7
6
5
4
3
2
1
0
20  
30  
40  
50  
60  
20  
30  
40  
50  
60  
Ambient Temperature (ºC)  
Ambient Temperature (ºC)  
EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM  
(16)  
DRC3P CONTACTOR  
DRC3R REVERSING CONTACTOR(17)  
DRC3Pxx433  
DRC3Pxx440  
DRC3Rxx440  
48-530 VAC, 50-60 Hz  
48-600 VAC, 50-60 Hz  
48-415 VAC, 50 - 60 Hz  
48-510 VAC, 50 - 60 Hz  
L1  
L2  
L3  
L1  
L2  
L3  
L1  
L2  
L3  
L1  
L2  
L3  
Short circuit and overload  
current protection (see page 5)  
Short circuit and overload  
current protection (see page 5)  
/ >  
/ >  
/ >  
/ >  
/ >  
/ >  
/ >  
/ >  
/ >  
L1  
A3  
L2  
L3  
L1  
L2  
L3  
L1  
L2  
L3  
13  
23  
A1  
13  
21  
A1  
13  
23  
A1  
CONTROL  
INPUT  
(Forward)  
CONTROL  
INPUT  
(Reverse)  
DRC3RXXX440XX  
DRC3PXXX433XX  
DRC3PXXX440XX  
IND. CONT. EQ.  
IND. CONT. EQ.  
IND. CONT. EQ.  
CONTROL  
INPUT  
CONTROL  
INPUT  
XXXX  
INPUT  
STATUS  
XXXX  
XXXX  
INPUT  
STATUS  
INPUT  
STATUS  
14  
24  
A2  
14  
22  
A2  
14  
24  
A2  
CONTROL  
INPUT  
T1  
T2  
T3  
T1  
T2  
T3  
T1  
T2  
T3  
(Common)  
Motor Controller /  
AC-53a Application  
T1  
T2  
T3  
T1  
T2  
T3  
T1  
T2  
T3  
General Use /  
AC-51 Application  
Motor Controller /  
AC-53a Application  
T1  
T2  
T3  
T1  
T2  
T3  
T1  
T2  
T3  
M
3
M
Overload current  
protection needs to  
be considered  
3
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM  
DRC3R  
DRC3P  
(3 controlled legs model)  
Main Circuit  
DRC3P  
(2 controlled legs model)  
Main Circuit  
Reverse  
Forward  
Forward  
13  
Reverse  
L1  
L2  
L3  
A3  
L1  
L2  
L3  
A1  
L1  
L2  
L3  
A1  
L1  
L2  
L3  
A1  
23  
14  
24  
T1  
T2  
T3  
A2  
T1  
T2  
T3  
A2  
T1  
T2  
T3  
A2  
T3  
T1  
T2  
A2  
DRC3Rxx440  
models only  
DRC3Pxx440  
(2 Normally Open)  
DRC3Pxx433  
(1 Normally Open - 1 Normally Closed)  
Auxiliary Contacts  
Auxiliary Contacts  
13 23  
13 21  
14 24  
14 22  
INSTALLATION INSTRUCTIONS  
To install on DIN rail  
Install the contactor on the DIN rail (as shown in fig.1).  
Wire the contactor to the input side. AWG #18 (1 mm2) minimum, AWG  
#12 (4 mm2) x 2 maximum.  
Wire the contactor to the output side. AWG #18 (1 mm2) minimum, AWG  
#10 (6 mm2) x 2 (stranded/solid) maximum.  
To remove from  
DIN rail  
Maximum recommended terminal screw torque input 12 lb-in (1.36 Nm)  
& output 15 lb-in (1.7 Nm).  
If multiple units are installed be sure to follow derating curves  
fig. 1  
WARNING! Removing product from 35 mm rail incorrectly by not using the  
appropriate tool could damage the latching system  
fig. 2 Terminal  
screw type.  
Top/Bottom view.  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
SHORT CIRCUIT AND OVERLOAD PROTECTION FOR ALL DEVICES  
(Conforming to the IEC60947-4-2 and UL508)  
IEC standard 60947-4-1 make a distinction between two different types of protection, (called “coordination”), which are designated types “1” and "2".  
Any short-circuit that occurs is cleared safely by either type of coordination.  
The only difference between the 2 categories concerns the extent of the SSR damage caused by the short-circuit.  
Type "1" coordination requires that in the event of a short-circuit, the Solid State Contactor does not endanger personnel or installations,  
but permanent damage to the SSC is permissible. In this case the SSC may need to be replaced. For this type of co-ordination,  
the use of fusing or circuit breakers adequate to protect the system and wiring from short circuits, (but not specifically considering SSC protection), can be used.  
Type "2" coordination requires that under a short-circuit condition, the circuit is interrupted, the SSC does not endanger persons or installations,  
and in addition the SSR will be able to operate after the fault condition is repaired.  
Type of coordination 1  
Protection by Thermal Magnetic Circuit Breaker (18)  
Thermal Magnetic Circuit Breaker Solid State Contactor  
Solid State Contactor  
3 controlled legs  
Solid State Contactor  
Reversing  
Nominal Motor  
Current  
(Schneider Electric)  
GV2ME04 / GV2P04  
GV2ME05 / GV2P05  
GV2ME06 / GV2P06  
GV2ME07 / GV2P07  
GV2ME08 / GV2P08  
GV2ME10 / GV2P10  
GV2ME14 / GV2P14  
2 controlled legs  
0.40-0.63 A  
0.63-1 A  
1-1.6 A  
DRC3Pxx4x2  
DRC3Pxx4x  
DRC3Pxx4x  
DRC3Pxx4x  
DRC3Pxx4x  
DRC3Pxx4x  
DRC3Pxx4x (up to 4.8A)  
-
DRC3Rxx4x  
DRC3Pxx4x2  
DRC3Rxx4x  
DRC3Pxx4x2  
DRC3Rxx4x  
1.6-2.5 A  
2.5-4 A  
DRC3Pxx4x2  
DRC3Rxx4x  
DRC3Pxx4x2  
DRC3Rxx4x  
4-6.3 A  
DRC3Pxx4x2  
DRC3Rxx4x  
6.3-10 A  
DRC3Pxx4x2 (up to 7.6A)  
DRC3Rxx4x (up to 7.6A)  
Protection by overload relays and fuses (18)  
Class gG fuses Solid State Contactor  
Nominal Motor Overload Relay  
Solid State Contactor Solid State Contactor  
(Schneider Electric) (example from Littlefuse) 2 controlled legs  
3 controlled legs  
DRC3Pxx4x  
DRC3Pxx4x  
DRC3Pxx4x  
DRC3Pxx4x  
DRC3Pxx4x  
DRC3Pxx4x(up to 4.8A)  
-
Reversing  
Current  
0.40-0.63 A  
0.63-1 A  
1-1.6 A  
LRD04  
LRD05  
LRD06  
LRD07  
LRD08  
LRD10  
LRD14  
CY14X51G16  
CY14X51G16  
CY14X51G25  
CY14X51G25  
CY14X51G25  
CY14X51G40  
CY14X51G40  
DRC3Pxx4x2  
DRC3Rxx4x  
DRC3Pxx4x2  
DRC3Rxx4x  
DRC3Pxx4x2  
DRC3Rxx4x  
1.6-2.5 A  
2.5-4 A  
DRC3Pxx4x2  
DRC3Rxx4x  
DRC3Pxx4x2  
DRC3Rxx4x  
4-6.3 A  
DRC3Pxx4x2  
DRC3Rxx4x  
6.3-10 A  
DRC3Pxx4x2 (up to 7.6A)  
DRC3Rxx4x (up to 7.6A)  
Type of coordination 2  
Protection by overload relays and fuses (18)  
Semiconductor fuses with less than 1621A2S  
Nominal Motor Overload Relay  
Solid State Contactor  
2 controlled legs  
Solid State Contactor Solid State Contactor  
Ferraz (Cylindric)  
SIBA (Cylindric)  
50.058.06.40  
50.058.06.40  
50.058.06.40  
50.058.06.40  
50.058.06.40  
50.058.06.40  
50.058.06.40  
(Schneider Electric) Littlefuse  
3 controlled legs  
Reversing  
Current  
0.40-0.63 A  
0.63-1 A  
1-1.6 A  
LRD04  
LRD05  
LRD06  
LRD07  
LRD08  
LRD10  
LRD14  
LA50QS40-4  
LA50QS40-4  
LA50QS40-4  
LA50QS40-4  
LA50QS40-4  
LA50QS40-4  
LA50QS40-4  
A093909  
A093909  
A093909  
A093909  
A093909  
A093909  
A093909  
DRC3Pxx4x2  
DRC3Pxx4x  
DRC3Rxx4x  
DRC3Pxx4x2  
DRC3Pxx4x  
DRC3Rxx4x  
DRC3Pxx4x2  
DRC3Pxx4x  
DRC3Rxx4x  
1.6-2.5 A  
2.5-4 A  
DRC3Pxx4x2  
DRC3Pxx4x  
DRC3Rxx4x  
DRC3Pxx4x2  
DRC3Pxx4x  
DRC3Rxx4x  
4-6.3 A  
DRC3Pxx4x2  
DRC3Pxx4x (up to 4.8A)  
-
DRC3Rxx4x  
6.3-10 A  
DRC3Pxx4x2 (up to 7.6A)  
DRC3Rxx4x (up to 7.6A)  
Note: All the Schneider Electric Thermal magnetic circuit breakers GV2 family (GV2ME and GV2P) is fully mechanical compatible with the DRC contactor using the GV2AF3 connection block.  
All the Schneider Electric Overload relay LRD family is fully mechanical compatible with the DRC contactor without the need of any adapter.  
The DRC Series can accept the LAD7C1 module (pre-wiring kit allowing direct connection of the NC contact of relay LRD to the contactor)  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
(19)  
SWITCHING FREQUENCY/LOAD CHARACTERISTIC FOR ALL DEVICES  
IL : Load Operating Current  
IR : Rated Full Load Current [FLA]  
ID : Direct-On-Line Inrush Current  
tL : Load Operating Current Time  
tD : Direct-On-Line Inrush Current Time  
tC : Cycle Time  
ID  
IR  
t
t
On : On Time  
Off : Off Time  
IL  
tD  
tL  
tOn  
tOff  
tC  
MAXIMUM ALLOWABLE NUMBER OF STARTS PER HOUR DEPENDING ON THE STARTING  
TIME tD AND THE ON PERIOD tOn (as for standard IEC 60947-4-2) FOR ALL DEVICES  
Without overload relay (limit given by the contactor itself)  
Table 1  
Table 2  
Table 3  
• Low inrush current (ID/IR < 4 )  
• Full load (IL/IR= 1)  
Table 4  
• Low inrush current (ID/IR < 4 )  
• 60% load (IL/IR= 0.6)  
• High inrush current (ID/IR = 4 to 7.2)  
• Full load (IL/IR= 1)  
• High inrush current (ID/IR = 4 to 7.2)  
• 60% load (IL/IR= 0.6)  
tOn (sec)  
tOn (sec)  
tOn (sec)  
tOn (sec)  
tD (sec)  
0.05  
0.1  
0.1  
5000  
3200  
-
1
10  
100  
35  
35  
35  
35  
35  
30  
25  
tD (sec)  
0.05  
0.1  
0.1  
6000  
4100  
-
1
10  
100  
35  
35  
35  
35  
35  
35  
35  
tD (sec)  
0.05  
0.1  
0.1  
7450  
4050  
-
1
10  
100  
35  
35  
35  
35  
35  
35  
35  
tD (sec)  
0.05  
0.1  
0.1  
1
10  
100  
35  
35  
35  
35  
35  
35  
35  
2700  
1950  
950  
500  
290  
350  
350  
320  
280  
160  
110  
75  
3550  
3000  
1300  
700  
350  
350  
350  
320  
320  
125  
90  
3200  
2100  
1200  
650  
350  
350  
350  
320  
280  
180  
90  
9000  
3550  
3550  
1700  
850  
350  
350  
350  
350  
350  
240  
180  
5400  
0.2  
0.2  
0.2  
0.2  
-
-
-
-
-
-
0.4  
0.4  
0.4  
0.4  
0.8  
0.8  
400  
0.8  
350  
0.8  
560  
-
-
-
1.6  
1.6  
-
-
1.6  
1.6  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.2  
3.2  
3.2  
3.2  
With overload relay (limit given by the overload relay itself)  
Table 5  
Table 6  
Table 7  
• Low inrush current (ID/IR < 4 )  
• Full load (IL/IR= 1)  
Table 8  
• Low inrush current (ID/IR < 4 )  
• 60% load (IL/IR= 0.6)  
• High inrush current (ID/IR = 4 to 7.2)  
• Full load (IL/IR= 1)  
• High inrush current (ID/IR = 4 to 7.2)  
• 60% load (IL/IR= 0.6)  
tOn (sec)  
tOn (sec)  
tOn (sec)  
tOn (sec)  
tD (sec)  
0.05  
0.1  
0.1  
1
10  
330  
280  
255  
150  
60  
100  
30  
28  
26  
24  
20  
16  
tD (sec)  
0.05  
0.1  
0.1  
2800  
1700  
-
1
10  
320  
310  
290  
200  
90  
100  
35  
32  
30  
26  
25  
25  
tD (sec)  
0.05  
0.1  
0.1  
1
10  
100  
35  
34  
33  
32  
30  
25  
20  
tD (sec)  
0.05  
0.1  
0.1  
1
10  
100  
35  
35  
35  
35  
35  
35  
25  
2200  
1650  
1000  
550  
250  
80  
1800  
1300  
650  
300  
200  
5150  
2850  
2800  
1920  
1100  
600  
260  
250  
250  
200  
200  
120  
75  
5600  
3200  
3200  
2700  
1400  
700  
350  
350  
350  
350  
280  
170  
80  
1500  
0.2  
0.2  
0.2  
-
0.2  
-
-
-
-
-
0.4  
0.4  
0.4  
-
-
-
-
0.4  
-
-
-
-
0.8  
0.8  
0.8  
320  
0.8  
350  
-
1.6  
40  
1.6  
65  
1.6  
1.6  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.2  
3.2  
3.2  
3.2  
Note: Please take into consideration the mechanical and electrical life expectancy of the EMR auxiliary contacts when selecting a DRC Series contactor for your  
application.  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
TIMING DIAGRAM  
TIMING DIAGRAM FOR DRC3R  
Input/Output  
1
2
3
4
5
6
7
8
9
10  
Input A1  
Input A3  
100 msec  
100 msec  
FWD Direction  
REV Direction  
100 msec  
interlock  
Input A3  
Input A1  
STEP  
DESCRIPTION  
Initial Condition. A1 & A3 open  
FWD  
REV  
1, 4, 10  
Open  
Close  
Open  
Close  
Open  
Open  
Close  
Close  
Off  
Off  
2
A1 is activated, FWD Output waits for 100msec  
FWD direction is activated  
On  
Off  
Off  
Off  
On  
Off  
3, 9  
4
A1 changes to off. FWD Output is disabled at the same time  
A3 is activated. REV Outputs waits for 100msec  
REV direction is On  
5
6
7
Interlock fuction is activated. REV is disabled due to A1 & A3 both being active  
A3 is open, A1 is closed, activation delayed 100msec  
8
MECHANICAL SPECIFICATIONS  
30.1  
[89]  
Tolerances: ±±0±ꢀ ꢁn ꢂ ±0. ꢃꢃ  
All dꢁꢃensꢁons are ꢁn: ꢁnches [ꢃꢁllꢁꢃeters]  
ꢀ091  
[7309]  
±0ꢀ3  
[.08]  
A3  
13  
23  
A1  
DRC3  
IND. CONT. EQ.  
ꢀ0.8  
[6.0.]  
1068  
[4ꢀ07]  
10ꢀ3  
[3103]  
ꢀ0ꢀ9  
[.803]  
3041  
[8607]  
XXXX  
INPUT  
STATUS  
14  
24  
A2  
3076  
[9.06]  
1078  
[4.03]  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
ACCESSORIES FOR ALL DEVICES  
Recommended Accessories  
Motor Nominal  
Bimetal  
Electronic  
Overload Relay  
Thermal Magnetic Circuit Thermal Magnetic Circuit  
Current  
Overload Relay  
Breaker (Push Button)  
Breaker (Selector)  
0.40 - 0.63 A  
LRD04  
LR97 D015xx  
LR97 D015xx  
LR97 D07xx  
LR97 D07xx  
LR97 D07xx  
LR97 D25xx  
LR97 D25xx  
GV2ME04  
GV2ME05  
GV2ME06  
GV2ME07  
GV2ME08  
GV2ME10  
GV2ME14  
GV2P04  
GV2P05  
GV2P06  
GV2P07  
GV2P08  
GV2P10  
GV2P14  
0.63 - 1 A  
LRD05  
1 - 1.6 A  
LRD06  
1.6 - 2.5 A  
LRD07  
2.5 - 4 A  
LRD08  
4 - 6.3 A  
LRD10  
6.3 - 10 A  
LRD14  
Fully compatible with  
Schneider Electric  
thermal overload  
relays &  
thermal magnetic  
circuit breakers  
Note: All the Schneider Electric Thermal magnetic circuit breakers GV2 family (GV2ME and GV2P) is fully mechanical compatible with the DRC contactor using the GV2AF3 connection block.  
All the Schneider Electric Overload relay LRD family is fully mechanical compatible with the DRC contactor without the need of any adapter.  
The DRC Series can accept the LAD7C1 module (pre-wiring kit allowing direct connection of the NC contact of relay LRD to the contactor)  
When the LAD7C1 module is used, the common terminal for the control input is not anymore the ”A2” terminal of DRC but it is the “96” terminal of the overload relay.  
ID Marker Strips  
CNLB, CNLN, CNL2  
Packages of 10 plastic strips comprising 10  
individual markers which can be placed for easy  
identification during the use of multiple units.  
Blank Strips  
Part no.: CNLB  
Numbered 1 to 10 Strips  
Numbered 11 to 20 Strips  
Part no.: CNLN  
Part no.: CNL2  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
AGENCY APPROVALS, CONFORMANCES AND EMC  
Approvals  
E116949  
Conformances  
United States Standard for Industrial Control Equipment - UL 508 and  
Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14.  
IEC 60068-2-6: Amplitude Range 10-55 Hz, Displacement 0.75 mm  
IEC 60068-2-27: Peak Acceleration 15g, Duration 11ms.  
Vibration Resistance  
Shock Resistance  
Electromagnetic Compatibility  
Generic  
Standard  
Immunity Tests  
Test Specification Level  
Performance  
Electrostatic Discharge  
IEC 61000-4-2  
8kV air discharge  
Criterion A  
Criterion A  
6kV contact discharge  
IEC 61000-6-2  
Immunity for  
Industrial  
Fast transients (burst)  
IEC 61000-4-4  
Output  
Input  
2kV, 5kHz, 100kHz Criterion B  
1kV, 5kHz, 100kHz Criterion A  
1kV Line to Line Criterion B  
2kV Line to Earth Criterion B  
Environments  
Surge  
Output  
IEC 61000-4-5  
GENERAL NOTES  
(1) All parameters at 25°C unless otherwise specified.  
(2) For DRC3P relay will self trigger between 900-1200V, Not suitable for capacitive loads.  
(3) For DRC3R over rated voltage internal self protection will be activated increasing leakage current.  
(4) Mounted in the Vertical position.  
(5) For low temperature operation consider nominal control voltage.  
(6) For DRC3P Instantaneous Turn-on, turn-on time is 4 msec.  
(7) When control signal is completely removed. For DRC3R the turn-off time is 20msec.  
(8) Operating voltage / current on auxiliary contacts must not exceed the power rating (Resistive load).  
(9) For input to auxiliary output the dielectric strength is 1060 Vrms.  
(10) UL approval up to 40°C surrounding temperature.  
(11) Reverse Amber Indicator is for DRC3R models only.  
(12) 100kA, 480VAC, when protected with CC class fuses rated 600VAC, 20 A or equivalent.  
(13) IP20 rating is not associated with the UL approval.  
(14) Derate information is valid when DCR contactors are used with or without accessories, installed on top and/or bottom.  
(15) Minimum spacing to obtain max. current is 22mm between adjacent units.  
(16) For DRC3P models external loads can be connected in parallel to the control input.  
(17) DRC3R internal safety interlock circuit prevents the product to work if any leakage current is present in the control input currently not enabled.  
(18) Combinations of these Protective Devices and Solid State Contactor have not been evaluated by UL.  
(19) Only main circuit, not apply for auxiliary contacts.  
Rev. 071917  
ECN 20277  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险危险  
HAZARD OF  
ELECTRIC  
SHOCK,  
EXPLOSION,  
OR ARC FLASH.  
RIESGO DE  
DESCARGA  
ELECTRICA O  
EXPLOSION.  
RISQUE DE  
GEFAHR EINES  
ELEKTRISCHE  
N SCHLAGES  
ODER EINER  
EXPLOSION.  
RISCHIO DI  
SCOSSA  
ELETTRICA O  
DELL’ESPLOSIONE.  
存在电击、  
爆炸或电弧  
闪烁危险  
DESCHARGE  
ELECTRIQUE  
OU EXPLOSION  
在操作此设  
备之前请先  
关闭电源。  
Eteindre  
toutes les  
sources  
d'énergie de  
cet appareil  
avant de  
travailler  
dessus de cet  
appareil  
Spenga tutta  
l'alimentazione  
che fornisce  
questa  
apparecchiatura  
prima di lavorare  
a questa  
Desconectar  
todos los  
suministros de  
energia a este  
equipo antes  
de trabajar  
Disconnect all  
power before  
installing or  
working with  
this equipment.  
Stellen Sie  
jeglichen  
Strom ab, der  
dieses Gerät  
versorgt, bevor  
Sie an dem  
若不遵守这些说明,  
可能会导致严重的  
人身伤害甚至死亡。  
con este equipo.  
Verify all  
connections  
and replace all  
covers before  
turning on  
Gerät Arbeiten  
durchführen  
apparecchiatura  
Verificar todas  
las conexiones  
y colocar todas  
las tapas antes  
de energizer  
Verificare tutti  
i collegamenti  
e sostituire  
tutte le coperture  
prima  
Vor dem  
Drehen auf  
Energie alle  
Anschlüsse  
überprüfen  
und alle  
Vérifier tous  
connections, et  
remettre tous  
couverts en  
olace avant de  
mettre sous  
power.  
el equipo.  
Failure to follow  
these  
instructions will  
result in death  
or serious injury.  
dell’accensione  
El  
Abdeckungen  
ersetzen.  
L'omissione di  
queste istruzioni  
provocherà la  
morte o  
incumplimiento  
de estas  
instrucciones  
puede provocar  
la muerte o  
lesiones serias.  
De non-suivi de  
ces instructions  
provoquera la  
mort ou des  
lésions sérieuses  
sérieuses.  
Unterlassung  
dieser  
Anweisungen  
können zum  
Tode oder zu  
schweren  
lesioni serie  
Verletzungen  
führen.  
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告  
RISQUE DE DOMMAGE MATERIEL ET DE  
SURCHAUFFE DU BOITIER  
GEFAHR VON MATERIALSCHÄDEN UND  
GEHÄUSEERHITZUNG  
RISK OF MATERIAL DAMAGE AND HOT  
ENCLOSURE  
Les panneaux latéraux du produit peuvent être  
chauds. Laisser le produit refroidir avant de le  
toucher.  
Respecter les consignes de montage, et  
notamment les couples de serrage.  
Ne pas laisser pénétrer de liquide ni de corps  
étrangers à l'intérieur du produit.  
Die Seitenwände können heiß sein. Lassen Sie  
das Produkt abkühlen, bevor Sie es berühren.  
Beachten Sie die Montageanweisungen,  
Führen Sie keine Flüssigkeiten oder  
The product's side panels may be hot, allow  
the product to cool before touching.  
Follow proper mounting instructions including  
torque values.  
Do not allow liquids or foreign objects to enter  
this product.  
Fremdkörper in das Produkt ein.  
Le non-respect de cette directive peut entraîner,  
des lésions corporelles graves ou des  
dommages matériels.  
Die Nichtbeachtung dieser Anweisung kann  
Körperverletzung oder Materialschäden  
zur Folge haben.  
Failure to follow these instructions can result in  
serious injury, or equipment damage.  
RIESGO DE DAÑOS MATERIALES Y DE  
SOBRECALENTAMIENTO DE LA UNIDAD  
材料损和高温外壳的危险性  
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO  
CALDO  
 产品的一侧面板可能很热,在其冷却前请  
 不要触碰。  
 遵照正确的安装说明,包括扭矩值。  
 请勿让液体及其他异物进入本产品。  
Los paneles laterales del producto pueden  
estar calientes. Esperar que el producto se  
enfríe antes de tocarlo.  
Respetar las instrucciones de montaje, y en  
particular los pares de apretado.  
I pannelli laterali dell'apparecchio possono  
scottare; lasciar quindi raffreddare il prodotto  
prima di toccarlo.  
Seguire le istruzioni di montaggio corrette.  
Non far entrare liquidi o oggetti estranei in questo  
apparecchio.  
No dejar que penetren líquidos o cuerpos  
extraños en el producto.  
La mancata osservanza di questa precauzione può  
causare gravi rischi per l'incolumità personale o  
danni alle apparecchiature.  
如不能正确执行这些操作说明,  
极有可能造成严重人体伤害或者设备的损坏。  
Si no se respetan estas precauciones pueden  
producirse graves lesiones, daños materiales.  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
ANNEX - ENVIROMENTAL INFORMATION  
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China  
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.  
Part  
Name  
Toxic or hazardous Substance and Elements  
Lead  
(Pb)  
Mercury  
(Hg)  
Cadmium  
(Cd)  
Hexavalent  
Chromium  
(Cr (VI))  
Polybrominated  
biphenyls  
(PBB)  
Polybrominated  
diphenyl ethers  
(PBDE)  
Semiconductor die  
Solder  
附件 - 环保信息  
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,  
电子信息产品污染控制标识要求。  
部件  
名称  
有毒有害物质或元素  
(Pb)  
(Hg)  
(Cd)  
六价铬  
(Cr (VI))  
多溴联苯  
(PBB)  
多溴二苯醚  
(PBDE)  
半导体芯片  
焊接点  
50  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  

相关型号:

DRD0260115B00A0T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA

DRD0260115B00B00T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA

DRD0260115B20A0T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA

DRD0260115B20B00T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA

DRD0260115B20B0T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA

DRD0260115B20Z00T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA

DRD0260115B40A00T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA

DRD0260115B40A0T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA

DRD0260115B40B00T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA

DRD0260115B40Z00T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA

DRD0260115B40Z0T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA

DRD0260115B60A00T

Disc Type Dielectric Resonator, 23670MHz Min, 25940MHz Max
MURATA