CP30H [CUI]
PELTIER MODULE;型号: | CP30H |
厂家: | CUI INC |
描述: | PELTIER MODULE |
文件: | 总6页 (文件大小:626K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
For more information, please visit the product page.
date 09/25/2017
page 1 of 6
SERIES: CP30H │ DESCRIPTION: PELTIER MODULE
FEATURES
• arcTEC™ structure on select models
• enhanced reliability for high thermal cycling
• superior thermal performance
• silicon sealed
• wide ΔT max
• low profile
• precise temperature control
• solid state construction
input
input
output
Qmax3
output
MODEL
voltage1
current2
∆Tmax4
max
max
Th=27°C
Th=50°C
Th=27°C
Th=50°C
(°C)
(Vdc)
(A)
(W)
(W)
(°C)
CP30138H
CP30238H
CP303385H5
3.8
8.8
3.0
3.0
3.0
7.3
8.0
70
70
70
77
77
77
16.6
29.8
18.0
32.5
15.7
Notes:
1. Maximum voltage at ΔT max and Th=27°C
2. Maximum current to achieve ΔT max
3. Maximum heat absorbed at cold side occurs at Imax, Vmax, and ∆T=0°C
4. Maximum temperature difference occurs at Imax, Vmax, and Q=0W (ΔT max measured in a vacuum at 1.3 Pa)
5. Designed with arcTEC™ structure.
PART NUMBER KEY
CP30 XXXX XXX H
Base Number
Length x Width:
1 = 15 x 15 mm
2 = 20 x 20 mm
3 = 30 x 30 mm
Thickness:
38 = 3.8 mm
3851 = 3.85 mm
Notes:
1. Only available in
30 x 30 mm size
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CP30H │ DESCRIPTION: PELTIER MODULE
date 09/25/2017 │ page 2 of 6
SPECIFICATIONS
parameter
conditions/description
min
typ
max
units
CP30138H
CP30238H
CP303385H
0.9
1.98
3.6
1.0
2.20
4.0
1.1
2.42
4.4
Ω
Ω
Ω
internal resistance1
solder melting temperature
assembly compression
hot side plate
connection between thermoelectric pairs
235
°C
MPa
°C
1
80
RoHS
2011/65/EU
Note:
1. Measured by AC 4-terminal method at 25°C
MECHANICAL DRAWING
units: mm
MATERIAL
96% AL2O3
22 AWG
PLATING
ceramic plate
wire leads
HOT SIDE
0.05
tin
silicon rubber 703 RTV (between cold
and hot side plates)
sealer
THICKNESS
joint cover
marking
silicon rubber 703 RTV
COLD SIDE
0.05
P/N & S/N printed on cold side
surface
10.0 3.0
Red (+)
WIDTH
COLD SIDE
Black (-)
LENGTH
100.0 5.0
LENGTH
WIDTH
THICKNESS
MODEL NO.
(mm)
15 ±0.3
20 ±0.3
30 ±0.3
(mm)
15 ±0.3
20 ±0.3
30 ±0.3
(mm)
CP30138H
CP30238H
CP303385H
3.8 ±0.025
3.8 ±0.025
3.85 ±0.02
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CP30H │ DESCRIPTION: PELTIER MODULE
date 09/25/2017 │ page 3 of 6
(
)
CP30138H PERFORMANCE Th=27°C
3 A
4.0
2.4 A
1.8 A
1.2 A
2.0
0.6 A
0
6.0
4.0
2.0
0
70
60
50
40
ΔT=Th-Tc (°C)
30
20
10
0
(
)
CP30138H PERFORMANCE Th=50°C
3 A
4.0
2.4 A
1.8 A
1.2 A
2.0
0
0.6 A
6.0
4.0
2.0
0
70
60
50
40
30
20
10
0
ΔT=Th-Tc (°C)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CP30H │ DESCRIPTION: PELTIER MODULE
date 09/25/2017 │ page 4 of 6
(
)
CP30238H PERFORMANCE Th=27°C
3 A
8.0
2.4 A
1.8 A
1.2 A
4.0
0
0.6 A
16
12
8.0
4.0
0
70
60
50
40
ΔT=Th-Tc (°C)
30
20
10
0
(
)
CP30238H PERFORMANCE Th=50°C
3 A
2.4 A
8.0
1.8 A
1.2 A
4.0
0
0.6 A
16
12
8.0
4.0
0
70
60
50
40
30
20
10
0
ΔT=Th-Tc (°C)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CP30H │ DESCRIPTION: PELTIER MODULE
date 09/25/2017 │ page 5 of 6
(
)
CP303385H PERFORMANCE Th=27°C
3 A
16
2.4 A
1.8 A
1.2 A
8.0
0
0.6 A
24
16
8.0
0
70
60
50
40
30
20
10
0
ΔT=Th-Tc (°C)
(
)
CP303385H PERFORMANCE Th=50°C
20
3 A
2.4 A
1.8 A
1.2 A
10
0.6 A
0
30
20
10
0
70
60
50
40
30
20
10
0
ΔT=Th-Tc (°C)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CP30H │ DESCRIPTION: PELTIER MODULE
date 09/25/2017 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
09/08/2016
09/25/2017
1.01
updated datasheet
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.