HA / HD48 Series
• Ratings from 12A to 125A @ 48-530 VAC
• SCR output for heavy industrial loads
• AC or DC control
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
• Zero Voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
For Generation 3 datasheet click here
PRODUCT SELECTION
Control Voltage
4-32 VDC
90-280 Vrms
18-36 Vrms
12A
HD4812
HA4812
HA4812E
25A
HD4825
HA4825
HA4825E
50A
HD4850
HA4850
HA4850E
75A
HD4875
HA4875
HA4875E
90A
HD4890
HA4890
HA4890E
110A
HD48110
HA48110
HA48110E
125A
HD48125
HA48125
HA48125E
AVAILABLE OPTIONS
Control Voltage
A: 90-280 VAC
D: 4-32 VDC
AxxxxE: 18-36 VAC
Overvoltage Protection
Blank: Not Included
P: Included (3)
Snubber
Blank: Not Included
S: Included
Switching Type
Blank: Zero Voltage Turn-On
(4)
Series
-10: Instantaneous Turn-On
H
A
E
K
P
G
S
H
-10
48
Operating
Voltage
25
Rated Load Current
Termination
Input Status LED
Thermal Pad
12: 12 Amps
Blank: Screw
Blank: Not Included
Blank: Not Included
48: 48-530 VAC 25: 25 Amps
50: 50 Amps
F: Quick Connect (1)
(Up to 50 Amps models)
K: Hex standoffs (2)
G: Included
H: Included
75: 75 Amps
90: 90 Amps
110: 110 Amps
125: 125 Amps
Required for valid part number
For options only and not required for valid part number
Not all part number combinations are available.
Contact Crydom Technical Support for information on
the availability of a specific part number.
*
OUTPUT SPECIFICATIONS (5)
Description
12A
48-530
1200
1
500
12
25A
48-530
1200
1
500
25
50A
48-530
1200
1
500
50
75A
48-530
1200
1
500
75
90A
48-530
1200
1
500
90
110A
48-530
1200
1
500
125A
48-530
1200
1
500
Operating Voltage (47-440Hz) [Vrms] (6)
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms] (7)
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
Maximum Load Current [Arms] (2)(8)
110
125
Minimum Load Current [mArms]
150
150
150
150
150
150
150
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vrms]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]
Minimum Power Factor (at Maximum Load) (3)
134/140
1.15
1.03
66/60
0.5
239/250
1.15
0.8
285/259
0.5
597/625
1.15
0.45
1770/1629
0.5
954/1000
1.15
0.3
4555/4150
0.5
1145/1200
1.15
0.27
6560/5976
0.5
1432/1500
1.15
0.25
10249/9338
0.5
1670/1750
1.15
0.22
13950/12709
0.5
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
INPUT SPECIFICATIONS (5)
Description
HD48xx
4-32 VDC (9)
4.0 VDC
1.0 VDC
-32 VDC
7.0 mA
HA48xx
HA48xxE
18-36 Vrms
18 Vrms
4.0 Vrms
-
Control Voltage Range
90-280 Vrms
Minimum Turn-On Voltage
Must Turn-Off Voltage
90 Vrms
10 Vrms
-
Maximum Reverse Voltage
Minimum Input Current
Maximum Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
5 mA
10 mA
Current Regulated
16 mA
20 mA
12 mA
(10)
1/2 Cycle
1/2 Cycle
20
30
20
30
GENERAL SPECIFICATIONS (5)
Description
Parameters
4000 Vrms
109 Ohm
8 pF
-40 to 80 °C
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
-40 to 125 °C
2.6 oz (74.9 g)
Housing Material
UL94 V-0
Baseplate Material
Aluminum
Input Terminal Screw Torque Range (in-lb/Nm)
Load Terminal Screw Torque Range (in-lb/Nm)
SSR Mounting Screw Torque Range (in-lb/Nm)
Input/Load Terminal Screw Torque Range (in-lb/Nm) (2)
Input/Output Terminal Screw Thread Size
13-15 /1.5-1.7
18-20 / 2.0-2.2
18-20 / 2.0-2.2
w/”K” option 8-10 / 0.9-1.13
#6-32 UNC / #8-32 UNC
Humidity per IEC60068-2-78
LED Input Status indicatior
93% non-condensing
w/”G” option (green)
11,641,553 hours (1,328 years)
7,210,376 hours (823 years)
MTBF (Mean Time Between Failures) at 40°C ambient temperature (11)
MTBF (Mean Time Between Failures) at 60°C ambient temperature (11)
WIRING DIAGRAM
AC
Input Current vs Input Voltage
Recommended Wire Sizes
V
Wire Size
(Solid / Stranded)
Wire Pull-Out
Strength (lb)[N]
25
20
Terminals
Input
Load (12)
2 (
24 AWG (0.2 mm2) / 0.2 [minimum]
2 x 12 AWG (3.3 mm2) / 3.3 [maximum]
20 AWG (0.5 mm2) / 0.518 [minimum]
2 x 10 AWG (5.3 mm2) / 5.3
10 [44.5]
1 (
)
)
15
10
5
90 [400]
30 [133]
Output
2
3
110 [490]
90 [400]
1
OUTPUT
S O L I D S T AT E R E L AY
2 x 8 AWG (8.4 mm2) / 8.4 [maximum]
0
0
5
10
15
20
25
30
4
INPUT
DC Input Voltage
4 (– / )
3 (+ / )
EQUIVALENT CIRCUIT BLOCK DIAGRAMS
Diagram: HAxxxx
Diagram: HDxxxx
4
1
2
4
3
1
2
AC
AC
AC
-
DC
AC
AC
Current
Limiter
(13)
AC/DC
Converter
Trigger
Circuit
Trigger
Circuit
(14)
(14)
(15)
(15)
(13)
AC
3
+DC
Current
Limiter
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
MECHANICAL SPECIFICATIONS ()
Tolerances: 0.02 ꢀn ꢁ 0.5 ꢂꢂ
All dꢀꢂensꢀons are ꢀn: ꢀnches [ꢂꢀllꢀꢂeters]
(2)
Screw Termination
Hex Standoff Termination (“K” Option)
1.1
1.1
Mounting
0.89
[22.6]
[27.9]
1.04
[26.4]
[27.9]
Hole/Slot
0.19 [4.9]
DIA.
Mounting
0.49
[12.4]
0.49
[12.4]
Hole/Slot
0.19 [4.9]
DIA.
2
3
1
OUTPUT
2
3
1
OUTPUT
S O L I D S T AT E R E L AY
2.25
[57.3]
1.70
[43.2]
1.88
[47.6]
S O L I D S T AT E R E L AY
2.25
[57.3]
1.88
[47.6]
1.7
[43.2]
4
INPUT
4
INPUT
0.93
[23.6]
1.0
1.0
[25.4]
[25.4]
(4 places)
1.75
[44.5]
1.75
[44.5]
1.0
[25.4]
(2 places)
Quick Connect Termination (“F” Option) - Up to 25 Amp (1)
Quick Connect Termination (“F” Option) - Up to 50 Amp (1)
Faston Terminal(16)
0.25 x 0.032
1.58
1.58
[40.2]
0.63
1.31
[33.4]
1.31
[33.4]
Faston Terminal(16)
0.25 x 0.032
[40.2]
Mounting
Hole/Slot
0.19 [4.9]
DIA.
Mounting
Hole/Slot
0.19 [4.9]
DIA.
(4 places)
0.49
[12.4]
(2 places)
[16.0]
0.45
[11.4]
(2 places)
2
3
1
OUTPUT
2
3
1
OUTPUT
S O L I D S T AT E R E L AY
S O L I D S T AT E R E L AY
2.25
[57.3]
1.88
[47.6]
1.7
[43.2]
2.25
[57.3]
1.88
[47.6]
1.7
[43.2]
4
INPUT
4
INPUT
0.49
1.40
Faston Terminal(16)
0.187 x 0.020
[12.4]
[35.6]
Faston Terminal(16)
0.187 x 0.020
1.40
[35.6]
1.75
1.25
[31.8]
1.75
[44.5]
1.25
[31.8]
(2 places)
(2 places)
[44.5]
GENERAL NOTES
(1) Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect both pairs.
(2) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50
Amps. For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support.
(3) Output will self trigger between 900-1200Vpk, Min. power factor 0.7 or higher, not suituable for capacitive loads.
(4) Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only.
(5) All parameters at 25°C unless otherwise specified.
(6) For “S” option, operating voltage frequency is 47-63Hz.
(7) For parts with option “S” maximum leakage current is 10mA.
(8) Heat sinking required, see derating curves.
(9) Increase minimum voltage by 1V for operations from -20 to -40°C.
(10) Turn-on time for instantaneous turn-on versions is 0.02 msec (DC Control Models)
(11) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).
(12) Load can be wired to either SSR output terminal 1 or 2.
(13) Elective Input Status LED, “G” option
(14) Elective Overvoltage Protection, “P” option.
(15) Elective Internal Snubber, “S” option.
(16) Mechanical dimensions vary from G3 models.
For additional information or specific questions, contact Crydom Technical Support.
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
SURGE CURRENT INFORMATION
12 A
25 A
120
250
100
80
60
40
20
0
200
150
100
50
0
0.01
0.01
0.1
0.1
0.1
1
10
10
10
0.1
0.1
0.1
1
10
10
10
Surge Duration (Secs)
Surge Duration (Secs)
50 A
75 A
600
900
800
700
600
500
400
300
200
100
0
500
400
300
200
100
0
0.01
1
0.01
1
Surge Duration (Secs)
Surge Duration (Secs)
90 A
110 A
1200
1050
900
750
600
450
300
150
0
1500
1200
900
600
300
0
0.01
1
0.01
1
Surge Duration (Secs)
Surge Duration (Secs)
125 A
1800
1600
1400
1200
1000
800
600
400
200
0
0.01
0.1
1
10
Surge Duration (Secs)
Non repetitive peak surge current at Tj initial 40ºC.
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
THERMAL DERATE INFORMATION
12 A
25 A
50 A
3ºC/W
5ºC/W
1.5ºC/W
2ºC/W
0.7ºC/W
1ºC/W
No heatsink
3ºC/W
1.5ºC/W
2ºC/W
12
10
8
25
20
15
10
5
50
40
30
20
10
0
6
4
2
0
0
20
30
40
50
60
70
80
20
20
20
30
40
50
60
70
80
20
30
40
50
60
70
80
Ambient Temperature (ºC)
Ambient Temperature (ºC)
Ambient Temperature (ºC)
75 A
90 A
110 A
0.5ºC/W
0.7ºC/W
0.5ºC/W
0.7ºC/W
0.5ºC/W
0.7ºC/W
1ºC/W
1.5ºC/W
1ºC/W
1.5ºC/W
1ºC/W
1.5ºC/W
90
80
70
60
50
40
30
20
10
0
75
60
45
30
15
0
120
100
80
60
40
20
0
20
30
40
50
60
70
80
30
40
50
60
70
80
20
30
40
50
60
70
80
Ambient Temperature (ºC)
Ambient Temperature (ºC)
Ambient Temperature (ºC)
125 A
0.5ºC/W
0.7ºC/W
1ºC/W
120
100
80
60
40
20
0
30
40
50
60
70
80
Ambient Temperature (ºC)
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
IEC 61000-4-2 : Electrostatic Discharge – Level 3
IEC 61000-4-4 : Electrically Fast Transients – Level 3
IEC 61000-4-5 : Electrical Surges – Level 3
IEC 600068-2-6: Vibration 0.33mm and 0.75mm Amplitude over 10-55 Hz
IEC 600068-2-27: Shock Resistance 15g/11ms
E116949
E116950 (110 and 125A models)
LR81689 (except 12, 110 and 125A models)
10143 UG
ACCESORIES
Recommended Accessories
New Accessories!
Protective Cover & Hardware Kits
Protective Cover
Part number: KS101
Cover
Hardware
Kit
Heat Sink
Part No.
Thermal Resistance Lug Terminal Thermal Pad
[ºC/W]
Clear plastic cover compatible with all new
S1 designs. Safety covers provide added
protection from electric shock when
installing or checking equipment.
5.0
HS501DR
KS101
HK1
HK4
TRM1
TRM6
HSP-1
HSP-2
3.0
HS301 / HS301DR
HS251
2.5
2.0
HS202 / HS202DR
HS201 / HS201DR
HS172
2.0
Hardware Kit
1.7
Part number: HK4
HS151 / HS151DR
HS122 / HS122DR
HS103 / HS103DR
HS101
1.5
Bag with 2 square brass accessories and 2
screw 8-32 x 5/8 for output. Used to mount
TMR1 lug terminals.
1.2
1.0
1.0
HS073
0.7
HS072
0.7
HS053
0.5
HS033
0.36
0.25
HS023
Rev. 040716
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
RISQUE DE
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSIONE.
存在电击、
爆炸或电弧
闪烁危险
DESCHARGE
ELECTRIQUE
OU EXPLOSION
•
在操作此设
备之前请先
关闭电源。
• Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
• Spenga tutta
l'alimentazione
che fornisce
questa
apparecchiatura
prima di lavorare
a questa
• Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
• Disconnect all
power before
installing or
working with
this equipment.
• Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
若不遵守这些说明,
可能会导致严重的
人身伤害甚至死亡。
con este equipo.
• Verify all
connections
and replace all
covers before
turning on
Gerät Arbeiten
durchführen
apparecchiatura
• Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
• Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima
• Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
• Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
power.
el equipo.
Failure to follow
these
instructions will
result in death
or serious injury.
dell’accensione
El
Abdeckungen
ersetzen.
L'omissione di
queste istruzioni
provocherà la
morte o
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
lesioni serie
Verletzungen
führen.
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
• Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
• Respecter les consignes de montage, et
notamment les couples de serrage.
• Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
• Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
• Beachten Sie die Montageanweisungen,
• Führen Sie keine Flüssigkeiten oder
• The product's side panels may be hot, allow
the product to cool before touching.
• Follow proper mounting instructions including
torque values.
• Do not allow liquids or foreign objects to enter
this product.
Fremdkörper in das Produkt ein.
Le non-respect de cette directive peut entraîner,
des lésions corporelles graves ou des
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
Failure to follow these instructions can result in
serious injury, or equipment damage.
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
材料损坏和高温外壳的危险性
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
• 产品的一侧面板可能很热,在其冷却前请
不要触碰。
• 遵照正确的安装说明,包括扭矩值。
• 请勿让液体及其他异物进入本产品。
• Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
• Respetar las instrucciones de montaje, y en
particular los pares de apretado.
• I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
• Seguire le istruzioni di montaggio corrette.
• Non far entrare liquidi o oggetti estranei in questo
apparecchio.
• No dejar que penetren líquidos o cuerpos
extraños en el producto.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
如不能正确执行这些操作说明,
极有可能造成严重人体伤害或者设备的损坏。
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
ANNEX - ENVIROMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part
Name
Toxic or hazardous Substance and Elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr (VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,
电子信息产品污染控制标识要求。
部件
名称
有毒有害物质或元素
铅
(Pb)
汞
(Hg)
镉
(Cd)
六价铬
(Cr (VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
半导体芯片
焊接点
50
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
相关型号:
©2020 ICPDF网 联系我们和版权申明