MS11-CMX [CRYDOM]

3 -10 Amp 0-200 Vdc DC Output; 3 -10安培0-200伏直流输出
MS11-CMX
型号: MS11-CMX
厂家: CRYDOM INC.,    CRYDOM INC.,
描述:

3 -10 Amp 0-200 Vdc DC Output
3 -10安培0-200伏直流输出

文件: 总6页 (文件大小:214K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series MS11-CMX  
3 -10 Amp • 0-200 Vdc • DC Output  
DC output SPST-NO solid state relays  
use MOSFET output for high switching  
capabilities in a DIN Rail (TS-35) mount  
air-cooled package.  
• DIN Rail Mount (TS 35)  
• MOSFET Output  
Extra Low On State  
Resistance  
• Input Status LED  
MODEL NO.  
MS11-CMX60D5  
MS11-CMX60D10  
MS11-CMX100D6  
MS11-CMX200D3  
INPUT SPECIFICATIONS  
1
5-10 Vdc  
300 Ohm  
12 mA  
Control Voltage Range  
5-10 Vdc  
300 Ohm  
12 mA  
5-10 Vdc  
300 Ohm  
12 mA  
6-10 Vdc  
300 Ohm  
12 mA  
Nominal Input Impedance  
Typical Input Current @ 5 Vdc  
Must Turn On Voltage  
5 Vdc  
5 Vdc  
5 Vdc  
6 Vdc  
1.0 Vdc  
Must Turn Off Voltage  
1.0 Vdc  
1.0 Vdc  
1.0 Vdc  
13  
OUTPUT SPECIFICATIONS  
Operating Voltage Range  
Load Current Range  
0-100 Vdc  
0-6 Adc  
100 Apk  
0-60 Vdc  
0-5 Adc  
60 Apk  
0-60 Vdc  
0-10 Adc  
100 Apk  
0-200 Vdc  
0-3 Adc  
30 Apk  
Max. Surge Current, (10 msec)  
Max.Off-State Leakage  
@ Rated Voltage  
4
100 µAdc  
.10 Ohm  
100 µAdc  
100µAdc  
.040 Ohm  
100 µAdc  
.20 Ohm  
Max. On-State Resistance  
.018 Ohm  
0.18V  
)
@ Rated Current (R DS-ON  
Max. On-State Voltage Drop  
@ Rated Current  
0.5V  
0.24V  
0.6V  
1.0 msec  
300 µsec  
Max.Turn-On Time @ 10Vdc Control  
Max. Turn-Off TIme @ 10Vdc Control  
1.0 msec  
300 µsec  
1.0 msec  
300 µsec  
1.0 msec  
300 µsec  
© 2007 CRYDOM Inc., Specifications subject to change without notice.  
G E N E R A L N O T E S  
All parameters at 25ºC unless otherwise specified.  
1
Dielectric and insulation resistance are  
2measured between input and output.  
Inductive loads should be diode suppressed.  
At 55 Vdc.  
3
4
For recommended applications and more information contact:  
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540  
Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154  
Email: sales@crydom.com WEB SITE: http://www.crydom.com  
UK: +44 (0)1202 606030 • FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,  
Holyrood Close, Poole, Dorset BH17 7FJ, Email: intsales@crydom.com.  
GERMANY: +49 (0)180 3000 506  
SERIES MS11-CMX.  
Rev. 110707  
PAGE 1 OF 3  
Series MS11-CMX  
3 -10 Amp • 0-200 Vdc • DC Output  
G E N E R A L S P E C I F I C A T I O N S  
2
Dielectric Strength  
2500 Vrms  
9
2
Insulation Resistance (Min.) @ 500 Vdc  
Max. Capacitance (Input/Output)  
10 Ohm  
15 pF  
Ambient Operating Temperature Range  
Ambient Storage Temperature Range  
-30 to 80°C  
-30 to 125°C  
M E C H A N I C A L S P E C I F I C A T I O N S  
Weight: (typical)  
30 g  
Encapsulation(SSR):  
Thermally Conductive Epoxy  
C U R R E N T D E R A T I N G C U R V E S  
7.0  
6.0  
CMX100D6  
5.0  
CRYDOM  
Solid State Relay  
CMX60D5  
4.0  
-A2 +A1  
3.0  
CMX Series  
CMX200D3  
2.0  
Input  
Output  
1.0  
0
20  
40  
60  
80  
AMBIENT TEMPERATURE [ °C ]  
12.0  
10.0  
8.0  
6.0  
4.0  
2.0  
0
DIN Rail TS35  
85.0  
12.5  
CMX60D10  
All dimensions are in millimeters (not to scale)  
Colour of carrier including terminations - orange  
20  
40  
60  
80  
AMBIENT TEMPERATURE [ °C ]  
Max. Load Current vs. Temp.  
© 2007 CRYDOM Inc., Specifications subject to change without notice.  
APPROVALS (SSR ONLY)  
UL E116950 (3A, 6A & 10A Models)  
For recommended applications and more information contact:  
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540  
Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154  
Email: sales@crydom.com WEB SITE: http://www.crydom.com  
UK: +44 (0)1202 606030 • FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,  
Holyrood Close, Poole, Dorset BH17 7FJ, Email: intsales@crydom.com.  
GERMANY: +49 (0)180 3000 506  
SERIES MS11-CMX.  
Rev. 110707  
PAGE 2 OF 3  
S
eries MS11-CX  
5 Amp• 240 Vac• AC Output  
Crydom's family of SPST-NO relays  
achieves the highest power switching  
capability in a DIN mounted air-cooled  
package. Advanced features include  
exceptional steady state current, plus  
ultra-high surge ratings. Models are  
available to switch up to 280 Vrms with  
AC or DC control, and either zero-cross  
or random turn-on ("R") switching ver-  
sions.  
DIN Rail Mount (TS-35)  
S
CR  
O
utput  
igh  
rydom  
R
ating  
urge  
atented  
U
ltra  
H
S
C
s  
P
Design  
Input Status LED  
MS11-CX2405  
MS11-CXE240  
A
A
C CONTROL (120Vac)  
(24Vac)  
A
5
MODEL NUMBERS  
DC CONTROL (5Vdc)  
(24Vdc)  
MS11-CX240  
D5  
MS11-CXE240  
D
5
1
OUTPUT SPECIFICATIONS  
Operating Voltage (47-63 Hz) [Vrms]  
Load Current Range [Arms]  
12-280  
.06-5  
600  
Transient Overvoltage [Vpk]  
250  
Max. Surge Current, (16.6ms) [Apk]  
1.4  
Max. On-State Voltage Drop @ Rated Current [Vpk]  
2
2
260  
0.1  
Maximum I t for Fusing, (8.3 msec.) [A sec]  
Max. Off-State Leakage Current @ Rated Voltage [mArms]  
2
500  
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]  
3
Max. Turn-On Time  
1/2 Cycle (DC Control), 10.0 msec (AC Control)  
1/2 Cycle (DC Control), 40.0 msec (AC Control)  
0.5  
Max. Turn-Off Time  
Power Factor (Min.) with Max. Load  
4
1
AC CONTROL  
INPUT SPECIFICATIONS  
DC CONTROL  
24Vac  
Nominal Voltage  
24Vdc  
120Vac  
5Vdc  
MODEL NUMBERS  
MS11-CX240A5  
MS11-CX240D5  
MS11-CXE240A5  
MS11-CXE240D5  
4-5 Vdc  
3.0 Vdc  
1.0 Vdc  
300 Ohm  
12 mA  
Control Voltage Range  
15-32 Vdc  
15.0 Vdc  
1.0 Vdc  
1.0k Ohm  
8 mA  
90-140 Vrms  
90.0 Vrms  
10.0 Vrms  
14.1k Ohm  
10 mArms  
18-36 Vrms  
18.0 Vrms  
2.0 Vrms  
Max. Turn-On Voltage  
Min. Turn-Off Voltage  
Nominal Input Impedance  
Typical Input Current @ Nominal Voltage  
GENERAL NOTES  
4.2k Ohm  
5 mArms  
© 2005 CRYDOM CORP, Specifications subject to change without notice.  
1 All parameters at 25ºC unless otherwise specified.  
2 Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1  
Turn-On Time for Random Turn-On versions 0.1msec (DC Control Models).  
3
No input status LED on AC control modules.  
4
For recommended applications and more information contact:  
USA: Sales Support (877) 502-5500 •Tech Support (877) 702-7700 • FAX (619) 710-8540  
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154  
Email: sales@crydom.com • WEB SITE: http://www.crydom.com  
UK: +44 (0)1202 365070 • FAX: +44 (0)1202 365090 Crydom International Ltd., 7 Cobham  
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.  
GERMANY: +49 (0)180 3000 506  
SERIES MS11-CX.  
Rev. 012505  
PAGE 1 OF 2  
S
eries MS11-CX  
5Amp • 240 Vac • AC Output  
GENERAL SPECIFICATIONS  
Dielectric Strength 50/60Hz Input/Output/Base  
Insulation Resistance (Min.) @ 500 Vdc  
Max. Capacitance Input/Output  
2500 Vrms  
10 9 Ohm  
10 pF  
Ambient Operating Temperature Range  
Ambient Storage Temperature Range  
-30 to 80ºC  
-30 to 80ºC  
MECHANICAL SPECIFICATION  
Weight: (typical)  
30 grms  
Encapsulation (SSR):  
Thermally Conductive Epoxy  
CURRENT DERATING CURVE  
6.0  
5.0  
4.0  
3.0  
2.0  
1.0  
0
CRYDOM  
Solid State Relay  
-A2 +A1  
CX Series  
Input Output  
DIN Rail TS35  
20  
40  
60  
80  
AMBIENT TEMPERATURE [ C]  
85.0  
All dimensions are in millimeters (not to scale)  
12.5  
Max. Load Current vs. Temp.  
Colour of carrier and termination housing - orange  
Input status LED is on DC control module only  
© 2005 CRYDOM CORP, Specifications subject to change without notice.  
AVAILABLE OPTIONS  
R
Random Turn-On Switching  
Example: MS11- X240D5R, MS11-CX240A5R  
C
APPROVALS ( SSR ONLY )  
UL  
E 116949  
CSA LR 81689  
VDE 70938  
UG (240V, DC Control Only)  
For recommended applications and more information contact:  
USA: Sales Support (877) 502-5500 •Tech Support (877) 702-7700 • FAX (619) 710-8540  
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154  
Email: sales@crydom.com • WEB SITE: http://www.crydom.com  
UK: +44 (0)1202 365070 • FAX: +44 (0)1202 365090 Crydom International Ltd., 7 Cobham  
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.  
GERMANY: +49 (0)180 3000 506  
SERIES MS11-CX  
Rev. 012405  
PAGE 2 OF 2  
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO  
HAZARD OF  
ELECTRIC  
SHOCK,  
EXPLOSION,  
OR ARC FLASH.  
RIESGO DE  
DESCARGA  
ELECTRICA O  
EXPLOSION.  
RISQUE DE  
GEFAHR EINES  
ELEKTRISCHE  
N SCHLAGES  
ODER EINER  
EXPLOSION.  
RISCHIO DI  
SCOSSA  
ELETTRICA O  
DELL’ESPLOSI  
ONE.  
RISCO DE  
DESCHARGE  
ELECTRIQUE  
OU EXPLOSION  
DESCARGA  
ELÉTTRICA OU  
EXPLOSÃO  
Desconectar  
o equipamento  
de toda á  
energia antes  
de instalar ou  
trabalhar com  
este equipamen  
to  
Eteindre  
toutes les  
sources  
d'énergie de  
cet appareil  
avant de  
travailler  
dessus de cet  
appareil  
Desconectar  
todos los  
suministros de  
energia a este  
equipo antes  
de trabajar  
Disconnect all  
power before  
installing or  
working with  
this equipment.  
Stellen Sie  
jeglichen  
Strom ab, der  
dieses Gerät  
versorgt, bevor  
Sie an dem  
Spenga tutta  
l'alimentazion  
e che fornisce  
questa  
apparecchiatu  
ra prima del  
con este equipo.  
Verify all  
connections  
and replace all  
covers before  
turning on  
Gerät Arbeiten  
durchführen  
lavorare a questa  
Verificar todas  
las conexiones  
y colocar todas  
las tapas antes  
de energizer  
apparecchiatu ra  
Verificar todas  
as conexões e  
recolocar todas  
as tampas  
antes de religar  
o equipamento  
Vor dem  
Drehen auf  
Energie alle  
Anschlüsse  
überprüfen  
und alle  
Verificare tutti  
i collegamenti  
e sostituire  
tutte le coperture  
prima della  
Vérifier tous  
connections, et  
remettre tous  
couverts en  
olace avant de  
mettre sous  
power.  
el equipo.  
Failure to follow  
these  
instructions will  
result in death  
or serious injury.  
El  
rotazione  
sull'alimentazi one  
Abdeckungen  
ersetzen.  
incumplimiento  
de estas  
instrucciones  
puede provocar  
la muerte o  
lesiones serias.  
O não cumprimento  
destas instruções  
pode levar á morte  
ou lesões sérias.  
De non-suivi de  
ces instructions  
provoquera la  
mort ou des  
lésions sérieuses  
sérieuses.  
L'omissione di  
seguire queste  
istruz ioni  
provocherà la  
morte o di  
Unterlassung  
dieser  
Anweisungen  
können zum  
Tode oder zu  
schweren  
lesioni serie  
Verletzungen  
führen.  
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / AVISO  
RISQUE DE DOMMAGE MATERIEL ET DE  
SURCHAUFFE DU BOITIER  
GEFAHR VON MATERIALSCHÄDEN UND  
GEHÄUSEERHITZUNG  
RISK OF MATERIAL DAMAGE AND HOT  
ENCLOSURE  
Les panneaux latéraux du produit peuvent être  
chauds. Laisser le produit refroidir avant de le  
toucher.  
Respecter les consignes de montage, et  
notamment les couples de serrage.  
Ne pas laisser pénétrer de liquide ni de corps  
étrangers à l'intérieur du produit.  
Die Seitenwände können heiß sein. Lassen Sie  
das Produkt abkühlen, bevor Sie es berühren.  
Beachten Sie die Montageanweisungen,  
Führen Sie keine Flüssigkeiten oder  
The product's side panels may be hot, allow  
time for product to cool before touching.  
Follow proper mounting instructions including  
torque values.  
Do not allow liquids or foreign objects to enter  
this product.  
Fremdkörper in das Produkt ein.  
Le non-respect de cette directive peut entraîner,  
des lésions corporelles graves ou des  
dommages matériels.  
Die Nichtbeachtung dieser Anweisung kann  
Körperverletzung oder Materialschäden  
zur Folge haben.  
Failure to follow this instruction can result in  
serious injury, or equipment damage.  
RIESGO DE DAÑOS MATERIALES Y DE  
SOBRECALENTAMIENTO DE LA UNIDAD  
RISCO DE DANO MATERIAL E DE AQUECIMENTO  
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO  
CALDO  
Os painéis laterais do produto podem estar  
quentes; dê tempo ao produto para arrefecer  
antes de lhe tocar.  
Siga devidamente as instruções de montagem.  
Não permita a entrada de líquidos e de objectos  
estranhos no produto.  
Los paneles laterales del producto pueden  
estar calientes. Esperar que el producto se  
enfríe antes de tocarlo.  
Respetar las instrucciones de montaje, y en  
particular los pares de apretado.  
I pannelli laterali dell'apparecchio possono  
scottare; lasciar quindi raffreddare il prodotto  
prima di toccarlo.  
Seguire le istruzioni di montaggio corrette.  
Non far entrare liquidi o oggetti estranei in questo  
apparecchio.  
No dejar que penetren líquidos o cuerpos  
extraños en el producto.  
La mancata osservanza di questa precauzione può  
causare gravi rischi per l'incolumità personale o  
danni alle apparecchiature.  
A não observância destas precauções pode  
provocar a morte, ferimentos graves ou  
danos materiais.  
Si no se respetan estas precauciones pueden  
producirse graves lesiones, daños materiales.  
SERIES MS11-CMX.  
Rev. 110707  
PAGE 3 OF 3  
ANNEX – ENVIRONMENTAL INFORMATION:  
The environmental information disclosed in this annex including the EIP  
Pollution logo are in compliance with People’s Republic of China Electronic  
Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution  
Caused by Electronic Information Products.  
Part  
Toxic or hazardous Substance and Elements  
Name  
Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated  
(Pb) (Hg)  
(Cd)  
Chromium  
(Cr (VI))  
biphenyls  
(PBB)  
diphenyl ethers  
(PBDE)  
Semiconductor  
die  
X
X
O
O
O
O
O
O
O
Solder  
O
O
O
䰘ӊ - ⦃ֱֵᙃ:  
ℸ䰘ӊ᠔ᷛ⼎ⱘ
ᣀ⬉ᄤֵᙃѻક∵ᶧ೒ᷛⱘ⦃ֱֵᙃ  
ヺড়ЁढҎ⇥݅੠೑⬉ᄤ㸠Ϯᷛ
ޚ
 SJ/T11364 - 2006, ꢀ  
⬉ᄤֵᙃѻક∵ᶧ᥻
ᷛ䆚㽕∖ꢀ  
䚼ӊꢀ  
ৡ⿄ꢀ  
᳝↦᳝ᆇ⠽䋼៪
ܗ
㋴ꢀ  
䪙ꢀ  
∲ꢀ  
䬝ꢀ  
݁Ӌ䫀ꢀ  
໮⒈㘨㣃ꢀ  
໮⒈Ѡ㣃䝮ꢀ  
(PBDE)  
(Pb) (Hg) (Cd) (Cr (VI))  
(PBB)  
ञᇐԧ㢃⠛ꢀ  
⛞᥹⚍ꢀ  
X
X
O
O
O
O
O
O
O
O
O
O
© 2007 CRYDOM Inc., Specifications subject to change without notice.  

相关型号:

MS11-CMX100D6

3 -10 Amp 0-200 Vdc DC Output
CRYDOM

MS11-CMX200D3

3 -10 Amp 0-200 Vdc DC Output
CRYDOM

MS11-CMX60D10

3 -10 Amp 0-200 Vdc DC Output
CRYDOM

MS11-CMX60D5

3 -10 Amp 0-200 Vdc DC Output
CRYDOM

MS11-CX

3 -10 Amp 0-200 Vdc DC Output
CRYDOM

MS11-CX2405A

3 -10 Amp 0-200 Vdc DC Output
CRYDOM

MS11-CX240D5

3 -10 Amp 0-200 Vdc DC Output
CRYDOM

MS11-CXE240A5

3 -10 Amp 0-200 Vdc DC Output
CRYDOM

MS11-CXE240D5

3 -10 Amp 0-200 Vdc DC Output
CRYDOM

MS11-DMP6301A

Series MS11-CMX
CRYDOM

MS110

1 Amp Schottky Rectifier
MICROSEMI

MS110

SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
PANJIT