EZ240D5SR [CRYDOM]

Trigger Output SSR, 1-Channel, 4000V Isolation, ROHS COMPLIANT, PLASTIC PACKAGE-4;
EZ240D5SR
型号: EZ240D5SR
厂家: CRYDOM INC.,    CRYDOM INC.,
描述:

Trigger Output SSR, 1-Channel, 4000V Isolation, ROHS COMPLIANT, PLASTIC PACKAGE-4

输出元件 光电
文件: 总2页 (文件大小:49K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series  
EZ  
5-18Amp 120/240, 480 Vac AC OUTPUT  
nect terminals. The Series EZ is the  
preferred choice for replacement of  
120V and 240V Electro-mechanical  
relays. Output consists of an SCR  
Low Leakage  
Quick Connect Terminals  
SCR Output  
switch and is available in Zero-Cross  
and Random Turn-On (Phase  
Controlable) versions.  
24V Control Available  
(EZE Models)  
The Series EZ SPST-NO AC output  
relays offer a low profile package  
with the convenience of quick con-  
Manufactured in Crydoms ISO 9001  
Certified facility for optimum product  
performance and reliability.  
EZ240A12  
EZE240A12  
EZ240A18  
EZE240A18  
EZ480A12  
EZE480A12  
EZ480A18  
EZE480A18  
AC CONTROL (120Vac)  
(24Vac)  
MODEL NUMBERS  
EZ240D5  
DC CONTROL (5Vdc)  
EZ240D12  
EZ240D18  
EZ480D12  
EZ480D18  
(24Vdc)  
EZE240D12  
EZE240D18  
EZE480D12  
EZE480D18  
OUTPUT SPECIFICATIONS  
24-280  
5
Operating Voltage (47-63 Hz) [Vrms]  
24-280  
12  
24-280  
18  
48-660  
12  
48-660  
18  
Max. Load Current [Arms]  
Min. Load Current, [mArms]  
Transient Overvoltage [Vpk]  
Max. Surge Current, (16.6ms) [Apk]  
150  
600  
150  
150  
150  
150  
600  
600  
1200  
1200  
40  
1.5  
2.0  
95  
150  
1.5  
2.0  
95  
200  
1.5  
150  
1.5  
2.0  
95  
200  
1.5  
Max. On-State Voltage Drop @ Rated Current [Vpk]  
Thermal Resistance Junction to Case (R  
) [˚C/W]  
θJC  
2
1.1  
1.1  
2
Maximum I t for Fusing, (8.3 msec.) [A sec]  
170  
170  
Max. Off-State Leakage Current @  
Rated Voltage [mArms]  
0.1  
0.1  
0.1  
0.1  
0.1  
500  
Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec]  
Max. Turn-On Time ➀  
500  
500  
500  
500  
1/2 Cycle (DC Input), 10.0 msec (AC Input)  
1/2 Cycle (DC Input), 40.0 msec (AC Input)  
Max. Turn-Off Time  
0.5  
Power Factor (Min.) with Max. Load  
0.5  
0.5  
0.5  
0.5  
INPUT SPECIFICATIONS ➀  
DC CONTROL  
AC CONTROL  
5Vdc  
5Vdc  
Nominal Voltage  
5Vdc  
24Vdc  
120Vac  
24Vac  
EZE240D12  
EZE240D18  
EZ480D12 EZE480D12  
EZ480D18 EZE480D18  
EZ240A12 EZE240A12  
EZ240A18 EZE240A18  
EZ480A12 EZE480A12  
EZ480A18 EZE480A18  
MODEL NUMBERS  
EZ240D12  
EZ240D18  
EZ240D5  
4-15 Vdc  
4.0 Vdc  
3-15 Vdc  
3.0 Vdc  
Control Voltage Range  
4-15 Vdc  
4.0 Vdc  
15-32 Vdc  
15.0 Vdc  
1.0 Vdc  
90-140 Vrms 18-36 Vrms  
Max. Turn-On Voltage  
90.0 Vrms  
10.0 Vrms  
18.0 Vrms  
2.0 Vrms  
1.0 Vdc  
1.0 Vdc  
Min. Turn-Off Voltage  
1.0 Vdc  
300 Ohms  
13 mAdc  
300 Ohms  
15 mAdc  
Nominal Input Impedance  
Typical Input Current @ Nominal Voltage  
240 Ohms  
15 mAdc  
1500 Ohms  
15 mAdc  
10.6k Ohms 1.8k Ohms  
10 mArms 10 mArms  
GENERAL NOTES  
© 2003 CRYDOM CORP, Specifications subject to change without notice.  
All parameters at 25˚ C unless otherwise specified.  
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1  
240V, DC control models only, all others 2500Vrms.  
Heat sinking required, for derating curves see page 2.  
For recommended applications and more information contact:  
Off-State leakage for snubbered  
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540  
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154  
Email: sales@crydom.com WEB SITE: http://www.crydom.com  
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham  
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.  
GERMANY: +49 (0)180 3000 506  
version (suffix S) is 10.0 mArms.  
Turn-on time for random turn-on versions  
is 0.1 msec (DC Control Models).  
FastFax Document No.160  
SERIES EZ.  
Rev. 111203  
PAGE 1 OF 2  
Series  
EZ  
5
-
18  
Amp 120/240, 480 Vac AC OUTPUT  
GENERAL SPECIFICATIONS  
Dielectric Strength 50/60Hz Input/Output/Base  
Insulation Resistance (Min.) @ 500 Vdc  
Max. Capacitance Input/Output  
4000 Vrms*  
109 Ohm  
8 pF  
Ambient Operating Temperature Range  
Ambient Storage Temperature Range  
-40 to 80˚C  
-40 to 125˚C  
MECHANICAL SPECIFICATIONS  
Weight: (typical)  
1.5 oz. (43g)  
Encapsulation:  
Terminals:  
Thermally Conductive Epoxy  
.25 Inch Faston  
*240V, DC Control Models Only.  
2.63  
(66.8)  
AVAILABLE OPTIONS  
2.24  
S
Internal Snubber  
Example: EZ240D12S  
.197 DIA.  
(2 PLCS)  
(56.9)  
OUTPUT  
INPUT  
R
Random Turn-On Switching  
Example: EZ240D12R, EZ240D12RS  
EZ240D5R  
1.50  
1
2
PIN 1: AC LOAD  
PIN 2: AC LOAD  
PIN 3: +DC CONTROL  
PIN 4: --DC CONTROL  
(38.1)  
1.00  
(25.4)  
.49  
(12.4)  
3+  
4
FASTON  
TERMINAL  
.250 X .032  
4 PLCS.  
.40  
(10.2)  
1.73  
(43.9)  
.12  
(3.0)  
Crydom Heat Sinks offer excellent ther-  
mal management and are perfectly  
matched to the load current ratings of  
Crydom panel mount relays. Request  
Crydoms Heat Sink specification sheet for  
all the details.  
.95  
(24.1)  
All dimensions are in inches (millimeters)  
C U R R E N T D E R A T I N G C U R V E S  
12A  
5A  
18A  
15  
6
18  
12  
6
2˚C/W  
112  
10˚C/W  
2˚C/W  
112  
116  
120  
124  
5
4
3
2
110  
115  
120  
4˚C/W  
5˚C/W  
10  
6˚C/W  
116  
5˚C/W  
NO HEATSINK  
NO HEATSINK  
NO HEATSINK  
120  
124  
5
0
1
0
2
4
6
8 10 12 20 40 60 80  
Load Current [Arms] Max Ambient Temp. [˚C]  
3
6
9 12 15 18 20 40 60 80  
Load Current [Arms] Max Ambient Temp. [˚C]  
1
2
3
4
Load Current [Arms]  
5
10 20 40 60 80  
Max Ambient Temp. [˚C]  
© 2003 CRYDOM CORP, Specifications subject to change without notice.  
APPROVALS  
UL  
E116950  
CSA LR81689  
VDE 10139 UG (240V DC Control Only)  
For recommended applications and more information contact:  
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540  
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154  
Email: sales@crydom.com WEB SITE: http://www.crydom.com  
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham  
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.  
GERMANY: +49 (0)180 3000 506  
FastFax Document No.160  
SERIES EZ  
Rev. 111203  
PAGE 2 OF 2  

相关型号:

EZ290

Gen II LEDs
MARKTECH

EZ290_15

Gen II LEDs
MARKTECH

EZ3-A230X

Surge arrester 3-electrode arrester
EPCOS

EZ3-A230XF1

Surge arrester 3-electrode arrester
EPCOS

EZ3-A250X

Surge arrester 3-electrode arrester
EPCOS

EZ3-A250XF1

Surge arrester 3-electrode arrester
EPCOS

EZ3-A350XF1

Surge arrester 3-electrode arrester
EPCOS

EZ3-A90X

Surge arrester 3-electrode arrester
EPCOS

EZ30

EzFlex Thermo-Anemometer
EXTECH

EZ40

EzFlex Combustible Gas Leak Detector
EXTECH

EZ400

Gen II LED
MARKTECH

EZ400_15

Gen II LED
MARKTECH