SSC800-25-14 [CRYDOM]
Transistor Output SSR, 1-Channel, 2500V Isolation, PLASTIC PACKAGE- 4;![SSC800-25-14](http://pdffile.icpdf.com/pdf2/p00242/img/icpdf/SSC1000-25-1_1468293_icpdf.jpg)
型号: | SSC800-25-14 |
厂家: | ![]() |
描述: | Transistor Output SSR, 1-Channel, 2500V Isolation, PLASTIC PACKAGE- 4 输出元件 光电 |
文件: | 总4页 (文件大小:536K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SSC Series
• IGBT based solid-state relay
• Ratings up to 25A @ 1,000 VDC
• DC control
PRODUCT SELECTION
25A
SSC800-25
25A
SSC1000-25
OUTPUT SPECIFICATIONS (1)
Description
800 VDC
0-800
900(4)
0.3
1000 VDC
Operating Voltage [VDC]
0-1000
1200(5)
0.3
MaxImumTransient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Maximum Load Current (3) [Adc]
25
25
Minimum Load Current [mA]
20
20
Maximum Surge Current [Adc] (10ms)
Maximum On-State Voltage Drop @ Rated Current [Vdc]
Thermal Resistance Junction to Case (Rjc) [°C/W]
75
1.6
0.8
75
1.6
0.8
INPUT SPECIFICATIONS (1)
Description
Suffix -12
12 VDC
8-16 VDC
8 VDC
1.0 VDC
15 mA
780 Ohm
1.5
1.5
Suffix -24
24 VDC
20-28 VDC
20 VDC
1.0 VDC
15 mA
Suffix -36
Nominal Control Voltage (6)
36 VDC
32-40 VDC
32 VDC
1.0 VDC
15 mA
Control Voltage Range
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Typical Input Current at Nominal Voltage
Nominal Input Impedance
Maximum Turn-On Time [msec] (4)
Maximum Turn-Off Time [msec]
1500 Ohm
1.5
2400 Ohm
1.5
1.5
1.5
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)(2)
Parameters
2500 VRMS
109 Ohm
Minimum Insulation Resistance (@ 500 V DC)(2)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
50 pF
-30 to 80°C
-40 to 125 °C
3.0 oz (86.5g)
Thermally conductive Epoxy
Encapsulation
Terminals
Screws and Saddle Clamps Furnished, Unmounted
6-32 Screws - 10 in lbs. 8-32 -20 in. lbs. (Screws dry without grase)
Recommended Terminal Screw Torque Range:
MECHANICAL SPECIFICATIONS
GENERAL NOTES
1
) All parameters at 25°C unless otherwise specified.
2) Dielectric strength and insulation resistance are measured between input and output
3) Heat sinking required, for derating curves see next page.
4) Internal overvoltage protection included.
5) Internal overvoltage protection not included.
6) Use suffix -12, -24 or -36 to specify control voltage. For other values call factory Sample: SSC800-25-24
THERMAL DERATE INFORMATION
WIRING DIAGRAM
Transient Protection
All loads are inductive, even ones that are not so labeled. An
inductive load will produce harmful transient voltages when it
is turned off. The more perfect the switch, the larger the
transient voltages; the MOSFET output is so nearly an ideal
switch that the transient voltages produced by seemingly
“non-inductive” loads can cause damage if not suppressed.
Diodes should be fast recovery type with PIV rated greater
than supply voltage.
Rev.031109
ANNEX - ENVIROMENTAL INFORMATION
©2020 ICPDF网 联系我们和版权申明